ML12271A461: Difference between revisions
StriderTol (talk | contribs) Created page by program invented by StriderTol |
StriderTol (talk | contribs) Created page by program invented by StriderTol |
||
| Line 1: | Line 1: | ||
# | {{Adams | ||
| number = ML12271A461 | |||
| issue date = 04/28/2011 | |||
| title = Enclosure 23 to ULNRC-05893 - Callaway 2010 Air Emission Report | |||
| author name = Whitworth S C | |||
| author affiliation = Ameren Services Co | |||
| addressee name = Kavanaugh J L | |||
| addressee affiliation = NRC/NRR, State of MO, Dept of Natural Resources | |||
| docket = 05000483 | |||
| license number = NPF-030 | |||
| contact person = | |||
| case reference number = ULNRC-05893 | |||
| document type = Letter | |||
| page count = 30 | |||
}} | |||
=Text= | |||
{{#Wiki_filter:Ameren Services ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: | |||
April 28, 2011 Mr. James L. Kavanaugh Department of Natural Resources Air Pollution Control Program P.O. Box 176 Jefferson City, MO 65102-0176 Re: 2010 Emission Inventory Questionnaire | |||
==Dear Mr. Kavanaugh:== | |||
Enclosed are signed copies of EIQ Form 1.0 for seventeen (17) Ameren facilities. Ameren has submitted the EIQs electronically using the MOEIS software. | |||
Emissions fees in the amount of $1,463,816.00 have been deposited in the MDNR account via electronic funds transfer. | |||
Ameren Corporation facilities reported are: | |||
* Callaway Plant | |||
* Fairgrounds Combustion Turbine | |||
* Kirksville Combustion Turbine | |||
* Labadie Plant | |||
* Meramec Plant | |||
* Mexico Combustion Turbine | |||
* Moberly Combustion Turbine | |||
* Moreau Combustion Turbine | |||
* Rush Island Plant | |||
* Sioux Plant | |||
* Peno Creek Combustion Turbine | |||
* Lakeside Works Headquarters | |||
* Columbia Combustion Turbine | |||
* Audrain Combustion Turbine | |||
* Taum Sauk Plant (#0032) (#0584, 0585,0586,0621,0633 did not operate in 2010} | |||
* Howard Bend Combustion Turbine | |||
* Viaduct HAPS emissions will be based on the Toxic Release Inventory (TRI) report. The EIQ reports will be revised by the end of July. Questions concerning the information contained in these reports should be directed to me at 314-554-4908. | |||
Sincerely, , 1 Manager Environmental Services T 314.554.4908 F 314.554.4182 swhitworth@ameren.com Ameren Services As Affi/IMed Agent for Union Electric Company d/b/a Ameren Miuouri & Ameren Energy Generating Company Enclosures | |||
........................................................................................................... | |||
*********************************************************************************************************** | |||
........................................................................................................... | |||
********************************************************************************************************** | |||
* *********************************************************************************************************** | |||
*********************************************************************************************************** | |||
1901 Chouteau Avenue PO Box 66149 , MC 602 St.lou i s , MO 63166-6149 Ameren.com bee cover letter only: D. F. Cole M. W. Litzinger/0. | |||
K. Wenk M.C. Birk MLM/SCW/KJNDKW AQ 5.2.6 0.-\aitVJkvll\tlmiSaion | |||
/etters\2010 Eml$sion Inventory Questionnaire | |||
.doc) bee cover letter & facility enclosures: | |||
A C Heflin (Callaway) | |||
: 0. L. Lomax (CTGs-except Columbia) | |||
T. E. Lafser/D. | |||
K. Wenk (Rush Island) K.P. Blank/M. J. Tomasovic (Sioux} D. L. Strubberg/M. | |||
J. Tomasovic (Labadie) | |||
R. H. Deberge (Peno Creek; Audrain) B. L. Schuh (Columbia CT) W.A Witt (Osage) AQ 5.2.1 (Callaway) | |||
AQ 5.2.2 (CTGs) AQ 5.2.4 (Labadie) | |||
AQ 5.2. 7 (Rush Island) AQ 5.2.8 (Sioux) AQ 5.2.10 (Taum Sauk, Lakeside WHO) AQ 5.2.20 (Columbia CT) DKW (ALL) 2010 Emission Fee Summary Power Plants | |||
* Callaway $ 1200 | |||
* Labadie 441,160 | |||
* Maramec 340,896 | |||
* Rush Island 328,720 | |||
* Sioux 346,920 Combustion Turbines | |||
* Kirksville | |||
$ 40 | |||
* Fairgrounds 40 | |||
* Columbia 40 | |||
* Audrain 1560 | |||
* Mexico 40 | |||
* Moberly 320 | |||
* Moreau 40 | |||
* Peno Creek 2720 | |||
* Viaduct 40 | |||
* Howard Bend 0 Lakeside Works Hdqtrs 40 Taum Sauk Plant 40 TOTAL $1,463,816 MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 1.0 GENERAL PLANT INFORMATION D Request Confidentiality -He Instructions to Initiate the confidentiality request. FACIUTY NAME FIPS COUNTY NO. PlANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT FACILITY STREET ADDRESS COUNTY NAME MISSOURI HWY CC CALLAWAY CITY ZIP CODE ** PHONE NUMBER WITH AREA CODE EXT. FULTON 63166-0000 573-676-8769 FACILITY MAILING ADORESS CITY PO BOX620 PORTLAND YEAR OF DATA 2010 FAX NUMBER WITH AREA CODE STATE IZIPCOO E** MO 65251 | |||
* 0000 FACIUTY CONTACT NAME FACILITY CONTACT TITLE FACIUTY CONTACT E.f.IAIL WHERE TO SEND EIQ IN FUTURE (CHECK ONE) ADAM HEFLIN SR VICE PRESIDENT aheflin@ameren.com F a cil ity Ma ilin g Address 0 Pa r ent Company Mai l ing Addreu PRODUCT/PRINCIPAL ACTMTY SIC NAICS NUWIER OF EMPLOYEES ELECTRICITY 4911 221113 510.00 LA"']JUDE LONGITUDE UTM COORDINATES DEGREES 38 -91 ZONE EASTING(M) | |||
NORTHING(M) | |||
ACC(M) HORIZONTAL DATUM (Ched< Ono) 15N 605259.195 4290680.718 15.0 MINU T ES 45 47 0 NAD27 0 WGS84 SECONDS 30.8088 18.7656 PARENT COMPANY NAME PHONE NUMBER WITH AREA CODE EXT. FAX NUMBER AMERENCORP 314-554-4908 MAILING ADDRESS CITY STATE ZIP CODE+* PO BOX 66149 MC-602 SAINT LOUIS MO 63166-0000 CONTACT PERSON NAME CONTACT PERSON TITLE CONTACT PERSON E-MAIL COUNTRY STEVE WHiiWORTH scwhitworth@ameran | |||
.com UNITED STATES PLANT EMISSIONS FROM FORM 3.0 (tONS PER YEAR) II PM10 JSOx NOx (we leo rEAD HAPa IPM25 INH3 0.70 6.72 22.03 0.62 4.92 0.00 0.00 0.00 0.00 The undersigned hereby certifies that they have personally examined and are familiar with the information and statements contained herein and further certifies that they believe this Information and statements to be true, accurate and complete. | |||
The undersigned certifies that knowingly making a false statement or miareprasentlng the facts presented in this document Is a violation of state law. PRINT NAME OF WENt-TITLE 'EJJ 6 (L SIGNATURE I! | |||
WtMffi_ DATE 4.J !'* If CHECK/AUTH | |||
.NO. PRINT NAME OF AUTHORIZED COMPANY REPRESENTATIVE TITLE PAYMENT DATE J!1 ( C H /h'5 L. /-, /"!-£. ,W H*. 1/l'-- | |||
SIGHATUR( .J-.. ./_. DATE t:;.Y-27-11 7/Z. .., 9 | |||
.. | |||
,. OPFICa UU OHLY Missouri Department of Natural Resources I.OGGI!D IN .-/l DATE Pollution Control Program 1659 E. Elm St. | |||
City, Mo 65101 573-751-4817 www.dnr.mo.gov/env/apcp/moels/emlssionsreportlng.htm | |||
' eiq@dnr.mo.gov . MO (12-o&) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 1.0 GENERAL PLANT INFORMATION D Request Confidentiality -see instructions to initiat e the confidentiality request. FACILITY NAME FIPS COUNTY NO. PLANT NO. YEAR OF DATA AMEREN MISSOURI 027 0026 2010 CALLAWAY NUCLEAR POWER PLANT FACILITY STREET ADDRESS COUNTY NAME MISSOURI HWY CC CALLAWAY CITY ZIP CODE+ 4 PHONE NUMBER W ITH AREA CODE EXT. FAX NUMBER WITH AREA CODE FULTON 63166-0000 573-676-8769 FACILITY MAILING ADDRESS CITY STATE ZIP CODE+ 4 PO BOX 620 PORTLAND MO 65251 -0000 FACILITY CONTACT NAME FACILITY CONTACT TITLE FACILITY CONTACT E*MAIL WHERE TO SEND EIQ IN FUTURE (CH ECK ONE) ADAM HEFLIN SR VICE PRESIDENT ahefiin@ameren.com | |||
[8] Facility Mailing Address D Parent Company Mailing Address PRODUCT/PRINCIPAL ACTIVITY SIC NAICS NUMBER OF EMPLOYEES ELECTRICITY 4911 221113 510.00 LATITUDE LONGITUDE UTM COORDINATES DEGREES 38 -91 ZONE EASTING (M) NORTHING(M) | |||
ACC(M) HORIZONTAL DATUM (Check One) 15N 605259.195 4290680.718 15.0 MINUTES 45 47 D NAD27 D WGS84 30.8088 18.7656 (8] NAD83 SECONDS PARENT COMPANY NAME PHONE NUMBER WITH AREA CODE EXT. FAX NUMBER AMEREN CORP 314-554-4908 MAILING ADDRESS CITY STATE ZIP CODE +4 PO BOX 66149 MC-602 SAINT LOUIS MO 63166-0000 CONTACT PERSON NAME CONTACT PERSON TITLE CONTACT PERSON E-MAIL COUNTRY STEVE WHITWORTH scwhitworth@ameren.com UNITED STATES irOTAL PLANT EMISSIONS FROM FORM 3.0 (TONS PER YEAR) PM10 I SOx NOx lvoc leo I LEAD HAPs I PM25 I NH3 0.70 6.72 22.03 0.62 4.92 0.00 0.00 0.00 0.00 The undersigned hereby certifies that they have personally examined and are familiar with the information and statements contained herein and further certifies that they believe this information and statements to be true , accurate and complete. | |||
The undersigned certifies that knowingly making a false statement or misrepresenting the facts presented in this document is a violation of state law. PRINT NAME OF PERSON COMPLETING FORM TITLE PAYMENT AMOUNT SIGNATURE DATE CHECKIAUTH.NO. | |||
PRINT NAME OF AUTHORIZED COMPANY REPRESENTATIVE TITLE PAYMENT DATE SIGNATURE DATE INFORMATION OFFICE USE ONLY Missouri Department of Natural Resources LOGGED IN BY DATE Pollution Control Program 1659 E. Elm St. | |||
City, Mo 65101 f573-751-4817 MO 780-1431 (12-09) | |||
FACILITY NAME MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 1.2 | |||
==SUMMARY== | |||
OF EMISSION UNITS AND RELATED PROCESSES FIPS COUNTY NO. PLANT NO. YEAR OF DATA AMEREN MISSOURI 027 0026 2010 CALLAWAY NUCLEAR POWER PLANT INSTRUCTIONS If all emissions are below the reporting threshold, mark below as "Insignificant", and do not report on Forms 2.0 and 3.0. If one pollutant exceeds the reporting threshold, mark below as "Active" and report all pollutants on Forms 2.0 and 3.0. REPORTING THRESHOLD Pollutant PM10 SOx NOx voc co CATEGORY1 CATEGORY2 PM2.5 NH3 HAPs HAPs Threshold (lbs.) 876 2,000 2,000 876 2 , 000 20 200 876 876 Threshold (tons) 0.438 1.0 1.0 0.438 1.0 0.01 0.1 0.438 0.438 EMISSION UNIT NO. EMISSION UNIT DESCRIPTION OPERATING STATUS (CHOOSE ONE) sec (USE SAME DESCRIPTION ON FORM 2.0) Active Inactive Dismantled Under Construction Insignificant B-01 0 0 0 0 AUXILIARY BOILER 10200501 B-02 [g] D D D D EMERGENCY DIESEL GENERATOR A 20200402 B-03 [g] D D D D EMERGENCY DIESEL GENERATOR B 20200402 B-04 [g] D D D D SECURITY EMERGENCY GENERATOR 20200402 B-05 [g] D D D D TSC EMERGENCY GENERATOR 20200402 B-06 [g] D D D D EOF EMERGENCY GENERATOR 20200402 B-07 [g] D D D D FIRE PROTECTION DIESEL GENERATORS (2) 20200402 B-10 [g] D D D D PORTABLE DIESEL GENERATOR 20200402 B-12 [g] D D D D 4 Permanent Diesel Generators 20200402 B-13 [g] D D D D 5 Temporary Diesel Generators 20200402 Only emission units marked "Active" on this page will have their associated Form 2.0 and worksheet information displayed in this PDF document. | |||
MO 780-1620 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACI LI TY NAM E FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E M I SS I ON UN I T NO. I E M I SS I ON UNIT DESCR I PT I ON B-01 AUXILIARY BO I LER 2. EMISSION PROCESS DETAIL SEG. NO. I SOURC E CLASSIFICATION COD E (SCC) SCC D E SCR I PT I ON 1 10200501 PLAN T NO. Y E AR OF DATA 0026 2010 Grades 1 and 2 Oil DO THE E MISS I ONS F ROM THIS E MISSION UNIT F L OW THROUGH A STACK OR VENT? [8j Yes D No IF YES, COMPLETE FORM 2.0S STACKNENT I NFORMATION AR E TH E E MISSIONS FROM TH I S UNIT FUGIT I VE? D Yes [8j No IF FUG I TIVE , WHAT P E RCENTAGE? | |||
: 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS A NN UA L THROUGHPUT UNITS DE C-FEB (%) For coal or fuel oil , list details below 1.00 364.81 1 000 GALLONS MAR-MAY(%) | |||
Heat Con lent (BT U/Fuel Unit) 98.00 137 , 000 , 000.00 HOURS/DAY D AYS/W EE K WEEKS/YEAR TOTA L HOURS/Y E AR JUN-AUG (%) ASH % (INC L U D E IN E F) 1.00 0.00 24.00 7.00 52 8 , 736.00 S EP T-NOV (%) SULFUR% (INC L UD E IN EF) 0.00 0.04 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL x Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 =Actual Emissions (tons) I n s tru c ti ons: Choose from the Lbs l unit of lhroughpul If EF includes control Combination of all I f controlled, include List Othe r Worksheets or Source of E mission mark"C" , capture and Form 2.0C Control AP-42/0ther Refe r ence Factor list otherwise "U" destruc ti on D evice Listing at lower right efficiencies PM10 FIL | |||
* 4F 1.0000 No Control 0.00 0.18 SOURCE OF EMISSION FACTOR LIST SOx 4F 6.2480 No Control 0.00 1.14 1.CEM I n c lu de doc um e nt atio n 2. Stack Test I n c lu de doc um e nt atio n NOx 4F 20.0000 No Control 0.00 3.65 3. Mass Ba l ance I n c l ud e docu m e nt at i on 4. AP-42 I nc l ude r efe r e n ce voc 4F 0.2000 No Control 0.00 0.04 4F. FIRE or webFIRE 5. Other In c l ude doc um e nt ation co 4F 5.0000 No Control 0.00 0.91 EC. Engr Calc In c lu de doc um en t a t ion LS. Landfill Spdsht I nclude docu m e ntati o n LEAD TK. TANKS Program Suppl y TANK S o utpu t 2.3. VOC Mass Sal Comp let e F onm 2.3 HAPs 2T 0.0000 No Control 0.00 0.00 2.4. Liquid Loading Complet e F onm 2.4 2.7. Haul Road Co mp lete F o r m 2.7 PM2.5 FIL | |||
* 2.8. Storage P i le C o mpl ete Fonm 2.8 2.T. HAP Worksheet C o mp lete F o nm 2.T NH3 2.9. Stack TesUCEM Com pl e t e F onm 2.9 2.0L. Landfill Co mp le t e F onm 2.0 L PM CON* | |||
* If PM CON is reported, P M10 and P M25 entries above are required and should represent only the filterable PM1 0 and filtera b le PM25. MO 780-1621 | |||
DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.T HAZARDOUS AIR POLLUTANT WORKSHEET A G ILIT Y NA ME f,MEREN MISSOURI E MI SS I O N U N I T N O. B-01 F I PS COUNTY NO. PLANT N O. E A R OF DAT A 027 0026 2010 p;OURCE CLASS IF ICA TI ON CODE (SCC) EG. N u. 10200501 1 Use this form to report any Hazardous Air Pollutant, or HAP, which is emitted in any amount greater than the chemical reporting levels per each emission unit. The instructions for this form provide a list of the HAPs regulated under the Clean Air Act. The amount emitted (Column 4) should be reported before control equipment reductions are applied. Provide documentation (other worksheets, etc.) if the amount in Column 3 does not equal the amount in Column 4. The HAP reporting levels per emission unit are as follows: Category 1 HAPs-sum of 20 pounds per year; All other HAPs -sum of 200 pounds per year. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. H AP CHEMICAL C A S NU MB E R AMOUN T USED OR U NCONTROLLED UNCONTROL L ED U NCON T ROL L E D EMISSIONS HAP CON T RO L DEVICE(S) | |||
