{{Adams
#REDIRECT [[LR-N07-0113, Supplement to Request for License Amendment Extended Power Uprate Steam Dryer Limit Curves]]
| number = ML071720368
| issue date = 05/18/2007
| title = Hope Creek - Supplement to Request for License Amendment Extended Power Uprate Steam Dryer Limit Curves
| author name = Joyce T P
| author affiliation = PSEG Nuclear, LLC
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000354
| license number = NPF-057
| contact person =
| case reference number = LCR H05-01, Rev 1, LR-N07-0113
| document type = Letter
| page count = 2
| project =
| stage = Supplement
}}
 
=Text=
{{#Wiki_filter:PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 0 PSEG Nuclear LLC 10 CFR 50.90 LR-N07-0113 LCR H05-01, Rev. 1 May 18, 2007 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Hope Creek Generating Station Facility Operating License Nos. NPF-57 NRC Docket No. 50-354
 
==Subject:==
Supplement to Request for License Amendment Extended Power Uprate Steam Dryer Limit Curves  
 
==Reference:==
: 1) Letter from George P. Barnes (PSEG Nuclear LLC) to USNRC, September 18, 2006 2) Letter from USNRC to William Levis, PSEG Nuclear LLC, April 20, 2007 3) Letter from George P. Barnes (PSEG Nuclear LLC) to USNRC, April 30, 2007 In Reference 1, PSEG Nuclear LLC (PSEG) requested an amendment to Facility Operating License NPF-57 and the Technical Specifications (TS) for the Hope Creek Generating Station (HCGS) to increase the maximum authorized power level to 3840 megawatts thermal (MWt).In Reference 2, the NRC requested additional information concerning PSEG's request, including the steam dryer limit curves for power ascension.
In Reference 3, PSEG stated that the limit curves were being developed.
The document in Attachment 1 to this letter provides the steam dryer limit curves.There are no regulatory commitments contained within this letter.The Attachment 1 document contains information which Continuum Dynamics, Inc.(C.D.I.) considers to be proprietary.
C.D.I. requests that the proprietary information be withheld from public disclosure in accordance with 10 CFR 2.390(a)(4).
An affidavit 95-2168 REV. 7/99 LR-N07-0113 LCR H05-01, Rev. 1 May 18, 2007 Page 2 supporting this request is provided in Attachment
: 1. A non-proprietary version of the document in Attachment 1, suitable for public disclosure, is provided in Attachment 2.Should you have any questions regarding this submittal, please contact Mr. Paul Duke at 856-339-1466.
I declare under penalty of perjury that the foregoing is true and correct.Executed on ,//#e1 0 7 ate)Sincerely, Thomas P. Joyce Site Vice President Salem Generating Station Attachments (2)1. C.D.I. Technical Note No. 07-19P, Rev. 0 (proprietary)
: 2. C.D.I. Technical Note No. 07-19NP, Rev. 0 (non-proprietary) cc: S. Collins, Regional Administrator
-NRC Region I J. Shea, Project Manager -USNRC NRC Senior Resident Inspector
-Hope Creek K. Tosch, Manager IV, NJBNE}}