ENS 53952: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 12: | Line 12: | ||
| emergency class = Non Emergency | | emergency class = Non Emergency | ||
| notification date = 03/22/2019 14:22 | | notification date = 03/22/2019 14:22 | ||
| retracted = Yes | |||
| notification by = John Chippo | | notification by = John Chippo | ||
| NRC officer = Jeffrey Whited | | NRC officer = Jeffrey Whited | ||
| event date = 03/21/2019 00:00 EDT | | event date = 03/21/2019 00:00 EDT | ||
| last update date = | | last update date = 04/24/2019 | ||
| title = | | title = En Revision Imported Date 4/25/2019 | ||
| event text = The following was received from the Commonwealth of Pennsylvania via e-mail: | | event text = EN Revision Text: AGREEMENT STATE REPORT - FAILED MOISTURE GAUGE SHUTTER | ||
The following was received from the Commonwealth of Pennsylvania via e-mail: | |||
The licensee reported that on March 21, 2019, the Berthold Technologies Model LB-7 410 moisture gauge containing 300 milliCuries of americium-241 was not able to operate as designed; the shutter locking mechanism cylinder was able to be pulled out of the gauge. The gauge was being removed from the east side of #3 Blast Furnace to the storage area at the Blast Furnace spares building. A service provider was already scheduled on site to observe removal and transport of the gauge. A contract employee working with the service provider stated that the cylinder was able to be pulled out of the gauge. The cylinder was never fully removed, but if it was, this would allow the shutter to be manually opened or closed. The cylinder locking device was depressed by the service provider employee and it is currently in that condition. The shutter can't be moved with the cylinder depressed. The gauge is currently locked in the storage area at the Blast Furnace spares building. | The licensee reported that on March 21, 2019, the Berthold Technologies Model LB-7 410 moisture gauge containing 300 milliCuries of americium-241 was not able to operate as designed; the shutter locking mechanism cylinder was able to be pulled out of the gauge. The gauge was being removed from the east side of #3 Blast Furnace to the storage area at the Blast Furnace spares building. A service provider was already scheduled on site to observe removal and transport of the gauge. A contract employee working with the service provider stated that the cylinder was able to be pulled out of the gauge. The cylinder was never fully removed, but if it was, this would allow the shutter to be manually opened or closed. The cylinder locking device was depressed by the service provider employee and it is currently in that condition. The shutter can't be moved with the cylinder depressed. The gauge is currently locked in the storage area at the Blast Furnace spares building. | ||
All work was performed using ALARA principles and at no point were employees exposed to excess levels of radiation. Survey results indicated no abnormal amounts of radiation in the area before, during, or after the removal of the device. Berthold has been contact for repair or replacement. | All work was performed using ALARA principles and at no point were employees exposed to excess levels of radiation. Survey results indicated no abnormal amounts of radiation in the area before, during, or after the removal of the device. Berthold has been contact for repair or replacement. | ||
PA Event Report ID No: PA19001 | PA Event Report ID No: PA19001 | ||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/ | * * * RETRACTION FROM THE JOHN CHIPPO TO CATY NOLAN ON 4/24/19 AT 1059 EDT * * * | ||
The following was received via fax: | |||
A follow-up interview and review of the operation of the locking mechanism was conducted with the contract employee. It was determined that the contract employee was unfamiliar with the operation of the locking mechanism at the time of the removal and that the cylinder never was able to be pulled out of the gauge. Based on this investigation, it has been determined that there was not a failure of the locking mechanism or shutter during the removal of the gauge on March 21, 2019. Therefore, this event should be retracted from NMED. | |||
Notified R1DO (Lilliendahl) and NMSS Events (via email). | |||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/20190425en.html#en53952 | |||
}} | }} | ||
{{ENS-Nav}} | {{ENS-Nav}} |
Latest revision as of 08:01, 25 April 2019
Where | |
---|---|
Us Steel Corporation Braddock, Pennsylvania (NRC Region 1) | |
License number: | PA-G0310 |
Organization: | Pa Bureau Of Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+34.37 h1.432 days <br />0.205 weeks <br />0.0471 months <br />) | |
Opened: | John Chippo 14:22 Mar 22, 2019 |
NRC Officer: | Jeffrey Whited |
Last Updated: | Apr 24, 2019 |
53952 - NRC Website | |