CONTRO L CONTROLLE D EMISS I ONS CON T ROLLED E M I SSIONS H A N DLED (L B S./YR.) AMOUNT E M I TIE D EM I SS I ONS REPORTE D RE P ORTED A S HAPs (LBS./YR.) EFFIC I ENCY(%) REPORTE D A S VOC OR REPOR TE D AS H APs (L B S./YR.) AS VOC OR P M 1 0 PM 1 0 (LB S./YR.) (LBS./YR.) (LB S./YR.) S U M (L B S./YR. S U M (L B S./YR. S UM (LB S./YR. SUM (LBS./YR.) HAP Emission Totals= 0.00 0.00 0.00 0.00 Sum of uncontrolled emissions reported as HAPs 11. HAP EMISSION FACTOR Uncontrolled HAP Emission Factor= (Column 6 Totai)/Annual Throughput (Form 2.0) 0.0 Enter the HAP emission factor for all chemicals that are not reported as VOCs or PM1 0 from Block 11 above as the HAP Emission Factor in Section 5 on Form 2.0. M O 7 80-14 48 (1 2-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) B-01 10200501 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL AUXILIARY BOILER 09/04/1984 COMBUSTION ENGINEERING TYPE 18-A-13 2. OPPOSED 3. FRONT 4. DRY/WET BOTTOM OTHER (SPECIFY) | |||
Y EAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 123.000000 Sum of total maximum hourly design rates 123.0000 COMBUSTION EQUIPMENT USE (CHECK ONE) D Electric power generation Industrial use D Commercial/Institutional D Space heating D Other (specify): | |||
COMBUSTION EQUIPMENT CATEGORY* | |||
COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulverized coal wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (specify): | |||
: 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify): | |||
oil1-4 (distillate) | |||
D Coke oven gas OBagasse D Fuel oil 5-6 (residual) | |||
D Liquid propane gas (LPG) OBark OGasoline D Natural gas D Bituminous coal OKerosene ocoke OLignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Des ig n Rate (mmbtu/hr.) | |||
X 1,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.) | |||
= Heat C onte nt (btu/fuel unit) 137,000,000.000000 0.89781 MO 780-1436 (12*09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FAC ILI TY NAME FI P S COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E M I SS I ON UN I T NO. PLAN T NO. Y E AR OF DATA 0026 2010 B-02 I E M I SS I ON UNIT D E SCRIPTION EMERGENCY DIESEL GENERATOR A 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E CLASSIF I CAT I ON COD E (SCC) SCC D E SCR I P TI ON 1 20200402 Dual Fuel (Oil/Gas) | |||
DO TH E EM I SS I O N S F ROM TH I S E M I SSION UN I T F L OW THROUGH A STACK OR V ENT? (8]Yes DN a IF Y E S, COMP LE T E FORM 2.0S S T ACKN E NT INFORMAT I ON AR E TH E E MISS I ONS FROM TH I S UN I T F UG I TIV E? D Yes [8]No I F F UG I T I V E , WHAT PERC E NTAG E? 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPU T UNITS DEC-F EB (%) For coal or fuel oil , list details below 30.00 749.06 1000 MAR-MAY(%) Heat Content (B TU/Fuel Unit) HORSEPOWER-HOURS 55.00 137 , 000 , 000.00 H OU R S/DAY DAYS/WEEK W EE KS/YEAR TOTAL HOURS/Y E AR JU N-AUG (%) ASH % (I NC L UD E IN EF) 9.00 0.00 24.00 7.00 52 8,736.00 S EPT-NOV(%) SU L FUR% (I N C L UD E IN E F) 6.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL x Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 =Actual Emissions (tons) I n structions: | |||
Choose fro m the L bs./unit of th r oughput If EF includes cont r o l Com b ination of all I f controlled, in dude List Othe r Worksheets or Source of E mission mark"C", capture and F orm 2.0C Control AP-42/0ther Reference Facto r list otherwise "U" destruction Device Listing at lower r ight efficiencies PM10 FIL | |||
* 4F 0.7000 No Control 0.00 0.26 SOURCE OF EMISSION FACTOR LIST SOx 4 F 8.0900 No Control 0.00 3.03 1. CEM In c lu de do c u men tat i o n 2. Stack Test I nc l ude d ocu m e n ta ti o n NOx 4F 24.0000 No Control 0.00 8.99 3. Mass Balance In cl u de d o c u m en t a t ion 4. AP-42 I ncl u de r efe r e n ce voc 4F 0.7100 No Control 0.00 0.27 4F. FIRE or webFIRE 5. Oth e r In c l u d e d oc u me nt a ti o n co 4F 5.5000 No Control 0.00 2.06 EC. Engr Ca l c In c lud e do c u me nt atio n LS. Landfill Spdsht In cl u de d ocu m e nt ation LEAD TK. TANKS Program S up pl y TANK S ou tpu t 2.3. VOC Mass Bal C om pl e t e F o nm 2.3 HAPs 2.4. Liquid Load i n g C o mpl e t e F o nm 2.4 2.7. Hau l Road C o mpl e t e F o nm 2.7 PM2.5 FIL | |||
* 2.8. Storage Pile Co mplete F onm 2.8 2.T. HAP Worksheet C o mpl e t e F o nm 2.T NH3 2.9. Stack Test/GEM C o mplet e F o nm 2.9 2.0L. Landfill Compl e t e F o nm 2.0 L PM CON* " I f PM CO N is r eported, PM10 a n d P M25 entries above are required and should r ep r esent only the filte r able PM10 an d filterable PM 25. MO 780-1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) B-02 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL EMERGENCY DIESEL GENERATOR A 09/04/1984 8600 HP COLT INDUSTRIES MODEL PC 2.5 2. OPPOSED 3. FRONT 4. DRY/WET B OTIOM OTHER (SPECIFY) | |||
Sum of total maximum hourly design rates COMBUSTION EQUIPMENT USE (CHECK ONE) Y EAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 58.000000 58.0000 D Electric power generation use D Commercial/Institutional D Space heating D Other (specify): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulverized coal wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (specify): | |||
: 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify): | |||
oil1-4 (distillate) | |||
D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual) | |||
D Liquid propane gas (LPG) 0Bark OGasoline D Natural gas D Bituminous coal OKerosene ocoke D Lignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Design Rate (mmbtu/hr.) | |||
X 1 ,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.) Heat Content (btu/fuel unit) 137,000,000.000000 0.42336 MO 780-1436 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EMISS I ON UNIT NO. PLANT NO. Y E AR OF DATA 0026 2010 B-03 I EM I SSION UNIT DESCRIPT I ON EMERGENCY DIESEL GENERATOR B 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E CLASSIFICATION CODE (SCC) SCC D E SCRIPTION 1 20200402 Dual Fue l (Oil/Gas) | |||
DO THE EM I SSIONS FROM TH I S E MISSION UNIT FLOW THROUGH A STACK OR VEN T? (8]Yes O No I F YES , COMP L E T E FORM 2.0S STACKN E NT I N F ORMAT I ON ARE TH E EM I SSIONS FROM T H I S U NI T F UG ITI VE? D Yes [8J No IF FUG I TIV E , WHAT PERC E NTAGE? 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPUT UNITS D E C-FEB(%) For coal or fue l o i l, list details below 19.00 608.02 1000 MAR-MAY(%) | |||
Heat Content (BTU/Fuel Unit) HORSEPOWER-HOURS 60.00 137 , 000 , 000.00 HOURS/DAY DAYS/W EE K WEEKS/YEAR TOTAL HOURS/YEAR JUN*AUG(%) | |||
ASH % (INCLUDE IN E F) 10.00 0.00 24.00 7.00 52 8 , 736.00 SEPT-NOV(%) SU L FUR% (I NC L UDE IN EF) 11.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONSNR) X STATUS (%FORMAT) | |||
+ 2000 = Actual Emissions (tons) I n s t ructions: | |||
Choose from the Lbs J unit of throughput I f EF includes control Com b ination of all If controlled, include List Other Worksheets or Source of E mission mark*c", capture and Form 2.0C Control AP-42/0ther Reference Fac t or list otherwise "U" destruction Device Listing a t lower right efficiencies PM10 FIL | |||
* 4F 0.7000 No Control 0.00 0.21 SOURCE OF EMISSION FACTOR LIST SOx 4F 8.0900 No Control 0.00 2.46 1. CEM I n c lud e docu m e ntati o n 2. Sta ck Test In c l ude doc um entatio n NOx 4 F 24.0000 No Control 0.00 7.30 3. M ass Ba l an c e In clude documenta t io n 4. AP-4 2 I nclude r eference voc 4F 0.7100 No Control 0.00 0.22 4F. FIRE or webFIRE 5. Oth e r In c l ude docume n tation co 4F 5.5000 No Contro l 0.00 1.67 EC. Eng r Calc I n c lu de docume nt ation LS. Landfill Spdsht I n c lud e documen t ation LEAD TK. TANKS Program Suppl y TANKS o utpu t 2.3. VOC Mass Bal Compl e t e F o rm 2.3 HAPs 2.4. Liquid Loading C o mp le t e F o rm 2.4 2.7. Haul Road Comp lete F orm 2.7 PM2.5 FIL | |||
* 2.8. Storage P i le C o mp l e te F orm 2.8 2.T. HAP Wo rk sheet Comp lete Fo rm 2.T NH3 2.9. S t ack Tes t/CEM C om pl ete F orm 2.9 2.0L. Landfi ll C o mp lete F orm 2.0L PM CON* | |||
* If PM CON is reported, PM10 and PM25 entries above are required and should r ep r esen t only the filterable PM10 and fil t erable P M25. MO 78G-1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FAC I LITY NAME FIPS COUNTY NO. PLAN T NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFIC A TION CODE (SCC) B-03 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL EMERGENCY DIESEL GENERATOR B 09/04/1984 8600 HP COLT INDUSTRIES MODEL PC 2.5 2. OPPOSED 3. FRONT 4. DRY/WET BOTTOM OTHER (SPECIFY) Sum o f tota l max im um hou r ly des i gn ra t es COMBUSTION EQUIPMENT USE (CHECK ONE) YEAR OF DATA 2010 SEG. N O. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 58.000000 58.0000 D Electr i c power generation use D Commercial | |||
/Institutional D Space heating D Other (specify): COMBUSTION EQUIPMENT CATEGORY* | |||
COAL USE ONLY (CHECK ONE) D Pu l ver i zed coa l D Pulver i zed coa l dry bottom D Pulverized coa l wet bottom Ocyclone D Flu i d i zed bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fi red D Other (spec i fy): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthrac i te Coal D Other (spec i fy): | |||
oi l 1-4 (distillate) D Coke oven gas OBagasse D Fuel o il 5-6 (res i dual} D Liqu i d propane gas (LPG) OBark OGaso li ne D Nat u ra l gas D Bitum i nous coal D Kerosene oco k e OL i gn i te D Subbituminous coa l owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maxim u m D esign R ate (mmb tu/hr.) X 1,000,000 (btu/mm b tu) (BTU/FUEL UNIT) (FUEL UNIT/HR.) | |||
= Heat Content (btu/fuel u n i t) 137 , 000 , 000.000000 0.42336 MO 780.1436 (1 2-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EMISSION UNIT NO. PLANT NO. YEAR OF DATA 0026 2010 B-04 I EMISSION UNIT DESCRIPTION SECURITY EMERGENCY GENERATOR | |||
: 2. EMISSION PROCESS DETAIL SEG. NO. I SOURCE ClASSIFICATION CODE (SCC) SCC DESCRIPTION 1 20200402 Dual Fuel (Oil/Gas) | |||
DO THE EMISSIONS FROM THI S EMISSION UNIT FLOW THROUGH A STACK OR VENT? (8J Yes DN a IF YES, COMPLETE FORM 2.0S STACKNENT INFORMATION ARE THE EMISSIONS FROM THIS UNIT FUGITIVE? | |||
D Yes [8J No IF FUGITIVE, WHAT PERCENTAGE? | |||
: 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUAL THROUGHPUT UNITS DEC-FEB (%) For coal or fuel oil , list details below 7.00 18.03 1000 MAR-MAY(%) | |||
Heat Content (BTU/Fue l Unit) HORSEPOWER-HOURS 1.00 137,000,000.00 HOURS/DAY DAYS/WEEK WEEKS/YEAR TOTAL HOURS/YEAR JUN-AUG (%) ASH% (INCLUDE IN EF) 87.00 0.00 24.00 7.00 52 8,736.00 SEPT-NOV(%) | |||
SULFUR % (INCLUDE IN EF) 5.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 =Actual Emissions (tons) Instructions: | |||
Choose from the Lbs./unit of throughput If EF includes control Combination of all If controlled, include List Other Worksheets or Source of Em ission mark"C", capture and Form 2.0C Control AP-42/0ther Reference Factor list otherwise "U" destruction Device List ing at lower right efficiencies PM10 FIL | |||
* 4F 0.7000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 8.0900 No Control 0.00 0.07 1. CEM Include documentation | |||
: 2. Stack Test Include documentation NOx 4F 24.0000 No Control 0.00 0.22 3. Mass Balance Include documentation | |||
: 4. AP-42 Include reference voc 4F 0.7100 No Control 0.0 0 0.01 4F. FIRE or webFIRE 5. Other Include documentation co 4F 5.5000 No Control 0.00 0.05 EC. Engr Calc Include documentation LS. Landfill Spdsht Include documentation LEAD TK. TANKS Program Supply TANKS output 2.3. VOC Mass Bal Complete Fonn 2.3 HAPs 2.4. Liquid Loading Complete Fonn 2.4 2.7. Haul Road Complete F onn 2.7 PM2.5 FIL | |||
* 2.8. Storage Pile Complete F onn 2.8 2.T. HAP Worksheet Complete F onn 2.T NH3 2.9. Stack Test/GEM Complete Fonn 2.9 2.0L. Landfill Complete Fonn 2.0L PM CON* | |||
* If PM CON is reported, PM10 and PM25 entries above are required and should represent only the filterable PM1 0 and filterable PM25. MD 780-1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FAC ILI TY NAME F I PS COU N TY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT E M I SS I ON UN I T NO. SOU R C E CLASS I FICA T ION COD E (SCC) B-04 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANG E NTIAL SECURITY EMERGENCY GENERATOR 09/04/1984 644 HP GENERAL ALLISON DETROIT MFG MODEL V71 2. OPPOSED 3. FRONT 4. DRY/WET BOTTOM OTH E R (SPEC I FY) Sum of tota l maximum hourly des i gn rates COMBUSTION EQUIPMENT USE (CHECK ONE) Y E AR OF DATA 2010 S E G. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 1.700000 1.7000 D Electr i c power generat i on Industrial use D Commerc i a l/Institutional D Space heat i ng D Othe r (specify): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulver i zed coal D Pulver i zed coal dry bottom D Pulverized coa l wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (spec i fy): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (spec i fy): | |||
oil1-4 (distillate) D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual) D Liquid propane gas (LPG) 0Bark OGasoline D Natura l gas D B i tuminous coal D Kerosene ocoke OLignite D Subbituminous coa l owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Max imum D esig n Rat e (mm b tu/h r.) X 1 ,000,0 0 0 (bt u/m m bt u) (BTU/FUEL UNIT) (FUEL UNIT/HR.) | |||
= Heat Co n te n t (btu/fue l unit) 137,000 , 000.000000 0.01241 MO 78()..1436 (12*09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FAC ILI TY NAME FI PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E MISSION UNIT NO. PLAN T NO. Y E AR OF D ATA 0026 2010 B-05 I E MISSION UN IT D E SCR I PTION TSC EMERGENCY GENERATOR | |||
: 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E ClASSI FI CA T ION COD E (SCC) SCC D E SC RI PTION 1 20200402 Dual Fuel (Oil/Gas) | |||
DO TH E E MISSIONS FROM T H I S EM I SSION UNIT F L OW THROUGH A STACK OR V E NT? O No IF Y E S, COM PL E T E FORM 2.0S STACKN E NT IN FORMATION ARE T HE EM I SSIONS FROM TH I S UNIT F UGIT I V E? D Yes IF FUG I TIV E , WHAT P E RC E NTAG E? 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUA L TH ROUG HP UT UNI T S DEC-F EB (%) For coal or fuel oil , l i st details below 34.00 4.83 1000 MAR-MAY(%) | |||
