ENS 54872: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot change)
(StriderTol Bot change)
 
Line 1: Line 1:
{{ENS notification
{{ENS notification
| event number = 54872
| event number = 54872
| facility = Solvay Specialty Polymers Usa Llc
| facility =  
| Organization = Texas Dept Of State Health Services
| Organization = Texas Dept Of State Health Services
| license number = L06719
| license number = L06719
Line 10: Line 10:
| utype =  
| utype =  
| cfr = Agreement State
| cfr = Agreement State
| emergency class = Non Emergency  
| emergency class = Non Emergency
| notification date = 09/01/2020 11:03
| notification date = 09/01/2020 11:03
| notification by = Art Tucker
| notification by = Art Tucker
Line 16: Line 16:
| event date = 08/31/2020 00:00 CDT
| event date = 08/31/2020 00:00 CDT
| last update date = 09/01/2020
| last update date = 09/01/2020
| title = Agreement State Report- Shutter Stuck in Open Position  
| title = <Td Align="Left" Scope="Row">Agreement State Report- Shutter Stuck in Open Position
| event text = The following was received from the Texas Department of State Health Services (the Agency) via e-mail:  
| event text = The following was received from the Texas Department of State Health Services (the Agency) via e-mail:
On September 1, 2020, the Agency received a report from the licensee's radiation safety officer (RSO) indicating the shutter on an Ohmart Vega model SH-F1B nuclear gauge was stuck in the open position. Open is the normal operating position of this gauge. The gauge contains a 100 milliCurie (original activity) cesium-137 source. The stuck shutter was found during routine inspections. The licensee has contacted a service provider to repair the gauge. The gauge does not create an exposure risk to any individual. Additional information will be provided in accordance with SA-300.
On September 1, 2020, the Agency received a report from the licensee's radiation safety officer (RSO) indicating the shutter on an Ohmart Vega model SH-F1B nuclear gauge was stuck in the open position. Open is the normal operating position of this gauge. The gauge contains a 100 milliCurie (original activity) cesium-137 source. The stuck shutter was found during routine inspections. The licensee has contacted a service provider to repair the gauge. The gauge does not create an exposure risk to any individual. Additional information will be provided in accordance with SA-300.
Texas Incident Number: 9791
Texas Incident Number: 9791
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200910en.html#en54872
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200910en.html#en54872
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 12:22, 15 January 2021

ENS 54872 +/-
Where
Texas Dept Of State Health Services
Borger, Texas (NRC Region 4)
License number: L06719
Organization: Texas Dept Of State Health Services
Reporting
Agreement State
Time - Person (Reporting Time:+30.05 h1.252 days <br />0.179 weeks <br />0.0412 months <br />)
Opened: Art Tucker
11:03 Sep 1, 2020
NRC Officer: Thomas Herrity
Last Updated: Sep 1, 2020
54872 - NRC Website