ML12208A129: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[SVP-12-062, Post Outage Inservice Inspection (ISI) Summary Report]]
| number = ML12208A129
| issue date = 07/13/2012
| title = Post Outage Inservice Inspection (ISI) Summary Report
| author name = Hanley T
| author affiliation = Exelon Nuclear, Exelon Generation Co, LLC
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000265
| license number = DPR-030
| contact person =
| case reference number = SVP-12-062
| document type = Letter, Report, Miscellaneous
| page count = 70
}}
 
=Text=
{{#Wiki_filter:ExelknExelon Generation Company, LLC www.exeloncorp.com Quad Cities Nuclear Power Station Nucear 22710 206th Avenue North Cordova, I L 61242-9740 10CFR50.55a SVP-12-062 July 13, 2012 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Quad Cities Nuclear Power Station Unit 2 Renewed Facility Operating License No. DPR-30 NRC Docket No. 50-265
 
==Subject:==
Unit 2 Post Outage Inservice Inspection (ISI) Summary Report Enclosed is the Quad Cities Nuclear Power Station Unit 2 Post-Outage Summary Report for Inservice Inspection examinations and Repair/Replacement activities conducted from the end of the March 2010 refueling outage through the March 2012 refueling outage. This report is due within 90 days after the end of the Unit 2 March 2012 refueling outage, which is July 17, 2012. This report documents examinations performed during the third period of the fourth inspection interval.This report is submitted in accordance with the requirements of ASME Section Xl, Article IWA-6200, "Requirements." If there are any questions or comments concerning this letter, please refer them to Mr. Wally Beck, Regulatory Assurance Manager, at (309) 227-2800.Sincerely, Tim Hanley Site Vice President Quad Cities Nuclear Power Station
 
==Attachment:==
 
Quad Cities Nuclear Power Station -Unit 2 Post Outage (90 Day) Summary Report cc: Regional Administrator
-NRC Region III NRC Senior Resident Inspector
-Quad Cities Nuclear Power Station Quad Cities Nuclear Power Station -Unit 2 Post Outage (90 Day) Summary Report Quad Cities Nuclear Power Station -Unit 2 Post Outage (90 Day) Summary Report Refueling Outage Q2R21 Outage Start Date: March 19, 2012 Outage End Date: April 18, 2012 Commercial Service Date: March 10, 1973 22710 2 0 6 th Avenue North Cordova, IL 61242 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Prepared by: ogeeY Reviewed by Reviewed by Reviewed by Reviewed by Approved by GarflKApp (ISI Engineer)
/ Nicfiohnson (IS[ Trainee Chris Hebel (Rea~or Internals Engineer)Gary KnKSnubber Engineer)Davhe z R n (Mraersrog rs Engineer)BrianjlUg (Repair/Replacement Engineer)Mathew Rice (Manager Program Engineering)
Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 Table of Contents
 
==1.0 INTRODUCTION==
 
..............................................................................................................................................
3 1. 1. OUTAGE, PERIOD AND INTERVAL START AND END DATES ...................................................................
3 1.2. EXAMINATION PROGRAM REQUIREMENTS
.........................................................................................
3 2.0 NIS-1 FORM .......................................................................................................................................................
4 3.0 ABSTRACT OF EXAMINATIONS, CONDITIONS NOTED AND CORRECTIVE MEASURES ..........
6 3.1. SECTION XI EXAMINATIONS
 
==SUMMARY==
...............................................................................................
6 3.2. BWRVIP-75-A/GENERIc LETTER 88-01 ..........................................................................................
7 3.3. INVESSEL INSPECTIO NS (IV I) ....................................................................................................................
7 Table 3.1-1 ASME Section XI Outage Summary ...............................................................................
8 Table 3. 1-IA Additional Exams in Accordance with IWF-2430(a)
....................................................
10 Table 3.1-IB Limited Coverage Summary ..........................................................................................
10 Table 3.1-2 Pressure Testing Summary Third Period .........................................................................
11 Table 3.1-3 Snubber Functional Tests ............................................................................................
12 Table 3.1-4 Conditions Noted on ASME Code Components and Corrective Actions ...............
13 Table 3.2-1 BWRVIP-75-A/GL 88-01 Outage Sunmtary .................................................................
14 Table 3.3 Number and Percentage of Examinations Completed
...........................................
15 4.0 REPAIR / REPLACEMENT
 
==SUMMARY==
................................................................................................
16 4 .1. N IS -2 IN D EX ...........................................................................................................................................
16 Table 4.1-1 Table 4.1-1 N IS-2 List ................................................................................................
16 4 .2 .N IS -2 F O R M S ..........................................................................................................................................
18 2 of 18 Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 1.0 Introduction 1.1. Outage, Period and Interval Start and End Dates This Inservice Inspection Summary Report encompasses examinations and repairs performed from April 14, 2010 through April 18, 2012 during the fourth ten-year interval third inspection period.This most recent refueling outage was the 2 1 st refueling outage for Quad Cities Nuclear Power Station Unit 2 and is the second outage for this unit during the third inspection period. The outage started March 19, 2012 and was completed April 18, 2012 when the unit returned to service.Tests, examinations, and repair/replacement activities associated with American Society of Mechanical Engineers (ASME) Code, Section XI were witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors.
Non-ASME Section XI or augmented examinations were not witnessed or otherwise verified by the Authorized Nuclear Inservice Inspectors and are marked "Not Required" or "N/A" on the applicable examination reports. The Authorized Nuclear Inservice Inspectors are inspectors of the Hartford Steam Boiler Inspection
& Insurance Company of Connecticut (HSB-CT).
The HSB-CT Regional Office is located at 2443 Warrenville Road Suite 500, Lisle, Illinois, 60532.1.2. Examination Program Requirements The examination requirements of ASME Boiler and Pressure Vessel Code, Section XI, Division 1,"Rules for Inservice Inspection of Nuclear Power Plant Components", 1995 Edition through 1996 Addenda were implemented for Class 1, 2 and 3 components except where written relief has been granted by the NRC. Written relief, in the form of Relief Request 14R-02 approving Risk Informed Inservice Inspection (RI-ISI) as an inspection program alternative for Code Categories B-F, B-J, C-F-i and C-F-2, was utilized during Q2R21. The ultrasonic examination volumes for RI-ISI components were increased from the Section XI requirements to meet the RI-ISI Program.The ultrasonic examination requirements of ASME Boiler and Pressure Vessel Code, Section XI, Appendix VIII, 1995 Edition with Addenda through 1996, as required by 10 CFR 50.55a, "Codes and Standards", and amended by the Federal Register Notice 64 FR 51370 dated September 22, 1999 is executed through the Performance Demonstration Initiative (PDI) Program according to the schedule defined in 10 CFR 50.55a(g)(6)(ii)(C), for wrought austenitic piping welds, ferritic piping welds, bolts/studs, reactor vessel welds, nozzle to vessel welds, nozzle inside radius sections and full structural overlaid wrought austenitic piping welds.3 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206th Avenue North, Cordova, IL 61242 2.0 NIS-1 Form FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules 1. Owner Exelon Generation Company, L.L.C., 300 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)2. Plant Quad Cities Nuclear Power Station, 22710 206"h Avenue North, Cordova, IL 61242 (Name and Address of Plant)3. Plant Unit Two 4. Owner Certificate of Authorization (if required)N/A 5. Commercial Service Date 3/10/73 6. National Board Number for Unit N/A 7. Components Inspected Component or Manufacturer Manufacturer State or National Appurtenance Or Installer or Installer Province No. Board No.Serial No.Reactor Pressure Chicago Bridge & Iron T-22 B0075000 N/A Vessel Reactor Recirculation Dravo Corp. N/A -See Table 3. 1-1 N/A N/A Core Spray Grinnell N/A -See Table 3. 1-1 N/A N/A Feedwater Grinnell N/A -See Table 3.1-1 N/A N/A Main Steam Grinnell N/A -See Table 3. 1-1 N/A N/A Residual Heat Grinnell N/A -See Table 3. 1-1 N/A N/A Removal Control Rod Drive Grinnell N/A -See Table 3. 1-1 N/A N/A High Pressure Coolant Grinnell N/A -See Table 3. 1-1 N/A N/A Injection Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8/2 in. x 111/2/2 in., (2) information in items I through 6 on this report is included on each sheet unless they are coded N/A, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.4 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206"h Avenue North, Cordova, IL 61242 FORM NIS-1 (Back)8. Examination Dates: 9. Inspection Period Identification:
4/14/10 to 4/18/12 3 rd Period -From 4/14/2010 to 4/18/2012 for the 4"h Interval 10. Inspection Interval Identification:
4th Interval -From 3/10/03 to 4/1/13 11. Applicable Edition of Section XI 1995 Addenda 1996 12. Date/Revision of Inspection Plan: 11/30/11 Revision 8 (4"h Interval)13. Abstract of Examination and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Section 3.0 and Tables 3.1-1, 3.1-1A, 3.1-1B, 3.1-2, 3.1-3, 3.1-4, 3.2-1, and 3.3.14. Abstract of Results of Examinations and Tests. See Section 3.0 and Tables 3.1-1 3.1-I A, 3.1- I B, 3.1-2, 3.1-3, 3.1-4, 3.2-1, and 3.3 15. Abstract of Corrective Measures.
See Section 3.0 and Table 3.1-4.We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the ASME Code, Section XI.Certificate of Authorization No. (if applicable)
N/A Expiration Date Date Z-., 20 / ~ Signed Exelon Corporation By Owner N/A CERTIFICATE OF INSER VICE INSPECTION I, the under signed, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois, and employed by Hartford Steam Boiler of Connecticut of Hartford, Connecticut have inspected the components described in the Owner's Report during the period 4/14/10 To 4/18/12 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions s,3 i A, ILLZZ,/ -Inspector's Signature National Board, State, Province, and Endorsements Date i ,j 20 1;, 5 of 18 Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 3.0 Abstract of Examinations, Conditions Noted and Corrective Measures 3.1. Section XI Examinations Summary A combination of ultrasonic (UT), liquid penetrant (PT), magnetic particle (MT) and visual (VT)testing were performed prior to and during the 2 1 st refueling outage on ISI Program components.
Volumetric and surface examinations were compared with the recorded results of previous examinations for applicable Class 1, 2 and RI-ISI components.
ISI inspections comprised of 33 volumetric (14 were RI-ISI, Category R-A welds), 9 surface examinations and 43 visual examinations were performed on Class 1, 2 and RI-ISI components.
Four follow-up visual exams were due to recordable indications in one IWF-2500-1 components.
One visual examination did not meet coverage requirements of ASME Section XI Code (i.e. greater than 90 percent of the specified examination volume) during Q2R21 and is listed in Table 3.1-1 B. Code cases used for ISI or Repair/Replacement activities are listed in the ISI Program Plan.Pressure testing VT-2 examinations not related to repair/replacement activities are documented in Table 3.1-2 for third period exams. The Class 1 Vessel System Leakage Test, the Reactor Vessel Head Flange Seal Leak Detection System Test, and Partial Class 2 system leakage tests were performed on outage test blocks with the balance of the systems to be tested by the end of the period. The tests were performed in accordance with the 1995 Edition 1996 Addenda of the ASME Section XI Code.Containment inspections were completed for Unit 2 for the second period of the 10-year interval in accordance with 2001 Edition through the 2003 Addenda of ASME Section XI Subsection IWE.All disassembled bolting surfaces were examined as required.Exelon personnel performed functional tests on a total of twenty-seven (27) snubbers for operability per the Service Life Monitoring/Failure Trending Sample and the 1995 edition through 1996 addenda of the ASME OM Code Subsection ISTD. Thirteen (13) snubbers were selected for the 10% sample group testing with the remaining fourteen (14) being tested for Service Life Monitoring.
Seventeen (17) of the twenty-seven (27) snubbers were ASME Section XI Code designated.
In addition, twenty-seven (27) replacement snubbers were tested and installed in accordance with a planned snubber replacement plan which is part of the Service Life Monitoring strategy.
Of the fifty-four (54) snubbers tested, all were found to be acceptable for continued operation.
Snubber testing activities are summarized in Table 3.1-3, "Quad Cities Unit 2 Snubber Functional Tests." Results are documented in WO 01333255.Table 3.1-4 "Quad Cities Unit 2 Conditions Noted on ASME Code Components and Corrective Actions" summarizes the conditions noted during the examinations and corrective measures taken prior to returning the unit to service.Table 3.3 identifies number and percentage of examinations completed in the fourth interval.6 of 18 Exelon Generation Company, L.L.C. Quad Cities Nuclear Power Station 300 Exelon Way Unit 2 Kennett Square, PA 19348 22710 206th Avenue North, Commercial Service Date March 10, 1973 Cordova, IL 61242 3.2. BWRVIP-75-A/Generic Letter 88-01 Augmented examinations required by Generic Letter 88-01, "NRC Position on Intergranular Stress Corrosion Cracking (IGSCC) in BWR Austenitic Stainless Steel Piping" and BWRVIP-75-A,"BWR Vessel and Internals Project, Technical Bases for Revisions to Generic Letter 88-01 Inspection Schedules", were implemented in the this outage (Table 3.2-1). Six (6) Category C Welds (susceptible to IGSCC but mitigated by stress improvement) were examined.
Four (4) of the Category C welds can be credited towards ASME Section XI examination percentages.
Four (4) Category E Welds (cracked weldments that have been mitigated by a weld overlay) were examined.
All welds were acceptable with no IGSCC indications.
This is consistent with previous examination results.3.3 In-Vessel Inspections (IVI)Relief Request 14R-15 is approved as an alternative to Category B-N- I and B-N-2 requirements.
No Category B-N-1 or B-N-2 exams were scheduled during Q2R21.Augmented examinations were preformed to implement additional BWRVIP requirements in accordance with the guidelines listed: " Visual inspections of two Jet Pump Assembly riser brace attachment welds in accordance with BWRVIP-41 Rev 3* Visual inspections Core Shroud Support Horizontal welds in accordance with BWRVIP-38" Visual inspections of the Steam Dryer Wall Support Lugs (WSL) and RPV attachment welds in accordance with BWRVIP-48-A Previous acceptable indications on the Steam Dryer Wall Support Lugs (WSL) were re-examined for signs of change. No significant changes were noted in these indications.
Quad Cities will continue to monitor this condition.
7 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206'h Avenue North, Cordova, IL 61242 Table 3.1-1 Quad Cities Unit 2 ASME Section XI Outage Summary (4 th Interval)Report Number Component Class Category Item Inspection Results Q2R21-071 RPV-THDW I B-A B 1.21 UT NRI Q2R21-072 RPV-THMS-0 I B-A B 1.22 UT NRI Q2R21-073 RPV-THMS-120 I B-A B 1.22 UT NRI Q2R21-074 RPV-THMS-180 I B-A B 1.22 UT NRI Q2R21-075 RPV-THMS-240 I B-A B 1.22 UT NRI Q2R21-076 RPV-THMS-300 I B-A B 1.22 UT NRI Q2R21-077 RPV-THMS-60 I B-A B 1.22 UT NRI 032-VT2 NI0 IRS I B-D B3.100 VT-2 NRI CLOSURE Q2R21-058 BUSHING I B-G- I B6.50 VT- I NRI Q2R21-059 CLOSURE NUTS I B-G-I B6.10 VT-I NRI Q2R21-060 CLOSURE STUDS I B-G- I B6.20 UT NRI CLOSURE Q2R21-061 WASHERS I B-G- I B6.50 VT- I NRI Q2R21-065 LIGAMENTS I B-G-l B6.40 UT NRI Recirc Pump 2B (2B-Q2R21-069 202) 1 B-G-I B6.180 UT NRI Recirc Pump 2B (2B-Q2R21-091 202) 1 B-G-I B6.190 VT- I NRI Q2R21-064 DECON FLANGE 3" I B-G-2 B7.50 VT- I NRI Q2R21-051 3204D-W-IOIA I B-K B10.20 SURF NRI Q2R21-070 RPV-SSLH I B-K B110.10 SURF NRI Recirc Pump 2B (2B-Q2R21-068 202) I B-L-2 B12.20 VT-3 NRI RT-001 2-203-3D-S I I B-M-1 B 12.40 RT Acceptable N/A RPV INTERIOR I B-N- I B13.10 VT-3 Acceptable
-Relief Request 14R- 15 N/A RPV INTERNALS I B-N-2 B13.20 VT-I/VT-3 Acceptable
-Relief Request 14R-15 CRD HOUSING Q2R21-062 (BOTTOM) I B-O B14.10 SURF NRI CRD HOUSING Q2R21-063 (TOP) I B-O B114.10 SURF NRI Q2R21-048 2A-1003A-3 2 C-A CIA. UT NRI Q2R21-049 2A- 1003A-4 2 C-A CI.20 UT NRI 019-VT2 N6A RHRHX NOZ 2 C-B C2.33 VT-2 NRI 019-VT2 N8A RHRHX NOZ 2 C-B C2.33 VT-2 NRI Q2R21-066 N8A-FI RHRHX 2 C-B C2.31 SURF NRI Q2R21-067 N8A-F2 RHRHX 2 C-B C2.31 SURF NRI Q2R21-023 1003A-W-201A 2 C-C C3.10 SURF NRI Q2R21-027 1009B-W-206A 2 C-C C3.20 SURF NRI Q2R21-029 1009B-W-210.6A 2 C-C C3.20 SURF NRI Q2R21-002 0200-M-130 I F-A FI.40 VT-3 NRI Q2R21-002 0200-M- 131 1 F-A FI.40 VT-3 NRI Q2R21-003 0200-M-132 I F-A FI.40 VT-3 NRI Q2R21-004 0200-M-138.1 I F-A FI.40 VT-3 NRI Q2R21-005 0200-M-155 I F-A FI.10 VT-3 NRI Q2R21-006 0200-W-105 A&B I F-A FI.10 VT-3 NRI 8 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206"h Avenue North, Cordova, IL 61242 Table 3.1-1 (continued)
Quad Cities Unit 2 ASME Section XI Outage p (4th Interval)Report Number Component Class Category Item Inspection Results...:. * ..., .. ... ,., .*.2: : * ......- i : ..:.Q2R21-007 0200-W-117 A&B I F-A FI. 10 VT-3 NRI Q2R21-008 0200-W-137 A&B I F-A FI.10 VT-3 NRI Q2R21-009 0200-W- 176 I F-A F1.40 VT-3 NRI Q2R21-010 0200-W- 178 1 F-A F1.40 VT-3 NRI Q2R21-018 0320-M-201 2 F-A FI.20 VT-3 NRI Q2R21-019 0320-M-202 2 F-A F1.20 VT-3 NRI Q2R21-020 03803-G-207 2 F-A F1.20 VT-3 NRI Q2R21-021 1003A-M-205 2 F-A F1.40 VT-3 NRI Q2R21-022 1003A-W-201 2 F-A F1.40 VT-3 NRI Q2R21-026 1009B-W-206 2 F-A FI.20 VT-3 NRI Q21121-028 100913-W-210.1 2 F-A FI.20 VT-3 NRI Q2R21-030 1012B-M-206 A&B 2 F-A F1.20 VT-3 NRI Q2R21-03l 1016B-M-204 2 F-A Fl.40 VT-3 Acceptable Q2R21-043 1202-M-106 I F-A FI. 10 VT-3 NRI RI -Setting found outside of allowable Q2R21-044 1265-M-101 I F-A F1.10 VT-3 (IR 1343011), Acceptable by repair Q2R21-050 3204D-W-101 A&B I F-A Fl. 10 VT-3 NRI Q2R21-052 3204F-W-103 I F-A FI.10 VT-3 NRI 032-VT2 0209A-FI0 I R-A R1.20 VT-2 NRI 032-VT2 0209A-FI6 I R-A R1.20 VT-2 NRI 032-VT2 0209A-F4 I R-A R1.20 VT-2 NRI 032-VT2 0209B-F2 I R-A R1.20 VT-2 NRI 032-VT2 0209B-F8 I R-A R 1.20 VT-2 NRI 032-VT2 1265-FI5R I R-A R1.20 VT-2 NRI 032-VT2 1265-F16R I R-A R 1.20 VT-2 NRI Q2R21-032 1016D-2 2 R-A R1.20 UT-E NRI Q2R21-033 1025-44 2 R-A R1.20 UT-E NRI Q2R21-034 1025-9 2 R-A R1.20 UT-E NRI Q2R21-035 1025-15 2 R-A RI.20 UT-E NRI Q2R21-036 1025-25 2 R-A R1.20 UT-E NRI Q2R21-037 1025-26 2 R-A R1.20 UT-E NRI Q2R21-038 1025-5 2 R-A R1.20 UT-E NRI Q2R21-039 10AD-S2 I R-A RI. I UT-E NRI Q2R21-040 lOBD-Sb1 I R-A RI.I I UT-E NRI Q2R21-041 10BD-S8 I R-A R1.1I UT-E NRI Q2R21-042 10BD-S9 I R-A RI.I UT-E NRI Q2R21-045 1401-7 2 R-A RI.20 UT-E NRI Q2R21-046 1402-5 2 R-A R1.20 UT-E NRI Q2R21-047 1402-7 2 R-A R 1.20 UT-E NRI 9 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206"h Avenue North, Cordova, IL 61242 Table 3.1-1A Additional Exams in Accordance with IWF-2430(a)
(4 th Interval)Report Number Component Class Category Item Inspection Results Q2R21-087 1202-M-102 I F-A Fl.10 VT-3 NRI Q2R21-088 1202-M- 110 I F-A FI.10 VT-3 NRI Q2R21-089 1265-G-101.3 I F-A Fl.10 VT-3 NRI Q2R21-090 1265-M-101.1 I F-A F1. I0 VT-3 NRI Table 3.1-1B Quad Cities Unit 2 ASME Section XI Limited Coverage Summary (4 th Interval)Report Number Component Class Category Item Inspection ASME % Coverage 02R21-010 0200-W-178 I F-A FI.40 VT-3 5.3 10 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6 th Avenue North, Cordova, IL 61242 Table 3.1-2 Quad Cities Unit 2 Pressure Testing Summary (4 th Interval)Third Period Item Work Relief Component Inspection Category Number Order Request Remarks B 15.10, All class I components RX. Class I Visual, VT-2 B-P 15.50, 15.60, 01359196 14R-07 Asl Lass I ent 15.70 System Leakage Test NI0 IRS Visual, VT-2 B-D B3.100 01359196 14R-01 Class I System leakage Test Line 2-0236-1" Visual, VT-2 C-H C7.30, C7.70 01333170 14R-05 Reactor Vessel Head Flange and 2-0234-l" Seal Leak Detection System 2A RHR Visual, VT-2 C-H C7.30, C7.70 01166131.
