After receiving the assay results confirming the source capsules had not been compromised, the Odessa RSO completed the removal of supports and clamps which secured the damaged densitometers to the equipment. Using a large crane, he removed the damaged densitometers, one at a time and placed both in a pre-designated area away from personnel.  Bags of barite were placed over the damaged densitometers to reduce dose rates throughout the operation.  The area was roped off and marked to keep anyone from entering.  Following the removal of the densitometers from the equipment the NexTier Corporate Radiation Safety Officer conducted a survey on and around the equipment using a Ludlum Model 3000 survey meter with a Nal scintillation detector.  No readings more than natural background were detected.
After receiving the assay results confirming the source capsules had not been compromised, the Odessa RSO completed the removal of supports and clamps which secured the damaged densitometers to the equipment. Using a large crane, he removed the damaged densitometers, one at a time and placed both in a pre-designated area away from personnel.  Bags of barite were placed over the damaged densitometers to reduce dose rates throughout the operation.  The area was roped off and marked to keep anyone from entering.  Following the removal of the densitometers from the equipment the NexTier Corporate Radiation Safety Officer conducted a survey on and around the equipment using a Ludlum Model 3000 survey meter with a Nal scintillation detector.  No readings more than natural background were detected.
Each densitometer contained 0.2 Curie of Cs-137.
Each densitometer contained 0.2 Curie of Cs-137.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2021/20211001en.html#en55485
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2021/20211004en.html#en55485
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 07:30, 4 October 2021

ENS 55485 +/-
Where
Nextier Completion Solutions, Inc.
Houston, Texas (NRC Region 4)
License number: GA 507-06
Organization: New Mexico Rad Control Program
Reporting
Agreement State
Time - Person (Reporting Time:+3317.4 h138.225 days <br />19.746 weeks <br />4.544 months <br />)
Opened: Michael Ortiz
10:24 Sep 24, 2021
NRC Officer: Mike Stafford
Last Updated: Sep 24, 2021
55485 - NRC Website