ML19294C032: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 6: | Line 6: | ||
| number = ML19294C036 | | number = ML19294C036 | ||
| issue date = 02/29/1980 | | issue date = 02/29/1980 | ||
| title = | | title = LER 80-005/03X-1:on 800131,during IE Bulletin 79-14 Insp, Discovered That Thermal Restraint Was Omitted from RHR Sys. Caused by Error in Transferring Piping Design to Const Drawings.Restraint Has Been Installed | ||
| author name = Sauer D | | author name = Sauer D | ||
| author affiliation = WISCONSIN PUBLIC SERVICE CORP. | | author affiliation = WISCONSIN PUBLIC SERVICE CORP. |
Latest revision as of 12:58, 20 January 2020
Date released: 11/04/2019 | Download: ML19294C032 |
---|---|
ML19294C036 | |
Person / Time | |
---|---|
Site: | Kewaunee ![]() |
Issue date: | 02/29/1980 |
From: | Sauer D WISCONSIN PUBLIC SERVICE CORP. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML19294C036 (1) | |
ML19294C031 | |
Person / Time | |
---|---|
Site: | Kewaunee ![]() |
Issue date: | 02/29/1980 |
From: | Mathews E WISCONSIN PUBLIC SERVICE CORP. |
To: | KEPPLER J G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML19294C031 (1) | |