ENS 49983: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 11/12/2013 09:30 CDT
| event date = 11/12/2013 09:30 CDT
| last update date = 04/01/2014
| last update date = 04/01/2014
| title = Agreement State Report - Camera Failed To Retract Source Properly
| title = Agreement State Report - Camera Failed to Retract Source Properly
| event text = The following information was received from the State of Texas via email:
| event text = The following information was received from the State of Texas via email:
On March 26, 2014, the Agency [State of Texas - Department of State Health Services] received information that a source disconnect had occurred in November of the previous year. A subsequent report from the licensee received April 1, 2014 indicates that the disconnect occurred on November 12, 2013 at a temporary field site just west of Wink, Texas. The drive cable had become worn, allowing the source to be pushed out without being fully engaged with the pigtail. The source was pushed out of the guide tube but did not retract when the drive cable was cranked in. The camera was a QSA Model 880D S/N D6125, source QSA Global model A424-9 Ir-192 at 66.7 Ci, S/N 99589B. The source was recovered without further incident by attaching another drive cable. No exposure to the public resulted form this event. Additional information will be supplied as it is received in accordance with SA-300.
On March 26, 2014, the Agency [State of Texas - Department of State Health Services] received information that a source disconnect had occurred in November of the previous year. A subsequent report from the licensee received April 1, 2014 indicates that the disconnect occurred on November 12, 2013 at a temporary field site just west of Wink, Texas. The drive cable had become worn, allowing the source to be pushed out without being fully engaged with the pigtail. The source was pushed out of the guide tube but did not retract when the drive cable was cranked in. The camera was a QSA Model 880D S/N D6125, source QSA Global model A424-9 Ir-192 at 66.7 Ci, S/N 99589B. The source was recovered without further incident by attaching another drive cable. No exposure to the public resulted form this event. Additional information will be supplied as it is received in accordance with SA-300.

Latest revision as of 21:51, 1 March 2018

ENS 49983 +/-
Where
Big State X-Ray
Odessa, Texas (NRC Region 4)
License number: L02693
Organization: Texas Department Of Health
Reporting
Agreement State
Time - Person (Reporting Time:+3362.28 h140.095 days <br />20.014 weeks <br />4.606 months <br />)
Opened: Gentry Hearn
15:47 Apr 1, 2014
NRC Officer: Jeff Rotton
Last Updated: Apr 1, 2014
49983 - NRC Website