Heat Content (B T U/F uel Unit) HORSEPOWER-HOURS 26.00 137 , 000 , 000.00 H OURS/DAY D AYS/W E EK WEEKS/YEAR TOTAL HOURS/Y E AR JUN-AUG (%) ASH % (I NC L UD E I N E F) 21.00 0.00 24.00 7.00 52 8 , 736.00 S E PT-N OV(%) SU L FUR% (I NC L UDE IN E F) 19.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISS I ON OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONSIYR) | |||
X STATUS (%FORMAT) | |||
+ 2000 =Actual Emissions (tons) I n struc t io n s: Choose from the L bs./unit of th r oughput If E F includes control C ombination of all I f controlled, include List Othe r Worksheets o r Source of E mission ma r k"C", capture and F onn 2.0C Control A P-42/0ther Reference Factor list otherwise destruction Device Listing at lower right efficiencies PM10 FIL | |||
* 4F 2.2000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 2.0500 No Control 0.00 0.00 1. CEM Includ e d o cumen ta t io n 2. S t ack Test I ncl u de docu m e n ta t io n NOx 4F 31.0000 No Control 0.00 0.07 3. Mass Balance I nc l ude documentation | |||
: 4. AP-42 In clude refe re nce voc 4F 2.4700 No Control 0.00 0.01 4F. FIRE or webFIRE 5. Ot h er I n c l ud e doc u me nt ation co 4F 6.6800 No Control 0.00 0.02 EC. Engr Calc I n c lu de docu m e nt at i o n LS. Landfill Spdsht I n c lu de doc um e nt at i o n LEAD TK. TANKS Program S u pp ly TA N K S o utput 2.3. VOC Ma s s Bal C om p lete F orm 2.3 HAPs 2.4. Liqu i d Load i ng C o mpl e t e F orm 2.4 2.7. Hau l Road C om pl e t e Fo rm 2.7 PM2.5 FIL | |||
* 2.8. Storage Pile Compl e t e F o rm 2.8 2.T. HAP Worksheet C o mpl e t e F o rm 2.T NH3 2.9. Stack TestJCEM Comp le t e F orm 2.9 2.0L. Landfill C o mp lete Form 2.0 L PM CON* "If P M CON is r eported, P M10 and P M25 entries above are required and sho u ld represent only the filterable PM1 0 an d filterable PM 2 5. MO 780-1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET F AC ILI TY NAM E FIP S COU N TY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMI S SI ON UN IT NO. SOURC E CLASS IFI CA TI ON CO DE (SCC) B-05 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANG EN T I AL TSC EMERGENCY DIESEL GEN 09/04/1984 355 HP CUMMINS MOD NT-835GS 2. OP P OS E D 3. F RONT 4. DRY/W ET BO TT OM OTH E R (S PE C IF Y) Y E A R O F D A T A 2010 S E G. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 0.800000 Sum of total maximum hourly design rates 0.8000 COMBUSTION EQUIPMENT USE (CHECK ONE) D Electric power generation Industr i al use D Commercial/Institut i onal D Space heating D Other (spec i fy): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulver i zed coal dry bottom D Pulverized coal wet bottom Ocyclone 0 Fluid i zed bed 0 Spreader stoker 0 Overfeed stoker 0 Underfeed stoker 0Hand fired 0 O t her (spec i fy): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify): | |||
oil1-4 (distillate) D Coke oven gas D Bagasse D Fuel oil 5-6 (residual) | |||
D Liquid propane gas (LPG) 0Bark OGasoline D Natu r al gas D Bituminous coal OKerosene ocoke OLignite D Subbitum i nous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Ma xi m um D e sig n R a te (mmbtu/hr.) X 1 ,000, 0 00 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.) | |||
= H eat C o n te n t (b t u/fue l unit) 137 , 000,000.000000 0.00584 MO 78()..1 4 36 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACI LI TY NAM E FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E MISSION UNIT NO. PLANT NO. Y E AR O F DATA 0026 2010 B-06 I EMISS I ON UN I T DESCR I PTION EOF EMERGENCY GENERATOR | |||
: 2. EMISSION PROCESS DETAIL S E G. NO. t SOURC E CLASSIFICA T ION CODE (SCC) SCC D E SCRIPTION 1 20200402 Dual Fuel (Oil/Gas) DO T H E E MISS I ONS FROM TH I S EM I SSION UNIT F L OW THROUGH A STACK OR V E NT? [8)Yes D Na I F Y E S, COM PLE T E FORM 2.0S S T ACKN E NT INFORMAT I ON ARE THE E M I SS I ONS F ROM THIS UN I T FUG I TIVE? D Yes [8J No I F FUGI TI V E , WHAT P ERCENTAG E? 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPUT UNITS D E C-F EB (%) For coal or fuel oil , list deta i ls below 33.00 8.08 1000 MAR-MAY(%) | |||
Heat Content (BTU/Fuel Unit) HORSEPOWER-HOURS 29.00 137,000 , 000.00 HOURS/DAY DAYS/WEEK W EE KS/YEAR T OTAL HOURS/Y E AR JUN-AUG (%) ASH% (INC L UDE I N EF) 22.00 0.00 24.00 7.00 52 8 , 736.00 SEPT-NOV(%) | |||
SU LF UR % (I NC L UDE I N E F) 16.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 =Actual Emissions (tons) I ns tru ct i o n s: Choose from the L bs./unit of throughput I f EF includes cont r ol Combination of all I f controlled, indude List Othe r Worksheets or Source of Emission mark"C" , cap t ure and Form 2.0C Control AP-42/0the r Refe r ence Factor list otherwise "U" destruction Device Listing at lowe r right efficiencies PM10 FIL | |||
* 4F 2.2000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 2.0500 No Control 0.00 0.01 1. CEM In clude doc um e nt a ti o n 2. Stac k Te s t In c l ude docume n ta ti o n NOx 4F 31.0000 No Control 0.00 0.13 3. M as s Balan c e In cl ud e do c u m enta t ion 4. AP-42 I ncl u de r eference voc 4F 2.4700 No Control 0.00 0.01 4F. FIRE or web FIRE 5. Other In c lu de d oc u me n ta ti o n co 4F 6.6800 No Control 0.00 0.03 EC. Engr Calc Inclu de docume nt a t ion LS. Landfill Spdsht In cl u de d ocu m entatio n LEAD TK. TANKS Program S u pp ly TA N KS o utp u t 2.3. V OC Mas s Bal Co mpl e t e F orm 2.3 HAPs 2.4. Liqu i d Load i ng C o mpl et e F orm 2.4 2.7. Hau l Road Com pl e t e F orm 2.7 PM2.5 FIL | |||
* 2.8. Storage P i le C o mple te F o rm 2.8 2.T. HAP Worksheet C om pl e te F orm 2.T NH3 2.9. Stack Tes t/GEM Co mp le t e F orm 2.9 2.0L. Landfill C o m p lete F orm 2.0 L PM CON* 'I f P M CO N is reported, P M10 and P M25 entries above are requi r ed and should represent only the filterable PM10 and filterable PM25. MO 780-1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION COD E (SCC) B-06 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL EOF EMERGENCY GENERATOR 09/04/1984 565 HP CUMMINS MODEL KTA-1150-GS-1 | |||
: 2. OPPOSED 3. FRONT 4. DRY/WET B OTTOM OTHER (SPEC IF Y) Sum of total maximum hourly design rates COMBUSTION EQUIPMENT USE (CHECK ONE) YEAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 1.200000 1.2000 0 Electric power generation use O Commercial/Institutional O Space heating O Other (specify): | |||
COMBUSTION EQUIPMENT CATEGORY -COAL USE ONLY (CHECK ONE) 0 Pulverized coal O Pulver i zed coal dry bottom O Pulverized coal wet bottom Ocyclone D Fluidized bed 0 Spreader stoker 0 Overfeed stoker 0 Underfeed stoker 0Hand fired D Other (specify): | |||
: 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol 0 Blast oven gas 0 Anthracite Coal O Other (specify): | |||
oil1-4 (distillate) | |||
O Coke oven gas 0Bagasse 0 Fuel oil 5-6 (residual) 0 Liquid propane gas (LPG) 0Bark OGasoline O Natural gas O Bituminous coal D Kerosene ocoke D Lignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Desig n Rate (mmb tu/h r.) X 1 ,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.) | |||
= Heat Content (btu/fuel unit) 137,000,000.000000 0.00876 MD 780-14 36 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME F IP S COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E MISSION UNIT NO. PLANT NO. YEAR OF DATA 0026 2010 B-07 I EMISSION UN I T DESCRIPTION FIRE PROTECTION DIESEL GENERATORS (2) 2. EMISSION PROCESS DETAIL SEG. NO. I SOURC E CLASSI FI CA T ION CODE (SCC) SCC D E SCRI PTI ON 1 20200402 Dual Fuel (Oil/Gas) | |||
DO T H E E MISS I ONS FROM TH I S E M I SSION UNIT F LOW THROUGH A STACK OR V E NT? [Rj Yes D Na IF Y E S, COMP LE TE FORM 2.0S S T ACKN E N T IN F ORMAT I ON AR E T H E EM I SS I ONS F ROM THIS UN IT F UG I TIVE? D Yes [Rj No IF FUG I T I V E , WHAT P E RCEN T AG E? 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS AN N UA L THROUGH P UT U NI TS D E C-F E B (%) For coal or fuel oil , list details below 20.00 7.65 1000 MAR-MAY(%) | |||
Heat Content (B TU/Fuel Unit) HORSEPOWER-HOURS 27.00 137 , 000 , 000.00 HOURS/D AY DAYS/W EE K W EE KS/YEAR TO T A L HOURS/Y E AR JUN-AUG (%) ASH% (INCLUDE IN EF) 36.00 0.00 24.00 7.00 52 8,736.00 S EP T-NOV(%) SU L FUR% (I NCLUD E IN EF) 17.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 =Actual Emissions (tons) I nst ru ct i o n s: Choose f r om the L bs./unit of throughput I f E F includes control Combination of all I f controlled, include List Other Worksheets o r Source of E mission mark"C", capture and Form 2.0C Control AP-42/0ther Refe r ence Facto r l ist otherwise "U" destruction Device Listing at lower right efficiencies PM10 FIL | |||
* 4F 2.2000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 2.0500 No Control 0.00 0.01 1. CEM In cl ud e d ocu mentat io n 2. Stack Test In clude doc u me n tati o n NOx 4F 31.0000 No Control 0.00 0.12 3. Mass Balance I nclude docume ntatio n 4. AP-42 Include r efe r e n ce voc 4F 2.4700 No Contro l 0.00 0.01 4F. F I RE or web F I RE 5. Other Incl ud e docu m e nt atio n co 4F 6.6800 No Control 0.00 0.03 EC. E n gr Ca l c In clu d e d o cu m e n ta t io n LS. Landfill Spdsht In cl u de docu m e nt a t io n LEAD TK. TANKS Program S up p ly TANK S o u tpu t 2.3. VOC Mass Bal Com p le t e F orm 2.3 HAPs 2.4. Liquid Load i ng C o mp lete F orm 2.4 2.7. Haul Road C o mpl e t e F orm 2.7 PM2.5 FIL | |||
* 2.8. Storage P i le C om plete F o rm 2.8 2.T. HAP Worksheet C o mpl e t e F o rm 2.T NH3 2.9. Stack Test/GEM Co mpl e te Fo rm 2.9 2.0L. Landfi l l C om pl e t e F o rm 2.0 L PM CON* 'I f P M C ON is reported, P M10 and P M25 entries above a r e r e qu ire d and should r ep r esent on l y the filterable P M1 0 and filterable P M25. MO 780-1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) B-07 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. T ANG ENTIAL FIRE PROTECTION DIESEL GEN 09/04/1984 (2) 255 HP CUMMINS NT-855-F1 | |||
: 2. OPPOS ED 3. FRONT 4. DRY/WET BOTTOM OTH ER (S PECIFY) Sum of total maximum hourly design rates COMBUSTION EQUIPMENT USE (CHECK ONE) YEAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 1.200000 1.2000 D Electric power generation Industrial use D Commercial/Institutional D Space heating D Other (specify): | |||
COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulverized coal wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker D Hand fired D Other (specify): | |||
: 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify): | |||
oil1-4 (distillate) | |||
D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual) | |||
D Liquid propane gas (LPG) 0Bark OGasoline D Natural gas D Bituminous coal OKerosene ocoke D Lignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Design Rate (mmbtu/hr.) | |||
X 1 ,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.) | |||
= Heat Content (btu/fuel unit) 137,000,000.000000 0.00876 MO 780-1436 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAM E FI PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EM I SS I O N UN I T N O. P LAN T NO. YEAR OF DATA 0026 2010 B-10 I E M I SS I ON UNIT D E SCR I PT I O N PORTABLE DIESEL GENERATOR | |||
: 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E CLASS I FICATION CODE (SCC) SCC D E SCR I PT I ON 1 20200402 Dual Fue l (Oil/Gas) DO TH E EMISSIO N S FRO M TH I S E MISSION UNIT FL OW THROUGH A S T ACK OR V E NT? D Yes [8]No I F Y E S, COMP L ET E FORM 2.0S STACKN E NT INFORMATION ARE T H E E M I SSIONS FROM T H I S U N I T F UGITIV E? (8]Yes O No I F FUGITIV E , WHAT P E RC E N T AG E? 100.00 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPU T UN I TS DEC-FEB (%) For coal o r fuel oil, list details below 0.00 0.00 1000 MAR-MAY(%) | |||
Heat Content (B TU/F ue l Unit) HORSEPOWER-HOURS 0.00 137 , 000,000.00 HOURS/DAY DAYS/W E EK W EE KS/YEAR TOTA L HOURS/Y E AR JU N-AUG (%) ASH % (INC L UDE IN EF) 0.00 0.00 24.00 7.00 52 8 , 736.00 S EPT-NOV(%) SULFUR% (INC L UD E IN E F) 0.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL x Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 =Actual Emissions (tons) I n s tru c t ions: Choose f r om the L bs./unit of throughput If EF includes cont r ol Combination of all If controlled, include List Other Worksheets or Source of E mission mark"C", captu r e and Form 2.0C Control AP-42/0the r Refe r ence F ac t or list otherwise "U" destruction Device List i ng at lower right efficie n cies PM10 FIL | |||
* 4F 42.4700 No Control 0.00 0.00 SOURCE OF EMISSION FACTOR LIST SOx 4F 39.7300 No Control 0.00 0.00 1. CEM In cl ud e d o cu m e n ta ti o n 2. Stac k Test In c l ude docu m e nt a t io n NOx 4F 604.1700 No Control 0.00 0.00 3. Mass Ba l ance In c l ude doc um e nt at i o n 4. AP-42 I n c lu de re f er e n ce voc 4F 47.9500 No Control 0.00 0.00 4F. FIRE or webFIRE 5. Other In c l ude d oc um e n ta tion co 4F 130.1500 No Control 0.00 0.00 EC. Engr Calc In c lu de d ocu m e nt ati on LS. Landfill Spdsht I n c l ude docu m e nt ation LEAD TK. TANKS Program Suppl y TAN KS output 2.3. VOC Mass Bal C o mplete Form 2.3 HAPs 2.4. Liqu i d Load i ng C o mplet e Form 2.4 2.7. Haul Road C o mpl e t e F o rm 2.7 PM2.5 FIL | |||
* 2.8. Storage Pile C om plet e Form 2.8 2.T. HAP Worksheet Co mp lete F orm 2.T NH3 2.9. Stac k Test/GEM Comple te F orm 2.9 2.0L. Landfil l C o mplete F o rm 2.0 L PM CON* | |||
* If PM CON is reported, PM1 0 and PM25 entries a bove are r equire d and should represent only the filterable PM10 and filterable P M25. MO 780-1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAM E FI P S COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT E MISS I ON UN I T NO. SOURCE CLASSIF I CA T ION COD E (SCC) B-10 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. T A NGENTIA L KOHLER 180 KW DIESEL GENERATOR 09/04/1995 MODEL# 180ROZJ 2. O P POSED 3. FRONT 4. DRY/WET BOTTOM OTHER (SPECIFY) Sum of total ma x imum hourly des i gn rates COMBUSTION EQUIPMENT USE (CHECK ONE) Y E AR O F DATA 2010 S E G. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 3.905000 3.9050 Electric power generation D Industrial use D Commercial/Institut i onal D Space heating D Other (spec i fy): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulver i zed coal wet bottom Ocyclone D Flu i dized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (specify): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (spec i fy): | |||
