NUREG-2192, Revision 1, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants, Draft Report for Comment, Corrected Tables 3.1-1 and 3.2-1: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[NUREG-2192, Federal Register Notice for NUREG-2192, Revision 1, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants, Draft Report for Comment, Corrected Tables 3.1-1 and 3.2-1]]
| number = ML23213A036
| issue date = 08/04/2023
| title = NUREG-2192, Revision 1, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants, Draft Report for Comment, Corrected Tables 3.1-1 and 3.2-1
| author name = Sayoc E
| author affiliation = NRC/NRR/DNRL/NLIB
| addressee name =
| addressee affiliation =
| docket =
| license number =
| contact person =
| document type = Graphics incl Charts and Tables
| page count = 1
| project =
| stage = Draft Approval
}}
 
=Text=
{{#Wiki_filter:1  Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System 2                Evaluated in Chapter IV of the GALL-SLR Report Aging Management                                Generic Aging New,                                                                          Program (AMP)/                            Lessons Learned Modified,                                                                        Time-Limited            Further          for Subsequent Deleted,                                                            Aging      Aging Analyses        Evaluation        License Renewal Edited Item    ID          Type            Component      Effect/Mechanism        (TLAA)          Recommended          (GALL-SLR) Item 001      Boiling water  Steel reactor        Cumulative fatigue TLAA, Standard      Yes (SRP-SLR        IV.A1.RP-201 reactor (BWR) /  vessel (RV) closure damage: cracking Review Plan for        Section 3.1.2.2.1)  IV.A2.RP-54 pressure water    flange assembly      due to fatigue,    Review of reactor (PWR)    components          cyclic loading    Subsequent exposed to air-                        License Renewal indoor uncontrolled                    (SRP-SLR)
Section 4.3 Metal Fatigue 3.1-30                002        PWR          Nickel-alloy tubes Cumulative fatigue TLAA, SRP-SLR          Yes (SRP-SLR        IV.D1.R-46 and sleeves          damage: cracking Section 4.3 Metal    Section 3.1.2.2.1)  IV.D2.R-46 exposed to reactor due to fatigue,      Fatigue coolant, secondary cyclic loading feedwater/steam 003      BWR/PWR        Stainless steel      Cumulative fatigue TLAA, SRP-SLR        Yes (SRP-SLR        IV.B1.R-53 (SS), nickel alloy  damage: cracking Section 4.3 Metal    Section 3.1.2.2.1)  IV.B2.RP-303 reactor vessel      due to fatigue,    Fatigue                                  IV.B3.RP-339 internal (RVI)      cyclic loading                                              IV.B4.R-53 components exposed to reactor coolant, neutron flux 004      BWR/PWR        Steel pressure      Cumulative fatigue TLAA, SRP-SLR        Yes (SRP-SLR        IV.A1.R-70 vessel support skirt damage: cracking Section 4.3 Metal    Section 3.1.2.2.1)  IV.A2.R-70 and attachment      due to fatigue,    Fatigue welds                cyclic loading 3
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                        Program (AMP)/                        Lessons Learned Modified,                                                                      Time-Limited        Further          for Subsequent Deleted,                                                          Aging      Aging Analyses    Evaluation        License Renewal Edited Item    ID        Type          Component          Effect/Mechanism        (TLAA)      Recommended          (GALL-SLR) Item 005        PWR      Steel, SS, steel      Cumulative fatigue TLAA, SRP-SLR    Yes (SRP-SLR        IV.C2.R-13 (with SS or nickel    damage: cracking Section 4.3 Metal Section 3.1.2.2.1)  IV.C2.R-18 alloy cladding)        due to fatigue,    Fatigue                              IV.D1.R-33 steam generator        cyclic loading                                          IV.D2.R-33 components, pressurizer relief tank components, piping components, bolting 3.1-31 006        BWR      SS, steel (with or    Cumulative fatigue TLAA, SRP-SLR    Yes (SRP-SLR        IV.C1.R-220 without nickel alloy  damage: cracking Section 4.3 Metal Section 3.1.2.2.1) or SS cladding),      due to fatigue,    Fatigue nickel alloy reactor  cyclic loading coolant pressure boundary components:
piping, piping components; other pressure retaining components exposed to reactor coolant 007        BWR      SS, steel (with or    Cumulative fatigue TLAA, SRP-SLR    Yes (SRP-SLR        IV.A1.R-04 without nickel alloy  damage: cracking Section 4.3 Metal Section 3.1.2.2.1) or SS cladding),      due to fatigue,    Fatigue nickel-alloy RV        cyclic loading components:
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                    Program (AMP)/                          Lessons Learned Modified,                                                                  Time-Limited            Further        for Subsequent Deleted,                                                        Aging      Aging Analyses          Evaluation      License Renewal Edited Item    ID        Type          Component          Effect/Mechanism    (TLAA)            Recommended      (GALL-SLR) Item nozzles, penetrations, safe ends, thermal sleeves, vessel shells, heads and welds exposed to reactor coolant 008        PWR      SS, steel (with or    Cumulative fatigue TLAA, SRP-SLR    Yes (SRP-SLR        IV.D1.R-221 without nickel alloy  damage: cracking Section 4.3 Metal Section 3.1.2.2.1)  IV.D2.R-222 3.1-32 or SS cladding),      due to fatigue,    Fatigue nickel-alloy steam    cyclic loading generator components exposed to reactor coolant 009        PWR      SS, steel (with or    Cumulative fatigue TLAA, SRP-SLR    Yes (SRP-SLR        IV.C2.R-223 without nickel alloy  damage: cracking Section 4.3 Metal Section 3.1.2.2.1) or SS cladding),      due to fatigue,    Fatigue nickel-alloy reactor  cyclic loading coolant pressure boundary piping, piping components, other pressure retaining components exposed to reactor coolant
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                      Program (AMP)/                        Lessons Learned Modified,                                                                    Time-Limited        Further          for Subsequent Deleted,                                                        Aging      Aging Analyses    Evaluation          License Renewal Edited Item    ID        Type          Component        Effect/Mechanism        (TLAA)      Recommended          (GALL-SLR) Item E        010        PWR      Steel (with or      Cumulative fatigue TLAA, SRP-SLR    Yes (SRP-SLR          IV.A2.R-219 without nickel alloy damage: cracking Section 4.3 Metal Section 3.1.2.2.1) or stainless steel  due to fatigue,    Fatigue cladding), SS, or    cyclic loading nickel-alloy RV components:
nozzles, penetrations, pressure housings, 3.1-33 safe ends; thermal sleeves, vessel shells, heads and welds exposed to reactor coolant E        011      BWR/PWR      Steel or SS pump      Cumulative fatigue TLAA, SRP-SLR    Yes (SRP-SLR        IV.C1.RP-44 and valve closure    damage: cracking Section 4.3 Metal Section 3.1.2.2.1)  IV.C2.RP-44 bolting exposed to    due to fatigue,    Fatigue high temperatures    cyclic loading and thermal cycles 012        PWR      Steel steam          Loss of material  AMP XI.M1,          Yes (SRP-SLR      IV.D1.RP-368 generator            due to general,    ASME Section XI    Sections components: upper    pitting, crevice  Inservice          3.1.2.2.2.1 and and lower shells,    corrosion          Inspection,        3.1.2.2.2.2) transition cone,                        Subsections IWB, new transition cone                      IWC, and IWD, closure weld                            and AMP XI.M2, exposed to                              Water Chemistry
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                  Generic Aging New,                                                                      Program (AMP)/                              Lessons Learned Modified,                                                                    Time-Limited                Further        for Subsequent Deleted,                                                        Aging      Aging Analyses              Evaluation      License Renewal Edited Item    ID        Type        Component            Effect/Mechanism    (TLAA)                Recommended      (GALL-SLR) Item secondary feedwater or steam 013      BWR/PWR      Steel (with or          Loss of fracture      TLAA, SRP-SLR    Yes (SRP-SLR        IV.A1.R-62 without stainless      toughness due to      Section 4.2      Section 3.1.2.2.3.1) IV.A2.R-84 steel or nickel-alloy  neutron irradiation  Reactor Pressure cladding) reactor      embrittlement        Vessel Neutron vessel beltline                              Embrittlement shell, nozzle, and weld components 3.1-34 exposed to reactor coolant and neutron flux 014      BWR/PWR      Steel (with or          Loss of fracture      AMP XI.M31,        Yes (SRP-SLR        IV.A1.RP-227 without cladding)      toughness due to      Reactor Vessel    Section 3.1.2.2.3.2) IV.A2.RP-229 reactor vessel          neutron irradiation  Material beltline shell,        embrittlement        Surveillance, and nozzle, and weld                              AMP X.M2, components,                                  Neutron Fluence exposed to reactor                            Monitoring coolant and neutron flux E        015        PWR      Stainless steel        Reduction in          TLAA, SRP-SLR      Yes (SRP-SLR        IV.B4.RP-376 Babcock & Wilcox        fracture toughness    Section 4.7 Other Section 3.1.2.2.3.3)
(B&W) (including        due to neutron        Plant-Specific cast austenitic        irradiation          TLAAs stainless steel
[CASS], martensitic
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                  Generic Aging New,                                                                  Program (AMP)/                            Lessons Learned Modified,                                                                Time-Limited              Further        for Subsequent Deleted,                                                      Aging      Aging Analyses            Evaluation      License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)              Recommended      (GALL-SLR) Item SS, and precipitation-hardened [PH] SS) and nickel-alloy RVI components exposed to reactor coolant and neutron flux 016        BWR      SS or nickel-alloy  Cracking due to      AMP XI.M32,        Yes (SRP-SLR        IV.A1.R-61a 3.1-35 reactor vessel top  SCC, intergranular  One-Time          Section 3.1.2.2.4.1) IV.A1.R-61b head enclosure      stress corrosion    Inspection, or flange leakage      cracking (IGSCC)    AMP XI.M36, detection line                            External Surfaces exposed to air-                          Monitoring of indoor                                    Mechanical uncontrolled,                            Components reactor coolant leakage 017        BWR      SS isolation        Cracking due to      AMP XI.M1,        Yes (SRP-SLR        IV.C1.R-15 condenser            SCC, irradiation-    ASME Section XI Section 3.1.2.2.4.2) components          assisted stress      Inservice exposed to reactor  corrosion cracking  Inspection, coolant              (IGSCC)              Subsections IWB, IWC, and IWD, and AMP XI.M2, Water Chemistry
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                    Program (AMP)/                          Lessons Learned Modified,                                                                  Time-Limited          Further          for Subsequent Deleted,                                                      Aging      Aging Analyses      Evaluation        License Renewal Edited Item    ID        Type          Component      Effect/Mechanism        (TLAA)        Recommended          (GALL-SLR) Item 018        PWR      RV shell fabricated Crack growth due TLAA, SRP-SLR      Yes (SRP-SLR        IV.A2.R-85 of SA508-Cl 2      to cyclic loading Section 4.7 Other Section 3.1.2.2.5) forgings clad with                    Plant-Specific SS using a high-                      TLAAs heat-input welding process exposed to reactor coolant M        019        PWR      SS RV bottom-        Cracking due to    AMP XI.M1,        No                  IV.A2.RP-154 mounted              stress corrosion  ASME Section XI 3.1-36 instrument guide    cracking (SCC)    Inservice tubes (external to                      Inspection, RV) exposed to                          Subsections IWB, reactor coolant                        IWC, and IWD, and AMP XI.M2, Water Chemistry M        020        PWR      cast austenitic    Cracking due to      AMP XI.M1,        No                  IV.C2.R-05 stainless steel    SCC                  ASME Section XI (CASS) Class 1                          Inservice piping, piping                          Inspection, components                              Subsections IWB, exposed to reactor                      IWC, and IWD, coolant                                and AMP XI.M2, Water Chemistry 021        BWR      Steel and SS        Cracking due to    AMP XI.M1,      Yes (SRP-SLR        IV.C1.R-225 isolation condenser cyclic loading      ASME Section XI Section 3.1.2.2.7) components                              Inservice Inspection,
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                        Generic Aging New,                                                                  Program (AMP)/                                  Lessons Learned Modified,                                                                Time-Limited                    Further          for Subsequent Deleted,                                                    Aging      Aging Analyses                  Evaluation      License Renewal Edited Item    ID        Type        Component      Effect/Mechanism      (TLAA)                    Recommended        (GALL-SLR) Item exposed to reactor                  Subsections IWB, coolant                            IWC, and IWD 022        PWR      Steel steam      Loss of material          Plant-specific aging Yes (SRP-SLR        IV.D1.R-39 generator (SG)    due to erosion            management          Section 3.1.2.2.8) feedwater                                  program impingement plate and support exposed to secondary 3.1-37 feedwater M        025        PWR      Steel (with nickel- Cracking due to        AMP XI.M2, Water    Yes (SRP-SLR        IV.D1.RP-367 alloy cladding) or primary water SCC        Chemistry, and      Sections            IV.D1.RP-385 nickel-alloy SG                            AMP XI.M19,          3.1.2.2.11.1 and    IV.D2.RP-185 (primary side                              Steam Generator    3.1.2.2.11.2) components:                                In addition, use of divider plate and                          the One-Time tube-to-tube sheet                          Inspection AMP is welds exposed to                            to be evaluated reactor coolant M        028        PWR      Westinghouse-          Loss of material    AMP XI.M16A,      Yes (SRP-SLR            IV.B2.RP-355 (if specific Existing    due to wear;        PWR Vessel      Section 3.1.2.2.9)      AMP XI.M16A is Programs              cracking due to      Internals, and                          credited for aging components: SS,        SCC, irradiation-    AMP XI.M2, Water                        management) nickel-alloy, and X-  assisted stress      Chemistry (for 750 control rod        corrosion cracking  SCC mechanisms                            IV.E.R-444 (if guide tube support    (IASCC), fatigue    only)                                    components are pins (split pins)                                                                    defined as ASME
