* consumers Power company General Offices: 212 West Michigan Avenue, .Jackson, Michigan 49201
                                                                                        *
* Area Code 517 788-0550 May 10, 1979 Director, Nuclear Reactor Regulation Att Mr Dennis L Ziemann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 -LICENSE DPR-20 -PALISADES PLANT -ADDITIONAL INFORMATION PERTAINilJG TO NRC LIST DATED MAY 4, 1979 Attached is Consumers Power Company's response to your request for additional information telecopied to us on May 8, 1979. .. R B DeWitt Manager, Production-Nuclear David P Hofffman Assistant Nuclear Licensing Administrator CC JGKeppler, USNRC 790515 0 >67
    \j'
* ITEM 1 Provide following information for Pressurizer Code Safety Valves: l. Number -3 2. Capacity -230,000 lb/h Each 3. Set Points -2485, 2525 and 2565
*-*-
: 4. Manufacturer and Model -Dresser/Consolidated Valve Division -Model 31 739 A-1. 5. Indications of Position -Downstream Temperature Indication (Alarm in Control Room) 6. Challenger  
e consumers Power company General Offices: 212 West Michigan Avenue, .Jackson, Michigan 49201
-None 7. Experience of Two Phase or Subcooled Discharge  
* Area Code 517 788-0550 May 10, 1979 Director, Nuclear Reactor Regulation Att Mr Dennis L Ziemann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR         PALISADES PLANT - ADDITIONAL INFORMATION PERTAINilJG TO NRC LIST DATED MAY 4, 1979 Attached is Consumers Power Company's response to your request for additional information telecopied to us on May 8, 1979.
-None ITEM 2 Provide data for the table below:
                                                                                                        .
* MAIN FEED-WATER SYSTEM
R B DeWitt Manager, Production-Nuclear
* Pumps Drives Type Capacity Shut-off Head Type Supply Exhaust Trips Single Stage Centrifugal (2) 13,500 Gpm at 5000 r/min 2,640 Ft at 5000 r/min Steam Main Steam Line/HP Turbine Exhaust Main Condenser Low Suction Pressure Condenser Low Vacuum High Thrust Over speed Manual -Local and Remote Block Valve: (Mfg/Type/
        ~j~
Fail Position/Pas Indication)
David P Hofffman Assistant Nuclear Licensing Administrator CC JGKeppler, USNRC 790515 0 >67
Walworth Model 5232 P SB-WE/ Air Operated Gate/As Is/Yes Condensate Pumps: (No/Strainers)
 
Two Pumps/No Strainers 1 
1
* *
* ITEM 1 Provide following information for Pressurizer Code Safety Valves:
* Demineralizers (No/No for Full Power/Mfg) (Bypass/Operation/
: l. Number - 3
Fail Position)
: 2. Capacity - 230,000 lb/h Each
FW Heaters (Bypass/ Operation/Fail Position)
: 3. Set Points - 2485, 2525 and 2565 ~sig
Booster Pumps (No)
: 4. Manufacturer and Model - Dresser/Consolidated Valve Division -
* 2 4/3/DeLaval Yes/Air Operated Valve/As Is Yes/Manual/As Is None Control Valves (Feed-Water Reg Valves) Vertical Mounted -1 Per Feedwater Train/ (Arrangement/Operation)
Model 31 739 A-1.
Pressurizer PORV Fail Position/Tested/
: 5. Indications of Position - Downstream Temperature Indication (Alarm in Control Room)
Temp Ind/Alarm-Location)
: 6. Challenger - None
.. Closed/Yes/Yes-RTDs Installed Downstream of PORVs/Ind and Alarm in Control Room l}}
: 7. Experience of Two Phase or Subcooled Discharge - None ITEM 2 Provide data for the table below:
* MAIN FEED-WATER SYSTEM Pumps     Type         Single Stage Centrifugal (2)
Capacity    13,500 Gpm at 5000 r/min Shut-off Head        2,640 Ft at 5000 r/min Drives    Type        Steam Supply      Main Steam Line/HP Turbine Exhaust Exhaust      Main Condenser Trips        Low Suction Pressure Condenser Low Vacuum High Thrust Over speed Manual - Local and Remote Block Valve: (Mfg/Type/                 Walworth Model 5232 P SB-WE/
Fail Position/Pas Indication)          Air Operated Gate/As Is/Yes Condensate Pumps:                       Two Pumps/No Strainers
*
(No/Strainers)
 
l
* 2
* Demineralizers (No/No for Full Power/Mfg) 4/3/DeLaval (Bypass/Operation/                   Yes/Air Operated Valve/As Is Fail Position)
FW Heaters   (Bypass/               Yes/Manual/As Is Operation/Fail Position)
Booster Pumps (No)                                 None Control Valves (Feed-Water Reg Valves) Vertical Mounted - 1 Per Feedwater Train/
(Arrangement/Operation)               Electro-Pneum~tic Pressurizer PORV                     Closed/Yes/Yes-RTDs Installed Downstream Fail Position/Tested/                  of PORVs/Ind and Alarm in Control Room Temp Ind/Alarm-Location)
*                ..
*}}

Revision as of 23:01, 20 October 2019

Forwards Addl Info Requested on 790508 Re Pressurizer Code Safety Valves & Main Feedwater Sys
ML18155A247
Person / Time
Site: Palisades 
Issue date: 05/10/1979
From: Dewitt R, Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Ziemann D
Office of Nuclear Reactor Regulation
References
TASK-07-03, TASK-7-3, TASK-RR NUDOCS 7905150309
Download: ML18155A247 (3)


Text

I

\j'

  • -*-

e consumers Power company General Offices: 212 West Michigan Avenue, .Jackson, Michigan 49201

  • Area Code 517 788-0550 May 10, 1979 Director, Nuclear Reactor Regulation Att Mr Dennis L Ziemann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - ADDITIONAL INFORMATION PERTAINilJG TO NRC LIST DATED MAY 4, 1979 Attached is Consumers Power Company's response to your request for additional information telecopied to us on May 8, 1979.

.

R B DeWitt Manager, Production-Nuclear

~j~

David P Hofffman Assistant Nuclear Licensing Administrator CC JGKeppler, USNRC 790515 0 >67

1

  • ITEM 1 Provide following information for Pressurizer Code Safety Valves:
l. Number - 3
2. Capacity - 230,000 lb/h Each
3. Set Points - 2485, 2525 and 2565 ~sig
4. Manufacturer and Model - Dresser/Consolidated Valve Division -

Model 31 739 A-1.

5. Indications of Position - Downstream Temperature Indication (Alarm in Control Room)
6. Challenger - None
7. Experience of Two Phase or Subcooled Discharge - None ITEM 2 Provide data for the table below:
  • MAIN FEED-WATER SYSTEM Pumps Type Single Stage Centrifugal (2)

Capacity 13,500 Gpm at 5000 r/min Shut-off Head 2,640 Ft at 5000 r/min Drives Type Steam Supply Main Steam Line/HP Turbine Exhaust Exhaust Main Condenser Trips Low Suction Pressure Condenser Low Vacuum High Thrust Over speed Manual - Local and Remote Block Valve: (Mfg/Type/ Walworth Model 5232 P SB-WE/

Fail Position/Pas Indication) Air Operated Gate/As Is/Yes Condensate Pumps: Two Pumps/No Strainers

(No/Strainers)

l

  • 2
  • Demineralizers (No/No for Full Power/Mfg) 4/3/DeLaval (Bypass/Operation/ Yes/Air Operated Valve/As Is Fail Position)

FW Heaters (Bypass/ Yes/Manual/As Is Operation/Fail Position)

Booster Pumps (No) None Control Valves (Feed-Water Reg Valves) Vertical Mounted - 1 Per Feedwater Train/

(Arrangement/Operation) Electro-Pneum~tic Pressurizer PORV Closed/Yes/Yes-RTDs Installed Downstream Fail Position/Tested/ of PORVs/Ind and Alarm in Control Room Temp Ind/Alarm-Location)

  • ..