oil1-4 (dist i llate) D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual} D Liquid propane gas (LPG) OBark OGasol i ne D Natural gas D Bituminous coal D Kerosene ocoke OL i gnite D Subb i tuminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum D esign Rate (mmb t u/hr.) X 1.000.000 (b tu/m mbt u) (BTU/FUEL UNIT) (FUEL UNIT/HR.) | |||
= H eat Content (btu/fuel u n it) 137 , 000 , 000.000000 0.02850 MO 780.14 3 6 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EMISSION UNIT NO. PLANT NO. YEAR OF DATA 0026 2010 B-12 I EMISSION UNIT DESCRIPTION 4 Permanent Diesel Generators | |||
: 2. EMISSION PROCESS DETAIL SEG. NO. I SOURCE CLASSIFICATION CODE (SCC) SCC DESCRIPTION 1 20200402 Dual Fuel (Oil/Gas) | |||
DO THE EMISSIONS FROM THIS EMISSION UNIT FLOW THROUGH A STACK OR VENT? (8J Yes D Na IF YES, COMPLETE FORM 2.0S STACKNENT INFORMATION ARE THE EMISSIONS FROM THIS UNIT FUGITIVE? | |||
D Yes [8}No IF FUGITIVE, WHAT PERCENTAGE? | |||
: 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUAL THROUGHPUT UNITS DEC-FEB(%) | |||
For coal or fuel oil, list deta ils below 0.00 261.00 1000 MAR-MAY(%) Heat Con lent (BTU/Fuel Un i t) HORSEPOWER-HOURS 0.0 0 HOURS/DAY DAYS/WEEK WEEKS/YEAR TOTAL HOURS/YEAR JUN*AUG (%) ASH % (INCLUDE IN EF) 0.00 0.00 8.00 5.00 52 2 , 080.00 SEPT-NOV (%) SULFUR % (INCLUDE IN EF) 100.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 = Actual Emissions (tons) Instructions | |||
: Choose from the Lbs J unit of throughput If EF i ncludes control Combination of all If controlled, indude List Other Worksheets or Source of Emission mark"C", capture and Form 2.0C Control AP-42/0ther Reference Factor list otherwise "U" destruction Device Listing at lower right efficiencies PM10 FIL | |||
* 5 -Manufacturer 0.1200 No Control 0.00 0.02 SOURCE OF EMISSION FACTOR LIST Specifications SOx 5 0.0100 No Control 0.00 0.00 1. CEM Include documentation | |||
: 2. Stack Test Include documentation NOx 5 11.0000 No Control 0.00 1.44 3. Mass Balance Include documentation | |||
: 4. AP-42 Include reference voc 5 0.5200 No Control 0.00 0.07 4F. FIRE orwebFIRE | |||
: 5. Other Include documentation co 5 1.1100 No Control 0.00 0.14 EC. Engr Calc Include documentation LS. Landfill Spdsht Include documentation LEAD TK. TANKS Program Supply TANKS output 2.3. VOC Mass Ba l Complete Form 2.3 HAPs 2.4. Liquid Loading Complete Form 2.4 2.7. Haul Road Complete Form 2.7 PM2.5 FIL | |||
* 2.8. Storage P ile Complete Form 2.8 2.T. HAP Worksheet Complete Form 2.T NH3 2.9. Stack TestJCEM Complete Form 2.9 2.0L. Landfill Complete Form 2.0L PM CON* "If PM CON is reported, PM10 and PM25 entries above are required and should represent only the filterable PM1 0 and fillerable PM25. MO 780--1621 (05-10) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACI LI TY NAM E F I PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E M I SSION UNIT NO. PLA N T NO. YEAR O F DATA 0026 2010 B-13 I EMISSION UN I T DESCR I PTION 5 Temporary Diesel Generators | |||
: 2. EMISSION PROCESS DETAIL S E G. NO. I SOURCE CLASSI FI CATION CODE (SCC) SCC D E SCR I PTION 1 20200402 Dual Fue l (Oil/Gas) DO THE E M I SS I ONS F ROM THIS E MISS I ON UNIT F L OW THROUGH A S T ACK OR V E NT? (8]Yes D No IF Y E S , COMP LE T E F ORM 2.0S STACKNENT I N F ORMATION ARE TH E E M I SS I ONS FROM THIS UN I T FUG IT IV E? D Yes [8J No I F FUGIT I VE, WHAT P E RC E NTAG E? 3. OPERATING RATE/SCHEDULE | |||
: 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPUT UN I TS DE C-F EB (%) For coal or fuel oil , list details below 50.00 22.99 1000 MAR-MAY(%) | |||
Heat Con lent (BTU/Fuel Unit) HORSEPOWER-HOURS 0.00 HOURS/D AY DAYS/W EE K W EE KS/YEAR TOTAL HOURS/YEAR JUN-AUG (%) ASH% (I NC L UDE IN EF) 50.00 0.00 8.00 5.00 52 2 , 080.00 SEPT-NOV(%) | |||
SU L FUR % (INC L UD E I N E F) 0.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF) | |||
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR) | |||
X STATUS (%FORMAT) | |||
+ 2000 = Actual Emissions (tons) I n s t ruc ti ons: Choose from the Lbs./unit of throughput If EF includes cont r ol Combination of all If controlled , include List Other Worksheets or Source of E mission ma r k"C" , capture and Form 2.0C Control AP-42/0ther Reference Factor list otherwise "U" destruction Device Listing at lower right efficiencies PM10 FIL | |||
* 5 -Manufacturer' s 0.1200 No Control 0.00 0.00 SOURCE OF EMISSION FACTOR LIST S p e ci ficat i on s SOx 5 0.0100 No Contro l 0.00 0.00 1.CEM I n cl u de documen tat io n 2. Stac k Test In clude docume n ta ti o n NOx 5 11.0000 No Control 0.00 0.13 3. M ass Balance In cl ud e docume n ta t io n 4. AP-4 2 In c l ude r efe r e n ce voc 5 0.5200 No Control 0.00 0.01 4F. FIRE or we b FIRE 5. Other I n c lu d e docume n tation co 5 1.1100 No Control 0.00 0.01 EC. Eng r Calc I n cl u de documentatio n LS. Land fi ll Spdsh t In c lu d e documen t ation LEAD TK. TANKS Program S u ppl y TANKS ou tpu t 2.3. VOC Mass Ba l Compl e t e F o rm 2.3 HAPs 2.4. Liquid Loading C omp l e t e Fo rm 2.4 2.7. Haul Road C o mp lete F o rm 2.7 PM2.5 FIL | |||
* 2.8. Storage P i le C o mpl e te F orm 2.8 2.T. HAP Worksheet C om p l e te F o rm 2.T NH3 2.9. Stack TesUCEM C o mpl e t e F o rm 2.9 2.0L. Landfill Com p le t e F orm 2.0 L PM CON* | |||
* I f PM CON is r eported, P M10 and P M25 entries above a r e r e q ui r ed and should rep r esent only the filterable PM1 0 and filterable P M25. MO 780-1621 (05-1 0) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0S STACKNENT INFORMATION FACILITY NAME F I PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT EM I SS I ON UNIT NO. SOURCE CLASSIFICATION COD E (SCC) SEG. NO. B-01 10200501 1 STACK/VENT NO. STACK/VENT DESCRIPTION S-1 PLANT NO. YEAR O F DATA 0026 2010 FOR A NON-C I RCULAR STACK: 0 Vent DIAMET E R= (1.128A)'1/2 (A=CROSS SECTIONAL AREA IN sa FEET) %OF EMISSIONS RE L EASED 100.00 STACK/VENT O P ERATING STATUS (CHECK ONE) | |||
O lnactive O oismantled HE I GHT (FT.) DIAM E T ER (FT.) TEMPERATURE (F) V EL OCITY (FT./M I N.) F L OW RAT E (CU F T./MIN.) LI ST OTH E R P O I NTS SHARING T HIS STACK/VENT 150.00 5.000 655.00 2 , 254.00 44 , 179.00 EM I SSION UNIT NO. SOURCE CLASSIF I CAT I ON COD E (SCC) S E G. NO. FOR A NON-C I RCULAR STACK: B-02 20200402 1 0 Vent DIAM E T E R= (1.128A)'1/2 (A=CROSS S E CTIONAL AREA I N Sa F EET) STACK/VENT NO. STACK/V E NT DESCR I PT I ON % OF EMISS I ONS R E LEASED S-2 100.00 STACK/VENT OPERATING STATUS (CH E CK ONE) | |||
Ol nactive O oismantled H EI GHT (FT.) DIAMETER (FT.) TEMPERATURE (F) V E LOCITY (F T./MIN.) F L OW RAT E (CU FT./MIN.) | |||
LIST OTH E R PO I NTS SHAR I NG TH I S STACK/VENT 98.00 4.000 760.00 7 , 252.00 69,623.00 E M I SS I O N UNI T N O. SOURCE CLASSIF I CA T ION CO DE (SCC) S E G. NO. | |||
FOR A N ON-C I RCULAR S T ACK: B-03 20200402 1 0 Vent D I AME TE R= (1.128A)'1/2 (A=CROSS SECT I ONAL AREA IN Sa FEET) STACK/VENT NO. STACK/VENT DESCRIPTION | |||
% OF E MISSIONS RE L EAS E D S-3 100.00 STACK/VENT OPERAT I NG S T A T US (CHECK ONE) | |||
O lnactive O oismantled HEIGHT (FT.) DIAM E T E R (FT.) TEMPERATURE (F) V EL OCITY (FT./MIN.) | |||
FLOW RATE (CU FT./MIN.) | |||
LIST OTHER POIN T S SHARING THIS STACK/VENT 98.00 4.000 760.00 7 , 252.00 69 , 623.00 EM I SS I ON UN IT N O. SOURCE CLASS I FICA T ION CO DE (SCC) S E G. N O. | |||
FOR A NO N-C I RCU LA R STACK: B-04 20200402 1 0 Vent D I AMETER= (1.128A)'1/2 (A=CROSS SEC TI O N A L AREA IN Sa FEET) STACK/VENT NO. STACK/VENT DESCR I PTION % OF EM I SSIONS RELEAS E D S-4 100.00 STACK/VENT OP E RATING STATUS (CHECK ONE) | |||
O lnactive O oismantled HEIGHT (FT.) DIAM E T E R (FT.) TEMPERATURE (F) V EL OCITY (FT./MIN.) | |||
F L OW RATE (CU FT./MIN.) | |||
LIST OTHER PO I NTS S H AR I NG TH I S STACK/VENT 19.00 2.000 780.00 2 , 864.00 6 , 300.00 MO 780-1435 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0S STACKNENT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. B-05 20200402 1 STACKNENT NO. STACKNENT DESCRIPTION S-5 PLANT NO. YEAR OF DATA 0026 2010 [8] Stack FOR A NON-CIRCULAR STACK: D Vent DIAMETER= | |||
(1.128A)'1/2 (A=CROSS SECTIONAL AREA IN Sa FEET) % OF EMISSIONS RELEASED 100.00 STACKNENT OPERATING STATUS (CHECK ONE) [8]Ac tive Dlnacti ve D Dismantled HEIGHT (FT.) DIAMETER (FT.) TEMP ERA TURE (F) VELOCITY (FT./M IN.) FLOW RATE (CU FT./M IN.) LIST OTHER POINTS SHARING THIS STACKNENT 18.00 2.000 915.00 772.00 1,960.00 EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. [8] Stack FOR A NON-CIRCULAR STACK: B-06 20200402 1 D Vent DIAMETER= | |||
(1.128A)'1/2 (A=CROSS SECTIONAL AREA IN sa FEET) STACKNENT NO. STACKNENT DESCRIPTION | |||
% OF EMISSIONS RELEASED S-6 100.00 STACKNENT OPERATING STATUS (CHECK ONE) [8]Ac live Dlna ctive Oo ismantled HEIGHT (FT.) DIAMETER (FT.) TEMPERATURE (F) V ELOCITY (FT./MIN.) FLOW RATE (CU FT./MIN.) | |||
LIST OTHER POINTS SHARING THIS STACKNENT 19.00 2.000 950.00 1,388.00 3,040.00 EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. [8] Stack FOR A NON-CIRCULAR STACK: B-07 20200402 1 D Vent DIAMETER = (1.128A)'1/2 (A=CROSS SECTIONAL AREA IN Sa FEET) STACKNENT NO. STACKNENT DESCRIPTION | |||
% OF EMISSIONS RELEASED S-7 100.00 STACKNENT OPERATING STATUS (CH ECK ONE) [8]Act ive Dln active Ooi smantled HEIGHT (FT.) DIAMETER (FT.) TEMPERATURE (F) VELOCITY (FT./MIN.) | |||
FLOW RATE (CU FT./MIN.) | |||
LIST OTHER POINTS SHARING THIS STACKNENT 18.00 1.000 823.00 1,216.00 955.00 EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. [8] Stack FOR A NON-CIRCULAR STACK: B-12 20200402 1 D Vent DIAMETER= | |||
(1.128A)'1/2 (A=CROSS SECTIONAL AREA IN sa FEET) STACKNENT NO. STACKNENT DESCRIPTION | |||
% OF EMISSIONS RELEASED S-2 100.00 STACKNENT OPERATING STATUS (CH ECK ONE) [8]Acl ive Dlnac tive Ooi smantled HEIGHT (FT.) DIAMETER (FT.) TEMPERATURE (F) VELOCITY (F T./M IN.) FLOW RATE (CU FT./MIN.) | |||
LIST OTHER POINTS SHARING THIS STACKNENT 98.00 4.000 760.00 7 , 252.00 69,623.00 MO 780-1435 (12-09) | |||
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0S STACKNENT INFORMATION F AC ILI TY N A ME FIPS COU N TY N O. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT E M I SS I O N UNIT N O. SOURC E CLASS I FICA TI ON CO DE (SCC) S E G. N O. B-13 20200402 1 STACKN ENT NO. S T ACKN E N T D E SC RIP T I ON S-3 P LANT NO. Y E A R O F D A T A 0026 2010 IRJ Stack FOR A N ON-C I RCU LA R STACK: 0 Vent D I AM ETE R= (1.128A)'1/2 (A=CROSS S E CT I O N A L AREA IN SQ FE E T) %O F E MISS I O N S R ELEA SED 100.00 S T ACKN ENT OP E RAT IN G S T ATUS (CHECK ONE) (8]Active O lnactive 0 D ismantled H EI GHT (FT.) D I AM E T E R (FT.) TE M PE RATUR E (F) V EL OCITY (F T./MIN.) FL OW RAT E (CU FT./M IN.) LI S T O T H E R P O I NTS SHARING THIS STACKN E NT 98.00 4.000 760.00 7 , 252.00 69 , 623.00 MO 780-1 4 35 (12-09) | |||
FACILITY NAME MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 3.0 EMISSIONS FEE CALCULATION FIPS COUNTY NO. PLANT NO. YEAR OF DATA AMEREN MISSOURI 027 0026 2010 CALLAWAY NUCLEAR POWER PLANT 1. Use one row to list the emissions from one emission unit. Sum the emissions in the page total box at the bottom of the column. EMISSION UNIT NO. If more than one page is needed, use the first row of the duplicated page to list the page totals from this page. Express figures in tons per year and round to two decimal places. sec AIR POLLUTANT PM10 FIL SOx NOx voc co LEAD HAPs PM2.5 FIL NH3 PM CON B-01 0.18 1.14 3.65 0.04 0.91 0.00 0.00 0.00 0.00 0.00 10200501 B-02 0.26 3.03 8.99 0.27 2.06 0.00 0.00 0.00 0.00 0.00 20200402 B-03 0.21 2.46 7.30 0.22 1.67 0.00 0.00 0.00 0.00 0.00 20200402 B-04 0.01 0.07 0.22 0.01 0.05 0.00 0.00 0.00 0.00 0.00 20200402 B-05 0.01 0.00 0.07 0.01 0.02 0.00 0.00 0.00 0.00 0.00 20200402 B-06 0.01 0.01 0.13 0.01 0.03 0.00 0.00 0.00 0.00 0.00 20200402 B-07 0.01 0.01 0.12 0.01 0.03 0.00 0.00 0.00 0.00 0.00 20200402 B-10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20200402 B-12 0.02 0.00 1.44 0.07 0.14 0.00 0.00 0.00 0.00 0.00 20200402 B-13 0.00 0.00 0.13 0.01 0.01 0.00 0.00 0.00 0.00 0.00 20200402 PAGE TOTALS 0.70 6.72 22.03 0.62 4.92 0.00 0.00 0.00 0.00 0.00 Note: Fill out the lower portion of this form one time only. 2. ACTUAL EMISSIONS (Use the sum of all page totals for each pollutant for actual emission figures below.) PM10 SOx NOx voc co LEAD HAPs PM2.5 NH3 PM CON Total TOTAL TOTAL 6.72 22.03 0.62 4.92 0.00 0.00 0.00 Included in 0.70 0.00 Total PM10 and PM2.5 \..opy the actual emissions from section 2 to the appropriate box(es) in the Total Plant Emissions section of Form 1.0 General Plant Information. | |||
: 3. CHARGEABLE EMISSIONS (Maximum 4,000 Tons/Yr. cap per pollutant) | |||
NO FEES NO FEES NO FEES PM CON is Total 0.70 6.72 22.03 0.62 FOR CO 0.00 0.00 FORPM2.5 FORNH3 included in PM10 and PM2.5 4. SUM OF CHARGEABLE EMISSIONS SUBJECT TO FEES Round chargeable emissions to the nearest whole ton. The minimum emission 30.00 TonsNr. onnage is one ton, and the maximum is 12,000 tons per year. 15* TOTAL ANNUAL EMISSIONS FEE Multiply the sum of chargeable emissions as calculated in section 4 by $40 and enter $ 1 , 200.00 his amount in section 5. The minimum fee is $40. ANNUAL EMISSIONS FEE REMITTED TO THE CITY OF KANSAS CITY OR ST. LOUIS COUNTY LOCAL AIR AGENCY HECK NUMBER r_HECK DATE rMOUNT REMITIED IN CALENDAR YEAR OF RECORD $0.00 | |||
$ 1 , 200.00 LLUTION CONTROL PROGRAM. F Facilities within local air program jurisdiction only need to include copies of Form 1.0 General Plant Information , 3.0 Emissions Fee Calculation and Form 4.0 Financial Cost Estimate with the emissions fee check. MO 780.1509 (12*09)}} | |||
Revision as of 04:21, 18 March 2019
| ML12271A461 | |
| Person / Time | |
|---|---|
| Site: | Callaway |
| Issue date: | 04/28/2011 |
| From: | Whitworth S C Ameren Services Co |
| To: | Kavanaugh J L Office of Nuclear Reactor Regulation, State of MO, Dept of Natural Resources |
| References | |
| ULNRC-05893 | |
| Download: ML12271A461 (30) | |
Text
Ameren Services :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
April 28, 2011 Mr. James L. Kavanaugh Department of Natural Resources Air Pollution Control Program P.O. Box 176 Jefferson City, MO 65102-0176 Re: 2010 Emission Inventory Questionnaire
Dear Mr. Kavanaugh:
Enclosed are signed copies of EIQ Form 1.0 for seventeen (17) Ameren facilities. Ameren has submitted the EIQs electronically using the MOEIS software.