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                  Program (AMP)/                    Lessons Learned Modified,                                                                Time-Limited        Further      for Subsequent Deleted,                                                      Aging      Aging Analyses      Evaluation    License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)        Recommended    (GALL-SLR) Item exposed to reactor                                                      Section XI category coolant and                                                            components and neutron flux                                                            the XI.M1 inservice inspection AMP is credited for aging management)
IV.B2.RP-265 (if components can be 3.1-38 placed in the No Additional Measures category)
M        029        BWR      Nickel-alloy core  Cracking due to    AMP XI.M9, BWR No              IV.B1.R-94 shroud and core    SCC, IGSCC,        Vessel Internals, plate access hole IASCC                and AMP XI.M2, cover (welded                          Water Chemistry covers) exposed to reactor coolant 030        BWR      Stainless steel,    Cracking due to  AMP XI.M1,        No            IV.A1.RP-371 nickel alloy        SCC, IGSCC,      ASME Section XI penetration: drain  cyclic loading    Inservice line exposed to                        Inspection, reactor coolant                        Subsections IWB, IWC, and IWD, and AMP XI.M2, Water Chemistry
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                    Program (AMP)/                          Lessons Learned Modified,                                                                  Time-Limited              Further      for Subsequent Deleted,                                                      Aging      Aging Analyses            Evaluation  License Renewal Edited Item    ID        Type        Component          Effect/Mechanism      (TLAA)              Recommended    (GALL-SLR) Item (SCC, IGSCC mechanisms only) 031        BWR      Steel and SS          Loss of material        AMP XI.M1,        No            IV.C1.RP-39 isolation condenser  due to general          ASME Section XI components            (steel only), pitting,  Inservice exposed to reactor    crevice corrosion,      Inspection, coolant              wear                    Subsections IWB, IWC, and IWD, and AMP XI.M2, 3.1-39 Water Chemistry D        032 033        PWR      SS, steel with SS    Cracking due to          AMP XI.M1,        No            IV.C2.R-09 cladding Class 1      SCC                      ASME Section XI                IV.C2.R-217 reactor coolant                                Inservice                        IV.C2.RP-344 pressure boundary                              Inspection,                      IV.D1.RP-232 components                                    Subsections IWB, exposed to reactor                            IWC, and IWD, coolant                                        and AMP XI.M2, Water Chemistry E        034        PWR      SS, steel with SS Cracking due to              AMP XI.M1,        No            IV.C2.RP-231 cladding            SCC                      ASME Section XI pressurizer relief                            Inservice tank (tank shell and                          Inspection, heads, flanges,                                Subsections IWB, nozzles) exposed                              IWC, and IWD, to treated borated                            and AMP XI.M2, Water Chemistry
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                    Program (AMP)/                    Lessons Learned Modified,                                                                  Time-Limited          Further      for Subsequent Deleted,                                                        Aging      Aging Analyses        Evaluation  License Renewal Edited Item    ID        Type        Component          Effect/Mechanism    (TLAA)          Recommended    (GALL-SLR) Item water >60 °C
(>140 °F) 035        PWR      SS, steel with SS      Cracking due to    AMP XI.M1,      No              IV.C2.R-56 cladding reactor      cyclic loading    ASME Section XI coolant system                            Inservice cold leg, hot leg,                        Inspection, surge line, and                          Subsections IWB, spray line piping                        IWC, and IWD and fittings 3.1-40 exposed to reactor coolant 036        PWR      Steel, SS              Cracking due to    AMP XI.M1,      No              IV.C2.R-19 pressurizer integral  cyclic loading    ASME Section XI support exposed to                        Inservice any environment                          Inspection, Subsections IWB, IWC, and IWD 037        PWR      Steel reactor          Loss of material  AMP XI.M1,      No              IV.A2.R-87 vessel flange          due to wear        ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD 038      BWR/PWR      CASS Class 1          Loss of fracture  AMP XI.M1,      No              IV.C1.R-08 valve bodies and      toughness due to  ASME Section XI                IV.C2.R-08 bonnets exposed        thermal aging      Inservice embrittlement      Inspection,
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                Generic Aging New,                                                                  Program (AMP)/                          Lessons Learned Modified,                                                                Time-Limited                Further      for Subsequent Deleted,                                                    Aging      Aging Analyses              Evaluation  License Renewal Edited Item    ID        Type          Component      Effect/Mechanism      (TLAA)                Recommended    (GALL-SLR) Item to reactor coolant                  Subsections IWB,
                                            >250 °C (>482 °F)                  IWC, and IWD E        039      BWR/PWR      SS, steel (with or    Cracking due to      AMP XI.M1,        No            IV.C1.RP-230 without nickel-alloy  SCC (for SS or      ASME Section XI                  IV.C2.RP-235 or SS cladding),      nickel-alloy        Inservice nickel-alloy Class 1  surfaces exposed    Inspection, piping, fittings and  to reactor coolant  Subsections IWB, branch connections    only), IGSCC (for    IWC, and IWD,
                                            <nominal pipe size    stainless steel or  AMP XI.M2, Water 3.1-41 (NPS) 4 exposed        nickel-alloy        Chemistry, and to reactor coolant    surfaces exposed    XI.M35, ASME to reactor coolant  Code Class 1 only), or thermal,  Small-Bore Piping mechanical, or vibratory loading 040        PWR      Steel with SS or  Cracking due to          AMP XI.M1,      No              IV.C2.R-58 nickel-alloy      cyclic loading          ASME Section XI cladding, or SS                            Inservice pressurizer                                Inspection, components                                  Subsections IWB, exposed to reactor                          IWC, and IWD coolant 040a        PWR      Nickel-alloy core  Cracking due to          AMP XI.M1,      No              IV.A2.RP-57 support pads, core primary water SCC        ASME Section XI guide lugs exposed                          Inservice to reactor coolant                          Inspection, Subsections IWB,
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                    Program (AMP)/                    Lessons Learned Modified,                                                                  Time-Limited          Further      for Subsequent Deleted,                                                      Aging      Aging Analyses        Evaluation  License Renewal Edited Item    ID        Type        Component          Effect/Mechanism      (TLAA)          Recommended    (GALL-SLR) Item IWC, and IWD, and AMP XI.M2, Water Chemistry M        041        BWR      Nickel-alloy core  Cracking due to        AMP XI.M9, BWR No              IV.B1.R-95 shroud and core    SCC, IGSCC,            Vessel Internals, plate access hole IASCC                  and AMP XI.M2, cover (mechanical                        Water Chemistry covers) exposed to reactor coolant 3.1-42                042        PWR      Steel with SS or      Cracking due to    AMP XI.M1,        No            IV.C2.R-25 nickel-alloy          SCC, primary        ASME Section XI                IV.D2.RP-47 cladding, SS          water SCC          Inservice primary side                              Inspection, components, SG                            Subsections IWB, upper and lower                          IWC, and IWD, heads, and                                and AMP XI.M2, tubesheet welds                          Water Chemistry pressurizer components exposed to reactor coolant 043        BWR      SS and nickel-alloy  Loss of material    AMP XI.M1,      No              IV.B1.RP-26 RVI exposed to        due to pitting,    ASME Section XI reactor coolant      crevice corrosion  Inservice Inspection, Subsections IWB, IWC, and IWD,
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                  Program (AMP)/                      Lessons Learned Modified,                                                                Time-Limited            Further      for Subsequent Deleted,                                                    Aging      Aging Analyses          Evaluation  License Renewal Edited Item    ID        Type        Component      Effect/Mechanism      (TLAA)            Recommended    (GALL-SLR) Item and AMP XI.M2, Water Chemistry 044        PWR      Steel SG          Loss of material      AMP XI.M1,      No              IV.D1.R-31 secondary manway due to erosion        ASME Section XI                  IV.D2.R-31 and handhole                            Inservice cover seating                          Inspection, surfaces exposed                        Subsections IWB, to treated water,                      IWC, and IWD steam 3.1-43        E        045        PWR      Nickel-alloy, steel Cracking due to    AMP XI.M1,        No            IV.A2.R-90 with nickel-alloy  primary water SCC  ASME Section XI                  IV.A2.RP-186 cladding reactor                        Inservice                        IV.A2.RP-59 coolant pressure                        Inspection,                      IV.C2.RP-156 boundary                                Subsections IWB,                  IV.C2.RP-159 components                              IWC and IWD, and                IV.C2.RP-37 exposed to reactor                      AMP XI.M2,                        IV.D1.RP-36 coolant                                Water Chemistry,                IV.D2.RP-36 and, for nickel-alloy, AMP XI.M11B, Cracking of Nickel-Alloy Components and Loss of Material due to Boric Acid-Induced Corrosion in reactor coolant pressure boundary
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                        Generic Aging New,                                                                  Program (AMP)/                    Lessons Learned Modified,                                                                Time-Limited        Further      for Subsequent Deleted,                                                    Aging      Aging Analyses      Evaluation  License Renewal Edited Item    ID        Type        Component        Effect/Mechanism      (TLAA)        Recommended    (GALL-SLR) Item (RCPB)
Components (PWRs Only)
E        046        PWR      SS, nickel-alloy  Cracking due to    AMP XI.M1,        No            IV.A2.RP-234 control rod drive  SCC, primary      ASME Section XI head penetration water SCC            Inservice pressure housings,                    Inspection, RV nozzles, nozzle                    Subsections IWB, safe ends and                        IWC and IWD, and 3.1-44 welds exposed to                      AMP XI.M2, reactor coolant                      Water Chemistry, and, for nickel-alloy, AMP XI.M11B, Cracking of Nickel-Alloy Components and Loss of Material due to Boric Acid-Induced Corrosion in RCPB Components (PWRs Only) 047        PWR      SS, nickel-alloy    Cracking due to  AMP XI.M1,      No              IV.A2.RP-55 control rod drive  SCC, primary      ASME Section XI head penetration    water SCC        Inservice pressure housing                      Inspection, Subsections IWB,
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                  Program (AMP)/                        Lessons Learned Modified,                                                                Time-Limited            Further      for Subsequent Deleted,                                                    Aging      Aging Analyses          Evaluation  License Renewal Edited Item    ID        Type        Component      Effect/Mechanism      (TLAA)            Recommended    (GALL-SLR) Item exposed to reactor                  IWC and IWD, and coolant                            AMP XI.M2, Water Chemistry E        048        PWR      Steel external      Loss of material    AMP XI.M10,        No            IV.A2.RP-379 surfaces: RV top    due to boric acid  Boric Acid                      IV.C2.RP-380 head, RV bottom      corrosion          Corrosion, and head, reactor                            AMP XI.M11B, coolant pressure                        Cracking of boundary piping or                      Nickel-Alloy 3.1-45 components                              Components and adjacent to                              Loss of Material dissimilar metal                        due to Boric Acid-(Alloy 82/182)                          Induced Corrosion welds exposed to                        in RCPB air with borated                        Components water leakage                            (PWRs Only) 049        PWR      Steel reactor,      Loss of material    AMP XI.M10,        No            IV.A2.R-17 vessel, piping,      due to boric acid  Boric Acid                      IV.C2.R-17 piping components    corrosion          Corrosion                        IV.C2.RP-167 in the reactor                                                            IV.D1.R-17 coolant pressure                                                          IV.D2.R-17 boundary of PWRs, and applicable exterior attachments, or steel steam generators in
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                Generic Aging New,                                                                    Program (AMP)/                          Lessons Learned Modified,                                                                  Time-Limited            Further          for Subsequent Deleted,                                                      Aging      Aging Analyses          Evaluation      License Renewal Edited Item    ID        Type          Component        Effect/Mechanism    (TLAA)            Recommended        (GALL-SLR) Item PWRs: external surfaces or closure bolting exposed to air with borated water leakage 050      BWR/PWR      CASS Class 1          Loss of fracture  AMP XI.M12,        No                  IV.A2.R-77 piping, piping        toughness due to  Thermal Aging                        IV.C1.R-52 components            thermal aging      Embrittlement of                      IV.C2.R-52 (including pump      embrittlement      Cast Austenitic 3.1-46 casings and control                      Stainless Steel rod drive pressure                      (CASS) housings) exposed to reactor coolant
