| number = ML20054J526
| issue date = 02/17/1982
| title = LER 82-003/03L-1:on 820201,containment Isolation Valve HCV-507A Failed to Close Upon Demand.Caused by Solenoid Valve Plunger Stuck in Energized Position.Plunger Freed & Valve Cycled.Emergency Procedure & Maint Order Issued
| author name = Mueller R
| author affiliation = OMAHA PUBLIC POWER DISTRICT
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
| docket = 05000285
| license number =
| contact person =
| document report number = LER-82-003-03L, LER-82-3-3L, NUDOCS 8206290176
| package number = ML20054J524
| document type = LICENSEE EVENT REPORT (SEE ALSO AO RO), TEXT-SAFETY REPORT
| page count = 4
}}
{{LER
| Title = 
| Plant =
| Reporting criterion =
| Power level =
| Mode =
| Docket = 05000285
| LER year = 2082
| LER number = 3
| LER revision =
| Event date =
| Report date =
| ENS =
| abstract =
}}
 
=text=
{{#Wiki_filter:. _        _ _ _            .            .              -                        - - _-                          .. -                      - - -
NRC FORM .V,6                                                                                                                                    U. S. NUCLE AR T.EGULATORY COMMISSION
  !                                                                                LICENSEE EVENT REPORT i'
CONTROL BLOCK: l 1
l    l    l    l    l lh 6
(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)
ITTil8 I. N l EuCE~SEE    l F lCOoE    C l S l 1 l@l 0 l0 l 0 l ace i4    i, 0 l0    l 0 l 0 l 0 l0 l0 2,l0 l@l4
                                                                                                    ~sE Nuv.ER                                    a            l1 l1 l1 l1 l@lu uil wl @
ucENSE 1,PE                    .,0 CON'T
  ;10111
    '7        8 3$"c 60lt]@l0'l5lol0lo12l815l@l012 bl              DOCK ET NUM8ER                        68    69 10EVENT 11 DATE    18 l2 l@l01211  74          75          REPORT DATE l 718 '180l@
EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h
[ O l 21 l During routine operations at approximately 992; cower, the containment isolaticn v11va i g jassociated with the " gas vent header", (HCV-507A), failed to close upon demand.                                                                                                                                  Emer-l
      ; o g 4,    lgency procedure, EP-25. " Loss of Containment integrity", was immediately issued and                                                                                                                        I
, g lfollowed. An emergency Maintenance Order (M.O.) was written to correct the problem                                                                                                                                        l l 0 l r, l land the valve was restored to an operable status within the 6 hour time constraint of I
!    l O 17 lT I echnical Specification 2.0.l(1).                                                  During the incident, the redundant isolation valve.I ioig, lHCV-507B,                      remained operable and closed upon demand.                                                                                                                                          I i7            8 9                                                                                                                                                                                                            50 DE              CODE        SU8C E                          COMPONENT CODE                            st.,9C DE                $                    E
[O[9]                            lS lD l@ l El@ W@ lV l A I L l V l 0 l P l@ y@ (Lj @                                                                                          20
; 3            8                        9            10          11              12                    13                                    is              19
                                    ,,.                                                SE QUENTI AL                              OCCUR R E NCE                REFORT                                          REVISION LER         EVENT YE AR                                    REPOR T NO.                                        CODE                    TYPE                                              NO.
                  @ yg'HOa
_ 21 1812I 22 l-l 23 1010131 24                    26 M
27 lo 13 I 28          23 l L,j Ju
(-]
31 ll_j 32
                      #EN A TC                    ON PL NT          M T O                            HOURS 22            SB IT D              FOR            8.      SUPPL E                                  MANUFACTURER lBlgl4Z lg lZ lg C3        J                    3b gg 30                    3 l0l0l0l0l 40 lY 48 l@          l4'iN l@                lX 43 l@                  l44A l4 l9 l947l@
CAUSE CESCmPTioN AND CORRECT!vE ACTIONS i l t j o l lEmergency M.0. #13830 was written to correct the valva orelm.                                                                                              It was discovered                                        1 y lthat the solenoid valve plunger had stuck in the "enernizad position"                                                                                                                      TFe scienoid                !
j        , ,      jplunger was freed and the valve was cycled several times to verify operability orlor                                                                                                                        I g lto returning                            to an operable status.                                                                                                                                                        l I
L' l_* ! I                                                                                                                                                                                                              80 7      8 9 STA S              % POWER                          OTHER ST ATUS                      Disc        FY                                DISCOVERY DESCRIPTION NA                                                              Operator Observation i s lE l@ l 019 l 9 "l@l" l    l" A l@l                                                                                                          l AEiviTY cOSTENT RELEASE                                      AMOUNT OF ACTIVITY                                                                        LOCATION OF RELEASE
' W U @D OF RELEASE [,2 jgl                                    NA                                      l            l          NA                                                                                            l 1
7      H 9                10_            19                                                  44              45                                                                                                      80
;                      PERSONNEL FXPOSUREE NUMBER y l0 l0 l0 l@lZTYPE                            l        @lDESCHtPTION N l
PE nSONNE L iNJu'n'iES N UMflE R              DESCRIPTION 7
i a 8 9 l0 l0 l0 l@l  11          12 NA 80 l
LOSS OF OR DAMACE TO FACILITY TYPE      DESCRIPTION y U@l                                  NA                                                                                                                                                                                l PUnu$ry iss 8206290176 820617                                                                                                                  NRC USE ONLY
* PDR S        ADOCK 05000285 Q {VEn@lDEScmrtiON                      NA                                                              PDR                                                          I          IIIIIIIIIIIIIE 7      8 9            to                                                                                                                                        6s 6e                                                80 2
                                                                                                                                                                                                ~
NAME oF PnEPARER                                                                                                        PHONE-
 
