ENS 50615: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 11/14/2014 12:50 MST | | event date = 11/14/2014 12:50 MST | ||
| last update date = 11/17/2014 | | last update date = 11/17/2014 | ||
| title = Moisture Density Gauge Lost | | title = Moisture Density Gauge Lost in Transit | ||
| event text = Qal-Tek Associates, LLC reported that a Troxler Model 3450 Moisture/Density Gauge (Serial # 355) was lost in transit by the shipper. The device was being shipped from the owner, Simon Contracting in North Platte, NE, to Qal-Tek for repair. The device contains 8mCi Cs-137 and 40 mCi Am/Be. | | event text = Qal-Tek Associates, LLC reported that a Troxler Model 3450 Moisture/Density Gauge (Serial # 355) was lost in transit by the shipper. The device was being shipped from the owner, Simon Contracting in North Platte, NE, to Qal-Tek for repair. The device contains 8mCi Cs-137 and 40 mCi Am/Be. | ||
This is the same incident as NRC Event # 50619. | This is the same incident as NRC Event # 50619. |
Latest revision as of 21:49, 1 March 2018
Where | |
---|---|
Qal-Tek Associates, Llc Idaho Falls, Idaho (NRC Region 4) | |
License number: | 11-27610-01 |
Organization: | Qal-Tek Associates, Llc |
Reporting | |
10 CFR 20.2201(a)(1)(ii) | |
Time - Person (Reporting Time:+-3.9 h-0.163 days <br />-0.0232 weeks <br />-0.00534 months <br />) | |
Opened: | Glenn Sawtelle 15:56 Nov 14, 2014 |
NRC Officer: | Daniel Mills |
Last Updated: | Nov 17, 2014 |
50615 - NRC Website | |