Line 22: | Line 22: | ||
The RSO contacted ThermoFisher Scientific and discovered that because of the age of the gauge, replacement parts could not be obtained. They were provided with a list of third-party service providers to assist with proper repair or removal and disposal of the gauge. The licensee will explore options and inform ODH [Ohio Department of Health] of the actions to be taken. | The RSO contacted ThermoFisher Scientific and discovered that because of the age of the gauge, replacement parts could not be obtained. They were provided with a list of third-party service providers to assist with proper repair or removal and disposal of the gauge. The licensee will explore options and inform ODH [Ohio Department of Health] of the actions to be taken. | ||
Ohio Item Number: OH190005 | Ohio Item Number: OH190005 | ||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/ | | URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/20190415en.html#en53978 | ||
}} | }} | ||
{{ENS-Nav}} | {{ENS-Nav}} |
Latest revision as of 07:30, 15 April 2019
Where | |
---|---|
Cardinal Operating Company Brilliant, Ohio (NRC Region 3) | |
License number: | 31201420000 |
Organization: | Ohio Bureau Of Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+35.32 h1.472 days <br />0.21 weeks <br />0.0484 months <br />) | |
Opened: | Stephen James 15:19 Apr 4, 2019 |
NRC Officer: | Mark Abramovitz |
Last Updated: | Apr 4, 2019 |
53978 - NRC Website | |