NL-07-1397, Vogtle, Unit 2, Inservice Inspection Summary Report for Activities Performed During Spring 2007 Maintenance/Refueling Outage: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[NL-07-1397, Actions Taken in Response to Generic Letter 2006-03, Potentially Nonconforming Hemyc and MT Fire Barrier Configurations]]
| number = ML072040084
| issue date = 07/19/2007
| title = Vogtle, Unit 2, Inservice Inspection Summary Report for Activities Performed During Spring 2007 Maintenance/Refueling Outage
| author name = George B J
| author affiliation = Southern Nuclear Operating Co, Inc
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000425
| license number =
| contact person =
| case reference number = NL-07-1397
| document type = Letter type:NL, Report, Miscellaneous
| page count = 91
}}
 
=Text=
{{#Wiki_filter:Southern Nuclear Operating Company, Inc.Post Office Box 1295 Birmingham, Alabama 35201-1295 Tel 205.992.5000 SOUTHERNEh COMPANY July 19, 2007 Energy to Serve Your World'Docket No.: 50-425 NL-07-1397 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Vogtle Electric Generating Plant Unit 2 Inservice Inspection Summary Report Ladies and Gentlemen:
Southern Nuclear Operating Company (SNC) submits herewith the Vogtle Electric Generating Plant Unit 2, Interval 2, Period 3, Outage 2 Inservice Inspection Summary Report (Enclosure).
This report describes and summarizes the inservice inspection activities performed during the spring 2007 maintenance/refueling outage. Paragraph IWA-6230 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section Xl, 1989 Edition requires submittal of the enclosed report.The supporting inservice inspection documentation, e.g., examination plans and schedules, examination results and reports, examination methods and procedures, evaluation results, and corrective action and repairs, is available for review upon request at Vogtle Electric Generating Plant.This letter contains no NRC commitments.
If you have any questions, please advise.Sincerely, B. J. Geo ge Manager, Nuclear Licensing BJG/DRG/daj
 
==Enclosure:==
 
Vogtle Electric Generating Plant -Unit 2 Inservice Inspection Summary Report Refueling Outage (2R12)
U. S. Nuclear Regulatory Commission NL-07-0122 Page 2 cc: Southern Nuclear Operatingq Company Mr. J. T. Gasser, Executive Vice President Mr. T. E. Tynan, Vice President
-Vogtle Mr. D. H. Jones, Vice President
-Engineering RType: CVC7000 U. S. Nuclear Regulatory Commission Dr. W. D. Travers, Regional Administrator Mr. B. K. Singal, NRR Project Manager -Vogtle Mr. G. J. McCoy, Senior Resident Inspector
-Vogtle Vogtle Electric Generating Plant Unit 2 Inservice Inspection Summary Report Enclosure Vogtle Electric Generating Plant -Unit 2 Inservice Inspection Summary Report. Refueling Outage (2R12)
VOGTLE ELECTRIC GENERATING PLANT UNIT 2 TWELFTH MAINTENANCE/REFUELING OUTAGE (2R12)OWNER'S REPORT FOR INSERVICE INSPECTIONS OWNER'S REPORT FOR INSERVICE INSPECTIONS for the TWELFTH MAINTENANCE/REFUELING OUTAGE of VOGTLE ELECTRIC GENERATING PLANT, UNIT 2 (7821 River Road, P. 0. Box 1600, Waynesboro, Georgia 30830)COMMERCIAL OPERATION DATE: May 20, 1989 DOCUMENT COMPLETION DATE: July 2007 Prepared by SOUTHERN NUCLEAR OPERATING COMPANY (40 Inverness Center Parkway, P. 0. Box 1295, Birmingham, Alabama 35201)as LICENSEE AND OPERATING AGENT for GEORGIA POWER COMPANY (241 Ralph McGill Boulevard, N.E., P. 0. Box 4545, Atlanta, Georgia 30308-3374) as OWNER TABLE OF CONTENTS Page Introduction 1-1 ASME Form NIS-1 with Abstract -ASME Class I and 2 2-1 Class MC Containment Examinations and Tests (IWE) 3-1 Examination Summary Listings Class I and 2 Weld and Support Examinations 4-1 System Pressure Tests 5-1 Reportable Indication Summary 6-1 Owner's Reports for Repairs or Replacements (Form NIS-2) 7-1 i LIST OF ABBREVIATIONS ACC Acceptable AD Anchor/Darling AFW Auxiliary Feedwater System Al GPC Action Item (followed by unique no. denoting Action Item number)ANII Authorized Nuclear Inservice Inspector ASME American Society of Mechanical Engineers ASNT American Society for Nondestructive Testing ASTM American Society for Testing and Materials BC Branch Connection CCSS Centrifugally Cast Stainless Steel CCW Component Cooling Water CE Combustion Engineering CH Closure Head CR Condition Report CS Containment Spray CVCS Chemical and Volume Control System DS Downstream ET Eddy Current Examination EVAL Evaluation FAC Flow-Accelerated Corrosion (may also be referred to as "erosion/corrosion")
FB Flange Bolting FNF FAC Notification Report FW Feedwater System FSAR VEGP Final Safety Analysis Report (includes updates thereto)GEO Geometric Indications GPC Georgia Power Company HHSI High Head Safety Injection HL Hanger Lug HX Heat Exchanger HYD Hydraulic Snubber IEN NRC Information Notice (may also be shown as "IN" followed by-unique no. denoting notice number)IND Indication INF Indication Notification Form ISI Inservice Inspection IST Inservice Testing ITS VEGP Improved Technical Specification ID Inside Diameter IR Inside Radius LB Large Bore LD Longitudinal Seam Weld Extending Downstream LD-I Longitudinal Seam Weld Downstream Inside Radius of Elbow LD-O Longitudinal Seam Weld Downstream Outside Radius of Elbow LMT Lambert, MacGill and Thomas LU Longitudinal Seam Weld Extending Upstream LU-I Longitudinal Seam Weld Upstream Inside Radius of Elbow LU-O Longitudinal Seam Weld Upstream Outside Radius of Elbow MECH Mechanical Snubber MS Main Steam System MT Magnetic Particle Examination NCI Nonconformance Item NDE Nondestructive Examination ii LIST OF ABBREVIATIONS
-(continued)
NI No Indication NRC United States Nuclear Regulatory Commission NRC-B NRC Bulletin (followed by unique no. denoting Bulletin number)NRI No Recordable Indication NSCW Nuclear Service Cooling Water System OR Outside Radius PL Pipe Lug PM Paul-Munroe ENERTECH PR Pipe Restraint PROF Profile PS Pipe Support PSA Pacific Scientific PSI Preservice Inspection PT Liquid Penetrant Examination RCS Reactor Coolant System RCP Reactor Coolant Pump RHR Residual Heat Removal System RI Recordable Indication RLW Refracted Longitudinal Wave RL Restraint Lug RPV Reactor Pressure Vessel RR Relief Request (followed by unique no. denoting relief request number)RWST Refueling Water Storage Tank SAT Satisfactory Examination Results SB Small Bore SCS Southern Company Services SI Safety Injection System SNC Southern Nuclear Operating Company SUP Supplemental Data T&C Thickness and Contour TDAFW Turbine Driven Auxiliary Feedwater (Pump)UNSAT Unsatisfactory Examination Results US Upstream UT Ultrasonic Examination VEGP Vogtle Electric Generating Plant (common unless followed by "-1" or "-2" to designate a specific plant unit)VT Visual Examination W Westinghouse iii INTRODUCTION Thisreport documents the examinations and tests performed at Vogtle Electric Generating Plant, Unit 2 (VEGP-2)between October 14, 2005 (date of last examination performed during the eleventh (I1 th) maintenance/refueling outage, 2R1 1) and April 20, 2007 (date of last examination performed during the twelfth maintenance/refueling outage, 2R12) to meet the requirements of Article IWA-6000 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI, 1989 Edition (Code).This report also addresses Code-applicable repairs and/or replacements, which were documented since the last maintenance/refueling outage at VEGP-2 through the completion of the twelfth maintenance/refueling outage in Spring, 2007. The Owner's Reports for Repairs and Replacements (Form NIS-2) are included herein.This report does not include a summary of the Steam Generator Tube Inspections which are required per VEGP Technical Specification 5.6.10. This will be provided in a separate report one hundred eighty (180) days after the initial entry into MODE 4 following completion of an inspection performed in accordance with Technical Specification 5.5.9. The applicable ASME Code requirements were met and the separate report will provide the details for these examinations.
1-1 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules 1. Owner: Georgia Power Company, 241 Ralph McGill Blvd., N. E.P. 0. Box 4545, Atlanta, Georgia 30308-3374
: 2. Plant: Vogtle Electric Generating Plant, 7821 River Road P. 0. Box 1600, Waynesboro, Georgia 30830 3. Plant Unit: Two 4. Owner Certification of Authorization:
N/A 5. Commercial Service Date: 05-20-1989
: 6. National Board Number for Unit: N/A 7. Components Inspected:
Component or Manufacturer or Manufacturer or Installer State or.Province National Board Appurtenance Installer and Serial Number Number Number Address Reactor Combustion Eng. 7372 N/A 22004 Pressure Vessel Inc., Chattanooga, TN Residual Heat Joseph Oat Corp., 2322-2D N/A 1051 Removal Heat Camden, NJ Exchanger, Train "B" Selected Piping, Pullman Power System Numbers 1201, 1204, N/A N/A Components, Products, 1205, 1208, 1301, & 1305.and Supports Williamsport, PA I 2-1 FORM NIS- I (Back)8. Examination Dates: October 14, 2005 to April 20, 2007 9. Inspection Period Identification:
Third Period 10. Inspection Interval Identification:
Second Inspection Interval 11. Applicable Edition of Section XI 1989 Addenda None 12. Date/Revision of Inspection Plan: April 7. 2007 / Revision 9 13. Abstract of Examinations and Tests. Include a list of examinations and tests lnd a statement concerning status of work required for the Inspection Plan. (See Abstract and Examination Summary Listings)14. Abstract of Results of Examinations and Tests. (See Abstract)15. Abstract of Corrective Measures. (See Abstract)We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XI.Certificate of Authorization No. (if applicable)
N/A Expiration Date N/A Date: 11A1. 20 0-1 Signed: Southern Nuclear Operating By: L .i/tJ..Company, Inc. for Georgia Power Company Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Georgia and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut of Hartford, CT have inspected the components described in this Owner's Report during the period October 14, 2005 to April 20, 2007. and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commission:
GA ?71'(&* 'n nspec~r's Signature National Board, State, Province, and Endorsements Date:- JbL'( 4r"- I 20_002 MW- 7//(,/&-7 2-2 ABSTRACT -ASME CLASS 1 AND 2 Introduction/Status The ASME Boiler and Pressure Vessel Code, Section XI, 1989 Edition (Code), is the applicable code for conducting inservice inspection activities during.the second ten-year inspection interýal at VEGP-2. Examinations and tests required by the Code are scheduled in accordance with "Inspection Program B" as defined in Code paragraphs IWB-2412 and IWC-2412.
This "Owner's Report for Inservice Inspection" is for those third inspection period examinations and tests which were performed between October 14, 2005 (date of last examination performed during the eleventh maintenance/refueling outage, 2R1 1) and April 20, 2007 (date of last examination performed during the twelfth maintenance/refueling outage, 2R12).Risk Informed Program was approved by the NRC by letter dated September 30, 2003 and implemented during the VEGP 2R12 refueling outage (ASME Class 1 and Class 2 piping only).By Federal Register Notice 64 FR 51370 dated September 22, 1999, 10 CFR 50.55a(g)(6)(ii)(C), Implementation of Appendix VIII to Section XI, was incorporated into the rule to expedite implementation of Appendix VIII. The specific Supplements of Appendix VIII to Section XI, ASME Boiler and Pressure Vessel Code, 1995 Edition with the 1996 Addenda were implemented prior to the 2R12 maintenance/refueling outage as required.In addition to the summary of inservice inspection activities, this report addresses Code-applicable repairs and replacements documented at VEGP-2 since 2R1 1 through the end of 2R12. Class 1 and Class 2 Owner's Reports for Repairs or Replacements (Form NIS-2) are provided herein.It should be noted that Authorized Nuclear Inservice Inspector (ANII) inspection services were provided for those examinations and tests required by the Code. ASME Section XI examinations and tests are itemized in the applicable sections by reference to Examination Category.
Examinations which do not meet the Code-required coverage either reference request(s) for relief or indicate that additional relief is required.Selected examinations were not performed during the 2R12 outage. These examinations have been deferred until some other time which satisfies the requirement to perform the Second ISI interval examinations within the one-year extension past the end of the interval (May 30, 2007).Class 1 Examinations Selected Class 1 components were examined by Southern Nuclear Operating Company (SNC) personnel utilizing ultrasonic testing (UT), magnetic particle testing (MT), liquid penetrant (PT), and visual testing (VT) methods, as applicable.
Specific components and examination areas are itemized in the applicable portions of this document.* During the scope of VEGP-2 examinations conducted, no Class 1 components were observed to have either reportable UT, PT or MT reportable indications.
In addition to components already identified in current requests for relief, two (2) reactor pressure vessel welds and two (2) piping welds had limited volumetric coverage during UT examinations because of physical limitations due to the geometric configuration of the welded areas. In addition, two (2) reactor pressure vessel integrally welded attachments had limited surface coverage because of physical limitations due to the geometric configuration of the welded areas.More than ninety percent (90%) of the required volume must be examined as addressed in ASME Section XI Code Case N-460 for adequate ASME Section XI Code-required examination coverage to be attained.
As noted herein, the subject code case has been approved by the NRC for use as documented in NRC Regulatory Guide 1.147. It is impractical to achieve the ASME Section XI Code-required coverage due to the geometric configuration of the welded areas. These limited examinations will be submitted to the NRC through the relief request process as allowed by 10 CFR 50.55a.2-3 Class 1 Pressure Test Table IWB-2500-1, Examination Category B-P, of ASME Section XI requires the performance of a system leakage test (IWB-5221) each maintenance/refueling outage. This system leakage test (LT-1) was performed prior to plant startup following the refueling outage. These visual examinations revealed minor leakage and boron residue at mechanical connections.
These leakage conditions were documented.
in the Corrective Action Program.Table IWB-2500-1, Examination Category B-P, of ASME Section XI also requires the performance of a system hydrostatic test (IWB-5222) once at, .or near the end of, each inspection interval.
This test is identified as the Class 1 hydrostatic test (HT-1) and it extends to the Class 1 pressure boundary extremity (i.e., second isolation valve) and also includes selected adjacent Class 2 components which are typically isolated from the Class 1 boundary by check valves. As an alternative to ASME Section XI requirements, Code Case N-498-4, which was conditionally accepted for use in Revision 14 of Regulatory Guide 1. 147 dated August 2005, was used. Code Case N-498-4 deleted the elevated pressure requirement for the hydrostatic test and reduced the holding time requirement but retained the, requirement to extend the boundary subject to test pressurization to include each of the Class 1 pressure-retaining components.
To assure that all Class I pressure retaining components and selected adjacent Class 2 pressure retaining components are pressurized requires, for some isolated boundaries, that valves be aligned to positions other than their normal alignment and, for other isolated boundaries, the use of a hydrostatic test pump. The visual*examinations performed revealed minor leakage and boron residue at mechanical connections.
These leakage conditions were documented in the Corrective Action Program.ASME Section XI, Subparagraph IWA-5242(a) requires removal of insulation from pressure-retaining bolted connections for VT-2 examination during system pressure testing for systems borated for the purposes of controlling reactivity:
ASME Section XI Code Cases N-533-1 and N-616 were utilized during the refueling outage. These Code Cases were approved for use in Revision 13 of Regulatory Guide 1.147 dated June 2003. Case N-533-1 allows insulation to be removed while the connections are'at atmospheric or static pressures.
With the insulation removed, a direct visual examination is performed to detect previously occurring leakage through the presence of boric acid crystals.
Case N-616 allows the VT-2 examination to occur without insulation removal provided the bolting material is resistant to boric acid degradation.
The test boundary of the system leakage test includes both Class 1 and Class 2 components.
The frequency for removal of insulation and direct visual examination for Class 1 pressure-retaining bolted connections is once each refueling outage (refer to Table IWB-2500-1, Examination Category B-P) and as such those activities occurred during the refueling outage. The Class 2 components comprise part of the reactor coolant pressure boundary but are.not required to be classified as Class 1 per 10 CFR 50.55a(c)(2).
The frequency for removal of insulation and direct visual examination for Class 2 pressure-retaining bolted connections is' once each inspection period (refer to 'Table IWC-2500-1, Examination Category C-H). Those applicable Class 2 activities were completed also during the refueling outage.Class 2 Examinations Selected Class 2 Piping welds were examined utilizing UT. Specific components and examination areas are itemized in the applicable portions of this report document.During the scope of VEGP-2 examinations conducted, Class 2 components were observed with reportable indications (two PT indications and one UT indication).'
These indications met the acceptance standards of Section XI, 1989 Edition.2-4 The two RHR heat exchanger nozzle welds had limited coverage due to the geometric configuration'of the welded areas. More than ninety percent (90%) of the required volume must be examined as addressed in ASME Section XI Code Case N-460 for adequate ASME Section XI Code-required examination coverage to be attained.
As noted herein, the subject code case has been approved by the NRC for use as documented in NRC Regulatory Guide 1.147.It is impractical to achieve the ASME Section XI Code-required coverage due to the geometric configuration of the welded areas. These limited examinations will be submitted to the NRC through the relief request process as allowed by 10 CFR 50.55a.Class 2 Pressure Tests Table IWC-2500-1, Examination Category C-H, of ASME Section XI requires system pressure testing each inspection period. The specific system pressure tests performed are itemized in the "Pressure Tests" portion of this report document.
The visual examinations performed during these system pressure tests found only minor leakage or*residue at mechanical joints such as valve stem packing and at flanged connections.
These leakage conditions were documented in the Corrective Action Program.ASME Section XI, Subparagraph IWA-5242(a) requires removal of insulation from pressure-retaining bolted connections for VT-2 examination during system pressure testing for systems borated forthe purposes of controlling reactivity.
ASME Section XI Code Cases N-533-1 and N-616 were utilized.
These Code Cases were approved for use in Revision 13 of Regulatory Guide 1.147 dated June 2003. Case N-533-1 allows insulation to be removed while the.connections are at atmospheric or static pressures.
With the insulation removed, a direct visual examination is performed to detect previously occurring leakage through the presence of boric acid crystals.
Case N-616 allows the VT-2 examination to occur without insulation removal provided the bolting material is resistant to boric acid degradation.
Class 1 and 2 Component Supports No Class 1 or 2 Component Supports were examined this outage.2-5 Class MC Containment Examinations and Tests (IWE)During the VEGP-2 Spring 2007 maintenance/refueling outage, examinations of Class MC pressure retaining components with their integral attachments, and metallic shell and penetration liners of Class CC pressure retaining components with their integral attachments were performed in response to the NRC rulemaking to 10 CFR 50.55a, which invoked the requirements of Subsections IWE of the 1992 Edition of ASME Section XI with 1992 Addenda. The examinations were performed using VEGP procedure 85053-C,"Visual Examinations for ASME XI Subsection IWE and IWL and General Visual Examinations." Per procedure 85053-C, the VEGP-2 components were examined for deviations or departures from the normal or common order, form, or rule with evidence of degradation that may affect either the containment structural integrity or leak tightness.
Personnel performing the examinations were qualified in accordance with VEGP procedure 85003-C, Revision 25.2, "Qualification and Certification of Nondestructive Examination and Testing Personnel." Optical aids such as flashlights and binoculars were used when performing the examinations that included both direct and indirect, i.e., remote and visual examination methods.Category E-A, Containment Surfaces A VT-3 visual examination of 100% of the accessible portions of the containment surfaces was performed.
Thirty one anomalies were identified on Anomaly Data sheets and documented under Quality Control Inspection Report (IR) #31705. All thirty one anomalies were dispositioned under CR# 2007104367 as"hardware not affected" based on their cosmetic nature that does not affect the leak tightness of the pressure retaining containment surfaces.
SCS letters SG-18218, dated February 28, 2001, and SG-17755, dated September 19, 2000, provide the Owners acceptance criteria used. to disposition the recorded anomalies.
Category E-B, Pressure-Retaining Welds The rulemaking contains a modification that makes examinations of Subsection IWE, Category E-B optional.
SNC has chosen to not examine category E-B welds at VEGP.Category E-C, Containment Surfaces Requiring Augmented Examination Identified surface areas likely to experience accelerated degradation and aging require the performance of augmented examinations as defined in Examination Category E-C. There are no existing areas in VEGP-2 requiring Category E-C examination.
Category E-D; Seals, Gaskets, and Moisture Barriers A VT-3 of 100% of the moisture barrier was performed and no anomalies were found as documented on IR#31704. SNC has chosen to implement Request for Relief (RR-E-1) to allow leak tightness of seals and gaskets to be verified by 10 CFR 50, Appendix J Type B testing (LLRT). The NRC approved SNC's use of RR-E-1 in its June 16, 2000, letter to SNC. The Type B test results, along with the Type C test results, are available at the plant site for review upon request in accordance with 10 CFR 50 Appendix J Option B.3-1 Category E-F, Pressure-Retaining Dissimilar Metal Welds The rulemaking contains a modification that makes examinations of Subsection IWE, Category E-F optional.
SNC has chosen to not examine category E-F welds at VEGP.Category E-G, Pressure-Retaining Bolting The following VT-i examinations of the accessible containment boundary pressure-retaining bolting necessary to achieve the 100% required during the interval were performed with no anomalies found as documented on IR #31542.21818H3P01 21818H3P02 21818H3P03 21818H3P04 21818H3P05 21818H3P06 21818H3P07 21818H3P08 21818H3Pl I 21818H3P13 21818H3P17 21818H3P18 21818H3P19 21818H3P20 21818H3P21 21818H3P22 21818H3P23 21818H3P24 21818H3P25 21818H3P26 21818H3P27 21818H3P28 21818H3P34 21818H3P35 21818H3P36 21818H3P37 21818H3P38 21818H3P39 21818H3P40 21818H3P41 21818H3P42 21818H3P43 21818H3P44 21818H3P50 21818H3P51 21818H3P52 21818H3P55 21818H3P59 21818H3P60 21818H3P61 21818H3P62 21818H3P63 21818H3P64 21818H3P65 21818H3P66 21818H3P67 21818H3P68 21818H3P69 21818H3P70 21818H3P71 21818H3P72 22101R2014 22101 R2015 3-2 Exam Category R-A R-A R-A R-A R-A R-A R-A R-A B-G-1 B-N-3 B-N-1 B-N-1 B-D B-D B-D Component ID 21201-001-1-RI 21201-002-1-RI 21201-003-1 -RI 21201-004-1 -RI 21201-009-9-RI 21201-010-7-RI 21201-011-8-RI 21201-012-9-RI 21201-V6-001-B01 THRU B54 21201-V6-001-CSS-01 21201-V6-001-101 21201-V6-001-102 21201-V6-001-IR01 21201-V6-001-1R02 21201-V6-001-1R03 VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Component Description Proce 29" SAFE END TO PIPE VENDC 29" SAFE END TO PIPE VENDC 29" SAFE END TO PIPE VENDC 29" SAFE END TO PIPE VENDC 27.5" ELBOW TO SAFE END VENDC 27.5" ELBOW TO SAFE END VENDC 27.5" ELBOW TO SAFE END VENDC 27.5" ELBOW TO SAFE END VENDC CLOSURE HEAD STUDS NMP-ES-CORE SUPPORT STRUCTURE VENDC VESSEL INTERIOR VENDC VESSEL CLOSURE HEAD INTERIOR NMP-ES-(FSAR 5.3.3.7)OUTLET NOZZLE N1 INNER RADIUS VENDC INLET NOZZLE N2 INNER RADIUS VENDC INLET NOZZLE N3 INNER RADIUS VENDC dure)R-UT)R-UT)R-UT)R-UT)R-UT)R-UT)R-UT)R-UT 024-504)R-VT)R-VT 024-203)R-VT)R-VT)R-VT Report No Results NI NI NI NI NI NI NI NI NRI Sat Sat Accept Sat Sat Sat Comments Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Augmented Exam.Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
S07V2U065 S07V2V005 Page 4-1
.Exam Category B-D B-D B-D B-D B-D B-G-1 B-G-1 B-G-1 B-A Component ID 21201-V6-001-1R04 21201 -V6-001 -IR05 21201-V6-001-1R06 21201-V6-001-1R07 21201-V6-001-1R08 21201-V6-001-L01 THRU L54 21201-V6-001-NO1 THRU N54 21201-V6-001-SO1 THRU S54 21201 -V6-001-W03 (0-180)VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Component Description Proce OUTLET NOZZLE N4 INNER RADIUS VEND(OUTLET NOZZLE N5 INNER RADIUS VEND(INLET NOZZLE N6 INNER RADIUS VEND(INLET NOZZLE N7 INNER RADIUS VEND(OUTLET NOZZLE N8 INNER RADIUS VEND(THREADS IN FLANGE VEND(CLOSURE HEAD NUTS NMP-ES.CLOSURE WASHERS NMP-ES.0 TO 180 DEGREE VESSEL FLANGE TO VEND(SHELL WELD.dure JR-VT OR-VT JR-VT JR-VT JR-VT JR-UT-024-201-024-201 OR-UT Report No Results Sat Sat Sat Sat Sat Sat Sat Sat Comments Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
S07V2VO12 S07V2VO13 B-A 21201-V6-001-W03 (180-360)B-A 21201-V6-001-W04 B-A 21201-V6-001-W05 B-A 21201 -V6-001 -W06 180 TO 360 DEGREE VESSEL FLANGE TO SHELL WELD UPPER SHELL TO INTERMEDIATE SHELL WELD INTERMEDIATE SHELL TO LOWER SHELL WELD LOWER SHELL TO BOTTOM HEAD TORUS WELD VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT RI Performed by Westinghouse.
Acceptable per IWB-3510-1.RI Performed by Westinghouse.
Acceptable per IWB-3510-1.RI Performed by Westinghouse.
Acceptable per IWB-3510-1.NI Performed by Westinghouse.
NI 78.43% Coverage.Performed by Westinghouse.
Page 4-2 VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Exam Category Component ID Component Description Procedure Report No Results Comments B-A 21201-V6-001 -W07 B-A 21201-V6-001-W12 B-A 21201-V6-001-W13 B-A 21201-V6-001-W14 B-A 21201-V6-001-W15 B-A 21201-V6-001-W16 B-A 21201-V6-001-W17 B-A 21201-V6-001-W18 B-A 21201-V6-001-W19 B-A 21201-V6-001 -W20 B-A 21201-V6-001-W21 BOTTOM HEAD TORUS TO BOTTOM HEAD DOME WELD UPPER SHELL LONGITUDINAL WELD AT 42 DEGREES UPPER SHELL LONGITUDINAL WELD AT 162 DEGREES UPPER SHELL LONGITUDINAL WELD AT 282 DEGREES INTERMEDIATE SHELL LONGITUDINAL WELD AT 0 DEGREES INTERMEDIATE SHELL LONGITUDINAL WELD AT 120 DEGREE INTERMEDIATE SHELL LONGITUDINAL WELD AT 240 DEGREE LOWER SHELL LONGITUDINAL WELD AT 90 DEGREES LOWER SHELL LONGITUDINAL WELD AT 210 DEGREES LOWER SHELL LONGITUDINAL WELD AT 330 DEGREES BOTTOM HEAD TORUS MERIDIONAL WELD AT 0 DEGREES VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT NI 74.15% Coverage.Performed by Westinghouse.
RI Performed by Westinghouse.
Acceptable per IWB-3510-1.RI Performed by Westinghouse.
Acceptable per IWB-3510-1.NI Performed by Westinghouse.
NI Performed by Westinghouse.
NI Performed by Westinghouse.
RI Performed by Westinghouse.
Acceptable per IWB-3510-1.RI Performed by Westinghouse.
Acceptable per IWB-3510-1.RI Performed by Westinghouse.
Acceptable per IWB-3510-1.RI Performed by Westinghouse.
Acceptable per IWB-3510-1.NI Performed by Westinghouse.
VENDOR-UT VENDOR-UT Page 4-3 VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Exam Category Component ID Component Description Procedure Report No Results Comments B-A B-A B-A B-D B-D B-D B-D B-D B-D B-D B-D R-A 21201-V6-001-W22 21201-V6-001-W23 21201-V6-001-W24 21201-V6-001-W25 21201 -V6-001-W26 21201-V6-001 -W27 21201-V6-001-W28 21201-V6-001-W29 21201-V6-001-W30 21201-V6-001 -W31 21201 -V6-001 -W32 21201-V6-001-W33-RI BOTTOM HEAD TORUS MERIDIONAL WELD AT 90 DEGREES BOTTOM HEAD TORUS MERIDIONAL WELD AT 180 DEGREES BOTTOM HEAD TORUS MERIDIONAL WELD AT 270 DEGREES VESSEL TO OUTLET NOZZLE N1 WELD VESSEL TO INLET NOZZLE N2 WELD VESSEL TO INLET NOZZLE N3 WELD VESSEL TO OUTLET NOZZLE N4 WELD VESSEL TO OUTLET NOZZLE N5 WELD VESSEL TO INLET NOZZLE N6 WELD VESSEL TO INLET NOZZLE N7 WELD VESSEL TO OUTLET NOZZLE N8 WELD OUTLET NOZZLE NI TO SAFE END WELD INLET NOZZLE N2 TO SAFE END WELD*VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT NI NI NI NI RI VENDOR-UT VENDOR-UT NIl RI Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Acceptable per IWB-3512-1.Performed by Westinghouse.
Performed by Westinghouse.
Acceptable per IWB-3512-1.Performed by-Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Acceptable per IWB-3512-1.Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
VENDOR-UT VENDOR-UT VENDOR-UT N1 NI RI VENDOR-UT VENDOR-UT VENDOR-UT NI NI NI R-A 21201-V6-001-W34-RI Page 4 VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report.Interval 2, Period 3, 2VR12 Exam Category Component ID Component Description Procedure Report No Results Comments R-A R-A R-A R-A R-A R-A B-N-2 B-N-2 B-N-2 B-N-2 B-N-2 B-N-2 B-H B-H B-A 21201-V6-001-W35-RI 21201-V6-001 -W36-RI 21201-V6-001-W37-RI 21201-V6-001-W38-RI 21201-V6-001 -W39-RI 21201 -V6-001-W40-RI 21201-V6-001-W41 21201-V6-001 -W42 21201-V6-001-W43 21201-V6-001 -W44 21201-V6-001-W45 21201-V6-001-W46 21201-V6-001 -W204 21201-V6-001-W206 21201-V6-001-W207 INLET NOZZLE N3 TO SAFE END WELD OUTLET NOZZLE N4 TO SAFE END WELD OUTLET NOZZLE N5 TO SAFE END WELD INLET NOZZLE N6 TO SAFE END WELD INLET NOZZLE N7 TO SAFE END WELD OUTLET NOZZLE N8 TO SAFE END WELD CORE SUPPORT LUG AT 0 DEGREES CORE SUPPORT LUG AT 60 DEGREES CORE SUPPORT LUG AT 120 DEGREES CORE SUPPORT LUG AT 180 DEGREES CORE SUPPORT LUG AT 240 DEGREES CORE SUPPORT LUG AT 300 DEGREES LIFTING LUG AT 0 DEGREES LIFTING LUG AT 240 DEGREES NOZZLE DROP-OUT TO SHELL WELD VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-UT VENDOR-VT VENDOR-VT VENDOR-VT VENDOR-VT VENDOR-VT VENDOR-VT NMP-ES-024-401 NMP-ES-024-401 VENDOR-UT NI NI NI NI NI NI Sat Sat Sat Sat Sat Sat NRI NRI NI Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
Performed by Westinghouse.
59.2% Code Coverage 59.2% Code Coverage Performed by Westinghouse.
S07V2M001 S07V2M002 Page 4-5 VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Component Description Procedure Report No Results Exam Cxat r Component ID Category Comments B-A R-A 21201 -V6-001-W208 21204-023-15R-RI R-A 21204-023-16R-RI C-B 21205-E6-002-W04 C-B 21205-E6-002-W05 R-A 21208-005-CVl 10 NOZZLE DROP OUT TO SHELL WELD 6" PIPE TO VALVE 6" VALVE TO PIPE (Al 87-0131)14" OUTLET NOZZLE TO TUBE SIDE SHELL WELD 14" INLET NOZZLE TO TUBE SIDE SHELL WELD 3" PIPE DS (FO-0200)3" PIPE DS (FO-0201)3" PIPE DS (FO-0202)3" PIPE DS (FO-0202 SCAN)VENDOR-UT NMP-ES-024-501 NMP-ES-024-501 NMP-ES-024-301 NMP-ES-024-501 NMP-ES-024-301 NMP-ES-024-501 NMP-ES-024-510 S07V2U087 S07V2U088 S07V2U089 S07V2U090 S07V2P001 S07V2U003 S07V2U004 S07V2P002 S07V2U001 S07V2U002 S07V2U001 FAC S07V2U002 FAC S07V2U003 FAC S07V2U128 FAC NRI NRI NRI NRI RI NRI NRI RI NRI RI Westinghouse.
PSI Examination.
35%Code Coverage PSI Examination.
35%Code Coverage Acceptable per IWB-3514-2.41.5% Code Coverage Acceptable per IWB-3514-2 41.5% Code Coverage See INF 107V21001 Acceptable per IWB-3514-2 See FAC Report See FAC Report See FAC Report See FAC Report NI Performed by Page 4-6 VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Component Description Proce PENETRATION TO 28" PIPE (TS 5.5.16) NMP-ES-Exam Component ID Category R-A 21301-002-1-RI R-A 21301-002-2-RI R-A 21301-002-3-RI R-A 21301-002-4-RI R-A 21301-002-10-RI R-A 21301-003-1-RI R-A 21301-003-2-RI dure-024-502 28" PIPE TO PIPE (TS 5.5.16)28" PIPE TO 29 1/2" PIPE (TS 5.5.16)6" OUTLET TO FLANGE 29 1/2" PIPE TO VALVE (TS 5.5.16)PENETRATION TO 28" PIPE (TS 5.5.16)28" PIPE TO PIPE (TS 5.5.16)NMP-ES-024-502 NMP-ES-024-502 NMP-ES-024-502 NMP-ES-024-502 NMP-ES-024-502 NMP-ES-024-502 Report No S07V2U007 S07V2U008 S07V2U009 S07V2UO10 S07V2U011 S07V2Ul012 S07V2UO13 S07V2U014 S07V2U005 S07V2U006 S07V2UO15 S07V2UO16 S07V2U035 S07V2U036 S07V2UO019 Results NRI NRI NRI RI NRI NRI NRI NRI NRI NRI NRI RI NRI NRI NRI Comments GEOMETRY GEOMETRY (Continued on next page.)Page 4-7 Exam Category Component ID R-A 21301-003-2-RI R-A 21301-003-3-RI R-A 21301-003-9-RI R-A 21301-003-10-RI R-A 21301-014-3-RI R-A 21301-015-3-RI R-A 21305-062-10-RI VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Component Description Proce 28" PIPE TO PIPE (TS 5.5.16) NMP-ES-28" PIPE TO 29 1/2" PIPE (TS 5.5.16) NMP-ES-dure 024-502 024-502 6" OUTLET, TO FLANGE 29 1/2" PIPE TO VALVE (TS 5.5.16)8" REDUCER TO PIPE 8" REDUCER TO PIPE 16" VALVE TO PIPE (TS 5.5.16)NMP-ES-024-502 NMP-ES-024-502 NMP-ES-024-502 NMP-ES-024-502 NMP-ES-024-502 Report No S07V2U020 S07V2U029 S07V2U030 S07V2U031 S07V2U032 S07V2U039 S07V2U040 S07V2U033 S07V2U034 S07V2U021 S07V2U022 S07V2U056 S07V2U057 S07V2U078 S07V2U079 Results NRI NRI NRI RI RI NRI NRI NRI RI RI NRI NRI RI NRI RI Comments GEOMETRY GEOMETRY GEOMETRY GEOMETRY GEOMETRY GEOMETRY Page 4-8 VEGP Unit 2 Twelfth Refueling Outage Inservice Inspection Report Interval 2, Period 3, 2VR12 Component Description Proce 16" PIPE TO PENETRATION (TS 5.5.16) NMP-ES-Exam Category Component ID R-A 21305-062-1 1-RI dure Report No-024-502 S07V2U080 Results NRI Comments S07V2U081 RI GEOMETRY R-A 21305-064-8-RI 16" VALVE TO PIPE (TS 5.5.16)NMP-ES-024-502 S07V2U082 NRI S07V2U083 RI GEOMETRY R-A 21305-064-9-RI 16" PIPE TO PENETRATION (TS 5.5.16)NMP-ES-024-502 S07V2U063 NRI S07V2U064 RI GEOMETRY Page 4-9 SYSTEM PRESSURE TESTS The following pressure tests on Class 1 and Class 2 components were included in the scope of the maintenance/refueling outage. These pressure tests included system functional tests, system hydrostatic tests, system inservice tests, and system leakage tests. It should be noted that the hydrostatic tests identified were performed to satisfy the "once per ten year" requirements described in ASME Section XI, Code Case N-498-4. Boundaries for the pressure tests are described in the VEGP-2 Inservice Inspection Plan -Second 10-Year Interval document.Examination results are discussed in the applicable sections of this report document.
The examination data for these pressure tests is available at the plant site for review upon request.System Functional Test Schedule (FTs)FT. Exam. Test Number Cat. Description 14 C-H Turbine Driven Auxiliary Feedwater Pump 1301-P4-001 Functional Test ((See Note 1)System Hydrostatic Test Schedule (HTs)H.T Exam. Test Number Cat. Description I B-P Class 1 Hydrostatic Test (See Note 1)C-H 3 C-H Safety Injection, Normal Charging & Containment Spray Pump Suction Hydrostatic Test (See Note 2)4 C-H Safety Injection Pump Discharge Hydrostatic Test (See Note 1)5 C-H Residual Heat Removal Train A Suction Hydrostatic Test System Inservice Test Schedule (ITs)IT Exam. Test Number Cat. Description 11 C-H Centrifugal Charging Pump 1208-P6-002 (Train "A") Discharge InserviceTest 12 C-H Centrifugal Charging Pump 1208-P6-003 (Train "B") Discharge Inservice Test 18 C-H Residual Heat Removal System Train "A" Inservice Test (See Note 1)19 C-H Residual Heat Removal System Train "B" Inservice Test (See Note 1)23 C-H Refueling Water Storage Tank (RWST) Inservice Test (See Note 1)System Leakage Test Schedule (LT)LT Exam. Test Number Cat. Description I B-P Class a System Leakage Test Notes: 1. Only selected portions of this test boundary were performed in the scope of this maintenance/refueling outage. Other portions of this test boundary were performed as part of the scope of the last maintenance/refueling outage.2. Only selected portions of this test boundary were performed in the scope of this maintenance/refueling outage. Some portions of this test boundary were performed as part of the scope of the last maintenance/refueling outage. The remaining portions of this test boundary are to be completed prior to the end of one year after the Second Interval.5-1 REPORTABLE INDICATION
 
==SUMMARY==
The following indication identified on the Condition Report was issued due to reportable indications or conditions being observed during the examination of either Class 1 or 2 components during the twelfth (1 2h)maintenance/refueling outage at VEGP-2 (referenced attachments are available at the VEGP plant site for review upon request): INF No. Affected Component/Area INF Disposition 107V2001 21205-E6-002-W05 Condition Report 2007103486 was written when the vendor (LMT)observed an ultrasonic indication during examination.
The indication was evaluated to the applicable ASME acceptance standards (IWB-3514.2) and was determined to be acceptable.
In conclusion, the indication observed was Code-allowable, however it is recommended that the area of interest be re-examined during the 2R 14 outage to look for any changes. Examinations for subsequent outages will be determined after the second examination.
The Indication Notification Form(s) constitute only those reportable indications or conditions observed during the SNC M & IS Department scope of work. Any reportable indications or conditions observed by VEGP Site personnel or outside contractors during their scope of work should be identified by/to the VEGP site in report document(s) which are referenced herein.6-1 OWNER'S REPORTS FOR REPAIRS OR REPLACEMENTS (FORM NIS-2)The following Owner's Reports for Repairs or Replacements (Form NIS-2) are provided for work activities documented at VEGP-2 since the last maintenance/refueling outage (2R1 1) through the completion of the twelfth maintenance/refueling outage (2R12). Reports are identified by their respective traveler number which is denoted on each of the NIS-2 reports. The originals of the NIS-2 reports are filed with their respective traveler packages at the plant site. Only those NIS-2 reports applicable to VEGP-2 are included in this report document.
Any attachments, e.g., code data reports, etc., referenced in the NIS-2 reports will be made available for review upon request at the plant site.The NIS-2s for the following travelers are included herein: 04028 05021 05026 05033 05034 05035 05037 05038 05039 05040 05042 05043 05045 05046 05047 05048 05049 05052 05053 05054 05055 05064 05066 05067 05068 05069 05070 05072 05073 05074 05075 05076 05077 05078 05088 05089 05090 05091 05092 05093 05094 05095 05099 05103**05105 05106 05107 05113**05114 05116 05117 05118 05119 05120 05121 05122 06032 07003 07017 07080 07082 07088** Traveler 05113 is certified on the same NIS-2 report as traveler 05103.7-1 ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler # 04028 y 1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkwav, Birminaham, AL Date Sheet Unit Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address 08109/06 1 of 1f 2 1 WO# 20302626 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components N/A Code Cas I L National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedl Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)1208 PIPING PULLMAN POWER N/A N/A 2K3-1208-146-01 1989 REPLACEMENT YES SYSTEM PRODUCTS 2X6AH02-30000 2F0-10122
_T -1J 7. Description of Work Fabricated and installed orifice plate with 1.2630" bore dimension at 2F0-10122.
A non-pressure retaining non-structural weld was made on this orifice by attaching an identification handle. CR# 2005110628 was initiated to document a delay in performing the system functional VT-2 examination.
I 8. TeSt Conducted:
Hydrostatic E] Pneumatic[
Nominal Operating Pressureo]
N/A [ Other E] Pressure N/A PSI Test Temp. N/A F O 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached [7 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement I Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A I Signed .t ,k.,,A-. Team Leader Date Owncr or Owner's Designee, Titl=A .CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut
'of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 01/26/04 to ..& .5WA24 and state that to the best of my knowledge and belief, the Owner has performed examinations and takIen corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer nlakes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions , 7s'.I-rspector'fi~ignature National Board, State, Province and Endorsements Date /I raenr, 
" .FORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler # 05021 0 1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date October 14, 2005 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Sheet 1 of 1_i Unit 2 2049000421 Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Voctle Type Code Symbol Stamp Authorization No.Expiration Date W/A NIA NIA Address 1205 / Residual Heat Removal System 5. (a) Applicable Construction Code ASME SEC 111 19 77 Edition, Winter 1977 Addenda, N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19R2 6. Identification Of Components Repaired or Replaced and Replacement Components Code Casd National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped I Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or SUPPOR PULLMAN N/A N/A V2-1205-030-H012 1989 REPLACEMENT YES POWER I____________________
____________________________________________
______________________________
_____________________________________
!7.Description of Work Replaced Lisega Type 30 snubber, serial number 006147701028 was replaced a rigid strut in accordance with DCP 04-V2NO00401 S. .Test Conducted:
WA[M Hydrostatic
[a Pneumatic[C]
Nominal Operating Pressure[W Other [] Pressure N/A PSI Test Temp. N/A 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of uthorization No. N/A Expiration Date N/A -Signed Teainse, Data L ~Owner dt"Owner's-Desidnee,Title CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geonria and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford.utlhpve inspected the components described in this Owner's Report during the period May 5. 2005 to ..
and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XIl.II By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insmlto, i ---eL. X Commissions
-/ ..", Inipecto:WSignature National Board, State, Province and Endorsements 6 IDate /I&qIsc ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Lj As Required By The Provisions Of The ASME Code Section XI Traveler # 05026 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Date 10/20/05 ofI Sheet 1 Of 2 Unit Name Waynesboro, GA 30830 WO# 2040414501 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Vogpte Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Winter 1972 Addenda, N/A (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 Code Case 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedi Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)RELIEF VALVE CROSBY VALVE & N56900-00-0025 N/A 2PSV-8121 1976 REPLACEMENT YES GAGE CO.7. Description of Work Replacement valve installed.
This valve s/n N56900-00-0025 was originally installed as 2PSV-8121during plant construction and is now being utilized as a rotating spare.8. Test Conducted:
Hydrostatic
[] PneumaticE]
Nominal Operating PressureE]
N/Al] Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement ASME Code, Section Xl. repair or replac Type Code Symbol Stamp N/A Certificate of' thorizat on No. N/A Expiration Date Signed 7 -_ ý. 4,7 Team Leader Date conforms to the rules of tlIe cement N/A" Owner or mner's Desi'anee.
Title/ 7" CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the Slate or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described In this Owner's Report during the period 03/30/05 to /Od-2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Commissions (54.7s-&, Ispec-'s STgn-ature-National Board, State, Province and Endorsements Date 71 , 1 ,/w, OIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS
'-#As Required By The Provisions Of The ASME Code Section Xl Traveler#
05033 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 10/17/05 1 of 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 WO# 2050240601 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date NAV NIA NAV Address 1204 /Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989 6. identification Of Components Repaired or Replaced and Replacement Components N/A Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1204-021-HO06 1989, REPLACEMENT YES SUPPORT pRODUCTS 7. Description of Work Snubber PSA-10, serial #15982 was replaced with a PSA-10 serial #16098 to support surveillance testing.8. Test Conducted:
Hydrostatic
[] Pneumatic-]
Nominal Operating Pressure[]
N/A FA] Other E] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. VN/A Expiration Date N/A Signed Team Leader Date2/ Z-C_-' O/wner pfOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut
! of-Hartford.
Connecticut have inspected the components described in this Owner's Report during the period 05/05/05.t._/0l0/i_ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Sectioni Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions
: 61. ?Sta%-__,-!ýns06ctor'A1gnature National Board, State, Province and Endorsements Date /ft 7 ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl Traveler #05034 1. Owner Southem Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet Unit 10/17/05 1 off 2 WO# 2050240701 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtile Type Code Symbol Stamp Authorization No.Expiration Date N/A W/A NIA Address 1204 / Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components N/A Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedi Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NoL PIPE PULLMAN POWER N/A N/A V2-1204-045-H004 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber PSA-IO, serial #15945 was replaced with a PSA- 10 serial #16106 to support surveillance testing.8. Test Conducted:
Hydrostatic
[] Pneumatic[]
Nominal Operating PressureEj N/A [j Other [] Pressure N/A PSI Test Temp. N/A -F 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A thorization No. N/A Expiration Date N/A Signed TearsLesder Dataitl S Own&`or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut , of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/05/05 to e, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Cede, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning ithe examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions
: 6. 7Ar(.tSignature Date J4A 09 National Board, State, Province and Endorsements ORIGINAL'FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl 05035 Traveler #10/17/05 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 1 of 1 Address 2. Plant Vogtlie Electric Generating Plant Unit 2 Name Waynesboro, GA 30830 WO# 2050240801 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voatle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1205 /Residual Heat Removal System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Cede Cas e National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, StampedI Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1205-009-H009 1989 REPLACEMENT YES SUPPORT RODUCTS _7. Description of Work Snubber PSA-1, serial #21683 was replaced with a PSA-1 serial #23195 to support surveillance testing.8. Test Conducted:
Hydrostatic
[:] Pneumatic[U Nominal Operating Pressure[]
N/A [ ~ Other Pressure N/A PSI Test Temp. NIA OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Cede, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A orization No. N. Expiration Date N/A Signed '"" Owe Team Leader Dateitl S Owner wnor's Designee,Til CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of-Hartford, Connecticut-have inspected the components described in this Owner's Report during the period 05/05/05 to .I.,aAQ2Dr, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Sectionf XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerningithe examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with Ithis' Commissions 0't  ate Tn o% Signature Date -0r National Board, State, Province and Endorsements ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#05037 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 10/17/05 1 of 2 Address 2. Plant Vogtlie Electric Generating Plant Unit Name Waynesboro, GA 30830 Address WO# 2050241301 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voctle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1305 / Condensate and Feedwater System.5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Casie National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1305-062-H007 1989 REPLACEMENT YES SUPPORT RODUCTS _7. Description of Work Snubber PSA- 100, serial #2222 was replaced with a PSA- 100 serial #2031 to support surveillance testing. The removed snubber (serial # 2222) failed an inservice functional test as documented by CR# 2005108868.
: 8. Test Conducted:
Hydrostatic
[] Pneumaticl]
Nominal Operating Pressure[]
NIAZ Other E] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of tlhte ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of uthorization No. N/A Expiration Date N/A Signed Team Leader Date Owner efOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford Connecticut have inspected the components described in this Owner's Report during the period 05/05/05 to. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions 6,A 797.,'lZt::ýl"n7p-ect-o'e5PS'Ignature National Board, State, Province and Endorsements Date ORIGINAL 0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI q 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 7 Date 1C Sheet I Unit raveler # 05038 0/13/05 of 2 WON 2050241601 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Vogtle Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A 1201 /Reactor.Coolant Svstern 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Ca.(b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No Identification Built or Replacement (Yes or NoL PIPE PULLMAN POWER N/A N/A V2-1201-031-HOO1 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-153, serial #209 was replaced with an ADO153 serial #195 to support surveillance testing.8. Test Conducted:
Hydrostatic
[] Pneumatic[
Nominal Operating Pressure[]
N/A [] Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A I Signed 2Team Leader Date / / .7 Owners Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georola and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut i oi Hartford, Connecticut have inspected the components described In this Owner's Report during the period 05105105 i t'o ' uland state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Sectionj Xl1 By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning Ithe examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with 'this insur -Commissions
$ tiona. B N. ý sbtrl2ntr National Board, State, Province and Endorsements Date /of 1 4apos-ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLAC As Required By The Provisions Of The ASME Code Section XI EMENTS 1.Traveler#
05039 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL.Address 2. Plant Voglie Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet 10125105 of 2 Unit WO# 2050241801 Repair Organization P.O. No., Job No., etc.3. Work Performed by .4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1204 / Safety Injection Svstem 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedl Component Manufacturer Serial No. No. Identification Built or Replacement (es or No)PIPE PULLMAN POWER N/A N/A V2-1204-031-H015 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-4 1, serial #1385 was replaced with an AD-41 snubber serial # 705. Replacement socket head cap screws were also installed on the transition tube assembly.8. Test Conducted:
Hydrostatic
[] Pneumatic-]
Nominal Operating PressureD N/A [] Other 51 Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A horization No. %/A Expiration Date N/A Signed .Team Leader Date Owner*`Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut I 01 Hartford Connecticut have inspected the components described in this Owner's Report during the period 05/05/05 I to /" = and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning Ithe examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions
&A. 7SM"I InpeoU* e Signature National Board, State, Province and Endorsements Date /0/s ? /ll I ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi'1 Traveler#
05040 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 10/25/05 of 1, 2 Address 2. Plant Votle Electric Generating Plant Name Waynesboro, GA 30830 WO# 2050241901 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vootle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A NIA Address 1201 / Reactor Coolant Svstem 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped!Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1201-051-H006 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-41, serial #888 was replaced with an AD-41 snubber serial # 1510. Replacement socket head cap screws were also installed on the transition tube assembly.8. Test Conducted:
Hydrostatic
[] Pneumatic[-]
Nominal Operating Pressure[]
NWA [ Other J Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NIA Certificate' of Authorization No. N/A Expiration Date N_/A Owner r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut ol Hartford.
Coongecticut have inspected the components described in this Owner's Report during the period 05/05/05 I to & _ .& and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section .Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with 'this-. I 1 /
Commissions
&At 2f& I NZ_.ector5 -Cmnature -issons National Board, State, Province and Endorsements Date_____
_-
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler # 05042 1. Owner Southern Nuclear Operating Company Date Name 40 Inverness Center Parkway, Birmingham, AL Sheet 10/25/05 I of 2 Address 2. Plant Vogtle Electric Generating Plant Unit Name Waynesboro, GA 30830 WO# 2050242201 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voatle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC I11 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped!Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A NIA V2-1208-449-HO02 1989 REPLACEMENT YES I SUPPORT PRODUCTS _7. Description of Work Snubber AD-41, serial #1509 was replaced with an AD-41 snubber serial # 891. Replacement socket head cap screws were also installed on the transition tube assembly.S. Test Conducted:
Hydrostatic
[] Pneumatic[-
Nominal Operating Pressure[]
N/A M] Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Team Leader Date , " Owne 6r Owner's Delinee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georcia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut i of Hartford, Connecticut have Inspected the components described In this Owner's Report during the period 05/16/05 to ZL and state that to the best of my knowledge and belief, the Owner has performed examinations and talken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code, Section 1Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions G %.',-Israpeb'r's Signature National Board, State, Province and Endorsements Date I/,9AW 6dr&<
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS
.As Required By The Provisions Of The ASME Code Section XI Traveler#
05043 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 10/13/05 1 of 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 WO# 2050242301 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voatle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A NAV Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Cas (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NO)PIPE PULLMAN POWER N/A N/A V2-1208-002-H009 1989 REPLACEMENT YES SUPPORT PRODUCTS _7. Description of Work Snubber AD-43, serial #303 was replaced with an AD-43 serial #244 to support surveillance testing. The I removed snubber (serial # 303) failed an inservice functional test as documented by CR# 2005108573.
: 8. Test Conducted:
Hydrostatic
[] Pneumatic[]
Nominal Operating Pressure[]
N/A [] Other [] Pressure N/A PSI Test Temp. N/A F 9. Remarks See Item 7 Applicable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A L Certificate of Authorization No. /7 N/A Expiration Date N/A i Signed Team Leader Date / "-Ow r or Owner'd Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford Connecticut have inspected the components described in this Owner's Report during the period 05116/05 I to .T 011 .42W -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, SectionI XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins 43 JO07/09 7 ,4 Commissions
& u* Z.G N Signature National Board, State, Province and Endorsements Date 1 2/ /nI g L6 4.;ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Y Traveler#
05045 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 1 Of 2 Address 2. Plant Voltie Electric Generating Plant Name Waynesboro, GA 30830 Address WO# 2050242601 Repair Organization P.O. No., Job No., etc.3, Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtie Address Type Code Symbol Stamp Authorization No.Expiration Date 1301 / Main Steam System N/A N/A N/A 5. (a) Applicable Construction Code ASME SEC ill 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement es or No)PIPE PULLMAN POWER N/A N/A V2-1301-108-HO02 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-73, serial #602 was replaced with an AD-73 serial #316 to support surveillance testing.8. Test Conducted:
Hydrostatic El Pneumatic[]
Nominal Operating PressureE]
N/A j[] Other E] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A -Signed __________
'_Team Leader Date CERTIFICATE OF INSERVICE INSPECTION I 1, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut j of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/16/05 I to 12 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owners Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this 3z fi 1o .arCommissions n National Board, State, Province and Endorsements Date ioA' 7'/ags:o ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
05046 (1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birnringham, AL Date Sheet Unit 10/12/05 1 of 2 2. Plant Address Vogtue Electic Generating Plant Name Waynesboro, GA 30830 Address WO# 2050242701 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant VOotle Type Code Symbol Stamp Authorization No.Expiration Date/A N/A N/A Address 1301/ main Steam System 6. (a) Applicable Construction Code ASME SEC Ill 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Cas National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, StampedI Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1301-119-HO06 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-501, serial #501 was replaced with an AD-501 serial #405 to support surveiflance testing.8. Test Conducted:
Hydrostatic
[] Pneumatic["]
Nominal Operating Pressure[]
N/A [ Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of AA horization No. N/A Expiration Date N/A Signed Team Leader Date Z Owner K Owner's Designee, Title f 7, CEIRTIFIC;ATE:
OF INSERVICIE INSPECT;ION teSae o I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartfor.Connecticut have inspected the components described in this Owner's Report during the period 05/16/05 I to -, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examninations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this insCommissions
: 64. 7S'(V.&#xfd;j&#xfd;In~pecflafs SignatureT Date 10 1 I7IA wty National Board, State, Province and Endorsements ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler #0 05047 Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet 10/12/05 I of 2 Unit WO# 2050242801 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voatle Typo Code Symbol Stamp Authorization No.Expiration Date N/A NIA N/A Address 1301 /Main Steam Svstem 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Appllcable Edition of Section Xl Utilized for Repairs or Replacements 1989 Code Cas" I 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No!)PIPE PULLMAN POWER N/A N/A V2-1301-191-H002 1989 REPLACEMENT YES SUPPORT PRODUCTS _7. Description of Work Snubber AD-71, serial #1095 was replaced with a Lisega Type 30 snubber serial #30500235/026.
A replacement spacer flange was also installed in resolution to CR# 2005107893.
: 8. Test Conducted:
Hydrostatic E] Pneumatic[]
Nominal Operating PressureD N/A F!] Other [] Pressure AN/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed L Team Leader Date Own efor Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and insurance Co. of Connecticut of.Harford, Conecticut
-have inspected the components described in this Owner's Report during the period 05/16/05 to /.,L -*ki, r and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section! XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning i the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions rw4. 7S.Yt-*, InsI(ctor;0IgnatuF9 National Board, State, Province and Endorsements Date ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi Traveler#
05048 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 10/13/05 1 of 1I 2 2, Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address WO# 2050243001 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vootle.Type Code Symbol Stamp Authorization No.Expiration Date N/A NIA N/A Address 1302 / Auxiliary Feedwater System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Ca.(b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components e National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampoe Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NoL PIPE PULLMAN POWER N/A N/A V2-1302-109-H015 1989 REPLACEMENT YES SUPPORT pRODUCTS 7. Description of Work Snubber AD-501, serial #176 was replaced wifth an AD-501 serial #135 to support surveillance testing.S. Test Conducted:
Hydrostatic E] Pneumatic[]
Nominal Operating Pressure[]
NIA [ Other [ Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A~thorization No. N/A Expiration Date NIA Signed -Team Leader Date L Owner (fF Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION tot I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georcia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut Lof Hartford.
Connecticut have inspected the components described'in this Owner's Report during the period 05/16/05 I to 1 c and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Sectioni Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with 'this inspeJ / , .inspe. " , Commissions I'-- In@necto0%
Signature National Board, State, Province and Endorsements Dote lolli 7/,.?ADC ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
05049 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 10/12105 I of 2 2. Plant Address Vogue Electric Generating Plant Name Waynesboro, GA 30830 W0# 2050243401 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Vogue Type Code Symbol Stamp Authorization No.Expiration Date N/A AN/A A/A Address 1201 / Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Cas 3 National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedi Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1201-030-H620 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-1601 serial #56 was replaced with an AD-1601 serial #45 to support surveillance 8. Test Conducted:
Hydrostatic
[] Pneumatic
] Nominal Operating Pressure []N/A [] Other fl Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE lWe certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of orizatlon No. N/A Expiration Date NIA Signed r _ Team Leader Date Owner Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the StateaI or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Han~ord Connecticut have inspected the components described in this. Owner's Report during the period 05109/05 I Io ZZ 2and state that to the best of my knowledge and belief; the Owner has performed examinations and taken corrective measre in this Owners Report in accordance with the requirements of the ASME Code, Section I Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecthi*
.Commissions 75i&.n ctls Signature National Board, State, Province and Endorsements Date IO / 71AODCo ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#05052 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 10113105 of 2 Address 2. Plant Vogtle Electric Generating Plant Unit Name Waynesboro, GA 30830 WO# 2050243801 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1204 / Safet Injection System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1204-020-H008 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-1601, serial #328 was replaced with an AD-1601 serial #322 to support surveillance testing.8. Test Conducted:
Hydrostatic
] Pneumatic[
Nominal Operating Pressure[N/A E] Other [ Pressure NIA PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of thorization No. NIA Expiration Date N/A Signedner J 7Tear Leader DateTitle L ~ ~ ~ we $Owner'sDeinTtl CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by .Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford.
Connecticut have inspected the components described in this Owner's Report during the period 05/09/05 'to ID.JiS.1.
aZand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures' described in this Owners Report in accordance with the requirements of the ASME Code, Section: Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning ithe examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insrw"- f C Commissions
&~.s N&#xfd;-- 71na "011 ignaturs National Board, State, Province and Endorsements Date_________
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler # 05053 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Date Sheet 10/18/05 1 of I 2 Unit Name Waynesboro, GA 30830 WO# 2050244201 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date NAV NIA N/A Address 1204 / Safety Injection System 5. (a) Applicable Construction Code ASME SEC 11 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedl Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NW_PIPE PULLMAN POWER N/A N/A V2-1204-023-H003 1989 REPLACEMENT YES SUPPORT RODUCTS 7. Description of Work Snubber AD-5503, serial #260 was replaced with an AD-5503, serial #244 to support surveillance testing. A replacement load stud was also installed on the pipe clamp end of the AD-5503, serial # 244.8. Test Conducted:
Hydrostatic
] Pneumatic[j Nominal Operating Pressurefl N/A O Other L Pressure AVA PSI Test Temp. WA OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code, Section XI. rep replacement conforms to the rules of the kair or replacement Type Code Symbol Stamp Certificate of uthorization No.N/A N/A Expiration Date Team Leader Date / 11;7 , N/A Ownjfor Owner's D6sianee.
Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/09/05 to ,,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning
:the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions
_ _ _ ___,-n)pect6Ps Signature-National Board, State, Province and Endorsements Date J1 / .... f H I ORIGINAL.FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vo-tle Electric Generating Plant'Name Waynesboro, GA 30830 Address Date Sheet Unit Traveler#
05054 10114/05 I of 1 2 WO# 2050244 701 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A NIA N/A Address 1305 / Condensate and Feedwater System 5. (a) Applicable Construction Code ASME SEC It/ 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 Code Case 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped,* Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NO)PIPE PULLMAN POWER N/A N/A V2-1305-058-HO05 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-12501, serial #185 was replaced with a Lisega Type 30 snubber serial #30500042/09.
: 8. Test Conducted:
Hydrostatic
[] Pneumatic[]
Nominal Operating Pressure['
N/A F] Other El Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of "te ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed Team Leader Date 0Q Ownellor Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hanftord, Connecticut have inspected the components described In this Owner's Report during the period 05/09/05 ;to 4a ,nd state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective rmeasures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with lhis inspeJ,&- 6 ,IbY,'#a Commissions r"ill. ?ZM qM -k,&#xfd;&#xfd; limpecTgors-Signature National Board, State, Province and Endorsements Date j O/42gLQ9QN:
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 0 1. Owner Southern Nuclear Operatinc Comoanv Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Voglle Electric Generating Plant Name Waynesboro, GA 30830 Date Sheet Traveler # 05055 10/25/05 I of 1 2 Unit WO# 2050461201 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A WA N/A Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC I1/ 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 198 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped;Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1208-002-H004 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-41, serial #722 was replaced with an AD-41 serial #612 to support surveillance testing. Replacement socket head cap screws were also installed on the transition tube assembly.
The removed snubber (serial # 722) failed inservice functional testing as documented by CR# 2005108389.
: 8. Test Conducted:
Hydrostatic
[] Pneumatic-Nominal Operating PressureL N/A [ Other [ Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. 4N/A Expiration Date NWA Signed -.Team Leader Date X?Owner qfwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described In this Owner's Report during the period 05/09/05 to i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section &#xfd;Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions Ad ~sSignature National Board, State, Province and Endorsements Date___________
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI I.qI'Traveler # 05064 1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit October 31, 2005 1 Of 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 2051667001 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by -4. Identification of System Maintenance Department Name Plant Voqtle Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/IA N/A 1201 / Reactor Coolant Svstem 5. (a) Applicable Construction Cede ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced,.
Stamped.Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NO)PIPE SUPPORT PULLMAN N/A N/A V2-1201-042-H005 1989 REPLACEMENT YES POWER 7.Description of Work Snubber AD -41, serial#756 was replaced with AD-41 serial #298 to support surveillance testing, also replaced socket head screw.8. Test Conducted:
Hydrostatic
[] Pneumatic[
Nominal Operating Pressure[l N/A [] Other [a Pressure N/A PSI Test Temp. N/A 9. Remarks See Item 7 OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A thorization No. N/A Expiration Date N/A Signed Team Leader Date, Z2 L &#xfd;6 Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartfrd.Conn have inspected the components described in this Owner's Report during the period May 5. 2005 to -,tg -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken correclive measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning
:the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this in Commissions G4 >1 Iilpp s Signature National Board, State, Province and Endorsements Date_________________
a ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS.
9 As Required By The Provisions Of The ASME Code Section X T Traveler # 050 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date October 14, 2005 2. Plant Address Voglie Electric Generating Plant Name Waynesboro, GA 30830 Address Sheet 1 of Unit 2 2050267801 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vootle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1206 / Containment Spray System 5. (a) Applicable Construction Code ASME SEC IIl 19 77 Edition, Winter 1977 Addenda, .-Ab4 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 W/.- q9-,i 6. Identification Of Components Repaired or Replaced and Replacement Components ,C/M7/0o1 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped !Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No&#xfd;PiPE SUPPORT PULLMAN N/A N/A V2-1206-002-HO02 1989 REPLACEMENT YES POWER _7. Description of Work Snubber AD -501, serial #163 was replaced with Lisega Type 30, serial #04616500/070 to support surveillance I testing 8. Test Conducted:
WA[9. Remarks See Item 7 Hydrostatic
[a Pneumatic[a Nominal Operating Pressure[r1 Other [ Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached I CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of thl ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A thorization No. N/A Expiration Date N/A Signed -Team Leader Date Ownefor Owner's D0signre, Title U CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State !or Province of Georaia and employed by Hartford Steam Boiler Inspection ahd Insurance Co. of Connecticut of ..Mg Coonnciaut have inspected the components described in this Owner's Report during the period May 9. 2,05 to 1 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section iXI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspecton.
Commissions
&# 75$Cc--'-1fi"ect-os Signature National Board, State, Province and Endorsements Date /0/31 ,L=c'!
IJ ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Cede Section XI Traveler #}bar 14. 2005 05067.1.Owner Southern Nuclear Operating Company Date 0cto Octo r 14, 20,05 Name 40 Invemess Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Sheet 1 of I Unit 2 2050268101 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtlie Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A V/A 1302 / Auxiliary Feedwater System 5. (a) Applicable Construction Cede ASME SEC III 19 77 Edition, Winter 1977 Addenda, N/A (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Cede Case National Repaired, ASME Codb Name of Name of Manufacturer Board Other Year Replaced, Stamped I Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE SUPPORT PULLMAN N/A N/A V2-1302-109-H018 1989 REPLACEMENT YES POWER 7. Description of Work Snubber AD -1603, serial #677 was replaced with Lisega Type 30, serial #04616570/028 to support surveillance testing 8. Test Conducted:
9A[I 9. Remarks See Item 7 Hydrostatic
[a Pneumatic[o Nominal Operating Pressure[]
Other (0 Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Cede, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate ofKhorization No. N/A Expiration Date N/A Signed i Team Leader Date Owner ol~wner's Desigr~ee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geormla and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of -ave inspected the components described in this Owner's Report during the period May 9. 2005 to state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures daescribed in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer st~all be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins ct.Commissions
&t ,s1--%,-,L.. -Weto1rSIiatte-National Board, State, Province and Endorsements Date 0 r.ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI I 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Traveler#
05068 10/26/05 of 1 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Unit WO# 2050268201 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date NIA N/A N/A Address i 1208 / Chemical and Volume Control System I 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1208-01 1-H045 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-41, serial #854 was replaced with a Usega Type 30 snubber serial # 30500235/024.
Replacement socket head cap screws were also installed on the transition tube assembly.B. Test Conducted:
N/A1 Hydrostatic E] Pneumatic[]
Nominal Operating Pressure[]
Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Cede Symbol Stamp N/A Certificate of Authorization No. /A Expiration Date N/A Signed Team Leader Date /0 Owner orA ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of -Georqia end employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/09/05 to A, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning ithe examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this In sl~al~..--
.led , Commissions
$'.. -\slectoeZ Signature National Board, State, Province and Endorsements Date /7/f '
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
05069 1. Owner Southern Nuclear Operatinq Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet Unit 10/14/05 of 1 2 WO# 2050268301 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1204 / Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1204-192-HOO1 1989 REPLACEMENT YES SUPPORT PRODUCTS _7. Description of Work Snubber AD-503, serial #371 was replaced with a Llsega Type 30 snubber serial #04616500/069.
.Test Conducted:
Hydrostatic F1 Pneumatic[]
Nominal Operating Pressure[]
N/A F] Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of bhe ASME Code, Section Xl. repair or replacement..
Type Code Symbol Stamp W/A Certificate of Authorization No. ./A Expiration Date N/A Signed ' Team Leader Date Owner 01Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/09/05 1 to ja end state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Cede, Section' Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with' this Commissions
.% --;&#xb6;nd`09c~s Signature National Board, State, Province and Endorsements Date Date A u~ h, ,Aim~...E Dat 64 TF a&--.&
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#-
05070 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Address 2. Plant Vogtle Electric Generating Plant 10/14/05 of 1 2 WO# 2050268401 Unit Name Waynesboro, GA 30830 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Address Type Code Symbol Stamp Authorization No.Expiration Oate N/A NAM NAV 1301 /Main Steam System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1301-106-H005 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-5501, serial #281 was replaced with a Llsega Type 30 snubber serial #04616590/045.
: 8. Test Conducted:
Hydrostatic
[] Pneumaticjj Nominal Operating Pressure[]
N/A Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of ihe ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A ythorization No. 1 N/A Expiration Date N/A Signed Team Leader Date t'7n t Owner dOwner's Dest'griee, Title 4&#xfd;CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georaia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut I of CHartfor Connecticut have inspected the components described in this Owner's Report during the period 05/09/05 to n and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.I By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with 1 this Commissions InsAectg0-Signature-National Board, State, Province and Endorsements Date __ _ _ _
FORM NIS-2 OWNER'S REQ05 JLA S OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#05072 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Date Sheet Unit 10/17/05 1 of 2 Name Waynesboro, GA 30830 WO# 2050268701 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Voctle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No')PIPE PULLMAN POWER NWA N/A V2-1208-006-H040 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-73, serial #620 was replaced with a Lisega Type 30 snubber serial #00614800/045 to support surveil-lance testing.8. Test Conducted:
NA 3 Hydrostatic
[] Pneumatic[:]
Nominal Operating Pressure[]
Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. _ __ NExpiration Date N/A Signed Team Leader Date /.Owner orAner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the Slate or Province of Georcia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut i of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/16/05 to -ea, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section; XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerningithe examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this InsCommissions 4sctatSignature National Board, State, Province and Endorsements Date_ _
S ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI-/I 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Traveler#
05073 10/25/05 of 1 2 Address 2. Plant Vogtle Electric Generating Plant Unit Name Waynesboro, GA 30830 WO# 2050269001 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by Maintenance Department Name Plant Vootle Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A 1208 / Chemical and Volume Control Systemn 4. Identification of System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Appllcable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1208-01 1-H043 1989 REPLACEMENT YES SUPPORT PRODUCTS _7. Description of Work Snubber AD-43, serial #249 was replaced with a Lisega Type 30 snubber serial #30500235/031.
: 8. Test Conducted:
Hydrostatic Q Pneumatic-Nominal Operating PressureQ N/A [ Other [ Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of uthorization No. _/_A Expiration Date N/A Signed Team Leader Date ',2-or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut lol Hartford.
Connecticut have inspected the components described In this Owner's Report during the period 05/16/05 , to -and state that to the best of my knowledge and belief, the Owner has performed examinations and takien corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section ;Xl.I By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer sh~all be liable in any manner for any personal injury or property damage or a loss. of any kind arising from or connected with this-":Commissions Date ie National Board, State, Province and Endorsements r DATE "
*D ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl Traveler #0I 05074 Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet Unit 10/26105 1 of 2 WO# 2050269501 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC 1// 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped'Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1208-01 1-HO50 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work SnubberAD-41, serial #1390 was replaced with a Lisega Type 30 snubber serial # 30500235/027.
Replacement socket head cap screws were also installed on the transition tube assembly.8. Test Conducted:
Hydrostatic
[] Pneumatic[]
Nominal Operating Pressure[]
N/A [] Other [ Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Team Leader Date 1 A -" OwneVor Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford Connecticut have inspected the components described in this Owner's Report during the period 05/16/05 to / and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code, Section; Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer s'hall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this_______________Commissions r at ns ter ' ignAture National Board, State, Province and Endorsements ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl Traveler#N 05075 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet 10/14/05 of 1 2 WO# 2050269801 Unit Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogte Address Type Code Symbol Stamp Authorization No.Expiration Date 1301 / Main Steam System NIA N/A N/A 5. (a) Applicable Construction Code ASME SEC I1/ 19 77 Edition, Winter 1977 Addenda, N-249.1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 Code Case 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement
_(Yes or No)PIPE PULLMAN POWER N/A N/A V2-1301-106-H002 1989 REPLACEMENT YES SUPPORT RODUCTS 7. Description of Work Snubber AD-5503, serial #439 was replaced with a Lisega Type 30 snubber serial #04616590/25.
: 8. Test Conducted:
Hydrostatic
[] Pneumaticf]
Nominal Operating Pressuref]
N/A OtherE] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate ofAuthorization No. N/A Expiration Date N/A Signed ee- f 77z Team Leader Date d Z /ZJ Ownor Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Harfordg.
Congepcticut have inspected the components described in this Owner's Report during the period 05/16/05 to / and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inseemt l,-- Commissions GiW 7(o i.._&#xfd;.. spefrs Signatre' National Board, State, Province and Endorsements Date ,/1~ X ,
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl Traveler#
05076 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet Unit 10/14/05 of 2 WO# 2050270201 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1208/Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NO)PIPE PULLMAN POWER N/A N/A V2-1208-225-HO04 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-41, serial #893 was replaced with a Lisega Type 30 snubber serial #30500235/028.
Replacement socket head cap screws were also installed on the transition tube assembly.8. Test Conducted:
N/A]9. Remarks See Item 7 Hydrostatic
[] Pneumatic[]
Nominal Operating Pressure[]
Other M Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed " Ow -2tl Team Leader Date OwLrOnr' eine Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georaia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/16/05 to J0( and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section! XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Commissions (y*
National Board, State, Province and Endorsements Date___________
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
05077 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 10114105 1 of I 2 2. Plant Address Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address WO# 2050270901 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC I1/ 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Caie National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement Yes or N')L PIPE PULLMAN POWER N/A N/A V2-1208055-H046 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-153, serial #418 was replaced with a Lisega Type 30 snubber serial #04617090/052.
: 8. Test Conducted:
Hydrostatic E] Pneumatic[]
Nominal Operating Pressure[]'
N/A [] Other Q Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this ASME Code, Section Xl. rep replacement conforms to the rules of the air or replacement Type Code Symbol Stamp Certificate of Authorization No.Signed NIA NIA Expiration Date N/A Team Leader Date Ti";+CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut I of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/1/05 I to 0 1i and state that to the best of my knowledge and belief, the Owner has performed examinations and tiken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Sectionj Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerningI the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with Ithis ind22;- -Commissions 64 7'r6 L MIpekr Signature National Board, State, Province and Endorsements Date /1 -7_/.2Oc=x ORIGINAL FORM NIS-2 OWNER'S REPORT FORREPAIRS OR REPLACEMENTS 7 As Required By The Provisions Of The ASME Code Section XI Traveler#
05078 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 10/14/05 1 of1 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Unit WO# 2050271501 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1202 / Nuclear Service Cooling Water System 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped" Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1202-229-H024 1989 REPLACEMENT YES SUPPOFRT PRODUCTS 7. Description of Work Snubber AD-501, serial #152 was replaced with a Lisega Type 30 snubber serial #04616500/077.
: 8. Test Conducted:
Hydrostatic
[] Pneumatic[l Nominal Operating Pressure[]
N/A [] Other El Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. f N/A Expiration Date N/A Signed /<,~%~' Team Leader Date Owrer or Owner's/Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 05/16/05 to e and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer 6hall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions 7C%.Date o/1t V/."rirS National Board, State, Province and Endorsements Z ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
05088.1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit October 18, 2005 1 Of 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address 2049505602 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voqtle Address Type Code Symbol Stamp Authorization No.Expiration Date 1204 /Safetv Iniection System N/A N/A W/A 5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Reiplacements 19f92 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1&1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)VALVE WESTINGHOUSE I0001CS9900000 W23461 2-1204-U6-079 1981 REPLACEMENT YES 000S740018
& I A1 I I A 7. Description of Work Circular mounting pads (approximately I* diameter and 1/4" thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the external-bottom-side of the valve body. Installation of the mounting pads was completed in accordance with MDC 04-V2M056.
: 8. Test Conducted:9. Remarks See Item 7 Hydrostatic
[a Pneumatic[]
Nominal Operating Pressure[]
Other [[ Pressure N/A PSI Test Temp. N/A Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. o, , NIA Expiration Date N/A Signed <eam Leader Date Owfier or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford Connecticut have inspected the components described in this Owner's Report during the period June 22. 2005 to 440LaLIgg 1  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins -0 Commissions (oq 7-'L l6spec~r's Signature National Board, State, Province and Endorsements Date__________
41 ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
05089.1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birminqham, AL Date Sheet Address 2. Plant Vogtle Electric Generating Plant October 18,2005 1 of 2 2049505602 Unit Name Waynesboro, GA 30830 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voctle Type Code Symbol Stamp Authorization No.Expiration Date N/A NIA N/A Address 1204 /Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1& 1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)VALVE WESTINGHOUSE 10001CS9900000 W23460 2-1204-U6-080 1981 REPLACEMENT YES 000S740017
: 7. Description of Work Circular mounting pads (approximately 1" diameter and 1/4" thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the external-bottom-side of the valve body. Installation of the mountina pads was completed in accordance with MDC 04-V2M056.
: 8. Test Conducted:
R k A[m 9. Remarks See Item 7 Hydrostatic M Pneumatic[[]
Nominal Operating Pressure[o Other [a Pressure N/A PSI Test Temp. N/A Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. ,tS4 Expiration Date N/A Signed Team Leader Date /cn //Ze, ne-Owner or 0'ners &#xfd;Designd, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georcia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford.QpnLio~have inspected the components described in this Owner's Report during the period June 22, 2005 to .and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions G4 Ihspeo ~r's Signature
-National Board, State, Province and Endorsements Date i,/ i x.r I ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl LI@ 1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit Traveler # 05090 October 18, 2005 1 of 1 2 2049505602 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voqtile Address Type Code Symbol Stamp Authorization No.Expiration Date 1204 / Safetv Iniection System N/A N/A N/A 5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1 9P9 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1& 1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)VALVE WESTINGHOUSE 10001CS9900000 W23462 2-1204-U6-081 1981 REPLACEMENT YES 000S740019
: 7. Description of Work Circular mounting pads (approximately 1 diameter and 114' thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the external-bottom-side of the valve body. Installation of the mounting pads was completed in accordance with MDC 04-V2M056.
: 8. Test Conducted:
WA[M 9. Remarks See Item 7 Hydrostatic
[ Pneumatic[]
Nominal Operating Pressure[]
Other FM Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A thorization No. N/A Expiration Date N/A Signed Team Leader Date / '0/- Z CJ Owner'rOwner's Desi~nee, tle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by Hartford Steam Boiler Insiection and Insurance Co. of Connecticut of Hartford, Connect have inspected the components described in this Owner's Report during the period June 22. 2005 to 44.L j ?a wrQ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the, Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insocin in&#xfd;&#xfd;- i& Commissions 6,4 7r6 M spetor's Signature National Board, State, Province and Endorsements Date a ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI ti Traveler # 05091 October 18,2005.1. Owner 2. Plant Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet 1 of 1 Unit 2 2049505602 Repair Organization P.O. No., Job No., etc.'3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date _NWA N/A N/A Address 1204 / Safety Injection System 5. (a) Applicable Construction Code .ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19g2 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1& 1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)VALVE WESTINGHOUSE 10001CS9900000 W23464 2-1204-U6-082 1981 REPLACEMENT YES 000S740021
: 7. Description of Work Circular mounting pads (approximately 1 diameter and 114' thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the extemal-bottom-side of the valve body. Installation of the mountino Dads was completed in accordance with MDC 04-V2M056.
: 8. Test Conducted:
WA[9. Remarks See Item 7 Hydrostatic
[0 Pneumatic(_
Nominal Operating Pressure[[3 Other [0 Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate oAuthorization No. N/A Expiration Date NIA Signed Team Leader Date Dte ? call Own(for Owner's Desfgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of HfLfr__ConciggLutJLpave inspected the components described in this Owner's Report during the period June 22. 2005 to 1104 -2= and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report, in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with thisCommissions 64 7Xer SSnNational Board, State, Province and Endorsements a SDate Z/ o&#xfd;I ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl 9 Traveler # 05092@ 1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit October 18, 2005 1 of 1 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address 2049505602 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtie Type Code Symbol Stamp Authorization No.Expiration Date NIA N/A NIA Address 1204 / Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1 98f9 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1& 1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)VALVE WESTINGHOUSE 10001CS9900000 W23465 2-1204-U6-083 1981 REPLACEMENT YES 000S740022
: 7. Description of Work Circular mounting pads (approximately 1 diameter and 1/4' thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the external-bottom-side of the valve body. Installation of the mounting pads was completed in accordance with MDC 04-V2M056.
: 8. Test Conducted:
: 9. Remarks See Item 7 Hydrostatic
[] Pneumatic[U Nominal Operating Pressure[C]
Other [n Pressure NIA PSI Test Temp. N/A Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed 640z- KTeam Leader Date -Z2 2 -- '-owner Deeighee, Title" CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Qonnetcu,have inspected the components described in this Owner's Report during the period June 23. 2005 to. LL4 2sC and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be. liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this-Commissions Gr* 7xa'7 hspeor's Signature National Board, State, Province and Endorsements Date l oR/GINAL FORM NIS-2 OWNER'S FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl YI Traveler#
05093 October 18,2005 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date 2. Plant Address Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Sheet 1 of I Unit 2 2049505602 Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Voatle Type Code Symbol Stamp Authorization No.Expiration Date NIA N/A N/A Address 1204 / Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19&9 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1& 1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or Noi VALVE WESTINGHOUSE I0001CS9900000 W23466 2-1204-U6-084 1981 REPLACEMENT YES 000S740023
: 7. Description of Work Circular mounting pads (approximately 1 diameter and 114' thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the external-bottom-side of the valve body. Installation of the mountino Dads was comoleted in accordance with MDC 04-V2M056.
external-bottom-side of the valve bodv. Installation of the mountino Dads was comnleted in accordance with MDC 04-V2MO56.
B. Test Conducted:
NAIA 9. Remarks See Item 7 Hydrostatic
[] Pneumatic[]
Nominal Operating Pressure [Q Other [0 Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Aut orization No. N/A Expiration Date N/A SSigned .Team Leader Date Owner or Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Insoection and Insurance Co. of Connecticut of -Hartford Connectgi , have inspected the components described in this Owner's Report during the period June 23, 2005 to l and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this,4 ay kCommissions C4A 7--T&' Inipo s Signature National Board, State, Province and Endorsements Date Z -!o/c.'-4l ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI@ 1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit Traveler # 05094 October 18, 2005 1 of 2 2049505602 Address 2. Plant VogUe Electric Generating Plant Name Waynesboro, GA 30830 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A NAV N/A Address 1204 / Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1& 1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)VALVE WESTINGHOUSE 10001CS9900000 W23463 2-1204-U6-085 1981 REPLACEMENT YES 00OS740020
: 7. Description of Work Circular mounting pads (approximately I diameter and 1/4, thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the external-bottom-side ot the valve body, installation ot the mountlno nads was comnleted in accordance with MDC 04-V2M056.
external-bottom-sli of the valve body. Installation of the moundna nads was comnlated in accordance with MDC 04-V2MO56.
: 8. Test Conducted:
Hydrostatic
[o Pneumatic[n Nominal Operating Pressure['
N/A Other [[ Pressure N/A PSI Test Temp. N/A 9. Remarks See Item 7 OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Au horization No. N/A Expiration Date N/A Signed Team Leader Date 6 / Z L/f Owne Owner s Desibnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georaia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Ha Connectut have in npected the components described in this Owner's Report during the period June 23, 2005 to Y/ If 2 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measules described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins Commissions
.. 7r(.IntpecU*'s Signature National Board, State, Province and Endorsements 6I IDate Li/al/AaccisT ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI'1.1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit Tra veler # 05095 October 18, 2005 1 of 1 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address 2049505602 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vootle Type Code Symbol Stamp Authorization No.Expiration Date NIA NIA N/A Address 1204/ Safety Injection System 5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1974 Addenda, (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 198 6. Identification Of Components Repaired or Replaced and Replacement Components 1553-1&1649 Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)VALVE WESTINGHOUSE I0001CS9900000 W25788 2-1204-U6-086 1981 REPLACEMENT YES 000S740032
: 7. Description of Work Circular mounting pads (approximately 1 diameter and 1/4" thick) for acoustic sensors were fabricated from SA-240 TP 304 plate and welded to the valve. One pad is located on the estemal-top-side of the valve outlet and the second is located on the I external-bottom-side of the valve body. Installation of the mounting pads was completed in accordance with MDC 04-V2M056.
: 8. Test Conducted:
NA 9. Remarks See Item 7 Hydrostatic
[] Pneumatic[Q Nominal Operating Pressure[]
Other rn Pressure N/A PSI Test Temp. N/A oF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date NIA Signed AO-r 44 O e Team Le der Date iei Owner or Ojf~ier's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georela and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford Connecticut have inspected the components described in this Owner's Report during the period June 23. 2005 to Z and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins 0-k- 'Commissions (U14 7S&1" I lnlr pectc Signature National Board, State, Province and Endorsements Date /1/0/ t(&b 4 IL-, ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI"~1 Traveler#
05099 I 1. Owner Southern Nuclear.Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 01/19106 1 of 2 Address 2. Plant Vogtle Electric Generating Plant Unit Name Waynesboro, GA 30830 WO# 2049001102 and PO# 7063483 Repair Organization P.O. No., Job No., etc.Address 3. Work Performed by Westinghouse Electric Co. / SNC Name 44 Inverness Center Pwy., Ste. 148.Birmingham, AL 35242 / Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A NIA N/A 4. Identification of System Address 1201 / Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Summer 1972 Addenda, N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped, Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)REACTOR COMBUSTION 7372 22004 2-1201-V6-001
.1979 REPLACEMENT YES I VESSEL ENGINEERING, INC. _7. Description of Work The male flange assembly on the instrument port column was replaced by a new design core exit thermocouple nozzle assembly (CETNA). The CETNA assemblies were installed on vessel penetration numbers 75, 76, 77 and 78 in accordance with DCP 2049001101.
: 8. Test Conducted:
Hydrostatic
[] PneumaticE]
Nominal Operating PressurefX N/AEU OtherE] Pressure N/A PSI Test Temp. N/A -F 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate ofAuthorization No. N/A Expiration Date N/A Signed Team Leader Date o -0 L Ow~er or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by -Hartford Steam Boiler Inspection and Insurance Co. of Connecticut
.of Hartford.
Connecticut have inspected the components described in this Owner's Report during the period 08/29/05 1 to / and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section IXl.By signing this certificate,-
neither the Inspector nor his employer makes any warranty, expressed or implied, concerning
!the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.Commissions rf& --I N-_.;-'npectcASgntre National Board, State, Province and Endorsements i Date /_________(___
F ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 9 05103 Traveler#08/16/06 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet I of 3 Unit 2 WO# 2040160001 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date NIA NWA.N/A Address 1501 / Containment Cooling System 5. (a) Applicable Construction Code ASME SEC ill 19 77 Edition, Winter 1977 Addenda, N-294 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Codb Name of Name of Manufacturer Board Other Year Replaced, Stamped I Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)HEAT AEROFIN 970801 863 2-1501-A 7-002-000 1997 REPLACEMENT YES -EXCHANGER 7. Description of Work One lefthand cooling coil was replaced.
Cooling coil installation required cutting and splicing the support frame;welding of the coil housing to the support frame; and pipe flange bolting replacement.
Welds on the coil support structure were mistakenly ground (CR# 2005108509) and were re-welded per Traveler#
05113. A copy of Form N- 1 for the replacement cooling coil is attached.
-8. Test Conducted:
Hydrostatic E] Pneumatic[]
Nominal Operating PressureX]I N/A[] Other Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed At n C/ A lob Team Leader Date I / -.O , L Owner or Owndi's Delhiee, Titlb ""..CERTIFICATE OF INSERVICE INSPECTION I I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georcia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 09/14/05 to ._p JbD.,. rp. and state that to the best of my knowleclge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section !Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer slall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this in;Wi..g .Commissions C,_ , lv-Kspectds Signature National Board, State, Province and Endorsements Date 7 A-rAe,= ._2n-1, "lr~ve L~r of 3 FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS*As Required by the Provisions of the A&#xfd;ME Code, Section 111, Division 1 1 Pg. I of;i 2 AEOI COPRAIN 4 21MR YPI 1. Manufactured and certified by AERFI COPRTO,4y1MRA LC .LN~uG A 245(3n ;ins ne and laddrssa o.f N Certificael Meow)fl.Manufactured for GEORGIA POWER COMPANY, VOGTLE PLANT. WYEBR.G (,ame nd address of Putchaserl
: 3. Location of installation GEORGIA POWER COMPNAY, VOGTLE PLANT, WAYNESBORQ.
GA (name and addrmes)4. Type: HORIZONTAL HEAT EXCHANGER 970801 -N-C-1042 863 1997 (heMn. or von.) (tank. Jacketed, heat ox.) (Can. Nolder's serial no.); (CRN) (drawing no.1 (Nat'l. Od. no.] (year bit 5. ASME Code, Section I1l, Division 1: 1977 WINTE 1977 2 (edition) ladd Oda dales) clueis aCode Case no.)Items 6-10 inclusive to be completed for single wall vessels, jackets of jackel. d vessels, or shells of teat exchangers.
: 6. Shel:-SB-466'AL'706 38,000 .280" .051" 0' -2.3" i 31 -5.75" (mst'l. Spec. no.) itgsll. suervithl norn. thickness (in.ll ("on. design thickness (In.)l Idie. (O (ft & In.)l (length (overeal)
Wft& In.1)7. Seams: ........ --... 1;(long.) (HI") (RT) %efI. %l (gnh) (HI') (RT) I Ino. of CouW ea 8. Heeds:SB-171, AL.706 40,000 i ..[Hal meatl. spec. no.1 (tensile strength) flai met'l, seac. no.1 ios"e ngthW, Location Crown Knuckle EfllpHd4 Conical Hemispherical Flet Side to Proaauro (top. bottom. endel Thickness Radius Radius Ratio Apex Angie Radius Olarneter (conven of concaive)(a) END5 .62" FLAT -- --!2.3"1 FLATi It rem ovable, bolts used __ _ _ _ _ _ _ _Spec._ no.._size.
