| title = | | title = LER 79-119/03L-0:on 791203,post-accident Radiation Monitors Could Have Had High Setpoint for Release Set Higher than Allowed by Tech Specs.Caused by Procedural Deficiency. Procedure Mods Prepared | ||
| author name = Scott R | | author name = Scott R | ||
| author affiliation = TOLEDO EDISON CO. | | author affiliation = TOLEDO EDISON CO. |
Latest revision as of 16:55, 23 January 2020
Date released: 09/28/2019 | Download: ML19257A180 |
---|---|
ML19257A182 | |
Person / Time | |
---|---|
Site: | Davis Besse |
Issue date: | 12/21/1979 |
From: | Scott R TOLEDO EDISON CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML19257A182 (2) | |
ML19257A179 | |
Person / Time | |
---|---|
Site: | Davis Besse |
Issue date: | 12/21/1979 |
From: | Murray T TOLEDO EDISON CO. |
To: | KEPPLER J G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |