ENS 46379: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 10/29/2010 16:21 CDT | | event date = 10/29/2010 16:21 CDT | ||
| last update date = 10/29/2010 | | last update date = 10/29/2010 | ||
| title = Degraded Condition - 71% Through Wall Indication | | title = Degraded Condition - 71% Through Wall Indication on Reactor Recirc Nozzle | ||
| event text = Information from a Phased Array UT [Ultrasonic Testing] examination of RRA-F002A indicates that a linear indication 6.5" long and a maximum depth of 71 % through wall extent (ID [Inner Diameter] connected) exists. The Phased Array UT examination of RRA-F002A was performed as part of scheduled outage activities. | | event text = Information from a Phased Array UT [Ultrasonic Testing] examination of RRA-F002A indicates that a linear indication 6.5" long and a maximum depth of 71 % through wall extent (ID [Inner Diameter] connected) exists. The Phased Array UT examination of RRA-F002A was performed as part of scheduled outage activities. | ||
TRM [Technical Requirements Manual] LCO [Limiting Condition for Operation] 3.7.3 for Structural Integrity, Condition B has been entered for the Recirc nozzle/piping. | TRM [Technical Requirements Manual] LCO [Limiting Condition for Operation] 3.7.3 for Structural Integrity, Condition B has been entered for the Recirc nozzle/piping. |
Latest revision as of 22:08, 1 March 2018
Where | |
---|---|
Duane Arnold ![]() Iowa (NRC Region 3) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
LER: | 05000331/LER-2010-004 |
Time - Person (Reporting Time:+-0.37 h-0.0154 days <br />-0.0022 weeks <br />-5.06826e-4 months <br />) | |
Opened: | Dick Fowler 20:59 Oct 29, 2010 |
NRC Officer: | Dong Park |
Last Updated: | Oct 29, 2010 |
46379 - NRC Website
| |