Line 16: | Line 16: | ||
| event date = 07/24/2015 CDT | | event date = 07/24/2015 CDT | ||
| last update date = 07/24/2015 | | last update date = 07/24/2015 | ||
| title = Texas Agreement State Report - Unable | | title = Texas Agreement State Report - Unable to Retract Radiography Camera Source | ||
| event text = The following information was obtained from the State of Texas via email: | | event text = The following information was obtained from the State of Texas via email: | ||
On July 24, 2015, the Agency [Texas Department of State Health Services] was notified by the licensee's radiation safety officer (RSO) that one of his crews was unable to retract a 39 curie Iridium-192 source into QSA 880 D camera. The RSO stated the radiographers had completed their first shot of the day in a shooting bay and noted the lock on the camera did not trip when the source was retracted. The RSO stated the radiographers noted the dose rate where they were standing was 30 millirem per hour after they attempted to retract the source. The radiographers notified the RSO of the event. The RSO responded to their location. The RSO is authorized to recover disconnected sources. | On July 24, 2015, the Agency [Texas Department of State Health Services] was notified by the licensee's radiation safety officer (RSO) that one of his crews was unable to retract a 39 curie Iridium-192 source into QSA 880 D camera. The RSO stated the radiographers had completed their first shot of the day in a shooting bay and noted the lock on the camera did not trip when the source was retracted. The RSO stated the radiographers noted the dose rate where they were standing was 30 millirem per hour after they attempted to retract the source. The radiographers notified the RSO of the event. The RSO responded to their location. The RSO is authorized to recover disconnected sources. |
Latest revision as of 21:47, 1 March 2018
Where | |
---|---|
Texas Qa Services, Inc. Grand Prairie, Texas (NRC Region 4) | |
License number: | L04601 |
Organization: | Texas Dept Of State Health Services |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+6.83 h0.285 days <br />0.0407 weeks <br />0.00936 months <br />) | |
Opened: | Art Tucker 11:50 Jul 24, 2015 |
NRC Officer: | Howie Crouch |
Last Updated: | Jul 24, 2015 |
51258 - NRC Website | |