                                            >250 &deg;F (>482 &deg;C)
M        051a        PWR      SS, nickel-alloy  Cracking due to      AMP XI.M16A,      Yes (SRP-SLR        IV.B4.RP-241 Babcock and        SCC, IASCC,          PWR Vessel      Section 3.1.2.2.9)  IV.B4.RP-241a Wilcox (B&W)      fatigue              Internals, and                        IV.B4.RP-242a reactor internal                        AMP XI.M2, Water                      IV.B4.RP-247 Primary                                Chemistry (for                        IV.B4.RP-247a components                              SCC mechanisms                        IV.B4.RP-248 exposed to reactor                      only)                                  IV.B4.RP-248a coolant, neutron                                                                IV.B4.RP-252c flux                                                                            IV.B4.RP-256 IV.B4.RP-256a IV.B4.RP-261
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                    Program (AMP)/                        Lessons Learned Modified,                                                                  Time-Limited        Further          for Subsequent Deleted,                                                    Aging        Aging Analyses    Evaluation          License Renewal Edited Item    ID        Type          Component    Effect/Mechanism        (TLAA)      Recommended          (GALL-SLR) Item M        051b        PWR      SS, nickel-alloy  Cracking due to  AMP XI.M16A,      Yes (SRP-SLR          IV.B4.RP-244 B&W reactor        SCC, IASCC,      PWR Vessel      Section 3.1.2.2.9)    IV.B4.RP-245 internal          fatigue, overload Internals, and                        IV.B4.RP-245a Expansion                          AMP XI.M2, Water                      IV.B4.RP-246 components                          Chemistry (for                        IV.B4.RP-246a exposed to reactor                  SCC mechanisms                          IV.B4.RP-246c coolant, neutron                    only)                                  IV.B4.RP-246d flux                                                                        IV.B4.RP-260a IV.B4.RP-262 3.1-47 IV.B4.RP-352 M        052a        PWR      SS, nickel-alloy  Cracking due to    AMP XI.M16A,      Yes (SRP-SLR        IV.B3.RP-312 Combustion        SCC, IASCC,        PWR Vessel      Section 3.1.2.2.9)  IV.B3.RP-314 Engineering (CE) fatigue              Internals, and                        IV.B3.RP-322 reactor internal                      AMP XI.M2, Water                      IV.B3.RP-324 Primary                            Chemistry (for                        IV.B3.RP-327 components                            SCC mechanisms                        IV.B3.RP-328 exposed to reactor                    only)                                  IV.B3.RP-338 coolant, neutron                                                            IV.B3.RP-342 flux                                                                        IV.B3.RP-343 IV.B3.RP-358 IV.B3.RP-362a M        052b        PWR      SS, nickel-alloy CE Cracking due to  AMP XI.M16A,      Yes (SRP-SLR        IV.B3.RP-313 reactor internal    SCC, IASCC,      PWR Vessel      Section 3.1.2.2.9)  IV.B3.RP-316 Expansion        fatigue          Internals, and                        IV.B3.RP-323 components                            AMP XI.M2,                            IV.B3.RP-325 exposed to reactor                    Water Chemistry                      IV.B3.RP-329 IV.B3.RP-330
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                  Program (AMP)/                          Lessons Learned Modified,                                                                Time-Limited          Further          for Subsequent Deleted,                                                    Aging        Aging Analyses        Evaluation        License Renewal Edited Item    ID        Type          Component    Effect/Mechanism      (TLAA)          Recommended        (GALL-SLR) Item coolant, neutron                    (for SCC                                IV.B3.RP-333 flux                                mechanisms only)                        IV.B3.RP-335 IV.B3.RP-362c IV.B3.RP-363 M        052c        PWR      SS, nickel-alloy CE Cracking due to  AMP XI.M16A,      Yes (SRP-SLR        IV.B3.RP-320 reactor internal    SCC, IASCC,      PWR Vessel      Section 3.1.2.2.9)  IV.B3.RP-320a Existing          fatigue          Internals, and                        IV.B3.RP-334 Programs                            AMP XI.M2, components                            Water Chemistry 3.1-48 exposed to reactor                    (for SCC coolant, neutron                      mechanisms only) flux M        053a        PWR      SS, nickel-alloy  Cracking due to    AMP XI.M16A,      Yes (SRP-SLR        IV.B2.RP-270a Westinghouse      SCC, IASCC,        PWR Vessel      Section 3.1.2.2.9)  IV.B2.RP-271 reactor internal  fatigue            Internals, and                        IV.B2.RP-275 Primary                            AMP XI.M2,                            IV.B2.RP-276 components                            Water Chemistry                      IV.B2.RP-296a exposed to reactor                    (for SCC                              IV.B2.RP-298 coolant, neutron                      mechanisms only)                      IV.B2.RP-302 flux                                                                        IV.B2.RP-387 M        053b        PWR      SS Westinghouse Cracking due to      AMP XI.M16A,      Yes (SRP-SLR        IV.B2.RP-273 reactor internal  SCC, IASCC,        PWR Vessel      Section 3.1.2.2.9)  IV.B2.RP-280 Expansion        fatigue            Internals, and                        IV.B2.RP-286 components                            AMP XI.M2,                            IV.B2.RP-291 exposed to reactor                    Water Chemistry                      IV.B2.RP-291a coolant and                          (for SCC                              IV.B2.RP-291b neutron flux                          mechanisms only)
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                  Generic Aging New,                                                                  Program (AMP)/                            Lessons Learned Modified,                                                                Time-Limited            Further            for Subsequent Deleted,                                                    Aging      Aging Analyses          Evaluation        License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)            Recommended          (GALL-SLR) Item IV.B2.RP-293 IV.B2.RP-294 IV.B2.RP-298a IV.B2.RP-387a M        053c        PWR      SS, nickel-alloy, or Cracking due to  AMP XI.M16A,      Yes (SRP-SLR          IV.B2.RP-289 stellite            SCC, IASCC,      PWR Vessel      Section 3.1.2.2.9)    IV.B2.RP-301 Westinghouse        fatigue          Internals, and                        IV.B2.RP-345a reactor internal                      AMP XI.M2,                              IV.B2.RP-346 Existing                              Water Chemistry                      IV.B2.RP-399 3.1-49 Programs                              (for SCC components                            mechanisms only) exposed to reactor coolant, neutron flux M        054        PWR      SS Westinghouse- Loss of material      AMP XI.M37,        No                  IV.B2.RP-284 design bottom-    due to wear        Flux Thimble Tube mounted                                Inspection instrument system flux thimble tubes (with or without chrome plating) exposed to reactor coolant and neutron flux 055a        PWR      SS, nickel alloy    No additional aging AMP XI.M16A,      Yes (SRP-SLR        IV.B4.RP-236 B&W reactor        management for      PWR Vessel      Section 3.1.2.2.9) internal No        reactor internal No Internals
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                Generic Aging New,                                                                  Program (AMP)/                            Lessons Learned Modified,                                                                Time-Limited            Further          for Subsequent Deleted,                                                    Aging      Aging Analyses          Evaluation        License Renewal Edited Item    ID        Type          Component    Effect/Mechanism      (TLAA)            Recommended        (GALL-SLR) Item Additional        Additional Measures          Measures components        components unless exposed to reactor required by ASME coolant, neutron  Section XI, flux              Examination Category B-N-3 or relevant operating experience exists 3.1-50 055b        PWR      SS, nickel-alloy CE  No additional aging    AMP XI.M16A,  Yes (SRP-SLR        IV.B3.RP-306 reactor internal No management for        PWR Vessel    Section 3.1.2.2.9)
Additional          reactor internal No  Internals Measures            Additional components          Measures exposed to reactor  components unless coolant, neutron    required by ASME flux                Section XI, Examination Category B-N-3 or relevant operating experience exists 055c        PWR      SS, nickel-alloy    No additional aging    AMP XI.M16A,  Yes (SRP-SLR        IV.B2.RP-265 Westinghouse        management for        PWR Vessel    Section 3.1.2.2.9) reactor internal No reactor internal No  Internals Additional          Additional Measures            Measures components          components unless
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                  Program (AMP)/                          Lessons Learned Modified,                                                                Time-Limited          Further          for Subsequent Deleted,                                                    Aging      Aging Analyses        Evaluation        License Renewal Edited Item    ID        Type          Component    Effect/Mechanism      (TLAA)          Recommended        (GALL-SLR) Item exposed to reactor required by ASME coolant, neutron  Section XI, flux              Examination Category B-N-3 or relevant operating experience exists M        056a        PWR      SS, including        Loss of fracture    AMP XI.M16A,  Yes (SRP-SLR        IV.B3.RP-315 CASS,                toughness due to PWR Vessel        Section 3.1.2.2.9)  IV.B3.RP-318 precipitation-      neutron irradiation Internals                          IV.B3.RP-326 3.1-51 hardening (PH) SS    embrittlement and                                        IV.B3.RP-338a or martensitic SS    for CASS,                                                IV.B3.RP-359 or nickel-alloy CE  martensitic SS, and                                      IV.B3.RP-360 reactor internal    PH SS due to                                            IV.B3.RP-362 Primary            thermal aging                                            IV.B3.RP-365 components          embrittlement,                                          IV.B3.RP-366 exposed to reactor  changes in coolant and          dimensions due to neutron flux        void swelling, distortion, loss of preload due to thermal and irradiation-enhanced stress relaxation or creep, loss of material due to wear
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                      Program (AMP)/                        Lessons Learned Modified,                                                                    Time-Limited        Further          for Subsequent Deleted,                                                      Aging        Aging Analyses    Evaluation          License Renewal Edited Item    ID        Type        Component      Effect/Mechanism          (TLAA)      Recommended          (GALL-SLR) Item M        056b        PWR      SS, including      Loss of fracture    AMP XI.M16A,    Yes (SRP-SLR          IV.B3.RP-317 CASS, PH SS or    toughness due to PWR Vessel        Section 3.1.2.2.9)    IV.B3.RP-331 martensitic SS CE neutron irradiation Internals                              IV.B3.RP-333a Expansion        embrittlement and                                          IV.B3.RP-359a reactor internal  for CASS,                                                  IV.B3.RP-361 components        martensitic SS, and                                        IV.B3.RP-362b exposed to reactor PH SS due to                                              IV.B3.RP-364 coolant and        thermal aging                                              IV.B3.R-455 neutron flux      embrittlement, 3.1-52 changes in dimensions due to void swelling, distortion, loss of preload due to thermal and irradiation-enhanced stress relaxation or creep, loss of material due to wear M        056c        PWR      SS, including      Loss of fracture    AMP XI.M16A,    Yes (SRP-SLR        IV.B3.RP-319 CASS, PH SS or      toughness due to PWR Vessel        Section 3.1.2.2.9)  IV.B3.RP-332 martensitic SS or  neutron irradiation Internals                            IV.B3.RP-336 nickel-alloy CE    embrittlement and                                        IV.B3.RP-357 reactor internal    for CASS, Existing          martensitic SS, and Programs          PH SS due to components          thermal aging
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                    Program (AMP)/                          Lessons Learned Modified,                                                                  Time-Limited          Further          for Subsequent Deleted,                                                      Aging        Aging Analyses        Evaluation        License Renewal Edited Item    ID        Type        Component      Effect/Mechanism        (TLAA)          Recommended        (GALL-SLR) Item exposed to reactor embrittlement, coolant and        changes in neutron flux      dimensions due to void swelling, distortion, loss of preload due to thermal and irradiation-enhanced stress 3.1-53 relaxation or creep, loss of material due to wear M        058a        PWR      SS, including        Loss of fracture      AMP XI.M16A,  Yes (SRP-SLR        IV.B4.RP-240 CASS, PH SS or      toughness due to PWR Vessel          Section 3.1.2.2.9)  IV.B4.RP-240a martensitic SS,      neutron irradiation Internals                            IV.B4.RP-242 nickel-alloy B&W    embrittlement and                                          IV.B4.RP-247b reactor internal    for CASS,                                                  IV.B4.RP-247c Primary            martensitic SS, and                                        IV.B4.RP-248b components          PH SS due to                                              IV.B4.RP-249 exposed to reactor  thermal aging                                              IV.B4.RP-251 coolant and          embrittlement, or                                          IV.B4.RP-251a neutron flux        changes in                                                IV.B4.RP-252 dimensions due to                                          IV.B4.RP-252b void swelling or                                          IV.B4.RP-256b distortion, or loss of                                    IV.B4.RP-258 preload due to                                            IV.B4.RP-259 wear; or loss of
