{{Adams
#REDIRECT [[W3P85-1298, Forwards Rev 0 to 10-Yr Inservice Insp Program,Waterford Steam Electric Station Unit 3. Approval of Program & Relief from Testing Requirements of ASME Code Section XI Requested]]
| number = ML20128N764
| issue date = 05/28/1985
| title = Forwards Rev 0 to 10-Yr Inservice Insp Program,Waterford Steam Electric Station Unit 3. Approval of Program & Relief from Testing Requirements of ASME Code Section XI Requested
| author name = Cook K
| author affiliation = LOUISIANA POWER & LIGHT CO.
| addressee name = Knighton G
| addressee affiliation = NRC OFFICE OF NUCLEAR REACTOR REGULATION (NRR)
| docket = 05000382
| license number =
| contact person =
| document report number = W3P85-1298, NUDOCS 8506030380
| package number = ML20128N767
| document type = CORRESPONDENCE-LETTERS, INCOMING CORRESPONDENCE, UTILITY TO NRC
| page count = 1
}}
 
=Text=
{{#Wiki_filter:Louisiama / ,4.c.-o~o.-.1                    . o.ex.co.
P O W E R & L 1 G H T / N W 08%.ANS LeutStANA  70174-6008    G (504)3SS-2345 NIES  Y May 28, 1985 W3P85-1298 A4.05 Mr. G._W. Knighton, Chief Licensing Branch No. 3 Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555
 
==Dear Mr. Knighton:==
 
==Subject:==
Waterford 3 SES Docket No. 50-382 License No. NPF-38 TEN YEAR INSERVICE INSPECTION PROGRAM, REVISION 0
 
==Reference:==
License Condition 2.C.5 In accordance with 10CFR50.55a(g), " Inservice Inspection Requirements"and License Condition 2.C.5, Louisiana Power & Light Company hereby submits seven (7) copies of the Ten Year Inservice Inspection Program which is prepared in accordance with the ASME Code Section XI, 1980 Edition with Addenda through Winter 1981. Relief from the testing requirements of Section XI is requested when full compliance with the requirements of the code is not practical. In such cases, specific information is provided which identifies the applicable code requirements, justification for the relief request, and the testing method to be used as an alternative.
It is hereby requested that the subject Program be approved and the ASME Section XI code relief requested be granted pursuant to Section 50.55a(g)(6)(i) of 10CFR50.
Very truly yours,
                                                  /
K.W. Cook Nuclear Support & Licensing Manager KWC:BGM:sms Enclosure                8506030380 850528 PDR    ADOCK 05000382                                        IN 3                    PDR Attachment cc (w/o enclosure):      E.L. Blake, W.M. Stevenson, R.D. Martin, D.M. Crutchfield, J.H. Wilson, NRC Resident Inspectors Office}}