ML19260C372: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 6: Line 6:
| number = ML19260C375
| number = ML19260C375
| issue date = 12/18/1979
| issue date = 12/18/1979
| title = Forwards LER 79-112/03L-0
| title = LER 79-112/03L-0:on 791119,valve MS106 Failed to Open During Surveillance Testing.Caused by Improper Installation of Worm Gear Spacer.Drive Sleeve Machined & Worm Gear Spacer Reinstalled
| author name = Oneill J
| author name = Oneill J
| author affiliation = TOLEDO EDISON CO.
| author affiliation = TOLEDO EDISON CO.

Latest revision as of 14:13, 23 January 2020

Forwards LER 79-112/03L-0
Date released: 10/01/2019 Download: ML19260C372


LER 79-112/03L-0:on 791119,valve MS106 Failed to Open During Surveillance Testing.Caused by Improper Installation of Worm Gear Spacer.Drive Sleeve Machined & Worm Gear Spacer Reinstalled
ML19260C375
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 12/18/1979
From: Oneill J
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19260C375 (2)
Forwards LER 79-112/03L-0
ML19260C371
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 12/18/1979
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19260C371 (1)