N/A MSIV Room piping, Balance C7.50 01379594 of System SBLC Visual, VT-2 C-H C7.30, C7.70 01166132 N/A Valves 1106A/B to 1101-1 CRD HCUs Visual, VT-2 C-H C7.10, 01379601 14R-06 CRD piping outside Drywell C7.30, C7.70 F C7.30.ECCS Suction Visual, VT-2 C-H C7.50, C7.70 01379592 N/A All ECCS Systems C750 C7.70.ECCS Fill Visual, VT-2 C-H C7.30, 01379570 N/A All ECCS Systems C7.50, C7.70 2B CS Visual, VT-2 C-H C7.30, 01379589 N/A Class 2 System leakage Test 2B CS VsaV-i- C7.50, C7 .70 11 General Note: Q2R21 is the second refuel outage of the third period for Unit 2. Some of the Class 2 boundary was examined during the first refuel outage (Q2R20) of the third period. The tests completed during the first refuel outage of the third period were included in the Q2R20 Post outage (90 Day) Summary Report. The third period is scheduled to end April 1,2013. Remaining portions examined online during the current period will be reported in the Q2R22 Post Outage (90 Day) Summary Report.11 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206"h Avenue North, Cordova, IL 61242 Table 3.1-3 Quad Cities Unit 2 Snubber Functional Tests (4 tb Interval)Subr EPN / ISI Number Class Category Item Reoe nbe/ Inspection Dae Results Number Installed Snubber Tested 10% Sample Group 2-1403-1/
Removed FT 03/20/12 Pass 1403-W-103A&B Installed FT 03/15/12 Pass 2-0202-B 19 / Removed FT 03/25/12 Pass 0200-M-130 Installed FT 03/13/12 Pass 2-0202-B25
/ Removed FT 03/24/12 Pass 0200-M-132 Installed FT 03/13/12 Pass 2-0203-28/
Removed FT 03/22/12 Pass 3001A-M-102.1 Installed FF 03/14/12 Pass 2-3001 -A56 / Removed FT 03/24/12 Pass 3001A-M-102.3 Installed FT 03/14/12 Pass 2-3019-A58
/ Removed FT 03/24/12 Pass N/A Installed FT 03/14/12 Pass 2-3001-B61
/ Removed FT 03/21/12 Pass 30011B-M-0101.1 Installed FT 03/14/12 Pass 2-1025-99
/ Removed FT 03/15/12 Pass 1025s-M-222 Installed FT 03/12/12 Pass 2-1025-101
/ Removed FT 03/15/12 Pass 1025-M-225 Installed FT 03/12/12 Pass 2-1424-A 109 / Removed FT 03/16/12 Pass N/A Installed FT 03/12/12 Pass 2-1313-116
/ Removed FT 03/13/12 Pass N/A Installed FT 03/12/12 Pass 2 -1016-A 123 / Removed FT 03/15/12 Pass 1016A-M-201.1 A&B Installed FT 03/13/12 Pass 2-1313-135
/ Removed FT 03/16/12 Pass N/A Installed FT 03/13/12 Pass Service Life Monitoring Group 2-1403-2 / Removed FT 03/20/12 Pass 1403-W-103 A&B Installed FT 03/15/12 Pass 2-1012-A6
/ Removed FT 03/21/12 Pass 21012A-W-102 Installed FT 03/16/12 Pass 2-1012-B7
/ Removed FT 03/23/12 Pass 210121B-W-102 Installed FT 03/19/12 Pass 2-0202-B24
/ Removed Fr 03/22/12 Pass 0200-M-131 Installed FT 03/13/12 Pass 2-0201 -A29 / Removed FT 03/24/12 Pass 0200-M- 117.2 Installed FT 03/13/12 Pass 2-1011-51
/ Removed FT 03/12/12 Pass 2-051 N/A N/A N/A Installed FT 03/12/12 Pass 2-057 2-3019-A57
/ N/A N/A N/A Removed FT 03/23/12 Pass N/A Installed FT 03/14/12 Pass 2-063 2-3019-E63
/ N/A N/A N/A Removed FT 03/22/12 Pass N/A Installed FTF 03/14/12 Pass 2-069 2-3019-C69
/ N/A N/A N/A Removed FT 03/22/12 Pass N/A Installed FT 03/14/12 Pass 2-3019-C70
/ Removed FT 03/20/12 Pass N/A Installed FT 03/14/12 Pass 2-3001-D72
/ Removed FT 03/20/12 Pass 2-72 300ID-M-101.2 I -A 1.0Installed FT 03/14/12 Pass 22-2306-I14/
Removed FT 03/15/12 Pass 2306-M-206.1 Installed FT 03/13/12 Pass 2-1016-A122
/ Removed FT 03/15/12 Pass 2 1016A-M-201.
A&B Installed FT 03/13/12 Pass 2-1079-136
/ Removed FT 03/12/12 Pass 26-36.N/A Installed FT 03/12/12 Pass 12 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6 th Avenue North, Cordova, IL 61242 Table 3.1-4 Quad Cities Unit 2 Conditions Noted on ASME Code Components and Corrective Actions (4 th Interval)Component ID Description
/ Resolution Pressure Test During the Unit 2 Class I Leakage Test the listed components were identified to be leaking. Reference VT report # VT2-032 dated 4/4/2012 in Work Order 1359196. Corrective actions were taken as follows: " IR's 1350193 identified a through wall leak (NI I B INSTR. NOZ) that was repaired and satisfactorily retested under WO 1529316" IR's 1350195, 1350196, 1350174, 1350172, 1350190, 1350176, 1350169, 1350178 identify mechanical connection and packing leakage.Mechanical Connections at CRD's Reference EC 389035 for evaluation of leakage through mechanical connections was acceptable.
CRD/HCUs -On Line bolted connection Reference EC 388738 for evaluation of leakage through mechanical connections was acceptable.
leakage for 3 Yd period Visual Inspections 1265-M- 101 IR 1343011 written due to spring can hanger found outside design range. This hanger did not meet the acceptance standard of ASME Section XI, IWF-3410(a)(4).
Corrective actions included re-setting of the spring can under WO 1524971 with satisfactory follow-up VT-3. In addition, scope expansion was performed to satisfy the requirements of ASME Section XI IWF-2430(a).
3953-M-343 (Class 3) IR 01340135 written due to rigid strut hanger found with a loose clamp. Although this appeared to be historic in nature as there was no evidence of thermal movement, this hanger did not meet the acceptance standard of ASME Section XI, IWF-3410(a)(2).
Corrective actions included repair of hanger under WO 01523193 with satisfactory follow-up VT-3. In addition, scope expansion was performed to satisfy the requirements of ASME Section XI IWF-2430(a).
As this is class 3, the follow-up exams would not be listed in table 3.1-IA.13 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206"h Avenue North, Cordova, IL 61242 Table 3.2-1 Quad Cities Unit 2 BWRVIP-75-A/GL 88-01 Outage Summary Pre/Post Report Component Class Outage Inspection Results Number Category Q2R21-012 02AS-S12 I E UT NRI Q2R21-013 02AS-S3 I C UT NRI Q2R21-014 02B-FI I C UT NRI Q2R21-015 02C-F7 I E UT NRI Q2R21-016 02H-$3 I E UT NRI Q2R21-017 02H-S4 I E UT NRI Q2R21-039 I OAD-S2' I C UT-E NRI Q2R21-040 IOBD-SIO' I C UT-E NRI Q2R21-041 10BD-S8' I C UT-E NRI Q2R21-042 I0BD-S9' I C UT-E NRI'Note: Weld is credited towards ASME Section X1 Risk Informed ISI Program population.
14 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 206"h Avenue North, Cordova, IL 61242 Table 3.3 Quad Cities Unit 2 Number and Percentae of Examinations Comtleted (4th Interval)Category Exams Completed in Q2R21 Exams Completed to Date Total Exams in the Interval Percentage Complete for Interval B-A 4  7 23 23 100%B-D 9  0 42 58 72%B-G-l' 7 17 5 340%B-G-2 2  I 31 31 100%B-K 2 8 8 100%B-L-2 5  I I I 100%B-M-I I I I 100%B-M-2 5  0 7 7 100%B-N-I 8  N/A N/A N/A N/A B-N-2 8  N/A N/A N/A N/A B-0 4  2 2 2 100%B-P 3  N/A N/A N/A N/A C-A 2 4 4 100%C-B 7  2 8 8 100%C-C 3 10 10 100%C-H 3  N/A N/A N/A N/A F-A 6  42 125 116 108%R-A 21 115 110 105%'Note: Category B-G- I contains reactor vessel studs and nuts. 1/3 of the reactor vessel studs, nuts, bushings, washers, and ligaments are examined each period. Since the component number is repeated in this category, each period may result in greater than the limiting percentage of exams.2 Note: B-G-2 category includes bolted connections when components are opened as well as in place under tension.3 Note: Category B-P and C-H exams are pressure tests tracked under Table 3.1-2.4 Note: Exam Category B-A and B-O are scheduled to coincide with previous interval to maintain ten year interval between exams and are performed in accordance with IOCFR50.55a.
Period completion percentage does not apply.-Note: Categories B-L-2, and B-M-2 are inspected and credited under the Repair/Replacement Program only when the component is disassembled.
