{{#Wiki_filter:Sequoyah Nuclear Plant | {{#Wiki_filter:Sequoyah Nuclear Plant PER Workorder Needing MRC or Supervisor Review Printout Page 11 PER256s 01/29/02 Recommend Levi Recommend Org Oper A Repo S Pot Pot Pot WorkOrder/Sta Entry Dt Department Identified By Supervisor Systems Units D Template: | ||
FE ME Oper Repo 91-18 the card replacement heard the adapter fail and took the necessary steps to locate the missing part. Due to its location, planning to remove additional cards was obtained. | |||
***** IMMEDIATE ACTION TAKEN ***** | ***** IMMEDIATE ACTION TAKEN ***** | ||
02-000822-000 01/28/2002 OPS 1 | 02-000822-000 01/28/2002 OPS 1 | ||
17:11 N | |||
***** DESCRIPTION OF CONDITION ***** | ***** DESCRIPTION OF CONDITION ***** | ||
The current Appendix - R program requires the Reactor Vessel Head Vent Valve fuses to be removed as a pre-emptive manual action for any declared Appendix-R fire. For fires in the 6.9 kv Shutdown Board Rooms, the accomplishment of this action may require the use of fire fighter 'turn-out' gear. Operations shift personnel are no longer qualified to utilize 'turn-out' gear nor does Operations maintain 'turn-out' gear for Operations shift personnel. | The current Appendix - R program requires the Reactor Vessel Head Vent Valve fuses to be removed as a pre-emptive manual action for any declared Appendix-R fire. | ||
For fires in the 6.9 kv Shutdown Board Rooms, the accomplishment of this action may require the use of fire fighter 'turn-out' gear. | |||
Operations shift personnel are no longer qualified to utilize 'turn-out' gear nor does Operations maintain 'turn-out' gear for Operations shift personnel. | |||
***** IMMEDIATE ACTION TAKEN ***** | ***** IMMEDIATE ACTION TAKEN ***** | ||
-r_}} | |||
Latest revision as of 03:30, 16 January 2025
| ML041100733 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 01/29/2002 |
| From: | Tennessee Valley Authority |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| FOIA/PA-2003-0358 | |
| Download: ML041100733 (1) | |
Text
Sequoyah Nuclear Plant PER Workorder Needing MRC or Supervisor Review Printout Page 11 PER256s 01/29/02 Recommend Levi Recommend Org Oper A Repo S Pot Pot Pot WorkOrder/Sta Entry Dt Department Identified By Supervisor Systems Units D Template:
FE ME Oper Repo 91-18 the card replacement heard the adapter fail and took the necessary steps to locate the missing part. Due to its location, planning to remove additional cards was obtained.
- IMMEDIATE ACTION TAKEN *****
02-000822-000 01/28/2002 OPS 1
17:11 N
- DESCRIPTION OF CONDITION *****
The current Appendix - R program requires the Reactor Vessel Head Vent Valve fuses to be removed as a pre-emptive manual action for any declared Appendix-R fire.
For fires in the 6.9 kv Shutdown Board Rooms, the accomplishment of this action may require the use of fire fighter 'turn-out' gear.
Operations shift personnel are no longer qualified to utilize 'turn-out' gear nor does Operations maintain 'turn-out' gear for Operations shift personnel.
- IMMEDIATE ACTION TAKEN *****