ENS 42745: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 07/09/2006 20:50 CDT | | event date = 07/09/2006 20:50 CDT | ||
| last update date = 07/31/2006 | | last update date = 07/31/2006 | ||
| title = Radiography Camera Source Unable | | title = Radiography Camera Source Unable to Retract | ||
| event text = Acuren Inspection, Inc, a Texas corporation doing inspection work in Michigan, provided the following information via email: | | event text = Acuren Inspection, Inc, a Texas corporation doing inspection work in Michigan, provided the following information via email: | ||
Description of Equipment Problem: The RT crew was using a 'pill stand' (a vertical metal pipe inserted into a coupling on a magnetic tripod with the source guide tube attached to a horizontal cross pipe) used to set up for an exposure. The 'pill stand' fell over during the exposure, thus crimping the source guide tube. | Description of Equipment Problem: The RT crew was using a 'pill stand' (a vertical metal pipe inserted into a coupling on a magnetic tripod with the source guide tube attached to a horizontal cross pipe) used to set up for an exposure. The 'pill stand' fell over during the exposure, thus crimping the source guide tube. |
Latest revision as of 22:18, 1 March 2018
Where | |
---|---|
Acuren Inspection, Inc Laporte, Texas (NRC Region 4) | |
License number: | 42-27593-01 |
Organization: | Acuren Inspection, Inc. |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+518.38 h21.599 days <br />3.086 weeks <br />0.71 months <br />) | |
Opened: | Kristi Kennedy 16:13 Jul 31, 2006 |
NRC Officer: | Mike Ripley |
Last Updated: | Jul 31, 2006 |
42745 - NRC Website | |