Only one of each type of valve and pump are required to be examined.6 Note: Category F-A includes Class 1.2 and 3. There are 15 Class 3 hangers examined during Q2R21 that would not be listed in Table 3.1-1.7 Note: Only 12 components are required to be examined in Category C-B, however several are 100% obstructed and are required to be examined every period by VT-2 in accordance with Item Number C2.33. Therefore, percentage completion for the interval by item number does not apply.8 Note: B-N-I and B-N-2 Category Exams are credited by the performance of the BWRVIP program in accordance with Relief Request 14R-15.9 Note: Category B-D is subject to Relief Request 14R- 17 which reduces the total number of examinations during the 10 year interval for the third period. Subsequently, the alternative to ASME Code provides an altemative completion percentage than originally scheduled.
15 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 4.0 Repair / Replacement Summary Quad Cities Nuclear Power Station Unit 2 22710 206th Avenue North, Cordova, IL 61242 4.1 NIS-2 Index Table 4.1-1 Quad Cities Unit 2 NIS-2 List Program Number Work Request Number Component EPN ASME XI or Class Purchase Order 05-065 00687492-02 2-0201-1 1 11-028 PO# 432829 0-Spare (S/N BK6266) 1 11-042 & 11-043 1126985-02, 03 2-1106B 2 11-047 1451457-01 Spare 1 2-0202-B &11-048, -050, -051, -083, -112 1307798-22, 53, 54, 57, 01 M-1022D-272A 1 11-054 thru 11-073 1357003 Various Control Rod Drives 1 11-076 1334350-01 2-0203-4D 1 11-084 1361872-01 2-3001 -A56 1 11-085 1361877-01 2-3001 -B61 1 11-086 1361860-01 2-1025-101 2 11-087 1361863-01 2-2306-114 2 11-088 1361865-01 2-1016-A122 2 11-089 1361867-01 2-1016-A123 2 11-090 1361871-01 2-0203-28 1 11-091 1361881-01 2-3001-D72 1 11-092 1361846-01 2-0202-B19 1 11-093 1361847-01 2-0202-B25 1 11-094 1361848-01 2-0202-B24 1 11-095 1361853-01 2-1403-1 1 11-096 1361854-01 2-1403-2 1 11-097 1361855-01 2-1012-A6 1 11-098 1361856-01 2-1012-B7 1 11-099 1361849-01 2-0201 -A29 1 11-100 1361859-01 2-1025-99 2 2-2363-2" &11-101 & 12-018 880895-07, 01 2-2306-24" 2 11-102 1334358-01 2-0203-3D 1 11-104 1333556-01 2-0203-3C 1 11-105 1351615-01 2-0203-3A 1 11-106 1334352-01 2-0203-4H 1 11-107 1334353-01 2-0203-4G 1 11-108 1334351-01 2-0203-4C 1 11-117 1359120-01 2-0203-2B 1 11-118 1115612-01 2-0203-1B 1 11-122 PO 475200 0-Spare (Target Rock 225) 1 11-124 PO 478898 0-Spare (S/N BK07072) 1 11-125 PO 478898 0-Spare (BY94632) 1 11-128 PO# 475203 0-Spare (S/N BK6264) 1 12-003 PO 482065 0-Spare (S/N 61293/98) 1 12-004 PO 482065 0-Spare (S/N 61293/101) 1 12-005 PO 482065 0-Spare (S/N 61300/61) 1 12-006 PO 482065 0-Spare (S/N 61300/66) 1 12-007 PO 482065 0-Spare (S/N 61300/67) 1 16 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 Quad Cities Nuclear Power Station Unit 2 22710 2 0 6 th Avenue North, Cordova, IL 61242 Table 4.1-1 Quad Cities Unit 2 NIS-2 List Program Number Work Request Number Component EPN ASME XI or Class Purchase Order 12-008 PO 482065 0-Spare (S/N 61300/68) 1 0-Spare (S/N 12-009 PO 476651 01615123/078) 1 12-011 776083-01 2-0203-2D 1 12-012 1524727-01 2-0203-1A 1_ 1 12-013 1319135-01 2-0220-58B 1 12-021 1529316-01 2-N11B 1 17 of 18 Exelon Generation Company, L.L.C.300 Exelon Way Kennett Square, PA 19348 Commercial Service Date March 10, 1973 4.2 NIS-2 Forms (Attached)
Quad Cities Nuclear Power Station Unit 2 22710 206'h Avenue North, Cordova, IL 61242 18 of 18 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242/Date: 3/2/2006 Sheet: I of I Unit: 2 Program No. 05-065 WO 00687492-02 Repair Organizalion P.O. No.. Job No.. etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identificatioln of System: Reactor Vessel, Class I 5. (a) Applicable Construction Code: ASME Sect. III Class A 1965 Edition, Summer 1965 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
1995 Edition, 1996 Addenda, N/A Code Case 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Natl Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Reactor Vessel Chicago Bridge & Iron T22 N/A 2-0201-I 1970 Replacement Yes 7. Description of Work: Replaced reactor vessel flange bolting in accordance with the WO. q [ ..45'..8. Tests Conducted:
Hydrostatic
[] Pneumatic
' Nominal Operating Pressure X 7) 'is Other 0l Pressure -psi Test Temp. *F 9. Remarks: None.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this replacement conforms to the rules of ASME Code, Section XI repair or replacemeni Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 Apo B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -CJAA , A u !% -Date ftg ' 20060 V Owfier's Desiggfee.
Tilre CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Connecticut have inspected the components described in this Owner's Report during the period /.¥/L2IL.....--
to M W0/.6...
and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any k[und arising from or connected with this inspection.
c, (" A Commissions
/1 /o ps 20oo Nuflinal fkinn Stute. Pwrwlv~e.
und Enlniwwmn1*a 20 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I!. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: NWS Technologies 131 Venture Blvd., Spartanburg, SC, 29306 4. Identification of System: Main Steam. Class I Date: 3/1/2012 Sheet: I of I1 Unit: 0 Program No.: 11-028 WO: P.O. 432829 RIN 206593 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: ASME B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Main Steam Safety Consolidated BK6266 N/A UTC 2070094 N/A Repair / No Valve Safety Valve Div. Replacement
: 7. Description of Work: Replaced guide.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure E] Exempt E]Other [I Pressure __- psi Test Temp. -'F 9. Remarks: An internal VT-3 examination performed.
Pressure test to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report arecorrect and this Repair/ Replacement conforms to the rules of ASME Code, Section Xl Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Zf^ £ 4' Date z4-5 20 /1 Z Owner or Owner'9 Designe, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 6 1 to Q- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.n7 Commissions ,c ,svi- Aw4 ILZZit I Inspectors Signature National Board, State, Prtvince, and Endorsements Date Y 20 IZ-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: Standby Liquid Control, Class 2 Date: 5/18/2012 Sheet: I of I Unit: 2 Program No.: 11 -042 & 11-043 WO: 1126985-02
& -03 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Trigger Assembly Conax Buffalo UTC 2903191 N/A 2-1106B N/A Replacement No Valve Pug Conax Buffalo UTC 2888687 N/A 2-1106B N./A Replacement No 7. Description of Work: Replaced trigger assembly and valve plug.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure E] Exempt 0 Other Fl Pressure _ psi Test Temp._ 'F 9. Remarks: None.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed I les0t/Date
/20 J-Owner of'Ownfer' sDesigneeli tie V ,13 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period r I? .to 7- ,? , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or alo.f any kind arising from or connected with this inspection.
___Commissions
,-R im-ri, A N I tI'Lt tela.(tors Signature National Board. State, Province.
and Endorsements Date -" z2 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 2/29/2012 Sheet: I of _1 Unit: 0 Program No.: 11-047 WO: 1451457-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Residual Heat Removal, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 7. Description of Work: Replaced end cap.8. Tests Conducted:
Hydrostatic El Pneumatic
[]Other rl Pressure __ psi Nominal Operating Pressure El Exempt El Test Temp. __ 'F 9. Remarks: None.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A- Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Date 20 Owner or Owner'sý Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period T Ftn o. to B4 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage oA" oss of any kind arising from or connected with this inspection.
'- Commissions tatioial Bar itatPoi n Inspectors Signature National Board. State, Province, and Endorsem~ents Date I V'441-20 iz Date 20 '~-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 6/11/2012 Sheet: I of I Unit: 2 Program No.: I 1-112,048,050, 051,083 WO: 1307798-01, 22,53,54,57 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Reactor Recirculation, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N-652-1 6. Identification of Components Repaired or Replaced, and Re lacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Code Component Mfr. No. Bd. Identification Built Replaced, or Stamped No. Replacement (Yes or No)Rotating Elememt GE-Hitachi UTC 2903141 N/A 2-0202-B N/A Replacement No Stud Flowserve UTC 288495 1, N/A 2-0202-B N/A Replacement No 2886071 Hanger Rod Ber2en-Power UTC 2893911 N/A M- 1022D-272A N/A Replacement No Thread Rod Accutech UTC 2718244 N/A 2-0202-B N/A Replacement No Nut Nova UTC 2869861 N/A 2-0202-B N/A Replacement No iT Description of Work: Replaced rotating element and bolting. Overbored damaged casing thread hole #6. Machined Pump flange face.8. Tests Conducted:
Hydrostatic El Pneumatic El Other F] Pressure __ psi Nominal Operating Pressure 0 Exempt CE Test Temp. __ 'F 9. Remarks: None.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Z I -r Date 20 I, Owner or Owner't'Designee, Tigle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z' r-'h_ 1Z to z- AM_ IZ , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective mlsures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or (*9erty damage or a loss of any kind arising from or connected with this inspection.
________________________________________ommissions 1-ftt3ris ANIi Itzzi, ins.P tro4* nature Nastional Board. Stne, Prvi.nce.
md Endo.rsements Date 1ý .,, 20 ,-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road)Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242, 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 6/1/2012 Sheet: I of 3 Unit: 2 Program No.: 11-054 thru 11 -073 WO: 1357003 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Control Rod Drive, Class 1 5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or S _No)See Attachment A 7. Description of Work: Replaced Control Rod Drives and bolting in accordance with the W.O.8. Tests Conducted:
Hydrostatic 0J Pneumatic El (0 Other E] Pressure __ psi 9. Remarks: None.Nominal Operating Pressure [ Exempt U Test Temp. OF CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -'f ', Pfwq,, , -Date 7 20/Z Owner or Ofvner's Dsignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period .14 '.'r,., to 11 r-, , , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___Commissionsi-,0s IL, ' t. I uspectrs Signature Natk~nal Board, Slate, Province, and Endorsements Date 11 .-1-20 1 z Date 20 ~.