Emissions fees in the amount of $1,463,816.00 have been deposited in the MDNR account via electronic funds transfer.
Ameren Corporation facilities reported are:
- Callaway Plant
- Fairgrounds Combustion Turbine
- Kirksville Combustion Turbine
- Labadie Plant
- Meramec Plant
- Mexico Combustion Turbine
- Moberly Combustion Turbine
- Moreau Combustion Turbine
- Rush Island Plant
- Sioux Plant
- Peno Creek Combustion Turbine
- Lakeside Works Headquarters
- Columbia Combustion Turbine
- Audrain Combustion Turbine
- Taum Sauk Plant (#0032) (#0584, 0585,0586,0621,0633 did not operate in 2010}
- Howard Bend Combustion Turbine
- Viaduct HAPS emissions will be based on the Toxic Release Inventory (TRI) report. The EIQ reports will be revised by the end of July. Questions concerning the information contained in these reports should be directed to me at 314-554-4908.
Sincerely, , 1 Manager Environmental Services T 314.554.4908 F 314.554.4182 swhitworth@ameren.com Ameren Services As Affi/IMed Agent for Union Electric Company d/b/a Ameren Miuouri & Ameren Energy Generating Company Enclosures
...........................................................................................................
...........................................................................................................
- ***********************************************************************************************************
1901 Chouteau Avenue PO Box 66149 , MC 602 St.lou i s , MO 63166-6149 Ameren.com bee cover letter only: D. F. Cole M. W. Litzinger/0.
K. Wenk M.C. Birk MLM/SCW/KJNDKW AQ 5.2.6 0.-\aitVJkvll\tlmiSaion
/etters\2010 Eml$sion Inventory Questionnaire
.doc) bee cover letter & facility enclosures:
A C Heflin (Callaway)
- 0. L. Lomax (CTGs-except Columbia)
T. E. Lafser/D.
K. Wenk (Rush Island) K.P. Blank/M. J. Tomasovic (Sioux} D. L. Strubberg/M.
J. Tomasovic (Labadie)
R. H. Deberge (Peno Creek; Audrain) B. L. Schuh (Columbia CT) W.A Witt (Osage) AQ 5.2.1 (Callaway)
AQ 5.2.2 (CTGs) AQ 5.2.4 (Labadie)
AQ 5.2. 7 (Rush Island) AQ 5.2.8 (Sioux) AQ 5.2.10 (Taum Sauk, Lakeside WHO) AQ 5.2.20 (Columbia CT) DKW (ALL) 2010 Emission Fee Summary Power Plants
- Callaway $ 1200
- Labadie 441,160
- Maramec 340,896
- Rush Island 328,720
- Sioux 346,920 Combustion Turbines
- Kirksville
$ 40
- Fairgrounds 40
- Columbia 40
- Audrain 1560
- Mexico 40
- Moberly 320
- Moreau 40
- Peno Creek 2720
- Viaduct 40
- Howard Bend 0 Lakeside Works Hdqtrs 40 Taum Sauk Plant 40 TOTAL $1,463,816 MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 1.0 GENERAL PLANT INFORMATION D Request Confidentiality -He Instructions to Initiate the confidentiality request. FACIUTY NAME FIPS COUNTY NO. PlANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT FACILITY STREET ADDRESS COUNTY NAME MISSOURI HWY CC CALLAWAY CITY ZIP CODE ** PHONE NUMBER WITH AREA CODE EXT. FULTON 63166-0000 573-676-8769 FACILITY MAILING ADORESS CITY PO BOX620 PORTLAND YEAR OF DATA 2010 FAX NUMBER WITH AREA CODE STATE IZIPCOO E** MO 65251
- 0000 FACIUTY CONTACT NAME FACILITY CONTACT TITLE FACIUTY CONTACT E.f.IAIL WHERE TO SEND EIQ IN FUTURE (CHECK ONE) ADAM HEFLIN SR VICE PRESIDENT aheflin@ameren.com F a cil ity Ma ilin g Address 0 Pa r ent Company Mai l ing Addreu PRODUCT/PRINCIPAL ACTMTY SIC NAICS NUWIER OF EMPLOYEES ELECTRICITY 4911 221113 510.00 LA"']JUDE LONGITUDE UTM COORDINATES DEGREES 38 -91 ZONE EASTING(M)
NORTHING(M)
ACC(M) HORIZONTAL DATUM (Ched< Ono) 15N 605259.195 4290680.718 15.0 MINU T ES 45 47 0 NAD27 0 WGS84 SECONDS 30.8088 18.7656 PARENT COMPANY NAME PHONE NUMBER WITH AREA CODE EXT. FAX NUMBER AMERENCORP 314-554-4908 MAILING ADDRESS CITY STATE ZIP CODE+* PO BOX 66149 MC-602 SAINT LOUIS MO 63166-0000 CONTACT PERSON NAME CONTACT PERSON TITLE CONTACT PERSON E-MAIL COUNTRY STEVE WHiiWORTH scwhitworth@ameran
.com UNITED STATES PLANT EMISSIONS FROM FORM 3.0 (tONS PER YEAR) II PM10 JSOx NOx (we leo rEAD HAPa IPM25 INH3 0.70 6.72 22.03 0.62 4.92 0.00 0.00 0.00 0.00 The undersigned hereby certifies that they have personally examined and are familiar with the information and statements contained herein and further certifies that they believe this Information and statements to be true, accurate and complete.
The undersigned certifies that knowingly making a false statement or miareprasentlng the facts presented in this document Is a violation of state law. PRINT NAME OF WENt-TITLE 'EJJ 6 (L SIGNATURE I!
WtMffi_ DATE 4.J !'* If CHECK/AUTH
.NO. PRINT NAME OF AUTHORIZED COMPANY REPRESENTATIVE TITLE PAYMENT DATE J!1 ( C H /h'5 L. /-, /"!-£. ,W H*. 1/l'--
SIGHATUR( .J-.. ./_. DATE t:;.Y-27-11 7/Z. .., 9
..
,. OPFICa UU OHLY Missouri Department of Natural Resources I.OGGI!D IN .-/l DATE Pollution Control Program 1659 E. Elm St.
City, Mo 65101 573-751-4817 www.dnr.mo.gov/env/apcp/moels/emlssionsreportlng.htm
' eiq@dnr.mo.gov . MO (12-o&)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 1.0 GENERAL PLANT INFORMATION D Request Confidentiality -see instructions to initiat e the confidentiality request. FACILITY NAME FIPS COUNTY NO. PLANT NO. YEAR OF DATA AMEREN MISSOURI 027 0026 2010 CALLAWAY NUCLEAR POWER PLANT FACILITY STREET ADDRESS COUNTY NAME MISSOURI HWY CC CALLAWAY CITY ZIP CODE+ 4 PHONE NUMBER W ITH AREA CODE EXT. FAX NUMBER WITH AREA CODE FULTON 63166-0000 573-676-8769 FACILITY MAILING ADDRESS CITY STATE ZIP CODE+ 4 PO BOX 620 PORTLAND MO 65251 -0000 FACILITY CONTACT NAME FACILITY CONTACT TITLE FACILITY CONTACT E*MAIL WHERE TO SEND EIQ IN FUTURE (CH ECK ONE) ADAM HEFLIN SR VICE PRESIDENT ahefiin@ameren.com
[8] Facility Mailing Address D Parent Company Mailing Address PRODUCT/PRINCIPAL ACTIVITY SIC NAICS NUMBER OF EMPLOYEES ELECTRICITY 4911 221113 510.00 LATITUDE LONGITUDE UTM COORDINATES DEGREES 38 -91 ZONE EASTING (M) NORTHING(M)
ACC(M) HORIZONTAL DATUM (Check One) 15N 605259.195 4290680.718 15.0 MINUTES 45 47 D NAD27 D WGS84 30.8088 18.7656 (8] NAD83 SECONDS PARENT COMPANY NAME PHONE NUMBER WITH AREA CODE EXT. FAX NUMBER AMEREN CORP 314-554-4908 MAILING ADDRESS CITY STATE ZIP CODE +4 PO BOX 66149 MC-602 SAINT LOUIS MO 63166-0000 CONTACT PERSON NAME CONTACT PERSON TITLE CONTACT PERSON E-MAIL COUNTRY STEVE WHITWORTH scwhitworth@ameren.com UNITED STATES irOTAL PLANT EMISSIONS FROM FORM 3.0 (TONS PER YEAR) PM10 I SOx NOx lvoc leo I LEAD HAPs I PM25 I NH3 0.70 6.72 22.03 0.62 4.92 0.00 0.00 0.00 0.00 The undersigned hereby certifies that they have personally examined and are familiar with the information and statements contained herein and further certifies that they believe this information and statements to be true , accurate and complete.
The undersigned certifies that knowingly making a false statement or misrepresenting the facts presented in this document is a violation of state law. PRINT NAME OF PERSON COMPLETING FORM TITLE PAYMENT AMOUNT SIGNATURE DATE CHECKIAUTH.NO.
PRINT NAME OF AUTHORIZED COMPANY REPRESENTATIVE TITLE PAYMENT DATE SIGNATURE DATE INFORMATION OFFICE USE ONLY Missouri Department of Natural Resources LOGGED IN BY DATE Pollution Control Program 1659 E. Elm St.
City, Mo 65101 f573-751-4817 MO 780-1431 (12-09)
FACILITY NAME MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 1.2
SUMMARY
OF EMISSION UNITS AND RELATED PROCESSES FIPS COUNTY NO. PLANT NO. YEAR OF DATA AMEREN MISSOURI 027 0026 2010 CALLAWAY NUCLEAR POWER PLANT INSTRUCTIONS If all emissions are below the reporting threshold, mark below as "Insignificant", and do not report on Forms 2.0 and 3.0. If one pollutant exceeds the reporting threshold, mark below as "Active" and report all pollutants on Forms 2.0 and 3.0. REPORTING THRESHOLD Pollutant PM10 SOx NOx voc co CATEGORY1 CATEGORY2 PM2.5 NH3 HAPs HAPs Threshold (lbs.) 876 2,000 2,000 876 2 , 000 20 200 876 876 Threshold (tons) 0.438 1.0 1.0 0.438 1.0 0.01 0.1 0.438 0.438 EMISSION UNIT NO. EMISSION UNIT DESCRIPTION OPERATING STATUS (CHOOSE ONE) sec (USE SAME DESCRIPTION ON FORM 2.0) Active Inactive Dismantled Under Construction Insignificant B-01 0 0 0 0 AUXILIARY BOILER 10200501 B-02 [g] D D D D EMERGENCY DIESEL GENERATOR A 20200402 B-03 [g] D D D D EMERGENCY DIESEL GENERATOR B 20200402 B-04 [g] D D D D SECURITY EMERGENCY GENERATOR 20200402 B-05 [g] D D D D TSC EMERGENCY GENERATOR 20200402 B-06 [g] D D D D EOF EMERGENCY GENERATOR 20200402 B-07 [g] D D D D FIRE PROTECTION DIESEL GENERATORS (2) 20200402 B-10 [g] D D D D PORTABLE DIESEL GENERATOR 20200402 B-12 [g] D D D D 4 Permanent Diesel Generators 20200402 B-13 [g] D D D D 5 Temporary Diesel Generators 20200402 Only emission units marked "Active" on this page will have their associated Form 2.0 and worksheet information displayed in this PDF document.
MO 780-1620 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACI LI TY NAM E FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E M I SS I ON UN I T NO. I E M I SS I ON UNIT DESCR I PT I ON B-01 AUXILIARY BO I LER 2. EMISSION PROCESS DETAIL SEG. NO. I SOURC E CLASSIFICATION COD E (SCC) SCC D E SCR I PT I ON 1 10200501 PLAN T NO. Y E AR OF DATA 0026 2010 Grades 1 and 2 Oil DO THE E MISS I ONS F ROM THIS E MISSION UNIT F L OW THROUGH A STACK OR VENT? [8j Yes D No IF YES, COMPLETE FORM 2.0S STACKNENT I NFORMATION AR E TH E E MISSIONS FROM TH I S UNIT FUGIT I VE? D Yes [8j No IF FUG I TIVE , WHAT P E RCENTAGE?
- 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS A NN UA L THROUGHPUT UNITS DE C-FEB (%) For coal or fuel oil , list details below 1.00 364.81 1 000 GALLONS MAR-MAY(%)
Heat Con lent (BT U/Fuel Unit) 98.00 137 , 000 , 000.00 HOURS/DAY D AYS/W EE K WEEKS/YEAR TOTA L HOURS/Y E AR JUN-AUG (%) ASH % (INC L U D E IN E F) 1.00 0.00 24.00 7.00 52 8 , 736.00 S EP T-NOV (%) SULFUR% (INC L UD E IN EF) 0.00 0.04 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL x Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 =Actual Emissions (tons) I n s tru c ti ons: Choose from the Lbs l unit of lhroughpul If EF includes control Combination of all I f controlled, include List Othe r Worksheets or Source of E mission mark"C" , capture and Form 2.0C Control AP-42/0ther Refe r ence Factor list otherwise "U" destruc ti on D evice Listing at lower right efficiencies PM10 FIL
- 4F 1.0000 No Control 0.00 0.18 SOURCE OF EMISSION FACTOR LIST SOx 4F 6.2480 No Control 0.00 1.14 1.CEM I n c lu de doc um e nt atio n 2. Stack Test I n c lu de doc um e nt atio n NOx 4F 20.0000 No Control 0.00 3.65 3. Mass Ba l ance I n c l ud e docu m e nt at i on 4. AP-42 I nc l ude r efe r e n ce voc 4F 0.2000 No Control 0.00 0.04 4F. FIRE or webFIRE 5. Other In c l ude doc um e nt ation co 4F 5.0000 No Control 0.00 0.91 EC. Engr Calc In c lu de doc um en t a t ion LS. Landfill Spdsht I nclude docu m e ntati o n LEAD TK. TANKS Program Suppl y TANK S o utpu t 2.3. VOC Mass Sal Comp let e F onm 2.3 HAPs 2T 0.0000 No Control 0.00 0.00 2.4. Liquid Loading Complet e F onm 2.4 2.7. Haul Road Co mp lete F o r m 2.7 PM2.5 FIL
- 2.8. Storage P i le C o mpl ete Fonm 2.8 2.T. HAP Worksheet C o mp lete F o nm 2.T NH3 2.9. Stack TesUCEM Com pl e t e F onm 2.9 2.0L. Landfill Co mp le t e F onm 2.0 L PM CON*
- If PM CON is reported, P M10 and P M25 entries above are required and should represent only the filterable PM1 0 and filtera b le PM25. MO 780-1621
DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.T HAZARDOUS AIR POLLUTANT WORKSHEET A G ILIT Y NA ME f,MEREN MISSOURI E MI SS I O N U N I T N O. B-01 F I PS COUNTY NO. PLANT N O. E A R OF DAT A 027 0026 2010 p;OURCE CLASS IF ICA TI ON CODE (SCC) EG. N u. 10200501 1 Use this form to report any Hazardous Air Pollutant, or HAP, which is emitted in any amount greater than the chemical reporting levels per each emission unit. The instructions for this form provide a list of the HAPs regulated under the Clean Air Act. The amount emitted (Column 4) should be reported before control equipment reductions are applied. Provide documentation (other worksheets, etc.) if the amount in Column 3 does not equal the amount in Column 4. The HAP reporting levels per emission unit are as follows: Category 1 HAPs-sum of 20 pounds per year; All other HAPs -sum of 200 pounds per year. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. H AP CHEMICAL C A S NU MB E R AMOUN T USED OR U NCONTROLLED UNCONTROL L ED U NCON T ROL L E D EMISSIONS HAP CON T RO L DEVICE(S)
CONTRO L CONTROLLE D EMISS I ONS CON T ROLLED E M I SSIONS H A N DLED (L B S./YR.) AMOUNT E M I TIE D EM I SS I ONS REPORTE D RE P ORTED A S HAPs (LBS./YR.) EFFIC I ENCY(%) REPORTE D A S VOC OR REPOR TE D AS H APs (L B S./YR.) AS VOC OR P M 1 0 PM 1 0 (LB S./YR.) (LBS./YR.) (LB S./YR.) S U M (L B S./YR. S U M (L B S./YR. S UM (LB S./YR. SUM (LBS./YR.) HAP Emission Totals= 0.00 0.00 0.00 0.00 Sum of uncontrolled emissions reported as HAPs 11. HAP EMISSION FACTOR Uncontrolled HAP Emission Factor= (Column 6 Totai)/Annual Throughput (Form 2.0) 0.0 Enter the HAP emission factor for all chemicals that are not reported as VOCs or PM1 0 from Block 11 above as the HAP Emission Factor in Section 5 on Form 2.0. M O 7 80-14 48 (1 2-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) B-01 10200501 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL AUXILIARY BOILER 09/04/1984 COMBUSTION ENGINEERING TYPE 18-A-13 2. OPPOSED 3. FRONT 4. DRY/WET BOTTOM OTHER (SPECIFY)
Y EAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 123.000000 Sum of total maximum hourly design rates 123.0000 COMBUSTION EQUIPMENT USE (CHECK ONE) D Electric power generation Industrial use D Commercial/Institutional D Space heating D Other (specify):
COMBUSTION EQUIPMENT CATEGORY*
COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulverized coal wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (specify):
- 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify):
oil1-4 (distillate)
D Coke oven gas OBagasse D Fuel oil 5-6 (residual)
D Liquid propane gas (LPG) OBark OGasoline D Natural gas D Bituminous coal OKerosene ocoke OLignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Des ig n Rate (mmbtu/hr.)