  ,A  ..
LER 82-003 Omaha Public Power District Fort Calhoun Station Unit No. 1 Docket NO. 05000285 ATTACHMENT NO. 1 Safety Analysis The Fort Calhoun Station is designed such that no single failure, by itself, can adversely affect the safe shutdown of the plant.
The function of HCV-507A (and its redundant valve HCV-507B) is to isolate the gas vent header at the containment boundary when activated by a Containment isolation Actuation Signal. Both HCV-507A and HCV-507B are energize-to-open/ fail closed valves. During the time HCV-507A was inoperable due to a stuck solenoid valve plunger, the redundant valve HCV-507B was operable and would have been capable of isolating the vent header at the containment pressure boundary had it been necessary.
During the time HCV-507A was being repaired, the operation of HCV-507B was verified by cycling the valve.
I 1
l l
1
 
t LER 82-003 Omaha Public Power District Fort Calhoun Station Unit No. 1 Docket No. 05000285 ATTACHMENT ;0. 2 Corrective Action M.0. #13830 was written to investigate the closure problem with HCV-507A.          Subsequently, it was determined that the solenoid plunger had stuck in the " energized" position, thereby not allowing air to vent from the operator and allow the valve to close.                                      The solenoid plunger was freed and the solenoid was satisfactorily tested and returned to oper-able status. Since the valve was returned to status in less than 6 hours (the time allowed for repair without having to attain hot shut-down), the plant remained at approximately 99% power. As a further precaution, the HCV-507A solenoid was changed out with a spare per M.O.
                #14010 (on 2/17/82). Upon solenoid replacement, the HCV-507A valve was satisfactorily tested for operability per applicable portions of sur-veillance test ST-ISI-WD-1, F.1.
 
LEP. 82-003 Omaha Public Power District Fort Calhoun Station Unit No. 1 Docket No. 05000285 ATTACIDIE:;T ;io. 3 Failure Data This is the first reportable failure of a containment isola tion valve due to a solenoid valve malfunction at the Fort Calhoun Station.
}}
 