_ _ _ _ _ _ _ _ _ _ Other fastening (describe or attach sketch)9. Jacket closure: 0ascribe a sa agse & weld. bar. etcL If asr. give
.deocribe or sketch)lesign pressure 2  200 at max. temp. 300 Min. pressure-test tmp. Pneu.. hydro., or comb. test pressure (Doal) (FI (P) (psi)Items 17 and 12 to be completed for tube sections.11. Tubesheets:
Istationery.
mat'l. spec. no.) [die. in. [subject to pra. esetll Ithickness (in.] -lehchrrint (welded. boltedil (flostlna.
marl. Spec. no.) olie. Iln.i' Ithicknes (ln.iI iatcachment, 12.. Tubes: SB-111,AL.706
,625" .035" 324 ' STRAIGHT itti. Spec. no.1 t0o uOn.(thicness( i is orgel .(no.) Ijpe tralght or Ul11 Items 13 to 16 inclusive to be completed for inner chambefs of iackered weasirls; or channels of heat exchangers.
: 13. Shell: n e mat'l, spec. no.) (tensile strengthl Inon. thickness lin.11 1 in. deaign thickness (In.W (die. 10 Ift. & in.)l Ioangth loverall)
Ift & in.)l.14. Seams: (long. (welded. dbl.. singlel (HI" (yes or noil (AT) (eft. %l Igirthl IMT") IRTf Ino. of cou;rses)15. Heads: lia) mat'l. soec. no-.I (tensile strengtth) fibI mat'l. Spec. no.1 ltensile strength) lIdl met'l. spec. no.-I (tonsdl strangthl Crown Knuckle Elliptical Conical Hemisoherical Filt Side to Pres8re Location Thickness Radius Radius Ratio Apex Angle Radius olameter (convex or concavil (a) Top, bottom, ends (bW Channel (c) Floating removable, bolts used _________________________________Other fastening (mhal. Spec. no.. sid,. quantitl; Idaedci 5 or attach sktac!hl 16. Design pressure 2  a~at ._ .Min. pressure-test temp. Pneu., hydro., or comb. test pressure earil (oF) lOF) fp il'If poatweld heat treated. 'Ust other internal or external pressure with Coincident temperature when polcabIle.
' Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is aY' x 11. (2) information in items I through 4 on this Data Report is includled on each sheet. (3) each sheet is numbered and number of sheets is recorded at too of this form.1121881 This form (E00038) may be obtained from the Order Oept.. ASME. 22 Law Drive. Box 2300, Fairfield.
NJ 07007-2300.
 
# 05103 FORM N-1 (Back -Pg. 2 of S...) hee.t 3 3 Certificate Holder's Serial No-- 970801., -: -.: * .. ,. , 17. Nozzles, irispectiion and safety valve'openings Purpoase (inlet. How ..Reinforcement outlet. drain. etc.) Quentity " Die. or Size": Type Attached .. Mat'i. Thickness Material Location INLET/OfTLEr 1/1 2%?' -STUBE I Z MED:F .sB-s:4 .8" .. N/R EN_N.Jr. Fjm-r ./1 22.1. 15U. LS .N/R- END": _..:r 21 PUT'. I- .-.' 715 TB. Wig- .N. T I__X"_______ 2 1" PIPE -r.L -."- : ... .2&sect;"- 7. ./ END !'18.Spors Skirt "-- ... -L ---....18. Supports:
Skirt NI 19. Remarks: EOI Lugs -- Legs.....
Other -" Attached -Iquant=t-in
'." .quantlitv)
IdIcribel SO# 972676Q01,:.
.. -... ..-.- .:-. .:.(where & howl I rJ" BeliS OF SB-1. AL.706..:625" O.D.., .049!' NCI. Th:RMXNESS PR:R TO*'8BM'm/x MSf 71- Al-,_A" i-,............................
.. .. ... " .. ' ..... .**"-"' T: : .... .: " .-Design specification cei Design report. certified-"ON OF DESIGN, _--_'' ..14723i D AP I L L. STE B'I -... ..... .. t{.."G
..DtifReA W by P.E. Sta.e Rag. no.by , _DR. JOHN ROLAND'YOW
-:.-. State ."VA Reg. no. 6953......-' .........
... "? -- " CERTIFICATE OF.SHOP"COMPLIANCE-" ..... ...... ..I...............................................................
.................
,....... ... ,......We certify that the. statements..mada.in this. report are-correct and that this nuclear veU0el c'nfohs'to the rules for co nstriu'C*ction of.the ASME.Code, Section 1II, Division 1 .. .. .. .... ...... ....... .... .N Certificate.of ' N-2814 "" p M3/.-.Z'- -7 .....RPORATION.._-
-.p-__-RH3 1999 I--... .. iwcartificat.
Hbi~ri (authbr(zad rapreaentati,.e).
---I I-...".... .... ' .CERTIFICATE..OF SH&f iI-JPdTi'6N I, the un&#xfd; rsigned, holding a valid commission issued b the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by u*LLENDALE MUTUAL INSURANCE
.... "". .-0 a4y NORWOOD, MA have inspected the component described in this Data Report on , and state that to the best of my knowledge and belief, the Certificate Holder has constructed-this component-in'ad-cordance withthe ASME Coi&aiSection.lll, Division 1i.'. " .'By signing this certificate neither the inspector
=is er loyer makes any warranty, expressed or impled. concerning..the component-.described in this Data'RepOit:
Fufthermlriore.
neither thqr"or his'eiFployer shall be liable in any manner for any personal injury or-property.
damage or loss o y ndasing from or o t nsec Dates A "Sighed .Commissions " 7 -..4 .i * " IPTY4TA ~ Au tMhor pclor) INat'l 8 d. p-v and~' hoV"* ER-1 4 ICATE OF FIELD ,ASSEMBLY COMPLIANCE We certify that the statements on this report are correct and that the field assembly construction of all parts.of this. nuclear-.vessel-conforms to-the-ules of conSftN3l&ib of thb ASME Section III; Division I ... ..14 Certificate of Authorization No. Expires .. ... * .... -Date. .. ..... Signed IN Certificate Holder)fautnorized rep:resenteaivel i.CERTIFICATE OF FIELD ASSEMBLY INSPECTION.....
.the undersigned, holding a valid"-ommission issued b.y, thle- National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by -'' ""_ of ..... _-___' have compared the statements in this Data Rept wth the c mone.Riiptwt h escribed.copoett snd state that pans refer'red to-as data item&#xfd;s 7. .., not in.cluded in tb. certificate.of.s hop nspection.
he[e been ins 'cied by-'reon -- and that to the best of my knowledge and belief the Certificaqte.Holder.has constructed and component in accoidance wit~ thhe ASME"ode, Section III, Division 1.By signing this certificate neither the inspector nor. his employer makes any warranty, expressed or implied, concerning the qo..pjonent described n this Data Repori. -urthermore, naeihhe'r the inspector nor his employer shall be liable ih'ariy manner for iny personal injury or property damage or 3 loss of any kind arising from or connected with this inspection.
....:)ate. "_.__"S__n____":_"_"_"_" __' __" _._ ........._ -.___ .. .Commissions (Authorized Inseectorl INat'l. 8d. find. endoreementl) and state of piov. &Ad no.M ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 51 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, BirminGham.
AL Date Sheet Traveler#
05105 November 2, 2005 1 of 2 2040202501 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Unit Address Repair Organization P.O. No., J ob No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1201 /Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Summer 1972 Addenda, N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 19&9 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)REACTOR COMBUSTION 7372 22004 2-1201-V6-001 1979 REPLACEMENT YES VESSEL ENGINEERING
: 7. Description of Work Replaced studs at locations
#2 and #26.I 8. Test Conducted:
: 9. Remarks See Item 7 Hydrostatic
[0 Pneumaticlo Nominal Operating Pressurelc Other M Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of A horization No. N/A Expiration Date N/A Signed Z..Zl. Team Leader Date Owner geHwner's Deeinese Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by Hanford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartfrd.Connecticu have inspected the components described in this Owner's Report during the period September 26, 2005 to &4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i. & .a Commissions 60' 751o; nisfctqZ Signature National Board, State, Province and Endorsements Date__ I(1 y?/aoo a ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi Traveler#
05106 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet Unit 10/14/05 1 off 2 WO# 2052761801 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Address Type Code Symbol Stamp Authorization No.Expiration Date 1301/Main Steam System N/A N/A N/A 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section XI Utilizedfor Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1301-107-H002 1989 REPLACEMENT YES SUPPORT PRODUCTS 7. Description of Work Snubber AD-5503, serial #236 was replaced with an AD-5503 serial #436 to support surveillance testing.8. Test Conducted:
Hydrostatic 5 Pneumatlc[]
Nominal Operating Pressure[N/A [J Other 5 Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Team Leader Date /- a Owner r Owner's Designee, Title 010 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the Siate or Province of Georgia and employed by --Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartfor Connecticut have inspected the components described in this Owner's Report during the period 09/27/05 to ! and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code, Section! Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning
:the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer sahall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions
&  SSignature National Board, State, Province and Endorsements Date _ _L_ ________
I -..ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI ym1 Traveler#
05107@ 1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birminqham.
AL Date Sheet Address 2. Plant Vogtle Electric Generating Plant November 1, 2005 tof 1 2 2052707701 Unit Name Waynesboro, GA 30830 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1501 / Containment Air Cooling (ESF)5. (a) Applicable Construction Code ASME SEC III 19 74 Edition, Summer 1975 Addenda, N/A (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component I Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPING PULLMAN N/A N/A 2-1501-PIPE 1989 REPLACEMENT YES SYSTEM POWER 7. Description of Work Replace studs and nuts on piping flanges identified as JT-8 on isometric drawing 2V4-1501-032-01.
: 8. Test Conducted:
WAIa 9. Remarks See Item 7 Hydrostatic (a Pneumatic[o Nominal Operating Pressure [a Other [[ Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE-OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Team Leader Date d A 0 Of r or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geomia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hanford go ci av inspected the components described in this Owner's Report during the period September
: 27. 2005 o0 f and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Ins&#xfd; &#xfd; , kl.-- Commissions C-Z& :Z"4 Signature National Board, State, Province and Endorsements Date 1~/
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI"7.1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit Traveler#
05114 October 24, 2005 1 of 2 2040095901
: 2. Plant Address Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1208 / Chemical and Volume Control System 5. (a) Applicable Construction Code ASME SEC Il1 19 74 Edition, Summer 1975 Addenda, N/A (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19&9 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPING PULLMAN N/A N/A 2-1208-PIPE 1987 REPLACEMENT YES SYSTEM POWER 7. Description of Work Replaced studs and nuts at flange.0 8. Test Conducted:
WA[M Hydrostatic
[] Pneumaticr[[
Nominal Operating Pressure [0 Other [a Pressure N/A PSI Test Temp. N/A 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Cede, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of ,uthorization No. 7 N/A Expiration Date N/A Signed / Team Leader Date 8 Ownprbor OCw ner'dDbsignee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georala and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Harto Connticut have inspected the components described in this Owner's Report during the period October 3. 2005 to &LX and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions C7 76(p An 4~spaor's Signature National Board, State, Province and Endorsements Date 6 ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS.OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
05116 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham.
AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet Unit 08104/06 1 of 2 WO# 2050207701 and PO# 7057873-0004 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plnt Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1201 /Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Winter 1972 Addenda, N/A Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped;Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NoL SAFETY CROSBY VALVE & N56964-00-0041 NA 2PSV-8010A 1976 REPLACEMENT YES VALVE GAGE CO.7. Description of Work Safety valve was replaced with a rotating spare to support setpoint testing. The replacement valve set pressure and seat leakage acceptability were certified by Wyle Laboratories under PO# 7057873-0004 prior to installation.
: 8. Test Conducted:
Hydrostatic j] Pneumaticr]
Nominal Operating PressureE' NIA fl Other [ Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Team Leader Date LJ Owner or DOwner's Titig!CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georqia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut i of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 10/08105 to Zi /4'i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report In accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning
'the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this (. Commissions 4jr.I-... ~ lngpector's-.nature National Board, State, Province and Endorsements Date 1.
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler #05117 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 08/04/06 1 of 2 Address 2. Plant Vootle Electric Generating Plant Unit Name Waynesboro, GA 30830 Address WO# 2050207701 and PO# 70578r730004 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voatle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1201 /Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Winter 1972 Addenda, N/A (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped, Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)SAFETY CROSBY VALVE & N56964-00-0036 N/A 2PSV-80OB 1976 REPLACEMENT YES -VALVE .GAGE CO.7. Description of Work Safety valve was replaced with a rotating spare to support setpoint testing.,The replacement valve set pressure and seat leakage acceptability were certified by Wyle Laboratories under PO# 7057873-0004 prior to installation.
I S. Test Conducted:
NIA 9. Remarks See Item 7 Hydrostatic C] Pneumatic[]
Nominal Operating Other F] Pressure N/A PSI Test Temp. N/A Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of tIie ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed onQr Team Leader Date Tt I (jvjner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford Connecticut have inspected the components described In this Owner's Report during the-.period 10/08/05 to 47 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this netorG d"Atur AZ -NationCommissions 6d to gatr National Board, State, Province and Endorsements Date_______
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Traveler#
05118 08/04/06 of 1 2 Address 2. Plant Voqtle Electric Generating Plant Unit Name Waynesboro, GA 30830 WO# 2050207701 and PO# 7057873-0004 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by _4. Identification of System Maintenance Department Name Plant Vogtle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address 1201 /Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Winter 1972 Addenda, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components N/A Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped.i Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)SAFETY CROSBY VALVE& N56964-00-0042 N/A 2PSV-8010C 1976 REPLACEMENT YES I VALVE GAGE CO.7. Description of Work Safety valve was replaced with a rotating spare to support setpoint testing. The replacement valve set pressure dnd seat leakage acceptability were certified by Wyle Laboratories under PO# 7057873-0004 prior to installation.
: 8. Test Conducted:
Hydrostatic
[] Pneumatic-]
Nominal Operating Pressure[]
N/A [] Other [] Pressure N/A PSI Test Temp. N/A F 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date N/A Signed L23 Team Leader Date 911(2'-1o Owner or Owner's CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford Connecticut have inspected the components described In this Owner's Report during the period 10/08/05 to state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section j Xl.By -signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning "the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this 5itA1 A&&eZ1 Commissions 1 47-'4&#xfd;&#xfd; Indoector'W9nature National Board, State, Province and Endorsements Date ae ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI y'1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit Traveler#
05119 11/14/05 1 of 1 2 WO# 20201100 and PO# 7038335 WO# 2040232301 and PO# 7056205 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by Westinghouse Electric Co.Name 44 Inverness Center Pwy., Suite 148, Birmingham, AL 35242 Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A 4. Identification of System 1201 / Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC I// 19 71 Edition, Winter 1972 Addenda, N/A (b)Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PUMP WESTINGHOUSE 2-9744D35G01 24 2-1201-P6-001 1986 REPLACEMENT YES ELECTRIC CORP.7. Description of Work This NIS-2 documents a prior replacement activity per CR# 2004002230.
The number 2 seal housing S/N 2026 is currently installed on this pump. The number 2 seal housing S/N 2026 was installed under WO# 20201100 and PO# 7038335. The serial number was verified and documented under WO# 2040232301 and P01# 7056205. The number 2 seal housings are utilized as rotating spares (part of the seal cartridge assembly) and may be installed on any of the Unit 1 or 2 reactor coolant pumps.8. Test Conducted:
Hydrostatic
[3 Pneumatic[]
Nominal Operating Pressure[']
N/A fl Other [] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed 04.,#' .'/ Team Leader Date Ownelror Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 11/08/05 to _1and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions G , 7K.