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)
As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 6/1/2012 Sheet: 2 of 3 Unit: 2 Program No.: 11-054 thru 11-073 WO: 1357003 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Control Rod Drive, Class 1 5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A Attachment A Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Control Rod Drive GE Nuclear S/N: 9561 N/A 2-0300-54-47 N/A Replacement No Enerv Control Rod Drive GE Nuclear S/N: 9244 N/A 2-0300-06-35 N/A Replacement No Ener_Control Rod Drive GE Nuclear S/N: 299 N/A 2-0300-06-43 N/A Replacement No Energ._Control Rod Drive GE Nuclear S/N: 486 N/A 2-0300-10-35 N/A Replacement No Ener_Control Rod Drive GE Nuclear S/N: A2109 N/A 2-0300-14-15 N/A Replacement No Ener_Control Rod Drive GE Nuclear S/N: 180 N/A 2-0300-18-19 N/A Replacement No Enerv,_Control Rod Drive GE Nuclear S/N: 382 N/A 2-0300-22-35 N/A Replacement No Control Rod Drive GE Nuclear S/N: 9249 N/A 2-0300-22-43 N/A Replacement No EnerU Control Rod Drive GE Nuclear S/N: 2063 N/A 2-0300-26-15 N/A Replacement No EnerU Control Rod Drive GE Nuclear S/N: A9705 N/A 2-0300-34-39 N/A Replacement No Ene-rU'Control Rod Drive GE Nuclear S/N: A3817 N/A 2-0300-38-27 N/A Replacement No Ene-ru Control Rod Drive GE Nuclear S/N: 552 N/A 2-0300-38-55 N/A Replacement No Eneýru Control Rod Drive GE Nuclear S/N: A8867 N/A 2-0300-42-47 N/A Replacement No EnerU, Control Rod Drive GE Nuclear S/N: A3619 N/A 2-0300-46-07 N/A Replacement No En-erU Control Rod Drive GE Nuclear S/N: 2065 N/A 2-0300-46-15 N/A Replacement N0o________________
Energv_______
____ _________
______ _________
____
FORM NIS-.2 OWNERS REPORT OF REPAIR OR REPLACEMENT (Supplement)
As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 6/1/2012 Sheet: 3 of 3 Unit: 2 Program No.: 11-054 thru 11-073 WO: 1357003 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Control Rod Drive, Class 1 5. (a) Applicable Construction Code: ASME Section III Edition: 1965 Addenda: Winter 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A Attachment A Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Control Rod Drive GE Nuclear S/N: 1803 N/A 2-0300-46-19 N/A Replacement No Ener_ _Control Rod Drive GE Nuclear S/N: 1289 N/A 2-0300-50-15 N/A Replacement No Ener_Control Rod Drive GE Nuclear S/N: 362 N/A 2-0300-50-19 N/A Replacement No Ener___Control Rod Drive GE Nuclear S/N: 533 N/A 2-0300-50-39 N/A Replacement No Ener_Control Rod Drive GE Nuclear S/N: 1855 N/A 2-0300-54-15 N/A Replacement No Energ_Cap Screws Nova UTC 2901405, N/A Cat ID 42416-1 N/A Replacement No 2877780, 1 _ _ _ _ 1 2822995 1 1 1 1 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 5/31/2012 Sheet: I of I Unit: 2 Program No.: I 1-076 WO: 1334350-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B3 I. I / ASME Section III Edition: 1967 / 1965 Addenda: N/A / 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Valve Cons Safety S/N BK6318 N/A 2-0203-4D N/A Replacement No Valve Stud Nova UTC 2900361 N/A 2-0203-4D N/A Replacement No Hydranut Nova UTC 2908999, N/A 2-0203-4D N/A Replacement No 2885680 1 1 1 Hex Nuts Accutech UTC 2900506 N/A 2-0203-4D N/A Replacement N.o 7. Description of Work: Replaced valve and bolting.8. Tests Conducted:
Hydrostatic 0 Pneumatic El Nominal Operating Pressure [ Exempt LI Other nI Pressure _ psi Test Temp._ OF 9. Remarks: Performed VT-I on bolting.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section X1 Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed "Vf 6.1 -,, , Date t/g 20 le.Owner or Owfier's Destgnee, Title -- Y9 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT.'of Hartford, Connecticut have inspected the components described in this Owner's Report during the period '0i f-W Q to 31 M"s-% , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ Commissions Na,-A N t L Z -7 y [ln. " .' Sig'natture' National Board, State, Province.
and Endorements Date I -IJýj 20 le.L fl~n~ 120 1?-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI A I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, It. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 4/1/2012 Sheet: I of I Unit: 2 Program No.: f1 -084 WO: 1361872-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re lacement Components:
Name of Name of Mfrs. Ser. Nat'i Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega UTC 2900189 N/A 2-3001 -A56 N/A Replacement No 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic El Pneumatic 0l Nominal Operating Pressure El Exempt Z Other E] Pressure _ psi Test Temp. -'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Z ,' I ,/D,, /'/, ate i642 20 12 Owner or'Owner's Designee,"rlitle
%J- f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 01 RP 4- to 731 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ _ _ _ Commissions
,- , tu  Inspectors Signature National Board, State, Province, and Endorsements
[Date I 11,4 20 1Z Date 20 IZ FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 3/28/2012 Sheet: I of .1 Unit: 2 Program No.: 11-085 WO: 1361877-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega UTC 2900192 N/A 2-3001 -B61 N/A Replacement No 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic E- Pneumatic El Nominal Operating Pressure El Exempt 0 Other El Pressure -psi Test Temp._ 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed g 5', Ai t ,,v .1  ,//, Date 20 le-Owner-or Owher's Des litee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i-7r Z 11. to Z3 r-Ot.[- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a oss. y kind arising from or connected with this inspection.
Commissions JCr. ) IL It-t Inspectors Signature National Board. State, Pntvince, and Endorsements 20 \2.L Date 30 P-m 20 \-Z-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 3/29/2012 Sheet: I of 1 Unit: 2 ProgramNo.:
11-086 WO: 1361860-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Residual Heat Removal, Class 2 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Cop ,onents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Pacific Scientific UTC 2900212 N/A 2-1025-101 N/A Replacement No Co.Taper Pin Anvil UTC 2884833 N/A 2-1025-101 N/A Replacement No International, Inc 7. Description of Work: Replaced snubber and taper pin.8. Tests Conducted:
Hydrostatic E5 Pneumatic E5 Nominal Operating Pressure 5 Exempt Z Other [] Pressure _ psi Test Temp._ OF 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -?14A , ';)Z:,J e 4W- , Date 1&20 q Owner or Owner's [esignee, , -CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois., and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period N to1r1- to I,'re n , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _-__ Commissions A t N Lt I 5'--nspectors Signature National Board, Stale. Province.
and Endorsements Date 20 ), Date 20 20 )t FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 4/8/2012 Sheet: I of I Unit: 2 Program No.: 11-087 WO: 1361863-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: High Pressure Coolant Iniection, Class 2 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and R placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Pacific Scientific UTC 2900210 N/A 2-2306-114 N/A Replacement No I Co._._._.7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 0 Other E] Pressure __ psi Test Temp. -F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 1 5 -R412 4"1 45;WI, z"-0I,,.DateI-.-e 20 /7 .Owner or Okne's Dw~gnee, Title ---0 ,r CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i4 ft,7,. to I1 Mh%,--vL , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ _ _ Commissions v 'ý AN II National Board. State. Prnvince.
and Endorsements Date ?- 20 1Z_Date ?- 20 I?
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova- IL 61242 Date: 3/29/2012 Sheet: I of I Unit: 2 Program No.: 11-088 WO: 1361865-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Residual Heat Removal, Class 2 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Pacific Scientific UTC 2900204 N/A 2-1016-A 122 N/A Replacement No I C o......__.
: 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic El Pneumatic FI Nominal Operating Pressure E] Exempt 0 Other El Pressure _ psi Test Temp. 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. Q A Program Certificate of Authorization No. N/A Expiration Date N/A Signed- 4/ Pb'ri, -,- Date 20 0t.Owner or OWner's Degignee, Title " CERTIFICATE OF INSERVICE INSPECTION I, the undersigned.
holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I 1,_ to r-,-r- tz- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss f any kind arising from or connected with this inspection.
/7 7/ Commissions ANw ra t 7aBodtt Inspe'curs signature National Board. State, Province, and Endorsements Dte. I ý''20 `z Date I 20 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 3/29/2012 Sheet: I of I Unit: 2 Program No.: 11-089 WO: 1361867-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Residual Heat Removal, Class 2 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Co ponents Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Pacific Scientific UTC 2900199 N/A 2-1016-A 123 N/A Replacement No I Co.__.7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt ED Other El Pressure _ psi Test Temp. -F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 109040ý , /_:" -" "Date 20 /l Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period is -to IC mb-w- ,7 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section X1.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ -__ _ -__Commissions PR ,'K A w ( It. zL , nspectors Signature National Board, State, Province, and Endorsements Date i MP'20 Rite MAI20 'Z-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 3/29/2012 Sheet: I of I Unit: 2 Program No.: 11-090 WO: 1361871-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Corponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega UTC 2900195 N/A 2-0203-28 N/A Replacement No 7. Description of Work: Replaced snubber.8, Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt [Other E] Pressure _ psi Test Temp.-_ 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear 1OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed O4ýe n4D-itle , Date K//0O 20 /0 Owner or Owner's Destghee, Ttle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i'7 cWt. ,- to [I'M -L , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property amage or a loss of any kind arising from or connected with this inspection.
__ _ _ _ _ _ __ _Commissions vRI3tiS pi.ZZJ IlnspeLtors Signature National Board. State. Province, and Endtrsernents Date i 20 12 Date i r,\bt 2 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, 11. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 4/1/2012 Sheet: I of I Unit: 2 Program No.: 11-091 WO: 1361881-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Rplacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega UTC 2900194 N/A 2-3001-D72 N/A ReMlacement No 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt 0 Other E] Pressure __ .psi Test Temp. _ F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed IF.,Lt" ".).'.' 1 1  +- ,_Date _ _ _/__ _ 20_Owner or Owner'VsDesigneeN,,Title
% D 2 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois., and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i7 t- IR to 2, M-L , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ Commissions PRMlzs Pt pi ,t.zi, f npe.ors Signature National Board. State. Province, and Endorsements Date 1 (,'14 20 1L Date 20 ~-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI i. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: Reactor Recirculation, Class I Date: 4/8/2012 Sheet: I of I Unit: 2 Program No.: 11-092 WO: 1361846-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Pacific Scientific UTC 2900206 N/A 2-0202-B 19 N/A Replacement No Co.__.7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic EL Pneumatic El Nominal Operating Pressure E] Exempt 0 Other rl Pressure _ psi Test Temp. 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Owner o w nýr "0 4 .W4i ,,, Date '____/_-____
20___Owner-or Ow's De§,nee, Title"-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period j7 r-M- V- to Z7 , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__ _ _ _ __ Commissions .nris,r P t w I zzi Inspectors Signature National Board. State, Province.
and Endorsements Dire I MWA 20 i'z._flnte I20 I*L FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: Reactor Recirculation, Class I Date: 4/8/2012 Sheet: I of I Unit: 2 Program No.: 11-093 WO: 1361847-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Pacific Scientific UTC 2900208 N/A 2-0202-B25 N/A Replacement No Co.___.7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic
[I Pneumatic i] Nominal Operating Pressure E Exempt [Other E1 Pressure _ psi Test Temp. 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Oeor e De-gnee, Date Tt20e Owneror Qner' Defgnee, Title -CERTIFICATE OF INSERVICE INSPECTION
: 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 's jtR k' .to 74 M Q , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _-_ _ _Commissions m.,a-is P P Ip--z, n'peýiors Signature National Board, Slate, Province, and Endorsements2 20 IZ Date -7 "1-61 20 '?-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville.