X 1,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.)
= Heat C onte nt (btu/fuel unit) 137,000,000.000000 0.89781 MO 780-1436 (12*09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FAC ILI TY NAME FI P S COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E M I SS I ON UN I T NO. PLAN T NO. Y E AR OF DATA 0026 2010 B-02 I E M I SS I ON UNIT D E SCRIPTION EMERGENCY DIESEL GENERATOR A 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E CLASSIF I CAT I ON COD E (SCC) SCC D E SCR I P TI ON 1 20200402 Dual Fuel (Oil/Gas)
DO TH E EM I SS I O N S F ROM TH I S E M I SSION UN I T F L OW THROUGH A STACK OR V ENT? (8]Yes DN a IF Y E S, COMP LE T E FORM 2.0S S T ACKN E NT INFORMAT I ON AR E TH E E MISS I ONS FROM TH I S UN I T F UG I TIV E? D Yes [8]No I F F UG I T I V E , WHAT PERC E NTAG E? 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPU T UNITS DEC-F EB (%) For coal or fuel oil , list details below 30.00 749.06 1000 MAR-MAY(%) Heat Content (B TU/Fuel Unit) HORSEPOWER-HOURS 55.00 137 , 000 , 000.00 H OU R S/DAY DAYS/WEEK W EE KS/YEAR TOTAL HOURS/Y E AR JU N-AUG (%) ASH % (I NC L UD E IN EF) 9.00 0.00 24.00 7.00 52 8,736.00 S EPT-NOV(%) SU L FUR% (I N C L UD E IN E F) 6.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL x Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 =Actual Emissions (tons) I n structions:
Choose fro m the L bs./unit of th r oughput If EF includes cont r o l Com b ination of all I f controlled, in dude List Othe r Worksheets or Source of E mission mark"C", capture and F orm 2.0C Control AP-42/0ther Reference Facto r list otherwise "U" destruction Device Listing at lower r ight efficiencies PM10 FIL
- 4F 0.7000 No Control 0.00 0.26 SOURCE OF EMISSION FACTOR LIST SOx 4 F 8.0900 No Control 0.00 3.03 1. CEM In c lu de do c u men tat i o n 2. Stack Test I nc l ude d ocu m e n ta ti o n NOx 4F 24.0000 No Control 0.00 8.99 3. Mass Balance In cl u de d o c u m en t a t ion 4. AP-42 I ncl u de r efe r e n ce voc 4F 0.7100 No Control 0.00 0.27 4F. FIRE or webFIRE 5. Oth e r In c l u d e d oc u me nt a ti o n co 4F 5.5000 No Control 0.00 2.06 EC. Engr Ca l c In c lud e do c u me nt atio n LS. Landfill Spdsht In cl u de d ocu m e nt ation LEAD TK. TANKS Program S up pl y TANK S ou tpu t 2.3. VOC Mass Bal C om pl e t e F o nm 2.3 HAPs 2.4. Liquid Load i n g C o mpl e t e F o nm 2.4 2.7. Hau l Road C o mpl e t e F o nm 2.7 PM2.5 FIL
- 2.8. Storage Pile Co mplete F onm 2.8 2.T. HAP Worksheet C o mpl e t e F o nm 2.T NH3 2.9. Stack Test/GEM C o mplet e F o nm 2.9 2.0L. Landfill Compl e t e F o nm 2.0 L PM CON* " I f PM CO N is r eported, PM10 a n d P M25 entries above are required and should r ep r esent only the filte r able PM10 an d filterable PM 25. MO 780-1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) B-02 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL EMERGENCY DIESEL GENERATOR A 09/04/1984 8600 HP COLT INDUSTRIES MODEL PC 2.5 2. OPPOSED 3. FRONT 4. DRY/WET B OTIOM OTHER (SPECIFY)
Sum of total maximum hourly design rates COMBUSTION EQUIPMENT USE (CHECK ONE) Y EAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 58.000000 58.0000 D Electric power generation use D Commercial/Institutional D Space heating D Other (specify): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulverized coal wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (specify):
- 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify):
oil1-4 (distillate)
D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual)
D Liquid propane gas (LPG) 0Bark OGasoline D Natural gas D Bituminous coal OKerosene ocoke D Lignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Design Rate (mmbtu/hr.)
X 1 ,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.) Heat Content (btu/fuel unit) 137,000,000.000000 0.42336 MO 780-1436 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EMISS I ON UNIT NO. PLANT NO. Y E AR OF DATA 0026 2010 B-03 I EM I SSION UNIT DESCRIPT I ON EMERGENCY DIESEL GENERATOR B 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E CLASSIFICATION CODE (SCC) SCC D E SCRIPTION 1 20200402 Dual Fue l (Oil/Gas)
DO THE EM I SSIONS FROM TH I S E MISSION UNIT FLOW THROUGH A STACK OR VEN T? (8]Yes O No I F YES , COMP L E T E FORM 2.0S STACKN E NT I N F ORMAT I ON ARE TH E EM I SSIONS FROM T H I S U NI T F UG ITI VE? D Yes [8J No IF FUG I TIV E , WHAT PERC E NTAGE? 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPUT UNITS D E C-FEB(%) For coal or fue l o i l, list details below 19.00 608.02 1000 MAR-MAY(%)
Heat Content (BTU/Fuel Unit) HORSEPOWER-HOURS 60.00 137 , 000 , 000.00 HOURS/DAY DAYS/W EE K WEEKS/YEAR TOTAL HOURS/YEAR JUN*AUG(%)
ASH % (INCLUDE IN E F) 10.00 0.00 24.00 7.00 52 8 , 736.00 SEPT-NOV(%) SU L FUR% (I NC L UDE IN EF) 11.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONSNR) X STATUS (%FORMAT)
+ 2000 = Actual Emissions (tons) I n s t ructions:
Choose from the Lbs J unit of throughput I f EF includes control Com b ination of all If controlled, include List Other Worksheets or Source of E mission mark*c", capture and Form 2.0C Control AP-42/0ther Reference Fac t or list otherwise "U" destruction Device Listing a t lower right efficiencies PM10 FIL
- 4F 0.7000 No Control 0.00 0.21 SOURCE OF EMISSION FACTOR LIST SOx 4F 8.0900 No Control 0.00 2.46 1. CEM I n c lud e docu m e ntati o n 2. Sta ck Test In c l ude doc um entatio n NOx 4 F 24.0000 No Control 0.00 7.30 3. M ass Ba l an c e In clude documenta t io n 4. AP-4 2 I nclude r eference voc 4F 0.7100 No Control 0.00 0.22 4F. FIRE or webFIRE 5. Oth e r In c l ude docume n tation co 4F 5.5000 No Contro l 0.00 1.67 EC. Eng r Calc I n c lu de docume nt ation LS. Landfill Spdsht I n c lud e documen t ation LEAD TK. TANKS Program Suppl y TANKS o utpu t 2.3. VOC Mass Bal Compl e t e F o rm 2.3 HAPs 2.4. Liquid Loading C o mp le t e F o rm 2.4 2.7. Haul Road Comp lete F orm 2.7 PM2.5 FIL
- 2.8. Storage P i le C o mp l e te F orm 2.8 2.T. HAP Wo rk sheet Comp lete Fo rm 2.T NH3 2.9. S t ack Tes t/CEM C om pl ete F orm 2.9 2.0L. Landfi ll C o mp lete F orm 2.0L PM CON*
- If PM CON is reported, PM10 and PM25 entries above are required and should r ep r esen t only the filterable PM10 and fil t erable P M25. MO 78G-1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FAC I LITY NAME FIPS COUNTY NO. PLAN T NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFIC A TION CODE (SCC) B-03 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL EMERGENCY DIESEL GENERATOR B 09/04/1984 8600 HP COLT INDUSTRIES MODEL PC 2.5 2. OPPOSED 3. FRONT 4. DRY/WET BOTTOM OTHER (SPECIFY) Sum o f tota l max im um hou r ly des i gn ra t es COMBUSTION EQUIPMENT USE (CHECK ONE) YEAR OF DATA 2010 SEG. N O. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 58.000000 58.0000 D Electr i c power generation use D Commercial
/Institutional D Space heating D Other (specify): COMBUSTION EQUIPMENT CATEGORY*
COAL USE ONLY (CHECK ONE) D Pu l ver i zed coa l D Pulver i zed coa l dry bottom D Pulverized coa l wet bottom Ocyclone D Flu i d i zed bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fi red D Other (spec i fy): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthrac i te Coal D Other (spec i fy):
oi l 1-4 (distillate) D Coke oven gas OBagasse D Fuel o il 5-6 (res i dual} D Liqu i d propane gas (LPG) OBark OGaso li ne D Nat u ra l gas D Bitum i nous coal D Kerosene oco k e OL i gn i te D Subbituminous coa l owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maxim u m D esign R ate (mmb tu/hr.) X 1,000,000 (btu/mm b tu) (BTU/FUEL UNIT) (FUEL UNIT/HR.)
= Heat Content (btu/fuel u n i t) 137 , 000 , 000.000000 0.42336 MO 780.1436 (1 2-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EMISSION UNIT NO. PLANT NO. YEAR OF DATA 0026 2010 B-04 I EMISSION UNIT DESCRIPTION SECURITY EMERGENCY GENERATOR
- 2. EMISSION PROCESS DETAIL SEG. NO. I SOURCE ClASSIFICATION CODE (SCC) SCC DESCRIPTION 1 20200402 Dual Fuel (Oil/Gas)
DO THE EMISSIONS FROM THI S EMISSION UNIT FLOW THROUGH A STACK OR VENT? (8J Yes DN a IF YES, COMPLETE FORM 2.0S STACKNENT INFORMATION ARE THE EMISSIONS FROM THIS UNIT FUGITIVE?
D Yes [8J No IF FUGITIVE, WHAT PERCENTAGE?
- 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUAL THROUGHPUT UNITS DEC-FEB (%) For coal or fuel oil , list details below 7.00 18.03 1000 MAR-MAY(%)
Heat Content (BTU/Fue l Unit) HORSEPOWER-HOURS 1.00 137,000,000.00 HOURS/DAY DAYS/WEEK WEEKS/YEAR TOTAL HOURS/YEAR JUN-AUG (%) ASH% (INCLUDE IN EF) 87.00 0.00 24.00 7.00 52 8,736.00 SEPT-NOV(%)
SULFUR % (INCLUDE IN EF) 5.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 =Actual Emissions (tons) Instructions:
Choose from the Lbs./unit of throughput If EF includes control Combination of all If controlled, include List Other Worksheets or Source of Em ission mark"C", capture and Form 2.0C Control AP-42/0ther Reference Factor list otherwise "U" destruction Device List ing at lower right efficiencies PM10 FIL
- 4F 0.7000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 8.0900 No Control 0.00 0.07 1. CEM Include documentation
- 2. Stack Test Include documentation NOx 4F 24.0000 No Control 0.00 0.22 3. Mass Balance Include documentation
- 4. AP-42 Include reference voc 4F 0.7100 No Control 0.0 0 0.01 4F. FIRE or webFIRE 5. Other Include documentation co 4F 5.5000 No Control 0.00 0.05 EC. Engr Calc Include documentation LS. Landfill Spdsht Include documentation LEAD TK. TANKS Program Supply TANKS output 2.3. VOC Mass Bal Complete Fonn 2.3 HAPs 2.4. Liquid Loading Complete Fonn 2.4 2.7. Haul Road Complete F onn 2.7 PM2.5 FIL
- 2.8. Storage Pile Complete F onn 2.8 2.T. HAP Worksheet Complete F onn 2.T NH3 2.9. Stack Test/GEM Complete Fonn 2.9 2.0L. Landfill Complete Fonn 2.0L PM CON*
- If PM CON is reported, PM10 and PM25 entries above are required and should represent only the filterable PM1 0 and filterable PM25. MD 780-1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FAC ILI TY NAME F I PS COU N TY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT E M I SS I ON UN I T NO. SOU R C E CLASS I FICA T ION COD E (SCC) B-04 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANG E NTIAL SECURITY EMERGENCY GENERATOR 09/04/1984 644 HP GENERAL ALLISON DETROIT MFG MODEL V71 2. OPPOSED 3. FRONT 4. DRY/WET BOTTOM OTH E R (SPEC I FY) Sum of tota l maximum hourly des i gn rates COMBUSTION EQUIPMENT USE (CHECK ONE) Y E AR OF DATA 2010 S E G. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 1.700000 1.7000 D Electr i c power generat i on Industrial use D Commerc i a l/Institutional D Space heat i ng D Othe r (specify): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulver i zed coal D Pulver i zed coal dry bottom D Pulverized coa l wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (spec i fy): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (spec i fy):
oil1-4 (distillate) D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual) D Liquid propane gas (LPG) 0Bark OGasoline D Natura l gas D B i tuminous coal D Kerosene ocoke OLignite D Subbituminous coa l owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Max imum D esig n Rat e (mm b tu/h r.) X 1 ,000,0 0 0 (bt u/m m bt u) (BTU/FUEL UNIT) (FUEL UNIT/HR.)
= Heat Co n te n t (btu/fue l unit) 137,000 , 000.000000 0.01241 MO 78()..1436 (12*09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FAC ILI TY NAME FI PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E MISSION UNIT NO. PLAN T NO. Y E AR OF D ATA 0026 2010 B-05 I E MISSION UN IT D E SCR I PTION TSC EMERGENCY GENERATOR
- 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E ClASSI FI CA T ION COD E (SCC) SCC D E SC RI PTION 1 20200402 Dual Fuel (Oil/Gas)
DO TH E E MISSIONS FROM T H I S EM I SSION UNIT F L OW THROUGH A STACK OR V E NT? O No IF Y E S, COM PL E T E FORM 2.0S STACKN E NT IN FORMATION ARE T HE EM I SSIONS FROM TH I S UNIT F UGIT I V E? D Yes IF FUG I TIV E , WHAT P E RC E NTAG E? 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUA L TH ROUG HP UT UNI T S DEC-F EB (%) For coal or fuel oil , l i st details below 34.00 4.83 1000 MAR-MAY(%)
Heat Content (B T U/F uel Unit) HORSEPOWER-HOURS 26.00 137 , 000 , 000.00 H OURS/DAY D AYS/W E EK WEEKS/YEAR TOTAL HOURS/Y E AR JUN-AUG (%) ASH % (I NC L UD E I N E F) 21.00 0.00 24.00 7.00 52 8 , 736.00 S E PT-N OV(%) SU L FUR% (I NC L UDE IN E F) 19.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISS I ON OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONSIYR)
X STATUS (%FORMAT)
+ 2000 =Actual Emissions (tons) I n struc t io n s: Choose from the L bs./unit of th r oughput If E F includes control C ombination of all I f controlled, include List Othe r Worksheets o r Source of E mission ma r k"C", capture and F onn 2.0C Control A P-42/0ther Reference Factor list otherwise destruction Device Listing at lower right efficiencies PM10 FIL
- 4F 2.2000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 2.0500 No Control 0.00 0.00 1. CEM Includ e d o cumen ta t io n 2. S t ack Test I ncl u de docu m e n ta t io n NOx 4F 31.0000 No Control 0.00 0.07 3. Mass Balance I nc l ude documentation
- 4. AP-42 In clude refe re nce voc 4F 2.4700 No Control 0.00 0.01 4F. FIRE or webFIRE 5. Ot h er I n c l ud e doc u me nt ation co 4F 6.6800 No Control 0.00 0.02 EC. Engr Calc I n c lu de docu m e nt at i o n LS. Landfill Spdsht I n c lu de doc um e nt at i o n LEAD TK. TANKS Program S u pp ly TA N K S o utput 2.3. VOC Ma s s Bal C om p lete F orm 2.3 HAPs 2.4. Liqu i d Load i ng C o mpl e t e F orm 2.4 2.7. Hau l Road C om pl e t e Fo rm 2.7 PM2.5 FIL
- 2.8. Storage Pile Compl e t e F o rm 2.8 2.T. HAP Worksheet C o mpl e t e F o rm 2.T NH3 2.9. Stack TestJCEM Comp le t e F orm 2.9 2.0L. Landfill C o mp lete Form 2.0 L PM CON* "If P M CON is r eported, P M10 and P M25 entries above are required and sho u ld represent only the filterable PM1 0 an d filterable PM 2 5. MO 780-1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET F AC ILI TY NAM E FIP S COU N TY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMI S SI ON UN IT NO. SOURC E CLASS IFI CA TI ON CO DE (SCC) B-05 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANG EN T I AL TSC EMERGENCY DIESEL GEN 09/04/1984 355 HP CUMMINS MOD NT-835GS 2. OP P OS E D 3. F RONT 4. DRY/W ET BO TT OM OTH E R (S PE C IF Y) Y E A R O F D A T A 2010 S E G. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 0.800000 Sum of total maximum hourly design rates 0.8000 COMBUSTION EQUIPMENT USE (CHECK ONE) D Electric power generation Industr i al use D Commercial/Institut i onal D Space heating D Other (spec i fy): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulver i zed coal dry bottom D Pulverized coal wet bottom Ocyclone 0 Fluid i zed bed 0 Spreader stoker 0 Overfeed stoker 0 Underfeed stoker 0Hand fired 0 O t her (spec i fy): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify):
oil1-4 (distillate) D Coke oven gas D Bagasse D Fuel oil 5-6 (residual)
D Liquid propane gas (LPG) 0Bark OGasoline D Natu r al gas D Bituminous coal OKerosene ocoke OLignite D Subbitum i nous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Ma xi m um D e sig n R a te (mmbtu/hr.) X 1 ,000, 0 00 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.)
