ML17352B017: Difference between revisions

From kanterella
Jump to navigation Jump to search
Created page by program invented by StriderTol
StriderTol Bot change
 
Line 6: Line 6:
| number = ML17352B019
| number = ML17352B019
| issue date = 12/31/1994
| issue date = 12/31/1994
| title = Forwards Nonproprietary WCAP-14238 & Proprietary WCA-14237, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis..., Demonstrating Compliance W/Lbb Methodology.Proprietary Rept Withheld
| title = Nonproprietary Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Turkey Point Units 3 & 4 Nuclear Power Plants.
| author name = Bhowmick D, Petsche J, Prager D
| author name = Bhowmick D, Petsche J, Prager D
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Line 21: Line 21:
| number = ML17352B018
| number = ML17352B018
| issue date = 01/27/1995
| issue date = 01/27/1995
| title = Forwards Nonproprietary WCAP-14238 & Proprietary WCA-14237, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis..., Demonstrating Compliance W/Lbb Methodology.Proprietary Rept Withheld
| title = Requests That Proprietary Rept WCAP-14237, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Turkey Point Units 3 & 4 Nuclear Power Plants Be Withheld Per 10CFR2.790
| author name = Liparulo N
| author name = Liparulo N
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.

Latest revision as of 19:10, 6 March 2020

Forwards Nonproprietary WCAP-14238 & Proprietary WCA-14237, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis..., Demonstrating Compliance W/Lbb Methodology.Proprietary Rept Withheld
Date released: 07/31/2018 Download: ML17352B017


Nonproprietary Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Turkey Point Units 3 & 4 Nuclear Power Plants.
ML17352B019
Person / Time
Site: Turkey Point 
Issue date: 12/31/1994
From: Bhowmick D, Petsche J, Prager D
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17352B019 (82)
Requests That Proprietary Rept WCAP-14237, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis for Turkey Point Units 3 & 4 Nuclear Power Plants Be Withheld Per 10CFR2.790
ML17352B018
Person / Time
Site: Turkey Point 
Issue date: 01/27/1995
From: Liparulo N
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: RUSSELL W T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17352B018 (11)
Forwards Nonproprietary WCAP-14238 & Proprietary WCA-14237, Technical Justification for Eliminating Large Primary Loop Pipe Rupture as Structural Design Basis..., Demonstrating Compliance W/Lbb Methodology.Proprietary Rept Withheld
ML17352B016
Person / Time
Site: Turkey Point 
Issue date: 02/02/1995
From: Plunkett T
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17352B016 (9)