: 11. 60555 Date: Sheet: Unit: 4/8/2012 I of I 2 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: Reactor Recirculation, Class I Program No.: 11 -094 WO: 1361848-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Natl Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or_ _No)Snubber Pacific Scientific UTC 2900207 N/A 2-0202-B24 N/IA Replacement No Co.___.7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic C3 Pneumatic C3 Nominal Operating Pressure CE Exempt [Other El Pressure -psi Test Temp. -F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I 0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 0AV*Z& -3r2- , A-g,.e_,, ' ! ,de- Date 20./ .Owner or Okvner's Detnee, Title -"J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period el' %1- to 71 ,rt,1- .and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ -,_ _ _ _ _ __/ Commissions
".-i, A,.S pi ' IL zZ1 In~flctors Signature National Board, State, Province.
and Endomr.ements Date ?- 20 Iz-Date ' r~,- 20 1-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 3/26/2012 Sheet: I of _1 Unit: 2 Program No.: 11-095 WO: 1361853-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Core Spray, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Corn onents Repaired or Replaced, and Rplacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega UTC 2907667 N/A 2-1403-1 N/A Replacement No 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic D Pneumatic EJ Nominal Operating Pressure El Exempt 0 Other E] Pressure _ psi Test Temp._ 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed .or qO'aa Ala , r" Date 6/f 20 J7 .Owner or Owner's lisignee, Title -a -4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i) M-,P.- %,L to ' r,.9-L%- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propert damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ Commissions tW-1 A ri I ItZ7%, V ---Inspectors Signature National Board, State, Province, and Endorsements I"}nte 70 17_flote2c LP&Vfl 20 1Z FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 3/26/2012 Sheet: I of I Unit: 2 Program No.: 11-096 WO: 1361854-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Core Spray, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Rplacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or -Code No. Replacement Stamped (Yes or Snubber_ _____ _ N/A _1401-9 __ No)Snubber Lisega UTC 2907669 N/A 2-1403-2 N/A Replacement No 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure El Exempt [D Other El Pressure -psi Test Temp._ 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed OwnedAr w 1 'W1D esig,_. ez// Date q Z/ 2Date Owner-or Owner's Deihe, Title -,J 0 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ilt",Pt IL to Z3 (-'X %? , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propert d mage I any kind arising from or connected with this inspection.
Commissions i3vu5 , Y- N IL ZZ'1 n-spectors Signature National Board. State, Province.
and Endorsements Date 30 20 V'*_~Date .?o AM-. 20 r?-
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 3/26/2012 Sheet: I of 1 Unit: 2 Program No.: 11-097 WO: 1361855-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Residual Heat Removal, Class I 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega UTC 2907672 N/A 2-1012-A6 N/A Replacement No 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic 0l Pneumatic El Nominal Operating Pressure CJ Exempt 0 Other [I Pressure -psi Test Temp. 'F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code ,Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 6-, , 4 , Date 1 20 IL Owner or Ofner's De~ignee, Title -3 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois .and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z1 rk_- ks- _ to 8 r- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damageor a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ _ Commissions Ntf A-t I IL_ z7,1 I nspectors Signature National Board, State. Province.
and Endorarments 1"5.ate. to I?.Dt3oAP V- 20 1?
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 3/28/2012 Sheet: I of I Unit: 2 Program No.: 11-098 WO: 1361856-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Residual Heat Removal, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega UTC 2910903 N/A 2-1012-B7 N/A Replacement No 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic F1 Pneumatic El Nominal Operating Pressure El Exempt [Other E] Pressure _ psi Test Temp. -F 9. Remarks: Performed VT-3 on replaced snubber.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed,,-72 h-" .I,,z4 -Ia/r Date Z_/___Owner or Ownefs Designfee, Title , ) _2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period LZ r--K %? to 2 r`0- ,L , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ ________Commissions iqa i5 rS N i It'ZZI)l-, : inW9t~ors Signature National Board, State, Prnvinwe.
and Endorsements~,n i*?.Date 1) avf 20 17 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 5/2/2012 Sheet: I of I Unit: 2 Program No.: 11-099 WO: 1361849-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Reactor Recirculation, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 7. Description of Work: Replaced snubber.8. Tests Conducted:
Hydrostatic 0l Pneumatic El Other [] Pressure _ psi 9. Remarks: Performed VT-3 on replaced snubber.Nominal Operating Pressure E- Exempt ED Test Temp. -'F CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed L4< ' ,,,'Date ,"/kIL 20 J/<Owner or Owner's Design,, Title I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 19 it , to 73 rnk-t it , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____________________________Commissions N ,3,s1 A w t-z-, TIn ors Signature Nalional Board, State. Province, and Endorsements7_.. Da1te Z m1- 20 Mz FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 3/28/2012 Sheet: I of I Unit: 2 Program No.: I 1-100 WO: 1361859-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Residual Heat Removal, Class 2 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 7. Description of Work: Replaced snubber and taper pin.8. Tests Conducted:
Hydrostatic El Pneumatic El Other E] Pressure _ psi 9. Remarks: Performed VT-3 on replaced snubber.Nominal Operating Pressure El Exempt [Test Temp._ 'F CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App2 B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Dateer 12 Dates D20 Owner or Ownet's Designee, Title 1i V CERTIFICATE OF INSERVICE INSPECTION
: 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 13 Arz Q to '1 r",e- ,?_ , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property amage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _ Commissions Pg'i A s it ILUtZL tlnspectors Signature National Board. State. Province.
and Endorrnm ents Date -20 J/
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: High Pressure Coolant Injection, Class 2 Date: 5/29/2012 Sheet: I of I Unit: 2 Program No.: I 1-101. 12-018 WO: 880895-07,01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N-416-3 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Nut Nova UTC 2904538 N/A 2-2306-24" N/A Replacement No Counline Consolidated UTC 2869159 N/A 2-2363-2" N/A Replacement Noo U-bolt Anvil UTC 2883691 N/A 2-2363-2" N/A Replacement No 7. Description of Work: Replaced nuts, couplings, and a u-bolt.8. Tests Conducted:
Hydrostatic El Pneumatic F1 Nominal Operating Pressure [ Exempt El Other E1 Pressure __ psi Test Temp. IF 9. Remarks: None.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section Xl Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed , P Date 20 Owner or Owner's Desighee, Title -- -J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period :_0 r-',,- i. to i0 AM-i , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__ _ __ _ _ __ _ _ __ _ _Commissions
"'L8I3,1, T A P lN , ttI pecors Signature National Board, State, Province, and Endorsements'it 20 Dat 0n 3-20 f FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 5/31/2012 Sheet: I of I Unit: 2 Program No.: 11-102 WO: 1334358-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped S &#xfd;S ...1 (Yes or_ _ 6 N_ _I No)Valve Dresser Industries S/N BK7072 N/A 2-0203-3D N/A Replacement No Stud Nova UTC 289949&%q N/A 2-0203-3D N/A Reolacement No Hydranut Nova UTC 2894161 N/A 2-0203-3D N/A Replacement No 7. Description of Work: Replaced valve and bolting.8. Tests Conducted:
Hydrostatic 0 Pneumatic D Nominal Operating Pressure 0 Exempt El Other [] Pressure -psi Test Temp. -OF 9. Remarks: Performed VT-I on bolting.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed --, ' !., / ate / 20 14 Owner or Owder's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period L-- r-'n. R to '-',- .and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_Commissions itroci- p, p i tL ?za, Inspectors Signature National Board, State. Province, and Endorsements Date 'I h,, 20 1?Dare 1 20 '~
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North. Cordova. IL 61242 Date: 5/30/2012 Sheet: I of I Unit: 2 Program No.: 11-104 WO: 1333556-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Co ponents Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped U~ (Yes or_______ _________
__________
No)Valve Dresser Industries S/N BK7062 N/A 2-0203-3C N/A Reolacement No Stud Nova UTC 289949& N/A 2-0203-3C N/A Replacement No Hydranut Nova UTC 2906827, N/A 2-0203-3C N/A Replacement No 2908998 7. Description of Work: Replaced valve and bolting.8. Tests Conducted:
Hydrostatic
[I Pneumatic El Nominal Operating Pressure [ Exempt El Other El Pressure __ psi Test Temp. -OF 9. Remarks: Performed VT-I on bolting.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed e or e,, C5" Date/ 20 /I Owner or Ofner's Designee, Ti'de CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 4. mrln, L to 3, eX %*c -and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ "_ ___ Commissions Ngti- p A ILLz,'1% ~pectors Signature National Board. State, Province, and Endorsements D'Ite. '7 1&#xfd;20 ! Z-flat~'r *7 2t)
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, fIL 61242 Date: 5/31/2012 Sheet: I of I Unit: 2 Program No.: I-l105 WO: 1351615-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Valve Target Rock S/N 120 N/A 2-0203-3A N/A Replacement No Stud Nova UTC 2877296. 2907414 N/A 2-0203-3A N/A Replacement No Hydranut Nova UTC 2908996, 2906828 N/A 2-0203-3A N/A Replacement No Hex Nut Various UTC 2904187, 2882245 N/A 2-0203-3A N/A Replacement No 7. Description of Work: Replaced valve and bolting.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure ED Exempt El Other [] Pressure _ psi Test Temp. -'F 9. Remarks: Performed VT-I on bolting.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed P-o7% .6 Aw"."rDate 20 /Z Owner or O&#xb6;ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois., and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ZA' Z- I to Ip , 1-, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ ___Commissions N9 1315 A &#xfd; I L7,lii V ln-peiors Signature National Board, State. Province.
and "7 9D I'g.L Dwel~p k- 0 lt FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 5/30/2012 Sheet: I of 1 Unit: 2 Program No.: 11-106 WO: 1334352-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B3 1.1 / ASME Section III Edition: 1967 / 1965 Addenda: N/A / 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and R placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Valve Cons Safety S/N BK6251 N/A 2-0203-4H N/A Replacement No Valve.Stud Nova UTC 2900361 N/A 2-0203-4H N/A Replacement No Hydranut Nova UTC 2908999 N/A 2-0203-4H N/A Replacement No Hex Nuts Accutech UTC 2900506 N/A 2-0203-4H N/A Replacement No 7. Description of Work: Replaced valve and bolting.8. Tests Conducted:
Hydrostatic El Pneumatic 0l Nominal Operating Pressure 0 Exempt El Other E] Pressure _ psi Test Temp. -'F 9. Remarks: Performed VT-I on bolting.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ff/L% _ .
aggA -Date 54___/__ 20 le Owner or Owder's Dlignee, Tit lt I CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z _. to ?I r,,1 t .and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__ _ _ _ _ _ _Commissions P'A -M% A N t iL ZZ,, f &#xfd; spector% Signature Nationul Board. State. Pruvince, and Endorsements Date 7  20  Date 1 13 20 11~
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 5/30/2012 Sheet: I of I Unit: 2 Program No.: 11-107 WO: 1334353-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Main Steam, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 / ASME Section III Edition: 1967 / 1965 Addenda: N/A / 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Valve Cons Safety S/N BL 1120 N/A 2-0203-4G N/A Replacement No Valve Stud Nova UTC 2900361 N/A 2-0203-4G N/A Replacement No Hydranut Nova UTC 2736367 N/A 2-0203-4G N/A Replacement No Hex Nuts Nova UTC 2740332 N/A 2-0203-4G N/A Replacement No 7. Description of Work: Replaced valve and bolting.8. Tests Conducted:
Hydrostatic Dl Pneumatic El Nominal Operating Pressure 0 Exempt El Other El Pressure -psi Test Temp. -F 9. Remarks: Performed VT-I on bolting.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 7- 'L ! , 6,3 ,,,-,,,, Date 5"1,/ 20 /Z Owner or O~Wner's Deignee, Title-CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford.
Connecticut have inspected the components described in this Owner's Report during the period , , to It ,',V , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
6-, Commissions frwlt,'-s A N i IL. zz,,'"tectlors Signature National Board. State. Pnrvince.
and Endorsememn-i v'*.L Date -7 1,, 20 tZ FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 5/29/2012 Sheet: I of I Unit: 2 Program No.: 11-108 WO: 1334351-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B3 1.1 / ASME Section III Edition: 1967 / 1965 Addenda: N/A / 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Valve Cons Safety S/N BK6266 N/A 2-0203-4C N/A Replacement No Valve Stud Nova UTC 2900361 N/A 2-0203-4C N/A Replacement No Hvdranut Nova UTC 2908999 N/A 2-0203-4C N/A Replacement No Hex Nuts Accutech UTC 2900506 N/A 2-0203-4C N/A Replacement No 7. Description of Work: Replaced valve and bolting.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure 0 Exempt El Other El Pressure __ psi Test Temp. -'F 9. Remarks: Performed VT-I on bolting.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section Xl Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed A"'. " &#xa3;', &#xa3;,"Date 5/31 201Z Owner or Owner's ffesignee, TitA CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I._ rh,,i it to It r-,'.[- , , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___L__ _ Commissions t,9135 IL t 'm National Board, State. Pntvince.
and Endorsements Date -7 A 20 la Date ?20 11 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I!. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 4/13/2012 Sheet: I of 1 Unit: 2 Program No.: II- 117 WO: 1359120-01 v Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1955 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re lacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Plug and Stem Crane UTC 2848733 N/A 2-0203-2B N/A Replacement No Assembly _ 1 .1 1_1_.11 7. Description of Work: Replaced plug and stem assembly.8. Tests Conducted:
Hydrostatic E] Pneumatic 10 Nominal Operating Pressure E] Exempt Q]Other E] Pressure _ psi Test Temp. -'F 9. Remarks: None.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code. Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear 1OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ,)- Tit-l-1 ( Date _-_/[ 20 /Owner or Owner's Degignee, Title " CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HLSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z-- 7 ,,Z v_ to 3 ame 7- I, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
______- ______ __ _ Commissions
?tig t-t-s 4 N 4 itt_'Jti Y Inspectors Signature National Board. State, Province, and Endorsements 20 17, Dat 2' P'-6 20 12-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield RoadWarrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: Main Steam, Class I Date: 6/7/2012 Sheet: I of I Unit: 2 Program No.: I I-1 18 WO: 1115612-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1955 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Plug & Stem Crane UTC 2681932 N/A 2-0203-1 B N/A Replacement No Assembly I I 1 _7. Description of Work: Replaced plug and stem assembly.(,nllests Conducted:
Hydrostatic E- Pneumatic ED Nominal Operating Pressure El Exempt El Other [] Pressure _ psi Test Temp. -F 9. Remarks: LLRT performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code .Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed - e'X ', Avext&-ir
/4 ota; fDate 6/IS 20 Owner or Owner's l9esignee, Title.)CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB C7. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z? %._ Z to Z , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________
_________Commissions -atc n 75 f P L- ,, In pelors Signature National Board. Stlae, Province, and Endorsements
__ _ _ _ __,-, 20 mL FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI i. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: NWS Technologies 131 Venture Blvd.. Soartanburg.
SC, 29306 Date: 3/1/2012 Sheet: I of /Unit: 0 Program No.: I 1-122 WO: P.O. 475200 RIN 206595 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: ASME Section III Edition: 1968 Addenda: Winter 1968 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Target Rock Valve Target Rock 225 N/A UTC 2887058 N/A Repair No I_ I I Replacement
: 7. Description of Work: Drilled two thermowells and machined inlet / outlet face and tongue.8. Tests Conducted:
Hydrostatic El Pneumatic DJ Nominal Operating Pressure El Exempt El Other E] Pressure _ psi Test Temp. _ 'F 9. Remarks: An internal VT-3 examination performed.
Pressure test to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section Xl Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 20,1ZK-i C A Date /Oi-e.Owner or Ofner's D8ignee, Title -f CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois _ and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i- r t7 I to IS ,r,.. "t? , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions 1.jtnrns A N i iL insp l signature National Board, State, Province, and Endorsements Date 19 r,-,v,- 20 R-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: NWS Technologies 131 Venture Blvd., Spartanburg, SC, 29306 Date: 3/l/2012 Sheet: I of I Unit: 0 Program No.: 11-124 WO: P.O. 478898 RIN 206594 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: ASME B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Co ponents Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Electromatic Relief NWS BK07072 N/A UTC 2056410 N/A Repair / No Valve Technologies I _ _ _ Replacement
: 7. Description of Work: Removal of cracked cage welds and helical-coil repairs.8. Tests Conducted:
Hydrostatic El Pneumatic F] Nominal Operating Pressure El Exempt E]Other [] Pressure __ psi Test Temp. OF 9. Remarks: An internal VT-3 examination performed.
Pressure test to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 9,V Date Z20 /20 CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois _ and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Il,, IZ to ? V,,- ,. , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
KCommissions Nk 131" A I4 N IL Z'tZ Inspectors Signature National Board, State, Province, and Endorsements I[ Date 20 I Date 8'"bt 20 M~
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: NWS Technologies 131 Venture Blvd., Spartanburg, SC, 29306 4. Identification of System: Main Steam, Class I Date: 3/1/2012 Sheet: I of I Unit: 0 Program No.: I 1-125 WO: P.O. 478898 RIN 206594 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: ASME Section III Edition: 1995 Addenda: 1996 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Electromatic Relief Dresser BY94632 N/A UTC 2712404 N/A Repair / No Valve Reolacement
: 7. Description of Work: Removal of cracked cage welds and machined inlet flange face.8. Tests Conducted:
Hydrostatic
[l Pneumatic El Nominal Operating Pressure E] Exempt EL Other Ej Pressure _ psi Test Temp. -OF 9. Remarks: An internal VT-3 examination performed.
Pressure test to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code .Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed o a-L , , Aq/bn 6-1 , Date 20 /.Owner or Owndr's Desrgnee, Title -CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i- 5,t to Is m %,L , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
..._..... _ Commissions HRlMIlS A Ni (Lrtt 7inspectors Signature National Board. State. Province, and Endorsements Date i 5" 20 12-Date IS' fs~n~ 20 IL FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: NWS Technologies 131 Venture Blvd., Spartanburg, SC, 29306 4. Identification of System: Main Steam, Class I Date: 3/1/2012 Sheet: I of I Unit: 0 Program No.: 1 1-128 WO: P.O. 475203 RIN 206588 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: ASME B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Main Steam Safety Consolidated BK6264 N/A UTC 2070092 N/A Repair I No Valve Safety Valve Div. Replacement
: 7. Description of Work: Replaced valve body / base assembly.8. Tests Conducted:
Hydrostatic EU Pneumatic EU Nominal Operating Pressure EU Exempt U Other [] Pressure _ psi Test Temp. -F 9. Remarks: An internal VT-3 examination performed.
Pressure test to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Prlj 1!,,i /, .Date 20ffi, Owner or Owner's Designee, Tit'CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois .and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period &#xfd;r'e I? to ?'x'V- -z , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ _ _ _ _ _ _'_ _ _ _ _ _ Commissions tJA 1705S Aril t. zzl'-'i spectors Signature National Board. State, Provi.ce, and Endorsements Date ? fl 20 JL..
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, Ii. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Wyle Laboratories 7800 Hi2hwav 20 West. Huntsville.
AL Date: 2/28/1012 Sheet: I of I Unit: 0 Program No.: 12-003 WO: P.O. 00482065; RIN 206149 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Spare Snubber, Class 16 d .3/1//Z 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Com ponents Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega S/N 61293/98 N/A N/A N/A Repair / No I I Replacement
: 7. Description of Work: Replaced threaded head assembly.8. Tests Conducted:
Hydrostatic 0 Pneumatic El Nominal Operating Pressure E] Exempt 0 Other r_1 Pressure _ psi Test Temp. -'F 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ?52/:" 70/W4. P ,,i & , AZ,,- Date ,/I 20 Lv.Owner or O%&#xfd;ner's DMignee, Title" Aj CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois .and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period bE- t , to !a 3 '&#xfd; i- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _./__ _ _Commissions r igsli ANI .LM-'"-&#xfd; spectors Signature National Board, State, Province, and Endorsements Date I  20 11 Date I 20 ivt FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Wyle Laboratories 7800 Highway 20 West, Huntsville, AL Date: 2/28/2012 Sheet: I of /Unit: 0 Program No.: 12-004 WO: P.O. 00482065; RIN 206149 Repair Organization P.O. No.. Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Spare Snubber, 6,1_..$ 1 13/v 5. (a) Applicable Construction Code: USAS B3 1. 1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber [ S/N 61293/101 N/A N/A N/A Repair/ No SI Replacement.
