| title = | | title = LER 79-035/03L-0:on 791109,RHR Svc Water Line Supports Found W/Safety Factor Less than Two.Containment Cooling Loop Declared Inoperable.Caused by Design Deficiency.Supports Modified for Factor Above Four,Loop Returned to Svc | ||
| author name = Leech K | | author name = Leech K | ||
| author affiliation = COMMONWEALTH EDISON CO. | | author affiliation = COMMONWEALTH EDISON CO. |
Latest revision as of 17:28, 23 January 2020
Date released: 09/27/2019 | Download: ML19256F239 |
---|---|
ML19256F253 | |
Person / Time | |
---|---|
Site: | Quad Cities ![]() |
Issue date: | 11/30/1979 |
From: | Leech K COMMONWEALTH EDISON CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML19256F253 (1) | |
ML19256F238 | |
Person / Time | |
---|---|
Site: | Quad Cities ![]() |
Issue date: | 11/30/1979 |
From: | Kalivianakis N COMMONWEALTH EDISON CO. |
To: | KEPPLER J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |