The broken shutter at the SVP salt cake density meter was addressed on 7/18/19.  Berthold came on site and replaced the shield with a new one, moving the source from the old gauge into the new.  The new shield is a model LB 7440-F-CR device, serial no. 37625-13606.
The broken shutter at the SVP salt cake density meter was addressed on 7/18/19.  Berthold came on site and replaced the shield with a new one, moving the source from the old gauge into the new.  The new shield is a model LB 7440-F-CR device, serial no. 37625-13606.
Notified R1DO (Gray) and NMSS Events Notification E-mail group.
Notified R1DO (Gray) and NMSS Events Notification E-mail group.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/20190729en.html#en54174
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/20190730en.html#en54174
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 07:30, 30 July 2019

ENS 54174 +/-
Where
Rayonier Advanced Materials, Llc
Collins, Georgia (NRC Region 1)
License number: 381-1
Organization: Georgia Radioactive Material Pgm
Reporting
Agreement State
Time - Person (Reporting Time:+150.52 h6.272 days <br />0.896 weeks <br />0.206 months <br />)
Opened: Roger Wilson
10:31 Jul 19, 2019
NRC Officer: Jeffrey Whited
Last Updated: Jul 22, 2019
54174 - NRC Website