ML16127A024: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
| Line 3: | Line 3: | ||
| issue date = 05/05/2016 | | issue date = 05/05/2016 | ||
| title = NRC Comments on Appendix C, SFP HCLPF Calc | | title = NRC Comments on Appendix C, SFP HCLPF Calc | ||
| author name = Titus B | | author name = Titus B | ||
| author affiliation = NRC/NRR/JLD | | author affiliation = NRC/NRR/JLD | ||
| addressee name = Mauer A | | addressee name = Mauer A | ||
| addressee affiliation = Nuclear Energy Institute (NEI) | | addressee affiliation = Nuclear Energy Institute (NEI) | ||
| docket = | | docket = | ||
Revision as of 04:45, 20 June 2019
| ML16127A024 | |
| Person / Time | |
|---|---|
| Issue date: | 05/05/2016 |
| From: | Brett Titus Japan Lessons-Learned Division |
| To: | Mauer A Nuclear Energy Institute |
| References | |
| Download: ML16127A024 (2) | |
Text
1 NRR-PMDAPEm Resource From:Titus, Brett Sent: Thursday, May 05, 2016 3:59 PM To: MAUER, Andrew Cc: Shams, Mohamed; Vega, Frankie
Subject:
NRC Comments on Appendix C, SFP HCLPF Calc.Hello Andrew, Listed below are the NRC's comments associated with the Sample SFP HCLPF Calculation discussed during the public meeting on April 20 th. As you will see, they are primarily clarifications.
-6041 is developed with th e guideline that "the Seismic Margin Earthquake (SME) will be conservatively specified," such that "in the frequency range of interest, in each direction, there is no more than approximately 16% probabi lity that the response spectrum ordinate will be exceeded if the specified SME ground motion level occurs." Please clarify how using the CDFM approach with the GMRS results in a calculated HCLPF that has the same level of statistical significance as in NP-6041.
- 2) In section C4.0, please clarify if critical wall or floor spans will account for plant-specific design features, such as walls delimiting refueling channels, openings or gates.
- 3) The Appendix C calculations use a 7% damped in-s tructure response spectr um to account for the effects of concrete cracking fr om high seismic demands (i.e., page 18). However, the NRC SFP study (NUREG-2161) uses an ISRS associated with a 10% damped GMRS and a 5% ISRS for calculating seismic coefficients and hydrodynamic pressures (e.g., page 45-46). Please provide a rationale for
how these different parameterizations of damping between NUREG-2161 and Appendix C yield results that appear to "compare well" (e.g., Section C.6).
Please let me know if there are any questions.
Thank you, Brett Titus NRR/JLD/JHMB
Office O-13E20 Mail Stop O-13A01 301-415-3075
Hearing Identifier: NRR_PMDA Email Number: 2823 Mail Envelope Properties (Brett.Titus@nrc.gov20160505155800)
Subject:
NRC Comments on Appendix C, SFP HCLPF Calc. Sent Date: 5/5/2016 3:58:49 PM Received Date: 5/5/2016 3:58:00 PM From: Titus, Brett Created By: Brett.Titus@nrc.gov Recipients: "Shams, Mohamed" <Mohamed.Shams@nrc.gov>
Tracking Status: None "Vega, Frankie" <Frankie.Vega@nrc.gov>
Tracking Status: None "MAUER, Andrew" <anm@nei.org> Tracking Status: None
Post Office: Files Size Date & Time MESSAGE 1617 5/5/2016 3:58:00 PM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: Recipients Received: