ENS 55874: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (StriderTol Bot insert) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
Line 25: | Line 25: | ||
There was and is no radiation exposure concern for Marathon Pipe Line LLC employees, contractors, visitors or the general public. | There was and is no radiation exposure concern for Marathon Pipe Line LLC employees, contractors, visitors or the general public. | ||
Vega Americas, Inc. has been contacted for a path forward to order and install a replacement device as well as develop a plan and assist in the safe removal, isolation and disposal of this gauge. | Vega Americas, Inc. has been contacted for a path forward to order and install a replacement device as well as develop a plan and assist in the safe removal, isolation and disposal of this gauge. | ||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2022/ | | URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2022/20220511en.html#en55874 | ||
}} | }} | ||
{{ENS-Nav}} | {{ENS-Nav}} |
Latest revision as of 07:30, 11 May 2022
Where | |
---|---|
Marathon Pipe Line Llc Indianapolis, Indiana (NRC Region 3) | |
License number: | GL-714799-27 |
Organization: | Marathon Pipe Line Llc |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+25.9 h1.079 days <br />0.154 weeks <br />0.0355 months <br />) | |
Opened: | Matt Grimes 15:24 May 3, 2022 |
NRC Officer: | Lloyd Desotell |
Last Updated: | May 3, 2022 |
55874 - NRC Website | |