: 7. Description of Work: Replaced threaded head assembly.8. Tests Conducted:
Hydrostatic El Pneumatic E3 Nominal Operating Pressure El Exempt [Other E] Pressure __ psi Test Temp. -OF 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed C"Z---,''
P'vma -,r Date -/I 20 .Owner or Owner's Oesignee, Tit!e I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i 1X*', to 'o a z- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section Xl.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or port damage or a loss of any kind arising from or connected with this inspection.
__ ___ Commissions OR %NI A l, jT-"--'I [nspectors Signature National Board, State, Province, and Endorsements Date ' 1`1. 20 (Z-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Wyle Laboratories 7800 Highway 20 West, Huntsville, AL 4. Identification of System: Spare Snubber, i4a 55 / t Date: 2/28/2012 Sheet: I of 1 Unit: 0 Program No.: 12-005 WO: P.O. 00482065; RIN 206149 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega S/N 61300/61 N/A N/A N/A Repair / No I __ Replacement
: 7. Description of Work: Replaced threaded head assembly.8. Tests Conducted:
Hydrostatic El Pneumatic El Nominal Operating Pressure E] Exempt Z Other [] Pressure _ psi Test Temp. 'F 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I0CFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Own.r o ,,, ," 6y 144 Date Z/21 20 Z, Owner or Owner'9 Desitgffee, Title- I#CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period I bc it to ;-7 3-,' , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code. Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__ /__ Commissions ilnnl A ", tL71,,-s Inspectors Signature National Board, State. Province.
and Endorsements 20 IZ fl~t~ (~n.20 17 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I!. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Wyle Laboratories 7800 Highway 20 West, Huntsville, AL Date: 2/28/2012 Sheet: I of _1 Unit: 0 Program No.: 12-006 WO: P.O. 00482065; RIN 206149 Repair Organization P.O. No.. Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Spare Snubber, a.ss_1 dil / L 2.5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 7. Description of Work: Replaced threaded head assembly.8. Tests Conducted:
Hydrostatic F1 Pneumatic El Other E] Pressure __ psi Nominal Operating Pressure E] Exempt 0 Test Temp. OF 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 4--" C__; i e -',J D4 Date Z/Z- 20 1 ..Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 2n 1, to Irl,1 1- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ __ aCommissions 0?k 4 s v t.uti I " .gnature National Board, State. Province.
and Endorsements l')ate l 20 11, Date I m-kr 0I FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Wyle Laboratories 7800 Highway 20 West, Huntsville, AL 4. Identification of System: Spare Snubber, C f4 55 Date: 2/28/2012 Sheet: I of I.Unit: 0 Program No.: 12-007 WO: P.O. 00482065:
RIN 206149 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 13#31,1 M/'5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisegna S/N 61300/67 N/A N/A N/A Repair / No Replacement
: 7. Description of Work: Replaced threaded head assembly.8. Tests Conducted:
Hydrostatic El Pneumatic Dl Nominal Operating Pressure El Exempt [Other E] Pressure _ psi Test Temp. -F 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -,V -'y , /k,3*,,, 1/4t, Date-;;?/
20 /Z Owner or Owndr's Desiga4*e, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z9 WV to (q 1ht, tI- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or ayss of any kind arising from or connected with this inspection.
sigatr NCommissions Ata oa .to Yinspectors Signature National Board. State, Province, and Endorsements Date I Mxh%_20 Date f\ ~20 12 FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Wyle Laboratories 7800 Highway 20 West, Huntsville, AL 4. Identification of System: Spare Snubber, Class I Date: 3/05/2012 Sheet: I of I Unit: 0 Program No.: 12-008 WO: P.O. 00482065; RIN 206149 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega S/N 61300/68 N/A N/A N/A RRepair / No Replacement
: 7. Description of Work: Replaced threaded head assembly and cylinder.8. Tests Conducted:
Hydrostatic El Pneumatic 0 Nominal Operating Pressure [ Exempt 1Z Other E1 Pressure __ psi Test Temp. -F 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ., Date 3/7 20 17 Owner or Uwher's 1Msignee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 3&#xfd; k,4 1 to P -M 0 A7, , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
___Commissions i.rW\ls A &#xfd;, t. Ilt-. '-41,c r, Signature National Board, State. Province, and Endormments Date 7 MW 20 F0-7M NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Wyle Laboratories 7800 Highway 20 West, Huntsville, AL 4. Identification of System: Spare Snubber, Class I Date: 3/05/2012 Sheet: I of I Unit: 0 Program No.: 12-009 WO: P.O. 00476651; RIN 206418 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B31.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Corponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Snubber Lisega S/N N/A N/A N/A Repair / No I _-_._6-5__
_ _ _ "__8- I Replacement
: 7. Description of Work: Replaced threaded head assembly.
4 0e- IL.. 7'- r7 '8. Tests Conducted:
Hydrostatic El Pneumatic 0 Nominal Operating Pressure [ Exempt 0 Other n Pressure _ psi Test Temp. -F 9. Remarks: Functional test. VT-3 to be performed post-installation.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed Owner er'sesge 6 Iq ate 3 20 JZ.Owner of Owner's Des ignee, TitM CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ' 'x,a Iz to 0Jo it- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_____Commissions &#xfd; -t-1 i 7,1 nspectors Signature National Board, State. Province, and Endorsements 20 Il.Date '7 NrL 20 17-FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: Main Steam, Class I Date: 6/7/2012 Sheet: I of I Unit: 2 Program No.: 12-011 WO: 776083-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1955 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Plug & Stem Crane UTC 2910951 N/A 2-0203-2D N/A Replacement No Assembly 7. Description of Work: Replaced plug and stem assembly.mests Conducted:
Hydrostatic 0l Pneumatic 0 Nominal Operating Pressure El Exempt El Other El Pressure _ psi Test Temp. -F 9. Remarks: LLRT performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair/ Replacement conforms to the rules of ASME Code, Section Xl Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed -#W'*L 2 Pr-q ," A _a.avIv -1Aowd,, wDate 20 1Z Owner or Owner's Designee, Titte /'CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ?:-, -to Z. -, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_________________________________Commissions ItI A P LI I fp torsSigntureNatkotal Board, State. Province.
and Endor~mentent A ___If ______________
20 _____
FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI 1. Owner: I3 Exelon Generation Company, LLC 4300 Winfield Road Warrenville, I1. 60555 Date: 6/7/2012 Sheet: I of I Unit: 2 Program No.: 12-012 WO: 1524727-01 Repair Organization P.O. No., Job No., etc.2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 4. Identification of System: Main Steam, Class I Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1955 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N/A 6. Identification of Components Repaired or Replaced, and Re placement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Plug & Stem Crane UTC 2703687 N/A 2-0203-IA N/A Replacement No Assembly 7. Description of Work: Replaced plug and stem assembly.KD ests Conducted:
Hydrostatic El Pneumatic 0 Nominal Operating Pressure F] Exempt El Other [] Pressure __ psi Test Temp. IF 9. Remarks: LLRT performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section Xi Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 1. .444L -a', /4 ,q,?,,-Date 6 1Z 20 IP Owner or Owder's Defgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period &#xfd;!s ( I to t_,AM__-_ , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_____Commissions HwtIsA N I , i, Z".Natkrnal Board, State, Pnvince. and Endursements (4Ju~ 20 (z FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road Warrenville, II. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Ouad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 Date: 6/7/2012 Sheet: I of I Unit: 2 Program No.: 12-013 WO: 1319135-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: None Authorization No.: None Expiration Date: N/A 4. Identification of System: Feed Water, Class 1 5. (a) Applicable Construction Code: USAS B3 1.1 Edition: 1967 Addenda: N/A Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 Code Case: N-416-3 7. Description of Work: Replaced seat ring assembly.ftests Conducted:
Hydrostatic F1 Pneumatic ED W Other E] Pressure _ psi Nominal Operating Pressure El Test Temp. 'F Exempt El 9. Remarks: LLRT performed.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code , Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear IOCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed 0 dna/- 6 97Dt 20/7-Owner or Owner's Desi ee, Title -.* T ---CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT, f Hartford, Connecticut have inspected the components described in this Owner's Report during the period ---' M-,, % to Z W',Z , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_ _ _ __I_____________a____
Commissions A )r, t.zz,, Insecor SignNational Board, State, Province, and Endorsements,o 20 fz FORM NIS-2 OWNERS REPORT OF REPAIR OR REPLACEMENT As Required by the Provisions of ASME Code Section XI I. Owner: Exelon Generation Company, LLC 4300 Winfield Road 91 Warrenville, I!. 60555 2.Plant: Quad Cities Generating Station 22710 206th Ave. North, Cordova, IL 61242 3. Work Performed by: Quad Cities Generating Station 227 10 206th Ave. North. Cordova. IL 61242 Date: 6/11/2012 Sheet: I of 1 Unit: 2 Program No.: 12-021 WO: 1529316-01 Repair Organization P.O. No., Job No., etc.Type Code Symbol Stamp: Authorization No.: Expiration Date: None None N/A 4. Identification of System: Main Steam, Class I 5. (a) Applicable Construction Code: Section III Edition: 1965 Addenda: Summer 1965 Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements:
Edition: 1995 Addenda: 1996 N-405-1 Code Case: N-416-3, N-638-4.6. Identification of Co ponents Repaired or Replaced, and Replacement Components:
Name of Name of Mfrs. Ser. Nat'l Other Year Repaired, ASME Component Mfr. No. Bd. Identification Built Replaced, or Code No. Replacement Stamped (Yes or No)Nozzle AREVA UTC 2912572 N/A 2-Ni 1B N/A Replacement No Reducer Coupling Various UTC 2912360 N/A 2-NI iB N/A Relacement No 7. Description of Work: Replaced nozzle and reducer coupling.(Ists Conducted:
Hydrostatic C1 Pneumatic C3 Nominal Operating Pressure 0 Exempt El Other El Pressure _ psi Test Temp. -F 9. Remarks: None.CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and this Repair / Replacement conforms to the rules of ASME Code, Section XI Type of Code Symbol Stamp N/A -Exelon Nuclear I OCFR50 App B. 0 A Program Certificate of Authorization No. N/A Expiration Date N/A Signed ' P,"e. i, 'Date 20j/Owner or Owner's Diesignee, Titl el CERTIFICATE OF INSERVICE INSPECTION
: 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Illinois , and employed by HSB CT. of Hartford, Connecticut have inspected the components described in this Owner's Report during the period -I ,ll to h-,- , and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective measures described in this Owner's Report in accordance the requirements of the ASME Code, Section XI.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
________________Commissions MT',is Aw ,tz.-,L ln'rectors Signature National Board. State. Province.
and Endcorements 20 17-/5, 20 It}}

Latest revision as of 06:45, 12 April 2019