= H eat C o n te n t (b t u/fue l unit) 137 , 000,000.000000 0.00584 MO 78()..1 4 36 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACI LI TY NAM E FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E MISSION UNIT NO. PLANT NO. Y E AR O F DATA 0026 2010 B-06 I EMISS I ON UN I T DESCR I PTION EOF EMERGENCY GENERATOR
- 2. EMISSION PROCESS DETAIL S E G. NO. t SOURC E CLASSIFICA T ION CODE (SCC) SCC D E SCRIPTION 1 20200402 Dual Fuel (Oil/Gas) DO T H E E MISS I ONS FROM TH I S EM I SSION UNIT F L OW THROUGH A STACK OR V E NT? [8)Yes D Na I F Y E S, COM PLE T E FORM 2.0S S T ACKN E NT INFORMAT I ON ARE THE E M I SS I ONS F ROM THIS UN I T FUG I TIVE? D Yes [8J No I F FUGI TI V E , WHAT P ERCENTAG E? 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPUT UNITS D E C-F EB (%) For coal or fuel oil , list deta i ls below 33.00 8.08 1000 MAR-MAY(%)
Heat Content (BTU/Fuel Unit) HORSEPOWER-HOURS 29.00 137,000 , 000.00 HOURS/DAY DAYS/WEEK W EE KS/YEAR T OTAL HOURS/Y E AR JUN-AUG (%) ASH% (INC L UDE I N EF) 22.00 0.00 24.00 7.00 52 8 , 736.00 SEPT-NOV(%)
SU LF UR % (I NC L UDE I N E F) 16.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 =Actual Emissions (tons) I ns tru ct i o n s: Choose from the L bs./unit of throughput I f EF includes cont r ol Combination of all I f controlled, indude List Othe r Worksheets or Source of Emission mark"C" , cap t ure and Form 2.0C Control AP-42/0the r Refe r ence Factor list otherwise "U" destruction Device Listing at lowe r right efficiencies PM10 FIL
- 4F 2.2000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 2.0500 No Control 0.00 0.01 1. CEM In clude doc um e nt a ti o n 2. Stac k Te s t In c l ude docume n ta ti o n NOx 4F 31.0000 No Control 0.00 0.13 3. M as s Balan c e In cl ud e do c u m enta t ion 4. AP-42 I ncl u de r eference voc 4F 2.4700 No Control 0.00 0.01 4F. FIRE or web FIRE 5. Other In c lu de d oc u me n ta ti o n co 4F 6.6800 No Control 0.00 0.03 EC. Engr Calc Inclu de docume nt a t ion LS. Landfill Spdsht In cl u de d ocu m entatio n LEAD TK. TANKS Program S u pp ly TA N KS o utp u t 2.3. V OC Mas s Bal Co mpl e t e F orm 2.3 HAPs 2.4. Liqu i d Load i ng C o mpl et e F orm 2.4 2.7. Hau l Road Com pl e t e F orm 2.7 PM2.5 FIL
- 2.8. Storage P i le C o mple te F o rm 2.8 2.T. HAP Worksheet C om pl e te F orm 2.T NH3 2.9. Stack Tes t/GEM Co mp le t e F orm 2.9 2.0L. Landfill C o m p lete F orm 2.0 L PM CON* 'I f P M CO N is reported, P M10 and P M25 entries above are requi r ed and should represent only the filterable PM10 and filterable PM25. MO 780-1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION COD E (SCC) B-06 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. TANGENTIAL EOF EMERGENCY GENERATOR 09/04/1984 565 HP CUMMINS MODEL KTA-1150-GS-1
- 2. OPPOSED 3. FRONT 4. DRY/WET B OTTOM OTHER (SPEC IF Y) Sum of total maximum hourly design rates COMBUSTION EQUIPMENT USE (CHECK ONE) YEAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 1.200000 1.2000 0 Electric power generation use O Commercial/Institutional O Space heating O Other (specify):
COMBUSTION EQUIPMENT CATEGORY -COAL USE ONLY (CHECK ONE) 0 Pulverized coal O Pulver i zed coal dry bottom O Pulverized coal wet bottom Ocyclone D Fluidized bed 0 Spreader stoker 0 Overfeed stoker 0 Underfeed stoker 0Hand fired D Other (specify):
- 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol 0 Blast oven gas 0 Anthracite Coal O Other (specify):
oil1-4 (distillate)
O Coke oven gas 0Bagasse 0 Fuel oil 5-6 (residual) 0 Liquid propane gas (LPG) 0Bark OGasoline O Natural gas O Bituminous coal D Kerosene ocoke D Lignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Desig n Rate (mmb tu/h r.) X 1 ,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.)
= Heat Content (btu/fuel unit) 137,000,000.000000 0.00876 MD 780-14 36 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME F IP S COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E MISSION UNIT NO. PLANT NO. YEAR OF DATA 0026 2010 B-07 I EMISSION UN I T DESCRIPTION FIRE PROTECTION DIESEL GENERATORS (2) 2. EMISSION PROCESS DETAIL SEG. NO. I SOURC E CLASSI FI CA T ION CODE (SCC) SCC D E SCRI PTI ON 1 20200402 Dual Fuel (Oil/Gas)
DO T H E E MISS I ONS FROM TH I S E M I SSION UNIT F LOW THROUGH A STACK OR V E NT? [Rj Yes D Na IF Y E S, COMP LE TE FORM 2.0S S T ACKN E N T IN F ORMAT I ON AR E T H E EM I SS I ONS F ROM THIS UN IT F UG I TIVE? D Yes [Rj No IF FUG I T I V E , WHAT P E RCEN T AG E? 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS AN N UA L THROUGH P UT U NI TS D E C-F E B (%) For coal or fuel oil , list details below 20.00 7.65 1000 MAR-MAY(%)
Heat Content (B TU/Fuel Unit) HORSEPOWER-HOURS 27.00 137 , 000 , 000.00 HOURS/D AY DAYS/W EE K W EE KS/YEAR TO T A L HOURS/Y E AR JUN-AUG (%) ASH% (INCLUDE IN EF) 36.00 0.00 24.00 7.00 52 8,736.00 S EP T-NOV(%) SU L FUR% (I NCLUD E IN EF) 17.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 =Actual Emissions (tons) I nst ru ct i o n s: Choose f r om the L bs./unit of throughput I f E F includes control Combination of all I f controlled, include List Other Worksheets o r Source of E mission mark"C", capture and Form 2.0C Control AP-42/0ther Refe r ence Facto r l ist otherwise "U" destruction Device Listing at lower right efficiencies PM10 FIL
- 4F 2.2000 No Control 0.00 0.01 SOURCE OF EMISSION FACTOR LIST SOx 4F 2.0500 No Control 0.00 0.01 1. CEM In cl ud e d ocu mentat io n 2. Stack Test In clude doc u me n tati o n NOx 4F 31.0000 No Control 0.00 0.12 3. Mass Balance I nclude docume ntatio n 4. AP-42 Include r efe r e n ce voc 4F 2.4700 No Contro l 0.00 0.01 4F. F I RE or web F I RE 5. Other Incl ud e docu m e nt atio n co 4F 6.6800 No Control 0.00 0.03 EC. E n gr Ca l c In clu d e d o cu m e n ta t io n LS. Landfill Spdsht In cl u de docu m e nt a t io n LEAD TK. TANKS Program S up p ly TANK S o u tpu t 2.3. VOC Mass Bal Com p le t e F orm 2.3 HAPs 2.4. Liquid Load i ng C o mp lete F orm 2.4 2.7. Haul Road C o mpl e t e F orm 2.7 PM2.5 FIL
- 2.8. Storage P i le C om plete F o rm 2.8 2.T. HAP Worksheet C o mpl e t e F o rm 2.T NH3 2.9. Stack Test/GEM Co mpl e te Fo rm 2.9 2.0L. Landfi l l C om pl e t e F o rm 2.0 L PM CON* 'I f P M C ON is reported, P M10 and P M25 entries above a r e r e qu ire d and should r ep r esent on l y the filterable P M1 0 and filterable P M25. MO 780-1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAME FIPS COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) B-07 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. T ANG ENTIAL FIRE PROTECTION DIESEL GEN 09/04/1984 (2) 255 HP CUMMINS NT-855-F1
- 2. OPPOS ED 3. FRONT 4. DRY/WET BOTTOM OTH ER (S PECIFY) Sum of total maximum hourly design rates COMBUSTION EQUIPMENT USE (CHECK ONE) YEAR OF DATA 2010 SEG. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 1.200000 1.2000 D Electric power generation Industrial use D Commercial/Institutional D Space heating D Other (specify):
COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulverized coal wet bottom Ocyclone D Fluidized bed D Spreader stoker D Overfeed stoker D Underfeed stoker D Hand fired D Other (specify):
- 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (specify):
oil1-4 (distillate)
D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual)
D Liquid propane gas (LPG) 0Bark OGasoline D Natural gas D Bituminous coal OKerosene ocoke D Lignite D Subbituminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum Design Rate (mmbtu/hr.)
X 1 ,000,000 (btu/mmbtu) (BTU/FUEL UNIT) (FUEL UNIT/HR.)
= Heat Content (btu/fuel unit) 137,000,000.000000 0.00876 MO 780-1436 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAM E FI PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EM I SS I O N UN I T N O. P LAN T NO. YEAR OF DATA 0026 2010 B-10 I E M I SS I ON UNIT D E SCR I PT I O N PORTABLE DIESEL GENERATOR
- 2. EMISSION PROCESS DETAIL S E G. NO. I SOURC E CLASS I FICATION CODE (SCC) SCC D E SCR I PT I ON 1 20200402 Dual Fue l (Oil/Gas) DO TH E EMISSIO N S FRO M TH I S E MISSION UNIT FL OW THROUGH A S T ACK OR V E NT? D Yes [8]No I F Y E S, COMP L ET E FORM 2.0S STACKN E NT INFORMATION ARE T H E E M I SSIONS FROM T H I S U N I T F UGITIV E? (8]Yes O No I F FUGITIV E , WHAT P E RC E N T AG E? 100.00 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPU T UN I TS DEC-FEB (%) For coal o r fuel oil, list details below 0.00 0.00 1000 MAR-MAY(%)
Heat Content (B TU/F ue l Unit) HORSEPOWER-HOURS 0.00 137 , 000,000.00 HOURS/DAY DAYS/W E EK W EE KS/YEAR TOTA L HOURS/Y E AR JU N-AUG (%) ASH % (INC L UDE IN EF) 0.00 0.00 24.00 7.00 52 8 , 736.00 S EPT-NOV(%) SULFUR% (INC L UD E IN E F) 0.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL x Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 =Actual Emissions (tons) I n s tru c t ions: Choose f r om the L bs./unit of throughput If EF includes cont r ol Combination of all If controlled, include List Other Worksheets or Source of E mission mark"C", captu r e and Form 2.0C Control AP-42/0the r Refe r ence F ac t or list otherwise "U" destruction Device List i ng at lower right efficie n cies PM10 FIL
- 4F 42.4700 No Control 0.00 0.00 SOURCE OF EMISSION FACTOR LIST SOx 4F 39.7300 No Control 0.00 0.00 1. CEM In cl ud e d o cu m e n ta ti o n 2. Stac k Test In c l ude docu m e nt a t io n NOx 4F 604.1700 No Control 0.00 0.00 3. Mass Ba l ance In c l ude doc um e nt at i o n 4. AP-42 I n c lu de re f er e n ce voc 4F 47.9500 No Control 0.00 0.00 4F. FIRE or webFIRE 5. Other In c l ude d oc um e n ta tion co 4F 130.1500 No Control 0.00 0.00 EC. Engr Calc In c lu de d ocu m e nt ati on LS. Landfill Spdsht I n c l ude docu m e nt ation LEAD TK. TANKS Program Suppl y TAN KS output 2.3. VOC Mass Bal C o mplete Form 2.3 HAPs 2.4. Liqu i d Load i ng C o mplet e Form 2.4 2.7. Haul Road C o mpl e t e F o rm 2.7 PM2.5 FIL
- 2.8. Storage Pile C om plet e Form 2.8 2.T. HAP Worksheet Co mp lete F orm 2.T NH3 2.9. Stac k Test/GEM Comple te F orm 2.9 2.0L. Landfil l C o mplete F o rm 2.0 L PM CON*
- If PM CON is reported, PM1 0 and PM25 entries a bove are r equire d and should represent only the filterable PM10 and filterable P M25. MO 780-1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.1 FUEL COMBUSTION WORKSHEET FACILITY NAM E FI P S COUNTY NO. PLANT NO. AMEREN MISSOURI 027 0026 CALLAWAY NUCLEAR POWER PLANT E MISS I ON UN I T NO. SOURCE CLASSIF I CA T ION COD E (SCC) B-10 20200402 1. COMBUSTION EQUIPMENT INFORMATION COAL FIRING YEAR COAL FIRING EQUIPMENT DESCRIPTION PUT IN CODE NO. CODE LIST SERVICE (CODE LIST AT LEFT) 1. T A NGENTIA L KOHLER 180 KW DIESEL GENERATOR 09/04/1995 MODEL# 180ROZJ 2. O P POSED 3. FRONT 4. DRY/WET BOTTOM OTHER (SPECIFY) Sum of total ma x imum hourly des i gn rates COMBUSTION EQUIPMENT USE (CHECK ONE) Y E AR O F DATA 2010 S E G. NO. 1 MAXIMUM DESIGN RATE (MILLION BTU/HR.) 3.905000 3.9050 Electric power generation D Industrial use D Commercial/Institut i onal D Space heating D Other (spec i fy): COMBUSTION EQUIPMENT CATEGORY-COAL USE ONLY (CHECK ONE) D Pulverized coal D Pulverized coal dry bottom D Pulver i zed coal wet bottom Ocyclone D Flu i dized bed D Spreader stoker D Overfeed stoker D Underfeed stoker 0Hand fired D Other (specify): 2. FUEL INFORMATION (CHECK ONLY ONE) LIQUID FUELS GASEOUS FUELS SOLID FUELS OTHER OEthanol D Blast oven gas D Anthracite Coal D Other (spec i fy):
oil1-4 (dist i llate) D Coke oven gas 0Bagasse D Fuel oil 5-6 (residual} D Liquid propane gas (LPG) OBark OGasol i ne D Natural gas D Bituminous coal D Kerosene ocoke OL i gnite D Subb i tuminous coal owood 3. CALCULATION OF MAXIMUM HOURLY DESIGN RATE TOTAL HEAT CONTENT MAXIMUM HOURLY DESIGN RATE Maximum D esign Rate (mmb t u/hr.) X 1.000.000 (b tu/m mbt u) (BTU/FUEL UNIT) (FUEL UNIT/HR.)
= H eat Content (btu/fuel u n it) 137 , 000 , 000.000000 0.02850 MO 780.14 3 6 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION EMISSION UNIT NO. PLANT NO. YEAR OF DATA 0026 2010 B-12 I EMISSION UNIT DESCRIPTION 4 Permanent Diesel Generators
- 2. EMISSION PROCESS DETAIL SEG. NO. I SOURCE CLASSIFICATION CODE (SCC) SCC DESCRIPTION 1 20200402 Dual Fuel (Oil/Gas)
DO THE EMISSIONS FROM THIS EMISSION UNIT FLOW THROUGH A STACK OR VENT? (8J Yes D Na IF YES, COMPLETE FORM 2.0S STACKNENT INFORMATION ARE THE EMISSIONS FROM THIS UNIT FUGITIVE?
D Yes [8}No IF FUGITIVE, WHAT PERCENTAGE?
