Line 21: | Line 21: | ||
The Radiation Safety Officer (RSO) was en route, and with guidance from the service company, will place the source in a bucket and fill it with sand, survey the area for any contamination, return the source to the facility for a leak test, and store the gauge. The RSO will determine how to dispose of the source and gauge once the leak test results are received. | The Radiation Safety Officer (RSO) was en route, and with guidance from the service company, will place the source in a bucket and fill it with sand, survey the area for any contamination, return the source to the facility for a leak test, and store the gauge. The RSO will determine how to dispose of the source and gauge once the leak test results are received. | ||
The technician was wearing dosimetry and it will be sent in for analysis. It is not expected that there was much additional exposure received. | The technician was wearing dosimetry and it will be sent in for analysis. It is not expected that there was much additional exposure received. | ||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/ | | URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200716en.html#en54765 | ||
}} | }} | ||
{{ENS-Nav}} | {{ENS-Nav}} |
Revision as of 07:30, 16 July 2020
Where | |
---|---|
Ttl Associates, Inc Romulus, Michigan (NRC Region 3) | |
License number: | 21-2666601 |
Organization: | Ttl Associates, Inc |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+-3.37 h-0.14 days <br />-0.0201 weeks <br />-0.00462 months <br />) | |
Opened: | Jeffrey Elliott 14:38 Jul 7, 2020 |
NRC Officer: | Ossy Font |
Last Updated: | Jul 7, 2020 |
54765 - NRC Website | |