| Line 1: |
Line 1: |
| {{Adams
| | #REDIRECT [[05000267/LER-1981-006-03, During Annual Testing & Calibr,Six of 12 Helium Circulator Seal Malfunction Pressure Differential Switch Units Tripped Outside Limits.Caused by Dirt Accumulation in Electrical Switches.Switches Replaced]] |
| | number = ML20003B115
| |
| | issue date = 02/03/1981
| |
| | title = /03L-0:on 810107,during Annual Testing & Calibr, Six Helium Circulator Seal Malfunction Pressure Differential Switch Units Discovered to Have Trip Points Set Outside Tech Spec Limits.Cause Unstated.Switches Readjusted
| |
| | author name = Gahm J
| |
| | author affiliation = PUBLIC SERVICE CO. OF COLORADO
| |
| | addressee name =
| |
| | addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
| |
| | docket = 05000267
| |
| | license number =
| |
| | contact person =
| |
| | document report number = LER-81-006-03L, LER-81-6-3L, NUDOCS 8102100369
| |
| | package number = ML20003B109
| |
| | document type = LICENSEE EVENT REPORT (SEE ALSO AO RO), TEXT-SAFETY REPORT
| |
| | page count = 1
| |
| }}
| |
| {{LER
| |
| | Title = /03L-0:on 810107,during Annual Testing & Calibr, Six Helium Circulator Seal Malfunction Pressure Differential Switch Units Discovered to Have Trip Points Set Outside Tech Spec Limits.Cause Unstated.Switches Readjusted
| |
| | Plant =
| |
| | Reporting criterion =
| |
| | Power level =
| |
| | Mode =
| |
| | Docket = 05000267
| |
| | LER year = 1981
| |
| | LER number = 6
| |
| | LER revision = 3
| |
| | Event date =
| |
| | Report date =
| |
| | ENS =
| |
| | abstract =
| |
| }}
| |
| | |
| =text=
| |
| {{#Wiki_filter:..
| |
| .N Rc F O AM 366 U. S. NUCLEAR REGULATORY COMMISSION (7 771 LICENSEE EVENT REPORT O
| |
| CCNTRCL BLOCK-l 1
| |
| l l
| |
| I l
| |
| h IPLE ASE PRINT OR TYPE ALL REQUIRED INFORMATION) l 0 l i l I C l O ! F l S f V I 1 l@I O ! 0 l - l 0 I n l 0 ! 0 l 0 l - l 0 l 0 l@l 4 l 1 l 1 l 2 I o l@ll l@
| |
| 7 8 9 LICENSEE COOE to 1S LICENSE % veer 26
| |
| ;e LiCgssE Tyag JC 37 C A r 34 CON'T loli!
| |
| C"J l t )@l 0 f s l 010 ! 0121 A ! 7 l@l o l i l o I T I a l t l@l 0121013 ! 8 t i l@
| |
| 6 60 61 OOCKET % MSEm sd 69 EVENT OATE 74
| |
| 't AE* CAT CATE 80 EVE *.T OESCRIPTICN AND PROB ABLE CCNSEQUENCES h 10121 lDuring annual testing and calibration. six of the tvelve helium circulator seal =al-l [ol3l 1 function pressure differential switch units were discovered to have a trip noint out-l l o 14 j l side the limits of LCO 4.4.1, Table 4.4-3.
| |
| These are recortable per Fort St. Vrain 1
| |
| 1o is j l Technical Specifications AC 7.5.2(b)1 and AC 7.5.2(b)2.
| |
| .= effect on public health l
| |
| l a M j l or safety. Redundant system available and oeerable. Similar reports are RO 77-47, I
| |
| j o i 7 ! [ Final and Preliminarv reports RO 78-27, 79-32, 79-56, 80-07. 80-16, 80-20. 80-26, I
| |
| io,4i l 80-34, 80-41, 80-51, and 80-72.
| |
| I 80 7
| |
| 8 7 system cab 5E CALSE Cov'
| |
| %ALvt CCCE CCCE SL9CCCE CGMPONENT CODE SL8COCE SUSC00E 10isi I C l a l@ Lt.J@ L:_J @ I r in IS IT I= l e l@ Ls_l@ l z i @
| |
| v e
| |
| 9 13 11 12 tJ 18 19 2J SE QUE NTI AL CCCURRENCE REPCRT REVISION gga og EVENTvEam mE*CRT No.
| |
| C00E TV'E NO.
| |
| @ qe g l a 11 l l-l l o 10 l e I l/l I nl al L'J I-I la_J 21 22 23 24
| |
| .6 21 28 29 JJ 31 32 N A T CN ON PLANT MET HOURS S8 I 80R 8
| |
| SLP8 E MAN 4FACTLRER lvl@ W @
| |
| W@
| |
| 19 l@
| |
| lo ln in lo l W@
| |
| l NI@
| |
| IN l@
| |
| l B l 0 l 8 10 l@
| |
| 3J 24 3b 26 J
| |
| 40 43 42 sa 44 47 CAUSE CESCA:9 TION AND CORRECTIVE ACTIONS l i 10 l lITT 3arton Model 289 oressure differential switches failed to actuate at trio noint i
| |
| 1ilijldue to dirt accumulation in electrical switches. Affected switches re-adiusted to I
| |
| i'I/Ilproper trip points. Surveillance Test satisfa,corily completed. Trip settings being g
| |
| ,,,3, [ checked on a monthly basis. Redesign of system being evaluated.
| |
| l I
| |
| Lu 4.1 1 30 7
| |
| 8 9
| |
| $T
| |
| % POWE R OTHER STATUS RY DISCOVERv QESCRIPT'ON li 15 l l G l@ l0 l o I o l@l l
| |
| lB l@lScheduledSurveillanceTest l
| |
| A/T,v,Tv CchT wouNT e, Acrivifv @ I LeCATicN o, RELEASE @
| |
| l i 161 l l @o :, EtEastL'J@l s/A u esE I
| |
| s/A I
| |
| 7
| |
| $ 9
| |
| 'O 11 44 45 t
| |
| 30
| |
| *ERSONNEL ExPOSLAES NUVSEe Tvet OESCRIPDON -
| |
| 1711 01 01 O l@l z l@l N/A I
| |
| i
| |
| ,E semel INJEs
| |
| :EsCR,,TicN@
| |
| % v.ER li i > l 1010101@l n/A I
| |
| 7 8 9 11 12 30 LOS$ OF CR DAMAGE To FACILITY Q TvP(
| |
| O($CRIPT!QN y
| |
| Ii I il Lz_J@l s/^
| |
| l 30 7
| |
| 4 9 10 NRC USE CNLY 33u,''@c'ESCR,,T,oN@
| |
| 68 69 30 ;
| |
| l l!lIIliIIIIIl}
| |
| l nri e
| |
| 12131 7
| |
| 3 3
| |
| ?3 (303) 735-2224 i
| |
| Nave oF A9EPARER '
| |
| WCNE:
| |
| sionion g
| |
| }}
| |
| | |
| {{LER-Nav}}
| |