ML17277A611: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) Created page by program invented by StriderTol |
StriderTol (talk | contribs) StriderTol Bot change |
||
| Line 6: | Line 6: | ||
| number = ML17277A612 | | number = ML17277A612 | ||
| issue date = 05/18/1983 | | issue date = 05/18/1983 | ||
| title = | | title = Interim Deficiency Rept 216 Re RHR Relief Valve Vents. Initially Reported on 821022.Relief Valves Will Be Removed, Containment Leakage Path Will Be Eliminated & Steam Condensing Mode Will Be Deactivated.Next Rept by 830817 | ||
| author name = Carlisle C | | author name = Carlisle C | ||
| author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM | | author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM | ||
Latest revision as of 22:13, 7 March 2020
| Date released: 06/27/2018 | Download: ML17277A611 |
|---|---|
| ML17277A612 | |
| Person / Time | |
|---|---|
| Site: | Columbia |
| Issue date: | 05/18/1983 |
| From: | Carlisle C WASHINGTON PUBLIC POWER SUPPLY SYSTEM |
| To: | MARTIN J B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| References | |
| Download: ML17277A612 (8) | |
| ML17277A610 | |
| Person / Time | |
|---|---|
| Site: | Columbia |
| Issue date: | 06/22/1983 |
| From: | Bouchey G WASHINGTON PUBLIC POWER SUPPLY SYSTEM |
| To: | SCHWENCER A Office of Nuclear Reactor Regulation |
| References | |
| Download: ML17277A610 (8) | |