- 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUAL THROUGHPUT UNITS DEC-FEB(%)
For coal or fuel oil, list deta ils below 0.00 261.00 1000 MAR-MAY(%) Heat Con lent (BTU/Fuel Un i t) HORSEPOWER-HOURS 0.0 0 HOURS/DAY DAYS/WEEK WEEKS/YEAR TOTAL HOURS/YEAR JUN*AUG (%) ASH % (INCLUDE IN EF) 0.00 0.00 8.00 5.00 52 2 , 080.00 SEPT-NOV (%) SULFUR % (INCLUDE IN EF) 100.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 = Actual Emissions (tons) Instructions
- Choose from the Lbs J unit of throughput If EF i ncludes control Combination of all If controlled, indude List Other Worksheets or Source of Emission mark"C", capture and Form 2.0C Control AP-42/0ther Reference Factor list otherwise "U" destruction Device Listing at lower right efficiencies PM10 FIL
- 5 -Manufacturer 0.1200 No Control 0.00 0.02 SOURCE OF EMISSION FACTOR LIST Specifications SOx 5 0.0100 No Control 0.00 0.00 1. CEM Include documentation
- 2. Stack Test Include documentation NOx 5 11.0000 No Control 0.00 1.44 3. Mass Balance Include documentation
- 4. AP-42 Include reference voc 5 0.5200 No Control 0.00 0.07 4F. FIRE orwebFIRE
- 5. Other Include documentation co 5 1.1100 No Control 0.00 0.14 EC. Engr Calc Include documentation LS. Landfill Spdsht Include documentation LEAD TK. TANKS Program Supply TANKS output 2.3. VOC Mass Ba l Complete Form 2.3 HAPs 2.4. Liquid Loading Complete Form 2.4 2.7. Haul Road Complete Form 2.7 PM2.5 FIL
- 2.8. Storage P ile Complete Form 2.8 2.T. HAP Worksheet Complete Form 2.T NH3 2.9. Stack TestJCEM Complete Form 2.9 2.0L. Landfill Complete Form 2.0L PM CON* "If PM CON is reported, PM10 and PM25 entries above are required and should represent only the filterable PM1 0 and fillerable PM25. MO 780--1621 (05-10)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0 EMISSION UNIT INFORMATION FACI LI TY NAM E F I PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT 1. EMISSION UNIT IDENTIFICATION E M I SSION UNIT NO. PLA N T NO. YEAR O F DATA 0026 2010 B-13 I EMISSION UN I T DESCR I PTION 5 Temporary Diesel Generators
- 2. EMISSION PROCESS DETAIL S E G. NO. I SOURCE CLASSI FI CATION CODE (SCC) SCC D E SCR I PTION 1 20200402 Dual Fue l (Oil/Gas) DO THE E M I SS I ONS F ROM THIS E MISS I ON UNIT F L OW THROUGH A S T ACK OR V E NT? (8]Yes D No IF Y E S , COMP LE T E F ORM 2.0S STACKNENT I N F ORMATION ARE TH E E M I SS I ONS FROM THIS UN I T FUG IT IV E? D Yes [8J No I F FUGIT I VE, WHAT P E RC E NTAG E? 3. OPERATING RATE/SCHEDULE
- 4. ANNUAL FUEL CHARACTERISTICS ANNUA L THROUGHPUT UN I TS DE C-F EB (%) For coal or fuel oil , list details below 50.00 22.99 1000 MAR-MAY(%)
Heat Con lent (BTU/Fuel Unit) HORSEPOWER-HOURS 0.00 HOURS/D AY DAYS/W EE K W EE KS/YEAR TOTAL HOURS/YEAR JUN-AUG (%) ASH% (I NC L UDE IN EF) 50.00 0.00 8.00 5.00 52 2 , 080.00 SEPT-NOV(%)
SU L FUR % (INC L UD E I N E F) 0.00 0.00 5. EMISSION CALCULATIONS AIR 1. 2. 3. 4. 5. Annual Throughput POLLUTANT SOURCE OF EMISSION EMISSION OVERALL ACTUAL X Emission Factor EMISSION FACTOR FACTOR(EF)
CONTROL EMISSIONS (1-0verall Control Eff/1 00) FACTOR CONTROL EFFICIENCY (TONS/YR)
X STATUS (%FORMAT)
+ 2000 = Actual Emissions (tons) I n s t ruc ti ons: Choose from the Lbs./unit of throughput If EF includes cont r ol Combination of all If controlled , include List Other Worksheets or Source of E mission ma r k"C" , capture and Form 2.0C Control AP-42/0ther Reference Factor list otherwise "U" destruction Device Listing at lower right efficiencies PM10 FIL
- 5 -Manufacturer' s 0.1200 No Control 0.00 0.00 SOURCE OF EMISSION FACTOR LIST S p e ci ficat i on s SOx 5 0.0100 No Contro l 0.00 0.00 1.CEM I n cl u de documen tat io n 2. Stac k Test In clude docume n ta ti o n NOx 5 11.0000 No Control 0.00 0.13 3. M ass Balance In cl ud e docume n ta t io n 4. AP-4 2 In c l ude r efe r e n ce voc 5 0.5200 No Control 0.00 0.01 4F. FIRE or we b FIRE 5. Other I n c lu d e docume n tation co 5 1.1100 No Control 0.00 0.01 EC. Eng r Calc I n cl u de documentatio n LS. Land fi ll Spdsh t In c lu d e documen t ation LEAD TK. TANKS Program S u ppl y TANKS ou tpu t 2.3. VOC Mass Ba l Compl e t e F o rm 2.3 HAPs 2.4. Liquid Loading C omp l e t e Fo rm 2.4 2.7. Haul Road C o mp lete F o rm 2.7 PM2.5 FIL
- 2.8. Storage P i le C o mpl e te F orm 2.8 2.T. HAP Worksheet C om p l e te F o rm 2.T NH3 2.9. Stack TesUCEM C o mpl e t e F o rm 2.9 2.0L. Landfill Com p le t e F orm 2.0 L PM CON*
- I f PM CON is r eported, P M10 and P M25 entries above a r e r e q ui r ed and should rep r esent only the filterable PM1 0 and filterable P M25. MO 780-1621 (05-1 0)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0S STACKNENT INFORMATION FACILITY NAME F I PS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT EM I SS I ON UNIT NO. SOURCE CLASSIFICATION COD E (SCC) SEG. NO. B-01 10200501 1 STACK/VENT NO. STACK/VENT DESCRIPTION S-1 PLANT NO. YEAR O F DATA 0026 2010 FOR A NON-C I RCULAR STACK: 0 Vent DIAMET E R= (1.128A)'1/2 (A=CROSS SECTIONAL AREA IN sa FEET) %OF EMISSIONS RE L EASED 100.00 STACK/VENT O P ERATING STATUS (CHECK ONE)
O lnactive O oismantled HE I GHT (FT.) DIAM E T ER (FT.) TEMPERATURE (F) V EL OCITY (FT./M I N.) F L OW RAT E (CU F T./MIN.) LI ST OTH E R P O I NTS SHARING T HIS STACK/VENT 150.00 5.000 655.00 2 , 254.00 44 , 179.00 EM I SSION UNIT NO. SOURCE CLASSIF I CAT I ON COD E (SCC) S E G. NO. FOR A NON-C I RCULAR STACK: B-02 20200402 1 0 Vent DIAM E T E R= (1.128A)'1/2 (A=CROSS S E CTIONAL AREA I N Sa F EET) STACK/VENT NO. STACK/V E NT DESCR I PT I ON % OF EMISS I ONS R E LEASED S-2 100.00 STACK/VENT OPERATING STATUS (CH E CK ONE)
Ol nactive O oismantled H EI GHT (FT.) DIAMETER (FT.) TEMPERATURE (F) V E LOCITY (F T./MIN.) F L OW RAT E (CU FT./MIN.)
LIST OTH E R PO I NTS SHAR I NG TH I S STACK/VENT 98.00 4.000 760.00 7 , 252.00 69,623.00 E M I SS I O N UNI T N O. SOURCE CLASSIF I CA T ION CO DE (SCC) S E G. NO.
FOR A N ON-C I RCULAR S T ACK: B-03 20200402 1 0 Vent D I AME TE R= (1.128A)'1/2 (A=CROSS SECT I ONAL AREA IN Sa FEET) STACK/VENT NO. STACK/VENT DESCRIPTION
% OF E MISSIONS RE L EAS E D S-3 100.00 STACK/VENT OPERAT I NG S T A T US (CHECK ONE)
O lnactive O oismantled HEIGHT (FT.) DIAM E T E R (FT.) TEMPERATURE (F) V EL OCITY (FT./MIN.)
FLOW RATE (CU FT./MIN.)
LIST OTHER POIN T S SHARING THIS STACK/VENT 98.00 4.000 760.00 7 , 252.00 69 , 623.00 EM I SS I ON UN IT N O. SOURCE CLASS I FICA T ION CO DE (SCC) S E G. N O.
FOR A NO N-C I RCU LA R STACK: B-04 20200402 1 0 Vent D I AMETER= (1.128A)'1/2 (A=CROSS SEC TI O N A L AREA IN Sa FEET) STACK/VENT NO. STACK/VENT DESCR I PTION % OF EM I SSIONS RELEAS E D S-4 100.00 STACK/VENT OP E RATING STATUS (CHECK ONE)
O lnactive O oismantled HEIGHT (FT.) DIAM E T E R (FT.) TEMPERATURE (F) V EL OCITY (FT./MIN.)
F L OW RATE (CU FT./MIN.)
LIST OTHER PO I NTS S H AR I NG TH I S STACK/VENT 19.00 2.000 780.00 2 , 864.00 6 , 300.00 MO 780-1435 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0S STACKNENT INFORMATION FACILITY NAME FIPS COUNTY NO. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. B-05 20200402 1 STACKNENT NO. STACKNENT DESCRIPTION S-5 PLANT NO. YEAR OF DATA 0026 2010 [8] Stack FOR A NON-CIRCULAR STACK: D Vent DIAMETER=
(1.128A)'1/2 (A=CROSS SECTIONAL AREA IN Sa FEET) % OF EMISSIONS RELEASED 100.00 STACKNENT OPERATING STATUS (CHECK ONE) [8]Ac tive Dlnacti ve D Dismantled HEIGHT (FT.) DIAMETER (FT.) TEMP ERA TURE (F) VELOCITY (FT./M IN.) FLOW RATE (CU FT./M IN.) LIST OTHER POINTS SHARING THIS STACKNENT 18.00 2.000 915.00 772.00 1,960.00 EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. [8] Stack FOR A NON-CIRCULAR STACK: B-06 20200402 1 D Vent DIAMETER=
(1.128A)'1/2 (A=CROSS SECTIONAL AREA IN sa FEET) STACKNENT NO. STACKNENT DESCRIPTION
% OF EMISSIONS RELEASED S-6 100.00 STACKNENT OPERATING STATUS (CHECK ONE) [8]Ac live Dlna ctive Oo ismantled HEIGHT (FT.) DIAMETER (FT.) TEMPERATURE (F) V ELOCITY (FT./MIN.) FLOW RATE (CU FT./MIN.)
LIST OTHER POINTS SHARING THIS STACKNENT 19.00 2.000 950.00 1,388.00 3,040.00 EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. [8] Stack FOR A NON-CIRCULAR STACK: B-07 20200402 1 D Vent DIAMETER = (1.128A)'1/2 (A=CROSS SECTIONAL AREA IN Sa FEET) STACKNENT NO. STACKNENT DESCRIPTION
% OF EMISSIONS RELEASED S-7 100.00 STACKNENT OPERATING STATUS (CH ECK ONE) [8]Act ive Dln active Ooi smantled HEIGHT (FT.) DIAMETER (FT.) TEMPERATURE (F) VELOCITY (FT./MIN.)
FLOW RATE (CU FT./MIN.)
LIST OTHER POINTS SHARING THIS STACKNENT 18.00 1.000 823.00 1,216.00 955.00 EMISSION UNIT NO. SOURCE CLASSIFICATION CODE (SCC) SEG. NO. [8] Stack FOR A NON-CIRCULAR STACK: B-12 20200402 1 D Vent DIAMETER=
(1.128A)'1/2 (A=CROSS SECTIONAL AREA IN sa FEET) STACKNENT NO. STACKNENT DESCRIPTION
% OF EMISSIONS RELEASED S-2 100.00 STACKNENT OPERATING STATUS (CH ECK ONE) [8]Acl ive Dlnac tive Ooi smantled HEIGHT (FT.) DIAMETER (FT.) TEMPERATURE (F) VELOCITY (F T./M IN.) FLOW RATE (CU FT./MIN.)
LIST OTHER POINTS SHARING THIS STACKNENT 98.00 4.000 760.00 7 , 252.00 69,623.00 MO 780-1435 (12-09)
MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 2.0S STACKNENT INFORMATION F AC ILI TY N A ME FIPS COU N TY N O. AMEREN MISSOURI 027 CALLAWAY NUCLEAR POWER PLANT E M I SS I O N UNIT N O. SOURC E CLASS I FICA TI ON CO DE (SCC) S E G. N O. B-13 20200402 1 STACKN ENT NO. S T ACKN E N T D E SC RIP T I ON S-3 P LANT NO. Y E A R O F D A T A 0026 2010 IRJ Stack FOR A N ON-C I RCU LA R STACK: 0 Vent D I AM ETE R= (1.128A)'1/2 (A=CROSS S E CT I O N A L AREA IN SQ FE E T) %O F E MISS I O N S R ELEA SED 100.00 S T ACKN ENT OP E RAT IN G S T ATUS (CHECK ONE) (8]Active O lnactive 0 D ismantled H EI GHT (FT.) D I AM E T E R (FT.) TE M PE RATUR E (F) V EL OCITY (F T./MIN.) FL OW RAT E (CU FT./M IN.) LI S T O T H E R P O I NTS SHARING THIS STACKN E NT 98.00 4.000 760.00 7 , 252.00 69 , 623.00 MO 780-1 4 35 (12-09)
FACILITY NAME MISSOURI DEPARTMENT OF NATURAL RESOURCES AIR POLLUTION CONTROL PROGRAM EMISSIONS INVENTORY QUESTIONNAIRE, OR EIQ FORM 3.0 EMISSIONS FEE CALCULATION FIPS COUNTY NO. PLANT NO. YEAR OF DATA AMEREN MISSOURI 027 0026 2010 CALLAWAY NUCLEAR POWER PLANT 1. Use one row to list the emissions from one emission unit. Sum the emissions in the page total box at the bottom of the column. EMISSION UNIT NO. If more than one page is needed, use the first row of the duplicated page to list the page totals from this page. Express figures in tons per year and round to two decimal places. sec AIR POLLUTANT PM10 FIL SOx NOx voc co LEAD HAPs PM2.5 FIL NH3 PM CON B-01 0.18 1.14 3.65 0.04 0.91 0.00 0.00 0.00 0.00 0.00 10200501 B-02 0.26 3.03 8.99 0.27 2.06 0.00 0.00 0.00 0.00 0.00 20200402 B-03 0.21 2.46 7.30 0.22 1.67 0.00 0.00 0.00 0.00 0.00 20200402 B-04 0.01 0.07 0.22 0.01 0.05 0.00 0.00 0.00 0.00 0.00 20200402 B-05 0.01 0.00 0.07 0.01 0.02 0.00 0.00 0.00 0.00 0.00 20200402 B-06 0.01 0.01 0.13 0.01 0.03 0.00 0.00 0.00 0.00 0.00 20200402 B-07 0.01 0.01 0.12 0.01 0.03 0.00 0.00 0.00 0.00 0.00 20200402 B-10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20200402 B-12 0.02 0.00 1.44 0.07 0.14 0.00 0.00 0.00 0.00 0.00 20200402 B-13 0.00 0.00 0.13 0.01 0.01 0.00 0.00 0.00 0.00 0.00 20200402 PAGE TOTALS 0.70 6.72 22.03 0.62 4.92 0.00 0.00 0.00 0.00 0.00 Note: Fill out the lower portion of this form one time only. 2. ACTUAL EMISSIONS (Use the sum of all page totals for each pollutant for actual emission figures below.) PM10 SOx NOx voc co LEAD HAPs PM2.5 NH3 PM CON Total TOTAL TOTAL 6.72 22.03 0.62 4.92 0.00 0.00 0.00 Included in 0.70 0.00 Total PM10 and PM2.5 \..opy the actual emissions from section 2 to the appropriate box(es) in the Total Plant Emissions section of Form 1.0 General Plant Information.
- 3. CHARGEABLE EMISSIONS (Maximum 4,000 Tons/Yr. cap per pollutant)
NO FEES NO FEES NO FEES PM CON is Total 0.70 6.72 22.03 0.62 FOR CO 0.00 0.00 FORPM2.5 FORNH3 included in PM10 and PM2.5 4. SUM OF CHARGEABLE EMISSIONS SUBJECT TO FEES Round chargeable emissions to the nearest whole ton. The minimum emission 30.00 TonsNr. onnage is one ton, and the maximum is 12,000 tons per year. 15* TOTAL ANNUAL EMISSIONS FEE Multiply the sum of chargeable emissions as calculated in section 4 by $40 and enter $ 1 , 200.00 his amount in section 5. The minimum fee is $40. ANNUAL EMISSIONS FEE REMITTED TO THE CITY OF KANSAS CITY OR ST. LOUIS COUNTY LOCAL AIR AGENCY HECK NUMBER r_HECK DATE rMOUNT REMITIED IN CALENDAR YEAR OF RECORD $0.00
$ 1 , 200.00 LLUTION CONTROL PROGRAM. F Facilities within local air program jurisdiction only need to include copies of Form 1.0 General Plant Information , 3.0 Emissions Fee Calculation and Form 4.0 Financial Cost Estimate with the emissions fee check. MO 780.1509 (12*09)