The license number was originally reported as 373525501 but it should actually be 16-35383-01. Unit is 10 feet above the floor not 20 feet.  Survey readings have been taken: 25.65 mR/hr at the surface;  1.73 mR/hr at 1 foot; 0.32 mR/hr at 3 feet; 0.05 mR/hr at 4 feet. Based on the survey readings, it is believed that the shutter is closed. The mine is now looking to repair the shutter control unit, not replace the gauge.   
The license number was originally reported as 373525501 but it should actually be 16-35383-01. Unit is 10 feet above the floor not 20 feet.  Survey readings have been taken: 25.65 mR/hr at the surface;  1.73 mR/hr at 1 foot; 0.32 mR/hr at 3 feet; 0.05 mR/hr at 4 feet. Based on the survey readings, it is believed that the shutter is closed. The mine is now looking to repair the shutter control unit, not replace the gauge.   
Notified R1DO (Young) and NMSS Events via email.
Notified R1DO (Young) and NMSS Events via email.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2024/20240517en.html#en57121
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2024/20240520en.html#en57121
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 06:26, 23 May 2024

ENS 57121 +/-
Where
Screaming Eagle Coal
Bickmoore, West Virginia (NRC Region 1)
License number: 16-35383-01
Organization: Screaming Eagle Coal
Reporting
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure
Time - Person (Reporting Time:+16.25 h0.677 days <br />0.0967 weeks <br />0.0223 months <br />)
Opened: Brandt Elkens
08:15 May 10, 2024
NRC Officer: Brian P. Smith
Last Updated: May 10, 2024
57121 - NRC Website