Signature
' National Board, State, Provinceand Endorsements Date _____________
I!ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#05120 I 1. Owner Southem Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 1 1/14/05 1 Of 2 Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Unit WO# 20400606 and PO# 7056205 WO# 2040232701 and PO# 7056205 Repair Organization P.O. No., Job No., etc.3. Work Performed by Westinghouse Electric Co.Name 44 Inverness Center Pwy., Suite 148, Birmingham, AL 35242 Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A 4. Identification of System 1201 /Reactor Coolant Svstem 1201 / Reactor Coolant Svstem 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Winter 1972 Addenda, (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components N/A Code Case I National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedi Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PUMP WESTINGHOUSE 4-9744D35G01 26 2-1201-P6-002 1986 REPLACEMENT YES ELECTRIC CORP._ _7. Description of Work This NIS-2 documents a prior replacement activity per CR# 2004002230.
The number 2 seal housing SIN 1622 Is currently installed on this pump. The number 2 seal housing SIN 1622 was installed under WO# 20400606 and PO# 7056205. The serial number was verified and documented under W0#2040232701 and PO# 7056205. The number 2 seal housings are utilized as rotating spares (part of the seal cartridge assembly) and may be installed on any of the Unit I or 2 reactor coolant pumps. I 8. Test Conducted:
Hydrostatic fl Pneumatic[]
Nominal Operating Pressurer j1 N/A E Other El Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached -CERTIFICATE OF COMPLIANCE
-We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate o Authorization No. N/A Expiration Date N/A T Signe- Team Leader Date Lge WuQner orG Gner s Designee, Title CERTIFICATE OF INSERVICE INSPECTIONaI I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 11/08/05 to 7./L.-lf a , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with !this Commissions 6 A ,1%.<ir, I":=.-.'iifbector'-ignature Natloil Board, State, Province and Endorsements Date /I_ _; N j "IP -
ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler #05121 I I 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet 11/14/05 1 of 2 Address 2. Plant Vogtle Electric Generating Plant Unit Name Waynesboro, GA 30830 WO# 20200140 and PO# 7038335 WO# 2040233301 and PO# 7056205 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by Westinghouse Electric Co.Name 44 Inverness Center Pwy., Suite 148, Birmingham, AL 35242 Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A 4. Identification of System 1201 / Reactor Coolant Svstem 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Winter 1972 Addenda, N/A (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped!Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PUMP WESTINGHOUSE 3-9744D35G01 25 2-1201-P6-003 1986 REPLACEMENT YES I ELECTRIC CORP. _7. Description of Work This NIS-2 documents a prior replacement activity per CR# 2004002230.
The number 2 seal housing SIN 2020 is currently installed on this pump. The number 2 seal housing SIN 2020 was installed under WO# 20200140 and P01# 7038335. The serial number was verified and documented under WO# 2040233301 and P01# 7056205. The number 2 seal housings are utilized as rotating spares (part of the seal cartridge assembly) and may be installed on any of the Unit 1 or 2 reactor coolant pumps.8. Test Conducted:
Hydrostatic
[] PneumaticE Nominal Operating Pressure[A]
N/A Other E] Pressure N/A PSI Test Temp. N/A OF 9. Remarks -See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date A Signed &_/7 TeamLeader Date Ownd4 or Owner'siDe&sect;ilnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut I of Hartford, Conpecticut have inspected the components described in this Owner's Report during the period 11/08/05 to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report, in accordance with the requirements of the ASME Code, Section' Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall-, ... I be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inetjI >Jr. " Commissions fAo D"at-e. sre ctoWSignature National Board, State, Province and Endorsements 4 ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler4 05122 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit 11/14/05 1 of 2 Address 2. Plant Voptle Electric Generating Plant Name Waynesboro, GA 30830 WO# 20001295 and PO# 7038335 WO# 2040233601 and PO# 7056205 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by Westinghouse Electric Co.Name 44 Inverness Center Pwy., Suite 148, Birmingham, AL 35242 Address Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A 4. Identification of System 1201 / Reactor Coolant System 5. (a) Applicable Construction Code ASME SEC III 19 71 Edition, Winter 1972 Addenda, N/A (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components Code Case National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedi Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or NOL PUMP WESTINGHOUSE 1-9744D35G01 23 2-1201-P6-004 1986 REPLACEMENT YES ELECTRIC CORP.7. Description of Work This NIS-2 documents a prior replacement activity per CR# 2004002230.
The number 2 seal housing S/N 1830 is currently installed on this pump. The number 2 seal housing S/N 1830 was installed under WO# 20001295 and PO#7038335.
The serial number was verified and documented under WO# 2040233601 and PO# 7056205. The number 2 seal housings are utilized as -rotating spares (part of the seal cartridge assembly) and may be installed on any of the Unit I or 2 reactor coolant pumps. I 8. Test Conducted:
Hydrostatic
[J Pneumatic[]
Nominal Operating Pressure-X N/A [] Other I] Pressure N/A PSI Test Temp. N/A OF 9. Remarks See Item 7 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of A thorization No. N/A Expiration Date N/A T Signed ("Ovner Team Leader Date Owner joOwner's Designee, Titlef CERTIFICATE OF INSERVICE INSPECTION 1 I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georoia and employed by __.Hartford Steam Boiler Inspection and Insurance Co. of Connecticut I of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 09/28/05 I to _ and state that to the best of my knowledge and belief, the Owner has performed examinations and tiken correctlve-"Measures described In this Owners Report in accordance with the requirements of the ASME Code, Sectioni XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with Ithis Ins Commissions 67* 7'rT.lctofflSignature National Board, State, Province and Endorsements Date I I FORM NIS-2 OWNER'S RE IFNIAL REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
06032 41 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Date Sheet Unit Ap41 10, 2006 1 1 of I 2 Address 2. Plant Vogte Electric Generating Plant Name Waynesboro, GA 30830 2060273601 Address Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogt/e Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address .1204 /Safetv Iniection 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Code Cas eI 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedl Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE SUPPORT PULLMAN N/A N/A V2-1204-023-H002 1989 REPLACEMENT YES POWER 7. Description of Work Snubber AD -1601, serial#146 was replaced with AD-1601 seial #649 to support forced outage 8. Test Conducted:
N/A[-9. Remarks See Item 7 Hydrostatic
[a Pneumatic[C-Nominal Operating Pressurel[E3 Other [0 Pressure N/A PSi Test Temp.- N/A Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A.Certificate of Authorization No. N/A Expiration Date N/A -Signed Team Leader Date 0 S _ I Owner or Owner's Designee, Tit CERTIFICATE OF INSERVICE INSPECTION
[I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the State or Province of Geormia and employed by Harfford Steam Boiler Inspecfion and Insurance Co. of Connecticut of Hartfdrd Connecticut have inspected the components described in this Owner's Report during the period February 11, 2006 1 to -0 ,- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken correct ive measures described in this Owners Report in accordance with the requirements of the ASME Code, Section IXI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i Commissions
_,. 74 SSnNational Board, State, Province and Endorsements Date _________a FB/I v ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Traveler#
07d Dl03.1.Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway..
Birmingham, AL Date Sheet Unit 04112/07 of 2* ir. y -Address 2. Plant Vogtle Electric Generating Plant Name* Waynesboro, GA 30830 Address WO# 2061450101 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4.. Identification of System Maintenance Department Name Plant Voptle Type Code Symbol Stamp Authorization No.Expiration Date N/A NAV NIA Address 1301/Main Steam System 5. (a) Applicable Construction Code ASME SEC III 1977 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedl Component Manufacturer Serial No. No. Identification.
Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1301.128.H075 1989 REPLACEMENT YES I SUPPORT PRODUCTS 7. Description of Work SnubberAD-151L, seial #487 was replaced with a snubberAD-151L, serial #707 to support surveillance testing. I 8. TetCnutd 8. Test Conducted:
WAN 9. Remarks See Item 7 Hydrostatic
[] Pneumatic[]
Nominal Operating PressureE]
Other [] Pressure N/A PSI Test Temp. N/A OF Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed " ( Lj) .. Team Leader Date 41l 1 107\ I Owner or Owner's Designree, Title pf CERTIFICATE OF INSERVICE INSPECTION f I, the undersigned, holding a valid commission Issued by the national Board of Boiler and Pressure Vessel Inspectors and the Slate or Province of Georqia and employed by Hartford Steam Boiler and Insurance Co. of Connecticut I of Hanford. Connecticut have Inspected the components described In this Owner's Report during the period .01/22/07
: to -.... and state that to the best, of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inwasadon.
Commissions , r.njector's Signature Natlo~na[-Boerd, State, Province and Endorsements Date AP.&L 1.1I ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi 07017 Traveler#04/12/07 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant .Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet Unit 1 of 1 2 WO# 2061451701 Repair Organization P.O. No., Job No., atc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voptle Type Code Symbol Stamp Authorization No.Expiration Date N/A NAV I N/A Address 1205 / Residual Heat Removal Svstem 5. (a) Applicable Construction Code ASME SEC ItI 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Cas (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components B National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampedj Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1205-007-H019 1989 REPLACEMENT YES SUPPORT PRODUCTS._
_7. Description of Work Snubber AD-1603, serial #656 was replaced with a snubber AD-1603, serial #368 to support surveillance testing.8. Test Conducted:
WAN 9. Remarks See Item 7 Hydrostatic
[] PneumaticE Nominal Operating Pressure J Other [] Pressure N/A PSI Test Temp. N/A Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A I Signed wnr .Team Leader Date Owner or OwneresDesignee;, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Board of Boiler and Pressure Vessel Inspectors and the-State or Province of Georgia and employed by -Hartford Steam Boiler InsOection and Insurance Co. of Connecticut of Hartford.
Connecticut have Inspected the components described in this Owner's Report during the period 101/22107 to !J. 1., 2 .AR , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners- Report In accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ins __________
___________-
_ Commissions (9t. "(..fnspectfs Signature National Board, State, Province and Endorsements Date A',PPJL L 4 2&57 ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl&#xa3;1 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Traveler#
07080 04/12/07 I of 1 2 Sheet Unit WO# 2070465601 Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vogtle Address Type Code Symbol Stamp Authorization No.Expiration Date NAV NAV N/A 1201 / Reactor Coolant System 1201 / Reactor Coolant Svstem 5. (a) Applicable Construction Code ASME SEC III 19 77 Edition, Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Repiacements 1989 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stampeds Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)PIPE PULLMAN POWER N/A N/A V2-1201-029-H603 1989 REPLACEMENT YES SUPPORT PRODUCTS _7. Description of Work Snubber AD-501, serial #546 was replaced with a snubber AD-501, serial #675 to support surveillance testing. I 8. TetCnutd 8. Test Conducted:
: 9. Remarks See Item 7 Hydrostatic
[] Pneumatic[]
Nominal operating Pressure]e Other n Pressure NIA PSI Test Temp. NIA OF ,.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE ie We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed oo,.-oA Team Leader Date 6 Owner or Owner's Designee, ?Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the Slate or Province of Georgia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford.
Connecticut have Inspected the components described in this Owner's Report during the period 03/15/07 to Y J1OO7 ,'and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section! Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning
'the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insas~bn_~- _ __r , A- Commissions 7 St."---""Inspe-"r Signature National Board, State, Province and Endorsements Date AMuP.L A. 1 7 i 4 ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi 9 Traveler#
07082 04/12M07 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birmingham, AL Address 2. Plant Vogtfe Electric Generating Plant Name Waynesboro, GA 30830.Address Date Sheet 1 of 1_ _Unit 2 2 wna on7nAg"ni I Repair Organization P.O. No., Job No., etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Vootle Type Code Symbol Stamp Authorization No.Expiration Date N/A N/A N/A Address.1301 /Main Steam System 5. (a) Applicable Construction Code ASME SEC /II 19 77 Edition,.
Winter 1977 Addenda, N-249-1 Code Case (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 19ag I 6. Identification Of Components Repaired or Replaced and Replacement Components Y Y Name of Manufacturer I I Manufacturer Nations Board No.7. Description of Work Snubber AD-503, serial #207 was replaced with a snubber AD-503, serial #221 to support surveillance testing.8. Test Conducted:
Hydrostatic
[] Pneumatic[]
Nominal Operating Pressure[]
N/A [] Other [ Pressure N/A PSI Test Temp. N/A OF 9. Remarks. See Item 7 Applicable Manufacturer's Dats Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this ASME Code, Section Xl. rel replacement conforms to the rules of tie pair or replacement 4 Type Code Symbol Stamp Certificate of Authorization No.Signed .(_N/A N/A Expiration Date Team Leader Date '__________
-Il Owner nr flwnar'a flnelnnaalTltIa CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the national Board of Boiler and Pressure Vessel Inspectors and the StLate or Province of Georia-
* and employed by Hartford Steam Boiler Insoection and Insurance Co. of Connecticut of Hartford.
Connecticut have Inspected the components described in this Owner's Report during the period 03/15/07 I to &-.17_-&#xa2;ig, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section 1XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from *or 'connected with this Ins_____________________Commissions C.34. ylr National Board, State, Province and Endorsements I Data
., o)r j ORIGINAL FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Cods Section Xl 07088 Traveler #04/12/07 1. Owner Southern Nuclear Operating Company Name 40 Inverness Center Parkway, Birrningham, AL Address 2. Plant Vogdtle Electric Generating Plant Name Waynesboro, GA 30830 Address Date Sheet 1 of 1 Unit 2 WO# 2070466401 Repair Organization P.O. No., Job No.; etc.3. Work Performed by 4. Identification of System Maintenance Department Name Plant Voqtle Type Code Symbol Stamp Authorization No.Expiration Date N/A W/A N/A Address 1204/ Safely Injection System , 5. (a) Applicable Construction Code ASME SEC Ill 19 77 Edition, Winter 1977 Addenda, N-249.1 Code Case (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1982 6. Identification Of Components Repaired or Replaced and Replacement Components National Repaired, ASME Code Name of Name of Manufacturer Board Other Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement "Yes or No)PIPE PULLMAN POWER N/A N/A V2-1204-246-HOOI 1989 REPLACEMENT YES SUPPORT PRODUCTS _7. Description of Work Snubber AD-43, serial #1513 was replaced with a snubber AD-43, serial #513 to support surveillance testing.8. Test Conducted:
NA1 9. Remarks See Item 7 Hydrostatic pPneumaticE Nominal Operating Pressurte[
Other[] .Pressure NIA PSI Test Temp. NAII Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this replacement conforms to the rules of the ASME Code, Section Xi. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed .A,' (A- _ _ Team Leader Date V Owner or Owner's Designee, tritle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the national Boaird of Boiler and Pressure Vessel Inspectors and the State or Province of Geormia and employed by Hartford Steam Boiler Inspection and Insurance Co. of Connecticut of Hartford.
Connecticut have inspected the components described In this Owner's Report during the period .03/15/07 I to 44 -IV -,k=7 , and state that to the best of my knowledge and belief, the Owner has performed.
examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section x,.By signing this certificate, neither the Inspectoi nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Commissions CA 7CL .Inspector'signature National Board, State, Province and Endorsements Date APAL tt a007}}

Latest revision as of 05:43, 10 February 2019