| title = Forwards LER 80-026/03L-0
| title = LER 80-026/03L-0:on 800609,check Valves R-156 & R-157, Utilized as Containment Isolation Valves,Found Omitted from Type C Leak Test.Valve R-156 Installed Backwards.Caused by Omission in Procedure.Valve R-156 Reinstalled & Tested
| author name = Rischling J
| author name = Rischling J
| author affiliation = INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
| author affiliation = INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG

Latest revision as of 03:06, 7 March 2020

Forwards LER 80-026/03L-0
Date released: 05/31/2018 Download: ML17331A208


LER 80-026/03L-0:on 800609,check Valves R-156 & R-157, Utilized as Containment Isolation Valves,Found Omitted from Type C Leak Test.Valve R-156 Installed Backwards.Caused by Omission in Procedure.Valve R-156 Reinstalled & Tested
ML17331A209
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/08/1980
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A209 (4)
Forwards LER 80-026/03L-0
ML17331A207
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/08/1980
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A207 (2)