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                Generic Aging New,                                                                  Program (AMP)/                            Lessons Learned Modified,                                                                Time-Limited            Further          for Subsequent Deleted,                                                      Aging      Aging Analyses          Evaluation        License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)            Recommended        (GALL-SLR) Item material due to wear M        058b        PWR      SS, including        Loss of fracture      AMP XI.M16A,  Yes (SRP-SLR        IV.B4.RP-243 CASS, PH SS or      toughness due to PWR Vessel          Section 3.1.2.2.9)  IV.B4.RP-243a martensitic SS,      neutron irradiation Internals                            IV.B4.RP-245b nickel-alloy B&W    embrittlement and                                          IV.B4.RP-245c reactor internal    for CASS,                                                  IV.B4.RP-246b Expansion          martensitic SS, and                                        IV.B4.RP-246e components          PH SS due to                                              IV.B4.RP-250 3.1-54 exposed to reactor  thermal aging                                              IV.B4.RP-252a coolant and          embrittlement, or                                          IV.B4.RP-260 neutron flux        changes in                                                iv.B4.RP-386 dimensions due to void swelling, or distortion, or loss of preload due to thermal and irradiation-enhanced stress relaxation or creep, or loss of material due to wear 059a        PWR      SS, including        Loss of fracture    AMP XI.M16A,      Yes (SRP-SLR        IV.B2.RP-270 CASS, PH SS or      toughness due to PWR Vessel          Section 3.1.2.2.9)  IV.B2.RP-272 martensitic SS or    neutron irradiation Internals                            IV.B2.RP-296 nickel-alloy        embrittlement and                                          IV.B2.RP-297 Westinghouse        for CASS,                                                  IV.B2.RP-302a
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                    Program (AMP)/                        Lessons Learned Modified,                                                                  Time-Limited        Further            for Subsequent Deleted,                                                      Aging        Aging Analyses      Evaluation        License Renewal Edited Item    ID        Type          Component      Effect/Mechanism        (TLAA)        Recommended          (GALL-SLR) Item reactor internal  martensitic SS, and                                        IV.B2.RP-354 Primary          PH SS due to                                              IV.B2.RP-388 components        thermal aging                                              IV.B2.RP-300 exposed to reactor embrittlement, coolant and        changes in neutron flux      dimensions due to void swelling, distortion, loss of preload due to 3.1-55 thermal and irradiation-enhanced stress relaxation or creep, loss of material due to wear M        059b        PWR      SS, including        Loss of fracture    AMP XI.M16A,    Yes (SRP-SLR        IV.B2.RP-274 CASS, PH SS or      toughness due to PWR Vessel        Section 3.1.2.2.9)  IV.B2.RP-280a martensitic SS      neutron irradiation Internals                          IV.B2.RP-287 Westinghouse        embrittlement and                                        IV.B2.RP-290 reactor internal    for CASS,                                                IV.B2.RP-290a Expansion          martensitic SS, and                                      IV.B2.RP-290b components          PH SS due to                                            IV.B2.RP-292 exposed to reactor  thermal aging                                            IV.B2.RP-295 coolant and          embrittlement;                                          IV.B2.RP-297a neutron flux        changes in                                              IV.B2.RP-388a dimensions due to void swelling, distortion; loss of
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                      Program (AMP)/                        Lessons Learned Modified,                                                                    Time-Limited        Further          for Subsequent Deleted,                                                        Aging        Aging Analyses      Evaluation        License Renewal Edited Item    ID        Type        Component        Effect/Mechanism        (TLAA)        Recommended        (GALL-SLR) Item preload due to thermal and irradiation-enhanced stress relaxation or creep; loss of material due to wear M        059c        PWR      SS, including        Loss of fracture    AMP XI.M16A,    Yes (SRP-SLR        IV.B2.RP-285 CASS, PH SS or      toughness due to PWR Vessel          Section 3.1.2.2.9)  IV.B2.RP-288 3.1-56 martensitic SS,      neutron irradiation Internals                            IV.B2.RP-299 nickel-alloy, or    embrittlement and                                          IV.B2.RP-345 stellite            for CASS, Westinghouse        martensitic SS, and reactor internal    PH SS due to Existing            thermal aging Programs            embrittlement, components          changes in exposed to reactor  dimensions due to coolant and          void swelling, neutron flux        distortion, loss of preload due to thermal and irradiation-enhanced stress relaxation or creep, loss of material due to wear
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                        Generic Aging New,                                                                      Program (AMP)/                    Lessons Learned Modified,                                                                      Time-Limited      Further      for Subsequent Deleted,                                                      Aging        Aging Analyses      Evaluation    License Renewal Edited Item    ID        Type        Component        Effect/Mechanism          (TLAA)      Recommended    (GALL-SLR) Item 060        BWR      Steel piping, piping Wall thinning due AMP XI.M17,        No              IV.C1.R-23 components          to flow-accelerated Flow-Accelerated exposed to reactor corrosion            Corrosion coolant 061        PWR      Steel SG steam    Wall thinning due AMP XI.M17,        No                IV.D1.R-37 nozzle and safe  to flow-accelerated Flow-Accelerated                    IV.D2.R-38 end, feedwater    corrosion          Corrosion nozzle and safe end, auxiliary 3.1-57 feedwater nozzles and safe ends exposed to secondary feedwater/steam 062      BWR/PWR      High-strength steel, Cracking due to        AMP XI.M18,            No      IV.A2.R-78 SS closure bolting; SCC                    Bolting Integrity            IV.C1.R-11 SS control rod                                                            IV.C2.R-11 drive head                                                                IV.D1.R-10 penetration flange                                                        IV.D2.R-10 bolting exposed to air-indoor uncontrolled 063        BWR      Steel or SS closure  Loss of material      AMP XI.M18,          No      IV.C1.RP-42 bolting exposed to    due to general        Bolting Integrity air - indoor          (steel only), pitting, uncontrolled          crevice corrosion, wear
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                        Program (AMP)/                      Lessons Learned Modified,                                                                      Time-Limited          Further      for Subsequent Deleted,                                                      Aging            Aging Analyses        Evaluation    License Renewal Edited Item    ID        Type          Component      Effect/Mechanism              (TLAA)        Recommended    (GALL-SLR) Item 064        PWR      Steel or SS closure Loss of material      AMP XI.M18,        No              IV.C2.RP-166 bolting exposed to due to general          Bolting Integrity                IV.D1.RP-166 air - indoor        (steel only), pitting,                                    IV.D2.RP-166 uncontrolled        crevice corrosion, wear 065        PWR      SS control rod      Loss of material      AMP XI.M18,        No              IV.A2.R-79 drive head          due to wear            Bolting Integrity penetration flange bolting exposed to 3.1-58 air-indoor uncontrolled 066        PWR      Steel, SS closure Loss of preload          AMP XI.M18,        No              IV.A2.R-80 bolting; SS control due to thermal        Bolting Integrity                IV.C2.R-12 rod drive head      effects, gasket penetration flange creep, self-bolting exposed to loosening air-indoor uncontrolled 067      BWR/PWR      Steel or SS closure  Loss of preload    AMP XI.M18,          No              IV.C1.RP-43 bolting exposed to    due to thermal    Bolting Integrity                  IV.D1.RP-46 air - indoor          effects, gasket                                          IV.D2.RP-46 uncontrolled          creep, self-(external)            loosening 068        PWR      Nickel-alloy SG      Changes in          AMP XI.M19,          No              IV.D1.R-43 tubes exposed to      dimension          Steam                              IV.D2.R-226 secondary            (denting) due to Generators, and feedwater or steam    corrosion of carbon
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                      Program (AMP)/                    Lessons Learned Modified,                                                                    Time-Limited          Further      for Subsequent Deleted,                                                        Aging        Aging Analyses        Evaluation  License Renewal Edited Item    ID        Type        Component          Effect/Mechanism        (TLAA)          Recommended    (GALL-SLR) Item steel tube support AMP XI.M2, Water plate              Chemistry 069        PWR      Nickel-alloy SG      Cracking due to      AMP XI.M19,      No            IV.D1.R-47 tubes and sleeves    outer diameter        Steam                          IV.D2.R-47 exposed to            SCC, intergranular    Generators, and secondary            attack                AMP XI.M2, Water feedwater or steam                          Chemistry 070        PWR      Nickel-alloy SG      Cracking due to  AMP XI.M19,      No                IV.D1.R-40 tubes, repair        primary water SCC Steam                              IV.D1.R-44 3.1-59                                      sleeves, and tube                      Generators, and                    IV.D2.R-40 plugs exposed to                        AMP XI.M2,                          IV.D2.R-44 reactor coolant                        Water Chemistry 071        PWR      Steel, chrome        Cracking due to      AMP XI.M19,      No            IV.D1.RP-226 plated steel, SS,    SCC or other          Steam                          IV.D1.RP-384 nickel-alloy SG U-    mechanism(s); loss    Generators, and bend supports        of material due      AMP XI.M2, including anti-      general (steel        Water Chemistry vibration bars        only), pitting, exposed to            crevice corrosion secondary feedwater or steam 072        PWR      Steel SG tube        Loss of material      AMP XI.M19,      No            IV.D1.R-42 support plate, tube  due to general,      Steam                          IV.D1.RP-161 bundle wrapper,      pitting, crevice      Generators, and                IV.D2.R-42 supports and          corrosion, erosion,  AMP XI.M2, Water                IV.D2.RP-162 mounting hardware    ligament cracking    Chemistry exposed to            due to corrosion      (corrosion based
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                  Program (AMP)/                          Lessons Learned Modified,                                                                Time-Limited              Further      for Subsequent Deleted,                                                    Aging      Aging Analyses              Evaluation  License Renewal Edited Item    ID        Type        Component      Effect/Mechanism      (TLAA)              Recommended    (GALL-SLR) Item secondary                          aging effects and feedwater or steam                  mechanisms only) 073        PWR      Nickel-alloy SG    Loss of material          AMP XI.M19,      No            IV.D1.R-50 tubes and sleeves due to wastage,            Steam exposed to        pitting corrosion        Generators, and phosphate                                    AMP XI.M2, Water chemistry in                                Chemistry secondary feedwater or steam 3.1-60                074        PWR      Steel SG upper      Wall thinning due        AMP XI.M19,      No            IV.D1.RP-49 assembly and        to flow-accelerated      Steam separators          corrosion                Generators, and including feedwater                          AMP XI.M2, Water inlet ring and                              Chemistry support exposed to secondary feedwater or steam 075        PWR      Steel SG tube          Wall thinning due    AMP XI.M19,      No            IV.D1.RP-48 support lattice bars  to flow-accelerated  Steam exposed to            corrosion, general    Generators, and secondary              corrosion            AMP XI.M2, Water feedwater or steam                          Chemistry 076        PWR      Steel, chrome      Loss of material          AMP XI.M19,      No              IV.D1.RP-225 plated steel, SS,  due to wear,              Steam nickel-alloy steam fretting                  Generators generator U-bend supports including
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                    Program (AMP)/                      Lessons Learned Modified,                                                                  Time-Limited          Further      for Subsequent Deleted,                                                      Aging      Aging Analyses        Evaluation  License Renewal Edited Item    ID        Type          Component        Effect/Mechanism    (TLAA)          Recommended    (GALL-SLR) Item anti-vibration bars exposed to secondary feedwater or steam 077        PWR      Nickel-alloy SG    Loss of material      AMP XI.M19,      No              IV.D1.RP-233 tubes and sleeves due to wear,          Steam                            IV.D2.RP-233 exposed to        fretting              Generators secondary feedwater or steam 3.1-61                078        PWR      Nickel-alloy SG    Cracking due to      AMP XI.M2, Water No              IV.D2.R-36 components such SCC                      Chemistry, and as, secondary side                      AMP XI.M32, nozzles (vent,                          One-Time drain, and                              Inspection, or instrumentation)                        AMP XI.M1, exposed to                              ASME Section XI secondary                                Inservice feedwater or steam                      Inspection, Subsections IWB, IWC, and IWD.
079        BWR      SS; steel with      Loss of material    AMP XI.M2,        No            IV.C1.RP-158 nickel-alloy or SS due to pitting,      Water Chemistry, cladding; and        crevice corrosion  and AMP XI.M32, nickel-alloy reactor                    One-Time coolant pressure                        Inspection boundary components
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                  Program (AMP)/                      Lessons Learned Modified,                                                                Time-Limited          Further      for Subsequent Deleted,                                                      Aging      Aging Analyses        Evaluation  License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)          Recommended    (GALL-SLR) Item exposed to reactor coolant 080        PWR      SS or steel with SS Cracking due to    AMP XI.M2,        No            IV.C2.RP-383 cladding            SCC                Water Chemistry, pressurizer relief                      and AMP XI.M32, tank: tank shell and                    One-Time heads, flanges,                        Inspection nozzles (none-ASME Section XI 3.1-62 components) exposed to treated borated water >60
                                            &deg;C (>140 &deg;F) 081        PWR      SS pressurizer    Cracking due to      AMP XI.M2,        No            IV.C2.RP-41 spray head        SCC                  Water Chemistry, exposed to reactor                      and AMP XI.M32, coolant                                One-Time Inspection 082        PWR      Nickel-alloy        Cracking due to    AMP XI.M2,        No            IV.C2.RP-40 pressurizer spray    SCC, primary      Water Chemistry, head exposed to      water SCC          and AMP XI.M32, reactor coolant                        One-Time Inspection 083        PWR      Steel SG shell      Loss of material  AMP XI.M2,        No            IV.D1.RP-372 assembly exposed    due to general,    Water Chemistry,                IV.D2.RP-153 to secondary        pitting, crevice  and AMP XI.M32, feedwater or steam  corrosion
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                        Generic Aging New,                                                                      Program (AMP)/                    Lessons Learned Modified,                                                                    Time-Limited        Further      for Subsequent Deleted,                                                      Aging        Aging Analyses      Evaluation  License Renewal Edited Item    ID        Type        Component          Effect/Mechanism      (TLAA)        Recommended    (GALL-SLR) Item One-Time Inspection 084        BWR      Steel top head        Loss of material  AMP XI.M2,        No            IV.A1.RP-50 enclosure (without    due to general,    Water Chemistry, cladding): top        pitting, crevice  and AMP XI.M32, head, top head        corrosion          One-Time nozzles (vent, top                      Inspection head spray, reactor core isolation 3.1-63 cooling, spare) exposed to reactor coolant 085        BWR      SS, nickel-alloy,    Loss of material    AMP XI.M2,        No            IV.A1.RP-157 and steel with      due to pitting,    Water Chemistry, nickel-alloy or SS crevice corrosion    and AMP XI.M32, cladding reactor                        One-Time vessel flanges,                          Inspection nozzles, penetrations, safe ends, vessel shells, heads and welds exposed to reactor coolant 086        PWR      SS or SG primary Cracking due to        AMP XI.M2,        No              IV.D1.RP-17 side divider plate SCC                  Water Chemistry exposed to reactor coolant
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                        Generic Aging New,                                                                      Program (AMP)/                    Lessons Learned Modified,                                                                    Time-Limited        Further      for Subsequent Deleted,                                                        Aging      Aging Analyses      Evaluation    License Renewal Edited Item    ID        Type          Component        Effect/Mechanism      (TLAA)        Recommended    (GALL-SLR) Item 087        PWR      SS, nickel-alloy      Loss of material  AMP XI.M2,        No              IV.B2.RP-24 PWR reactor            due to pitting,  Water Chemistry                IV.B3.RP-24 internal              crevice corrosion                                  IV.B4.RP-24 components exposed to reactor coolant, neutron flux 088        PWR      SS; steel with      Loss of material      AMP XI.M2,        No          IV.A2.RP-28 nickel-alloy or      due to pitting,        Water Chemistry              IV.C2.RP-23 3.1-64 stainless steel      crevice corrosion cladding; and nickel-alloy reactor coolant pressure boundary components exposed to reactor coolant E        089        PWR      Steel piping, piping  Loss of material    AMP XI.M21A,      No          IV.C2.RP-221 components            due to general,      Closed Treated exposed to closed-    pitting, crevice    Water Systems cycle cooling water    corrosion, microbiologically-induced corrosion (MIC) 090        PWR      Copper alloy          Loss of material    AMP XI.M21A,      No          IV.C2.RP-222 piping, piping        due to pitting,      Closed Treated components                                  Water Systems
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                  Program (AMP)/                        Lessons Learned Modified,                                                                Time-Limited            Further      for Subsequent Deleted,                                                    Aging      Aging Analyses          Evaluation  License Renewal Edited Item    ID        Type        Component        Effect/Mechanism      (TLAA)            Recommended    (GALL-SLR) Item exposed to closed- crevice corrosion, cycle cooling water MIC 091        BWR      Steel (including      Cracking due to      AMP XI.M3,      No              IV.A1.RP-165 high-strength steel)  SCC; loss of        Reactor Head                  IV.A1.RP-51 RV closure flange      material due to      Closure Stud assembly              general, pitting,    Bolting components            crevice corrosion, (including flanges,    wear nut, studs, and 3.1-65 washers) exposed to air-indoor uncontrolled 092        PWR      Steel (including      Cracking due to      AMP XI.M3,      No              IV.A2.RP-52 high-strength steel)  SCC, IGSCC; loss    Reactor Head                  IV.A2.RP-53 RV closure flange      of material due to  Closure Stud assembly              general, pitting,    Bolting components            crevice corrosion, (including flanges,    wear nut, studs, and washers) exposed to air-indoor uncontrolled 093        PWR      Copper alloy >15% Loss of material          AMP XI.M33,    No              IV.C2.RP-12 zinc or >8%        due to selective        Selective aluminum piping, leaching                  Leaching piping components exposed to closed-
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                  Program (AMP)/                    Lessons Learned Modified,                                                                Time-Limited          Further      for Subsequent Deleted,                                                      Aging      Aging Analyses        Evaluation  License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)          Recommended    (GALL-SLR) Item cycle cooling water, treated water 094        BWR      SS and nickel-alloy Cracking due to    AMP XI.M4, BWR No              IV.A1.R-64 vessel shell        SCC, IGSCC,        Vessel ID attachment welds cyclic loading        Attachment exposed to reactor                      Welds, and AMP coolant                                XI.M2, Water Chemistry 3.1-66 (SCC, IGSCC mechanisms only) 095        BWR      Steel (with or    Cracking due to      AMP XI.M1,        No            IV.A1.R-65 without SS or      cyclic loading      ASME Section XI nickel-alloy                            Inservice cladding)                              Inspection, feedwater nozzles                      Subsections IWB, exposed to reactor                      IWC, and IWD coolant 096        BWR      Steel (with or        Cracking due to  AMP XI.M1,      No              IV.A1.R-66 without SS            SCC, IGSCC,      ASME Section XI cladding) control    cyclic loading    Inservice rod drive return line                  Inspection, nozzles and their                      Subsections IWB, nozzle-to-vessel                        IWC, and IWD welds exposed to reactor coolant in BWR-3, BWR-4,
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                        Generic Aging New,                                                                Program (AMP)/                    Lessons Learned Modified,                                                              Time-Limited        Further      for Subsequent Deleted,                                                    Aging      Aging Analyses      Evaluation  License Renewal Edited Item    ID        Type        Component      Effect/Mechanism    (TLAA)        Recommended    (GALL-SLR) Item BWR-5, and BWR-6 designs E        097        BWR      SS and nickel-alloy Cracking due to  AMP XI.M7, BWR No              IV.A1.R-412 piping, piping      SCC, IGSCC        Stress Corrosion                IV.C1.R-20 components 4                        Cracking, and                  IV.C1.R-21 NPS; nozzle safe                      AMP XI.M2, ends and                              Water Chemistry associated welds, control rod drive 3.1-67 return line nozzle cap and associated cap-to-nozzle weld or cap-to-safe end weld in BWR-3, BWR 4, BWR 5, and BWR-6 designs 098        BWR      SS, nickel-alloy  Cracking due to    AMP XI.M8, BWR No              IV.A1.RP-369 penetrations:      SCC, IGSCC,        Penetrations, and instrumentation    cyclic loading    AMP XI.M2, and standby liquid                    Water Chemistry control exposed to                    (SCC, IGSCC reactor coolant                      mechanisms only)
M        099        BWR      SS (including      Loss of fracture  AMP XI.M9,    No              IV.B1.RP-182 CASS; PH          toughness due to  BWR Vessel                    IV.B1.RP-200 martensitic SS;    thermal aging,    Internals                      IV.B1.RP-219 martensitic SS);                                                      IV.B1.RP-220
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                        Generic Aging New,                                                                      Program (AMP)/                    Lessons Learned Modified,                                                                    Time-Limited        Further      for Subsequent Deleted,                                                      Aging        Aging Analyses      Evaluation    License Renewal Edited Item    ID        Type          Component        Effect/Mechanism        (TLAA)        Recommended    (GALL-SLR) Item nickel-alloy        neutron irradiation                                  IV.B1.R-416 (including X-750    embrittlement                                        IV.B1.R-417 alloy) reactor                                                            IV.B1.R-419 internal components exposed to reactor coolant and neutron flux 100        BWR      SS RVI              Loss of material  AMP XI.M9,        No              IV.B1.RP-377 3.1-68 components (jet      due to wear        BWR Vessel pump wedge                              Internals surface) exposed to reactor coolant 101        BWR      SS steam dryers    Cracking due to      AMP XI.M9,        No              IV.B1.RP-155 exposed to reactor flow-induced        BWR Vessel coolant            vibration, SCC,      Internals IGSCC; loss of material due to wear 102        BWR      SS fuel supports  Cracking due to      AMP XI.M9,        No              IV.B1.R-104 and control rod    SCC, IGSCC          BWR Vessel drive assemblies                        Internals, and control rod drive                      AMP XI.M2, housing exposed to                      Water Chemistry reactor coolant
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                  Program (AMP)/                    Lessons Learned Modified,                                                                Time-Limited        Further        for Subsequent Deleted,                                                    Aging      Aging Analyses      Evaluation    License Renewal Edited Item    ID        Type        Component      Effect/Mechanism      (TLAA)        Recommended      (GALL-SLR) Item M        103        BWR      SS, nickel-alloy  Cracking due to  AMP XI.M9, BWR No                IV.B1.R-422 reactor internal  SCC, IGSCC,      Vessel Internals,                IV.B1.R-100 components        IASCC            and AMP XI.M2,                    IV.B1.R-105 exposed to reactor                  Water Chemistry                  IV.B1.R-92 coolant and                                                            IV.B1.R-93 neutron flux                                                          IV.B1.R-96 IV.B1.R-97 IV.B1.R-98 IV.B1.R-99 3.1-69 104        BWR      Nickel-alloy RVI  Cracking due to  AMP XI.M9, BWR No                IV.B1.RP-381 components        IGSCC            Vessel Internals, exposed to reactor                  and AMP XI.M2, coolant and                          Water Chemistry neutron flux 105      BWR/PWR      Steel piping, piping None            None          Yes (SRP-SLR        IV.E.RP-353 components                                          Section 3.1.2.2.15) exposed to concrete 106      BWR/PWR      Nickel-alloy piping, None            None          No                IV.E.RP-378 piping components exposed to air with borated water leakage 107      BWR/PWR      SS piping, piping None              None          No                IV.E.RP-05 components                                                            IV.E.RP-07 exposed to gas, air
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                  Program (AMP)/                      Lessons Learned Modified,                                                                Time-Limited            Further      for Subsequent Deleted,                                                      Aging      Aging Analyses          Evaluation  License Renewal Edited Item    ID        Type          Component        Effect/Mechanism    (TLAA)            Recommended    (GALL-SLR) Item with borated water leakage 110        BWR      Metallic piping,  Wall thinning due      AMP XI.M17,      No            IV.C1.R-406 piping components to erosion              Flow-Accelerated exposed to reactor                        Corrosion coolant 111        PWR      Nickel-alloy SG    Reduction of heat      AMP XI.M2, Water No            IV.D1.R-407 tubes exposed to transfer due to          Chemistry, and                  IV.D2.R-407 secondary          fouling                AMP XI.M19, 3.1-70                                      feedwater or steam                        Steam Generators 113        BWR      Steel RV external    Loss of material    AMP XI.M1,        No            IV.A1.R-409 attachments          due to general,      ASME Section XI exposed to indoor,  pitting, crevice    Inservice uncontrolled air    corrosion, wear      Inspection, Subsections IWB, IWC, and IWD M        114      BWR/PWR      Reactor coolant      Cracking due to      AMP XI.M1,        No            IV.E.R-444 system              SCC, IGSCC,          ASME Section XI components          primary water        Inservice defined as ASME      stress corrosion    Inspection, Section XI Code      cracking (PWSCC),    Subsections IWB, Class components    IASCC (SCC          IWC, and IWD, (ASME Code Class    mechanisms for      and AMP XI.M2, 1 reactor coolant    SS, nickel-alloy    Water Chemistry pressure boundary    components only),    (water chemistry-components, RVI      fatigue, or cyclic  related or
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                            Generic Aging New,                                                                        Program (AMP)/                        Lessons Learned Modified,                                                                      Time-Limited        Further        for Subsequent Deleted,                                                      Aging          Aging Analyses        Evaluation      License Renewal Edited Item    ID        Type          Component      Effect/Mechanism            (TLAA)        Recommended      (GALL-SLR) Item attachments, or    loading; loss of      corrosion-related core support        material due to      aging effect structure          general corrosion mechanisms only) components; or      (steel only), pitting ASME Class 2 or 3 corrosion, crevice components        corrosion, or wear including ASME defined appurtenances, 3.1-71 component supports, and associated pressure boundary welds, or components subject to plant-specific equivalent classifications for these ASME Code classes) 115      BWR/PWR      SS piping, piping  None                None                  Yes (SRP-SLR        IV.E.RP-06 components                                                    Section 3.1.2.2.15) exposed to concrete 116        PWR      Nickel-alloy control Loss of material  Plant-specific aging Yes (SRP-SLR        IV.A2.R-413 rod drive            due to wear        management          Section penetration nozzles                    program              3.1.2.2.10.1)
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                      Generic Aging New,                                                                  Program (AMP)/                                  Lessons Learned Modified,                                                                Time-Limited                  Further          for Subsequent Deleted,                                                      Aging      Aging Analyses                Evaluation        License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)                  Recommended        (GALL-SLR) Item exposed to reactor coolant 117        PWR      SS, nickel-alloy  Loss of material        Plant-specific aging Yes (SRP-SLR          IV.A2.R-414 control rod drive  due to wear            management          Section penetration nozzle                        program              3.1.2.2.10.2) thermal sleeves exposed to reactor coolant M        118        PWR      SS, nickel-alloy    Cracking due to      Plant-specific aging Yes (SRP-SLR          IV.B2.R-423 3.1-72                                      PWR RVI              SCC, IASCC,          management            Section 3.1.2.2.9)  IV.B3.R-423 components or        cyclic loading,      program or AMP                            IV.B4.R-423 license renewal      fatigue              XI.M16A, PWR applications                              Vessel Internals, (LRA)/subsequent                          and AMP XI.M2, license renewal                            Water Chemistry application (SLRA)                        (SCC and IASCC specified RVI                              only), with an component                                  adjusted site-exposed to reactor                        specific or coolant, neutron                          component-specific flux                                      aging management basis for a specified RVI component M        119        PWR      SS, nickel-alloy,    Loss of fracture      Plant-specific aging Yes (SRP-SLR          IV.B2.R-424 stellite PWR RVI    toughness due to      management          Section 3.1.2.2.9)    IV.B3.R-424 components or        neutron irradiation  program or AMP                            IV.B4.R-424 LRA/SLRA-            embrittlement or      XI.M16A, PWR
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                          Generic Aging New,                                                                      Program (AMP)/                      Lessons Learned Modified,                                                                      Time-Limited          Further      for Subsequent Deleted,                                                      Aging          Aging Analyses        Evaluation    License Renewal Edited Item    ID        Type          Component    Effect/Mechanism            (TLAA)          Recommended    (GALL-SLR) Item specified RVI      thermal aging        Vessel Internals, component          embrittlement;      with an adjusted exposed to reactor changes in          site-specific or coolant, neutron  dimensions due to component-specific flux              void swelling or    aging management distortion; loss of basis for a specified preload due to      reactor vessel thermal and          internal component irradiation-3.1-73 enhanced stress relaxation or creep; loss of material due to wear 120        BWR      SS core plate rim    Loss of preload    AMP XI.M9, BWR Yes (SRP-SLR          IV.B1.R-420 holddown bolts      due to thermal or  Vessel Internals, Section 3.1.2.2.14) exposed to reactor  irradiation-        and TLAA SRP-coolant and          enhanced stress    SLR 4.7 Other neutron flux        relaxation          Plant-Specific TLAAs [if an analysis is performed as part of the aging management basis and conforms to the definition of a TLAA in 10 CFR 54.3(a)]
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                      Generic Aging New,                                                                    Program (AMP)/                  Lessons Learned Modified,                                                                  Time-Limited      Further      for Subsequent Deleted,                                                      Aging      Aging Analyses    Evaluation    License Renewal Edited Item    ID        Type          Component      Effect/Mechanism        (TLAA)      Recommended    (GALL-SLR) Item 121        BWR      SS jet pump        Loss of preload  AMP XI.M9,      No              IV.B1.R-421 assembly            due to thermal or BWR Vessel holddown beam      irradiation-      Internals bolts exposed to    enhanced stress reactor coolant and relaxation neutron flux D        122 124      BWR/PWR      Steel piping, piping  Loss of material  AMP XI.M36,        No        IV.C1.R-431 components            due to general,    External Surfaces          IV.C2.R-431 3.1-74                                      exposed to air-        pitting, crevice  Monitoring of indoor                corrosion          Mechanical uncontrolled, air                        Components outdoor, condensation 125        PWR      Nickel-alloy SG        Cracking due to    AMP XI.M19,      No        IV.D1.R-437 tubes at support      flow-induced      Steam Generators            IV.D2.R-442 plate locations        vibration, high-exposed to            cycle fatigue secondary feedwater or steam 127        PWR      Steel (with SS or  Loss of material      AMP XI.M2, Water No        IV.D1.R-436 nickel-alloy      due to boric acid      Chemistry, and              IV.D2.R-440 cladding) SG      corrosion              AMP XI.M19, heads and                                Steam tubesheets                                Generators exposed to reactor coolant
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                      Generic Aging New,                                                                    Program (AMP)/                  Lessons Learned Modified,                                                                  Time-Limited      Further      for Subsequent Deleted,                                                      Aging      Aging Analyses    Evaluation    License Renewal Edited Item    ID        Type          Component        Effect/Mechanism      (TLAA)      Recommended    (GALL-SLR) Item 128        BWR      SS, nickel-alloy    Cracking due to  AMP XI.M7, BWR No              IV.A1.R-68 nozzles safe ends SCC, IGSCC          Stress Corrosion and welds: high                      Cracking, and pressure core                        AMP XI.M2, spray; low pressure                  Water Chemistry core spray; recirculating water, low pressure coolant injection or 3.1-75 RHR injection mode exposed to reactor coolant 129        BWR      Steel and SS        Cracking due to  AMP XI.M1,      No            IV.C1.R-432 piping, piping      cyclic loading    ASME Section XI components                            Inservice exposed to reactor                    Inspection, coolant: welded                        Subsections IWB, connections                            IWC, and IWD between the re-routed control rod drive return line and the inlet piping system that delivers return line flow to the reactor pressure vessel exposed to reactor coolant
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                      Generic Aging New,                                                                  Program (AMP)/                                Lessons Learned Modified,                                                                Time-Limited                Further            for Subsequent Deleted,                                                      Aging      Aging Analyses              Evaluation        License Renewal Edited Item    ID        Type        Component        Effect/Mechanism    (TLAA)                Recommended          (GALL-SLR) Item D        130 133      BWR/PWR      Steel components Long-term loss of        AMP XI.M32,        No                    IV.A1.R-448 exposed to treated material due to        One-Time                                  IV.C1.R-448 water              general corrosion      Inspection 134      BWR/PWR      Nonmetallic          Reduced thermal      AMP XI.M36,        No                      IV.A1.R-450 thermal insulation  insulation          External Surfaces                        IV.A2.R-450 exposed to air,      resistance due to    Monitoring of                              IV.C1.R-450 condensation        moisture intrusion  Mechanical                                IV.C2.R-450 Components                                IV.D1.R-450 3.1-76                                                                                                                            IV.D2.R-450 D        135 136      BWR/PWR      SS, nickel-alloy    Loss of material    AMP XI.M32,          Yes (SRP-SLR          IV.C1.R-452a piping, piping      due to pitting,      One-Time            Section 3.1.2.2.16)  IV.C1.R-452b components          crevice corrosion    Inspection, AMP                          IV.C1.R-452c exposed to air,                          XI.M36, External                          IV.C1.R-452d condensation                              Surfaces                                  IV.C2.R-452a Monitoring of                              IV.C2.R-452b Mechanical                                IV.C2.R-452c Components,                              IV.C2.R-452d AMP XI.M38, Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components, or AMP XI.M42, Internal
 
Table 3.1-1  Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                              Generic Aging New,                                                                    Program (AMP)/                          Lessons Learned Modified,                                                                  Time-Limited          Further          for Subsequent Deleted,                                                    Aging        Aging Analyses        Evaluation      License Renewal Edited Item    ID        Type        Component        Effect/Mechanism        (TLAA)          Recommended        (GALL-SLR) Item Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 137      BWR/PWR      Copper alloy        None              None              No                  IV.E.R-453 piping, piping components 3.1-77 exposed to air, condensation, gas 139        PWR      SS, nickel-alloy RV Cracking due to    AMP XI.M32,        Yes (SRP-SLR        IV.A2.R-74a top head enclosure SCC                One-Time          Section 3.1.2.2.6.3) IV.A2.R-74b flange leakage                        Inspection, or detection line                        AMP XI.M36, exposed to air-                        External Surfaces indoor                                Monitoring of uncontrolled,                          Mechanical reactor coolant                        Components leakage N        140      BWR/PWR    Steel, SS or nickel- Cracking due to  Plant-specific aging Yes (SRP-SLR        IV.C1.R-456 alloy piping, piping thermal fatigue  management          Section 3.1.2.2.17) IV.C2.R-456 components                            program exposed to reactor coolant
 
Table 3.1-1      Summary of Aging Management Programs for Reactor Vessel, Internals, and Reactor Coolant System Evaluated in Chapter IV of the GALL-SLR Report (Continued)
Aging Management                                      Generic Aging New,                                                                              Program (AMP)/                                  Lessons Learned Modified,                                                                            Time-Limited          Further                  for Subsequent Deleted,                                                                Aging      Aging Analyses        Evaluation                License Renewal Edited Item      ID          Type              Component        Effect/Mechanism        (TLAA)        Recommended                  (GALL-SLR) Item N          141        BWR/PWR          Steel, SS or nickel- Loss of material Plant-specific or  Yes (SRP-SLR                  IV.A1.R-457 alloy ASME Code due to wear          existing aging    Section                      IV.A2.R-457 Class 1 small-bore                    management        3.1.2.2.10.3) piping, and piping                    program if loss of components with                      material is not reflective metal                      mitigated insulation exposed to air 1  AMP = aging management program; ASME = American Society of Mechanical Engineers; B&W = Babcock and Wilcox; BWR = boiling water reactor; CASS = cast 3.1-78 2  austenitic stainless steel; CE = Combustion Engineering; GALL-SLR = Generic Aging Lessons Learned for Subsequent License Renewal; IASCC = irradiation-3  assisted SCC; IGSCC = intergranular stress corrosion cracking; LRA = license renewal applications; MIC = microbiologically-induced corrosion; NPS = nominal 4  pipe size; PH = precipitation-hardening; PWR = pressure water reactor; PWSCC = primary water stress corrosion cracking; RCPB = reactor coolant pressure 5  boundary; RV = reactor vessel; RVI = reactor vessel internal; SCC = stress corrosion cracking; SG = steam generator; SLRA = subsequent license renewal 6  application; SRP-SLR = Standard Review Plan for Review of Subsequent License Renewal; SS = stainless steel; TLAA = time-limited aging analyses.
7 8
 
1  Table 3.2-1    Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the 2                  Generic Aging Lessons Learned for Subsequent License Renewal Report New,                                                                          Aging Management                        Generic Aging Modified,                                                                            Program                          Lessons Learned Deleted,                                                                            (AMP)/Time-                        for Subsequent Edited                                                        Aging Effect/      Limited Aging    Further Evaluation License Renewal Item        ID        Type            Component              Mechanism        Analyses (TLAA)    Recommended              Item 001    Boiling water  Stainless steel (SS), Cumulative fatigue  TLAA, Standard    Yes (SRP-SLR      V.D1.E-13 reactor (BWR)/  steel piping, piping  damage due to        Review Plan for    Section 3.2.2.1)  V.D2.E-10 pressurized    components            fatigue              Review of water reactor  exposed to any                            Subsequent License (PWR)        environment                                Renewal (SRP-SLR)
Section 4.3 Metal Fatigue D            002 3.2-21 D            003 004    BWR/PWR        SS, nickel-alloy    Loss of material due AMP XI.M32,          Yes (SRP-SLR        V.B.EP-107a piping, piping      to pitting, crevice  "One-Time            Section 3.2.2.2.2)  V.B.EP-107b components          corrosion            Inspection," AMP                          V.B.EP-107d exposed to air,                          XI.M36, "External                        V.C.EP-107a condensation                              Surfaces Monitoring                      V.C.EP-107b (external)                                of Mechanical                            V.C.EP-107d Components," or                          V.D1.EP-107a AMP XI.M42,                              V.D1.EP-107b "Internal                                V.D1.EP-107d Coatings/Linings for                      V.D2.EP-107a In-Scope Piping,                          V.D2.EP-107b Piping Components,                        V.D2.EP-107d Heat Exchangers, and Tanks" 3
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                    Aging Management                        Generic Aging Modified,                                                                        Program                        Lessons Learned Deleted,                                                                        (AMP)/Time-                        for Subsequent Edited                                                  Aging Effect/      Limited Aging  Further Evaluation License Renewal Item      ID      Type          Component              Mechanism        Analyses (TLAA)  Recommended              Item E          005      PWR      SS orifice (miniflow  Loss of material due AMP XI.M32,      No                V.D1.E-24 recirculation when    to erosion          One-Time centrifugal high-                          Inspection pressure safety injection (HPSI) pumps are used for normal charging) exposed to treated borated water 006      BWR      Metallic drywell and  Loss of material due  AMP XI.M32,            Yes (SRP-SLR        V.D2.EP-113a 3.2-22 suppression            to general, pitting,  One-Time              Section 3.2.2.2.3)  V.D2.EP-113b chamber spray          crevice corrosion;    Inspection, or AMP system (internal      flow blockage due to  XI.M38, Inspection surfaces): flow        fouling                of Internal Surfaces orifice; spray                                in Miscellaneous nozzles exposed to                            Piping and Ducting air - indoor                                  Components uncontrolled, condensation 007      BWR      SS piping, piping      Cracking due to        AMP XI.M32, One-      Yes (SRP-SLR        V.A.EP-103b components, tanks      stress corrosion      Time Inspection,      Section 3.2.2.2.4)  V.A.EP-103c exposed to air,        cracking (SCC)        AMP XI.M36,                                V.A.EP-103d condensation                                  External Surfaces                          V.A.EP-103e Monitoring                                  V.B.EP-103b of Mechanical                              V.B.EP-103c Components, AMP                            V.B.EP-103d XI.M38, Inspection                        V.B.EP-103e of Internal Surfaces                        V.C.EP-103b in Miscellaneous                            V.C.EP-103c
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                            Generic Aging Modified,                                                                        Program                              Lessons Learned Deleted,                                                                        (AMP)/Time-                            for Subsequent Edited                                                    Aging Effect/      Limited Aging    Further Evaluation    License Renewal Item        ID      Type          Component            Mechanism          Analyses (TLAA)    Recommended                Item Piping and Ducting                        V.C.EP-103d Components, or                          V.C.EP-103e AMP XI.M42,                              V.D1.EP-103b Internal                                V.D1.EP-103c Coatings/Linings for                      V.D1.EP-103d In-Scope Piping,                          V.D1.EP-103e Piping Components,                        V.D2.EP-103b Heat Exchangers,                          V.D2.EP-103c and Tanks                                V.D2.EP-103d V.D2.EP-103e 3.2-23 008        PWR      Copper alloy (>15%    Loss of material due AMP XI.M10,        No                    V.E.EP-38 Zinc) piping, piping  to boric acid        Boric Acid components            corrosion            Corrosion exposed to air with borated water leakage 009        PWR      Steel external        Loss of material due AMP XI.M10,        No                    V.E.E-28 surfaces exposed to    to boric acid        Boric Acid air with borated      corrosion            Corrosion water leakage 010      BWR/PWR    Cast austenitic        Loss of fracture    AMP XI.M12,        No                    V.D1.E-47 stainless steel        toughness due to    Thermal Aging                            V.D2.E-11 (CASS) piping,        thermal aging      Embrittlement of piping components      embrittlement      Cast Austenitic exposed to treated                        Stainless Steel borated water >250                        (CASS)
                                          &deg;C (>482 &deg;F),
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                          Aging Management                        Generic Aging Modified,                                                                            Program                          Lessons Learned Deleted,                                                                            (AMP)/Time-                          for Subsequent Edited                                                    Aging Effect/          Limited Aging  Further Evaluation    License Renewal Item        ID      Type          Component              Mechanism            Analyses (TLAA)  Recommended                Item treated water >250
                                          &deg;C (>482 &deg;F)
E          011      BWR/PWR    Steel piping, piping    Wall thinning due to    AMP XI.M17, Flow    No              V.C.E-09 components              flow-accelerated        Accelerated                          V.D1.E-09 exposed to steam,      corrosion              Corrosion                            V.D2.E-07 treated water                                                                        V.D2.E-09 012      BWR/PWR    High-strength steel    Cracking due to        AMP XI.M18,          No              V.E.E-03 closure bolting        SCC; cyclic            Bolting Integrity exposed to air, soil,  loading underground 3.2-24  D          013 014      BWR/PWR    SS, steel, nickel-      Loss of material due AMP XI.M18,              No              V.E.E-02 alloy closure bolting  to general (steel      Bolting Integrity exposed to air-        only), pitting, crevice indoor uncontrolled,    corrosion air outdoor, condensation 015      BWR/PWR    Metallic closure        Loss of preload due    AMP XI.M18,          No              V.E.EP-116 bolting exposed to      to thermal effects,    Bolting Integrity any environment,        gasket creep, self-soil underground        loosening E          016      BWR/PWR    Steel piping, piping    Loss of material due    AMP XI.M2, Water    No              V.C.EP-62 components              to general, pitting,    Chemistry, and                      V.D2.EP-60 exposed to treated      crevice corrosion,      AMP XI.M32, One-water                  microbiologically-      Time Inspection induced corrosion (MIC)
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                        Generic Aging Modified,                                                                          Program                        Lessons Learned Deleted,                                                                        (AMP)/Time-                        for Subsequent Edited                                                    Aging Effect/      Limited Aging  Further Evaluation License Renewal Item      ID      Type          Component                Mechanism        Analyses (TLAA)    Recommended              Item E          017    BWR/PWR    Aluminum piping,        Loss of material due AMP XI.M2, Water No                V.D1.EP-71 piping components      to pitting, crevice  Chemistry, and                      V.D2.EP-71 exposed to treated      corrosion            AMP XI.M32, One-water, treated                              Time Inspection borated water D          018 M          019    BWR/PWR    Stainless steel,        Reduction of heat    AMP XI.M2, Water    No            V.A.E-20 nickel-alloy heat      transfer due to      Chemistry, and                    V.D2.EP-74 exchanger tubes        fouling              AMP XI.M32, One-                  V.D1.E-20 exposed to treated                          Time Inspection 3.2-25 water, treated borated water 020      PWR      SS, steel (with SS or  Cracking due to      AMP XI.M2, Water    No            V.A.E-12 nickel-alloy            SCC                  Chemistry, and                    V.D1.E-12 cladding) piping,                            AMP XI.M32, One-piping components,                          Time Inspection tanks exposed to treated borated water >60 &deg;C
(>140 &deg;F)
D          021 022    BWR/PWR    Nickel-alloy, SS heat Loss of material due  AMP XI.M2,          No            V.A.E-428 exchanger            to pitting, crevice    Water Chemistry,                  V.A.EP-41 components, piping, corrosion, MIC          and AMP XI.M32,                    V.C.EP-63 piping components,                          One-Time                          V.D1.E-428 tanks exposed to                            Inspection                        V.D2.E-428 treated water,                                                                  V.D1.EP-41 V.D2.EP-73
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                        Aging Management                        Generic Aging Modified,                                                                          Program                          Lessons Learned Deleted,                                                                        (AMP)/Time-                        for Subsequent Edited                                                  Aging Effect/        Limited Aging  Further Evaluation  License Renewal Item        ID      Type          Component            Mechanism            Analyses (TLAA)  Recommended                Item treated borated water 023      BWR/PWR    Steel heat            Loss of material due AMP XI.M20, Open No                    V.A.EP-90 exchanger            to general, pitting, Cycle Cooling Water                    V.C.E-22 components, piping,  crevice corrosion,  System                                V.D1.EP-90 piping components    MIC; flow blockage                                          V.D2.EP-90 exposed to raw        due to fouling water 024        PWR      SS piping, piping    Loss of material due  AMP XI.M20, Open No                  V.C.E-34 components            to pitting, crevice    Cycle Cooling Water                  V.D1.EP-55 3.2-26 exposed to raw        corrosion, MIC; flow  System water                blockage due to fouling 025      BWR/PWR    SS heat exchanger    Loss of material due  AMP XI.M20, Open No                  V.A.EP-91 components            to pitting, crevice    Cycle Cooling Water                  V.D1.EP-91 exposed to raw        corrosion, MIC; flow  System                              V.D2.EP-91 water                blockage due to fouling D          026 027      BWR/PWR    SS, steel heat        Reduction of heat      AMP XI.M20, Open No                  V.A.E-21 exchanger tubes      transfer due to        Cycle Cooling Water                  V.D1.E-21 exposed to raw        fouling                System                              V.D2.E-21 water                                                                              V.D2.E-23 028      BWR/PWR    SS piping, piping    Cracking due to        AMP XI.M21A,      No                  V.A.EP-98 components            SCC                    Closed Treated                      V.C.EP-98 exposed to closed-                          Water Systems                        V.D1.EP-98 cycle cooling water                                                                V.D2.EP-98
                                          >60 &deg;C (>140 &deg;F)
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                    Aging Management                        Generic Aging Modified,                                                                      Program                          Lessons Learned Deleted,                                                                      (AMP)/Time-                        for Subsequent Edited                                                  Aging Effect/      Limited Aging Further Evaluation    License Renewal Item      ID      Type          Component            Mechanism        Analyses (TLAA)  Recommended                Item 029    BWR/PWR    Steel piping, piping Loss of material due AMP XI.M21A,    No                  V.C.EP-99 components          to general, pitting, Closed Treated exposed to closed-  crevice corrosion,  Water Systems cycle cooling water  MIC 030    BWR/PWR    Steel heat          Loss of material due AMP XI.M21A,    No                  V.A.EP-92 exchanger            to general, pitting, Closed Treated                      V.D1.EP-92 components          crevice corrosion,  Water Systems                        V.D2.EP-92 exposed to closed-  MIC cycle cooling water 031    BWR/PWR    SS heat exchanger Loss of material due AMP XI.M21A,        No                  V.A.EP-93 3.2-27 components, piping, to pitting, crevice Closed Treated                        V.A.EP-95 piping components corrosion, MIC        Water Systems                          V.C.EP-95 exposed to closed-                                                              V.D1.EP-93 cycle cooling water                                                            V.D1.EP-95 V.D2.EP-93 V.D2.EP-95 032    BWR/PWR    Copper alloy heat  Loss of material due AMP XI.M21A,      No                  V.A.EP-94 exchanger          to pitting, crevice  Closed Treated                        V.A.EP-97 components, piping, corrosion, MIC      Water Systems                        V.B.EP-97 piping components                                                              V.D1.EP-94 exposed to closed-                                                              V.D1.EP-97 cycle cooling water                                                            V.D2.EP-94 V.D2.EP-97 033    BWR/PWR    Copper alloy, SS    Reduction of heat  AMP XI.M21A,      No                  V.A.EP-100 heat exchanger      transfer due to    Closed Treated                        V.A.EP-96 tubes exposed to    fouling            Water Systems                        V.D1.EP-96 closed-cycle cooling                                                            V.D2.EP-96 water
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                          Generic Aging Modified,                                                                          Program                            Lessons Learned Deleted,                                                                        (AMP)/Time-                          for Subsequent Edited                                                    Aging Effect/        Limited Aging    Further Evaluation License Renewal Item      ID      Type          Component              Mechanism          Analyses (TLAA)      Recommended              Item 034    BWR/PWR    Copper alloy (>15%    Loss of material due AMP XI.M33,          No                V.A.EP-27 zinc or >8%            to selective leaching Selective Leaching                    V.A.EP-37 aluminum) piping,                                                                    V.B.EP-27 piping components,                                                                  V.B.EP-37 heat exchanger                                                                      V.D1.EP-27 components                                                                          V.D1.EP-37 exposed to closed-                                                                  V.D2.EP-27 cycle cooling water,                                                                V.D2.EP-37 treated water 035      PWR      Gray cast iron motor  Loss of material due AMP XI.M33,          No              V.A.E-43 3.2-28 cooler exposed to      to selective leaching Selective Leaching                  V.D1.E-43 closed-cycle cooling water, treated water M          036      PWR      Gray cast iron,        Loss of material due AMP XI.M33,          No              V.D1.EP-52 ductile iron,          to selective leaching Selective Leaching malleable iron piping, piping components exposed to closed-cycle cooling water, treated water M          037    BWR/PWR    Gray cast iron,        Loss of material due AMP XI.M33,          No              V.B.EP-54 ductile iron,          to selective leaching Selective Leaching                  V.D1.EP-54 malleable iron                                                                    V.D2.EP-54 piping, piping components exposed to soil
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                    Aging Management                        Generic Aging Modified,                                                                        Program                          Lessons Learned Deleted,                                                                      (AMP)/Time-                        for Subsequent Edited                                                  Aging Effect/        Limited Aging  Further Evaluation License Renewal Item      ID      Type          Component            Mechanism        Analyses (TLAA)    Recommended              Item 038    BWR/PWR    Elastomer piping,    Hardening or loss of AMP XI.M36,        No                V.E.EP-59 piping components, strength due to        External Surfaces seals exposed to air, elastomer            Monitoring of condensation          degradation          Mechanical Components D          039 040    BWR/PWR    Steel external      Loss of material due    AMP XI.M36,          No                    V.E.E-44 surfaces exposed to to general, pitting,    External Surfaces air - indoor        crevice corrosion        Monitoring of uncontrolled, air -                          Mechanical 3.2-29 outdoor,                                    Components condensation D          041 042    BWR/PWR    Aluminum piping,      Loss of material due  AMP XI.M32,          Yes (SRP-SLR          V.E.EP-114b piping components, to pitting, crevice      One-Time            Section 3.2.2.2.10)  V.E.EP-114c tanks exposed to air, corrosion              Inspection, AMP                          V.E.EP-114d condensation                                XI.M36, External (external)                                  Surfaces Monitoring of Mechanical Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                        Aging Management                            Generic Aging Modified,                                                                            Program                              Lessons Learned Deleted,                                                                          (AMP)/Time-                            for Subsequent Edited                                                    Aging Effect/        Limited Aging      Further Evaluation License Renewal Item      ID      Type          Component              Mechanism            Analyses (TLAA)        Recommended              Item M          043    BWR/PWR    Elastomer piping,      Hardening or loss of  AMP XI.M38,            No                V.B.EP-58 piping components,      strength due to        Inspection of                            V.A.E-427 seals exposed to air,  elastomer              Internal Surfaces in                      V.B.E-427 condensation            degradation            Miscellaneous                            V.D1.E-427 Piping and Ducting                        V.D2.E-427 Components M          044    BWR/PWR    Steel piping, piping    Loss of material due  AMP XI.M38,            No                V.A.E-29 components,            to general, pitting,  Inspection of                          V.B.E-25 ducting, ducting        crevice corrosion      Internal Surfaces in                    V.D2.E-29 components                                    Miscellaneous 3.2-30 exposed to air -                              Piping and Ducting indoor uncontrolled                            Components 045      PWR      Steel encapsulation    Loss of material due  AMP XI.M38,            No                V.A.EP-42 components              to general, pitting,  Inspection of                          V.C.EP-42 exposed to air -        crevice corrosion      Internal Surfaces in                    V.D1.EP-42 indoor uncontrolled                            Miscellaneous Piping and Ducting Components 046    BWR/PWR    Steel piping, piping    Loss of material due  AMP XI.M38,            No                V.B.E-27 components              to general, pitting,  Inspection of                          V.D1.E-27 exposed to              crevice corrosion      Internal Surfaces in                    V.D2.E-27 condensation                                  Miscellaneous Piping and Ducting Components 047      PWR      Steel encapsulation    Loss of material due  AMP XI.M38,            No                V.A.EP-43 components              to general, pitting,  Inspection of                          V.C.EP-43 exposed to air with    crevice, boric acid    Internal Surfaces in                    V.D1.EP-43 corrosion              Miscellaneous
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                              Generic Aging Modified,                                                                          Program                              Lessons Learned Deleted,                                                                        (AMP)/Time-                              for Subsequent Edited                                                    Aging Effect/      Limited Aging      Further Evaluation  License Renewal Item        ID      Type          Component              Mechanism        Analyses (TLAA)      Recommended                Item borated water                              Piping and Ducting leakage                                    Components E          048      BWR/PWR    SS, nickel-alloy      Loss of material due AMP XI.M29,            Yes (SRP-SLR        V.A.EP-81a piping, piping        to pitting, crevice  Outdoor and Large    Section 3.2.2.2.2)  V.A.EP-81b components, tanks      corrosion            Atmospheric Metallic                        V.A.EP-81c exposed to air,                            Storage Tanks,                            V.A.EP-81d condensation                                AMP XI.M32, One-                          V.D1.EP-81a (internal)                                  Time Inspection,                          V.D1.EP-81b AMP XI.M38,                                V.D1.EP-81c Inspection of                              V.D1.EP-81d 3.2-31 Internal Surfaces in                        V.D2.EP-61a Miscellaneous                              V.D2.EP-61b Piping and Ducting                          V.D2.EP-61c Components, or                            V.D2.EP-61d AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks E          049      BWR/PWR    Steel piping, piping  Loss of material due AMP XI.M39,            No                  V.A.EP-77 components            to general, pitting, Lubricating Oil                            V.D1.EP-77 exposed to            crevice corrosion,  Analysis, and AMP                          V.D2.EP-77 lubricating oil        MIC                  XI.M32, One-Time Inspection
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                          Generic Aging Modified,                                                                          Program                            Lessons Learned Deleted,                                                                        (AMP)/Time-                          for Subsequent Edited                                                    Aging Effect/      Limited Aging  Further Evaluation    License Renewal Item      ID        Type          Component              Mechanism        Analyses (TLAA)    Recommended                Item E          050      BWR/PWR    Copper alloy,          Loss of material due AMP XI.M39,        No                  V.A.EP-76 stainless steel        to pitting, crevice  Lubricating Oil                        V.D1.EP-76 piping, piping        corrosion, MIC      Analysis, and AMP                      V.D1.EP-80 components                                  XI.M32, One-Time                      V.D2.EP-76 exposed to                                  Inspection lubricating oil 051      BWR/PWR    Steel, copper alloy,  Reduction of heat      AMP XI.M39,          No              V.A.EP-75 stainless steel heat  transfer due to        Lubricating Oil                      V.A.EP-78 exchanger tubes        fouling                Analysis, and AMP                    V.A.EP-79 exposed to                                    XI.M32, One-Time                    V.D1.EP-75 3.2-32 lubricating oil                              Inspection                          V.D1.EP-78 V.D1.EP-79 V.D2.EP-75 V.D2.EP-78 V.D2.EP-79 052      BWR/PWR    Steel piping, piping  Loss of material due  AMP XI.M41,        No                V.E.EP-111 components            to general, pitting,  Buried and                          V.E.EP-123 exposed to soil,      crevice corrosion,    Underground Piping concrete,              MIC (soil only)        and Tanks underground 053      BWR/PWR    SS, nickel-alloy      Loss of material due  AMP XI.M41,        No                V.E.EP-72 piping, piping        to pitting, crevice    Buried and components, tanks,    corrosion, MIC (soil  Underground Piping exposed to soil,      only)                  and Tanks concrete D          053a E            054      BWR      SS, nickel-alloy      Cracking due to        AMP XI.M7, BWR      No              V.D2.E-37 piping, piping        SCC, intergranular    Stress Corrosion
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                          Generic Aging Modified,                                                                          Program                            Lessons Learned Deleted,                                                                        (AMP)/Time-                          for Subsequent Edited                                                      Aging Effect/      Limited Aging  Further Evaluation    License Renewal Item        ID      Type          Component              Mechanism        Analyses (TLAA)    Recommended                Item components 4          stress corrosion    Cracking, and AMP nominal pipe size      cracking (IGSCC)    XI.M2, Water exposed to treated                          Chemistry water >93 &deg;C (>200
                                          &deg;F) 055      BWR/PWR    Steel piping, piping    None                None              Yes (SRP-SLR          V.F.EP-112 components                                                    Section 3.2.2.2.9) exposed to concrete 056      BWR/PWR    Aluminum piping,    Loss of material due AMP XI.M32, One- Yes (SRP-SLR            V.A.EP-3b piping components,  to pitting, crevice  Time Inspection,    Section 3.2.2.2.10)  V.A.EP-3c 3.2-33 tanks exposed to air,corrosion            AMP XI.M38,                                V.A.EP-3d condensation                              Inspection of                            V.D1.EP-3b (internal)                                Internal Surfaces in                      V.D1.EP-3c Miscellaneous                              V.D1.EP-3d Piping and Ducting                        V.D2.EP-3b Components, or                            V.D2.EP-3c AMP XI.M42,                                V.D2.EP-3d Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 057      BWR/PWR    Copper alloy piping, None                None                No                    V.F.EP-10 piping components exposed to air, condensation, gas
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                  Aging Management                      Generic Aging Modified,                                                                    Program                        Lessons Learned Deleted,                                                                  (AMP)/Time-                        for Subsequent Edited                                                Aging Effect/    Limited Aging  Further Evaluation License Renewal Item      ID      Type          Component          Mechanism      Analyses (TLAA)  Recommended              Item 058      PWR      Copper alloy, copper None              None            No                V.F.EP-12 alloy (>8%
aluminum) piping, piping components exposed to air with borated water leakage 059    BWR/PWR    Galvanized steel      None              None            No                V.F.EP-14 ducting, ducting components, piping, 3.2-34 piping components exposed to air -
indoor controlled 060    BWR/PWR    Glass piping          None              None            No                V.F.EP-15 elements exposed to                                                        V.F.EP-16 air, underground,                                                          V.F.EP-28 lubricating oil, raw                                                      V.F.EP-29 water, treated water,                                                      V.F.EP-30 treated borated                                                            V.F.EP-65 water, air with                                                            V.F.EP-66 borated water                                                              V.F.EP-67 leakage,                                                                  V.F.EP-68 condensation, gas, closed-cycle cooling water D          061 062    BWR/PWR    Nickel-alloy piping,  None            None            No                V.F.EP-115 piping components
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                        Aging Management                        Generic Aging Modified,                                                                          Program                          Lessons Learned Deleted,                                                                          (AMP)/Time-                          for Subsequent Edited                                                    Aging Effect/        Limited Aging  Further Evaluation    License Renewal Item        ID      Type          Component            Mechanism            Analyses (TLAA)  Recommended                Item exposed to air with borated water leakage 063      BWR/PWR    SS piping, piping      None                  None                No                V.F.EP-19 components                                                                          V.F.EP-22 exposed to air with borated water leakage, gas 064      BWR/PWR    Steel piping, piping  None                  None                No                V.F.EP-4 components                                                                          V.F.EP-7 3.2-35 exposed to air -
indoor controlled, gas 065      BWR/PWR    Metallic piping,      Wall thinning due to  AMP XI.M17, Flow  No                V.D1.E-407 piping components      erosion                Accelerated                            V.D2.E-408 exposed to treated                            Corrosion water, treated borated water 066      BWR/PWR    Metallic piping,    Loss of material due AMP XI.M38,          Yes (SRP-SLR        V.A.E-400 piping components,  to recurring internal Inspection of      Section 3.2.2.2.7)  V.B.E-400 tanks exposed to    corrosion            Internal Surfaces in                      V.C.E-400 raw water, waste                          Miscellaneous                            V.D1.E-400 water                                      Piping and Ducting                        V.D2.E-400 Components 067      BWR/PWR    SS tanks (within the Cracking due to      AMP XI.M29,          No                  V.D1.E-405 scope of AMP        SCC                  Outdoor and Large                        V.D2.E-405 XI.M29, Outdoor                          Atmospheric Metallic and Large                                  Storage Tanks
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                            Aging Management                        Generic Aging Modified,                                                                              Program                          Lessons Learned Deleted,                                                                            (AMP)/Time-                        for Subsequent Edited                                                    Aging Effect/            Limited Aging  Further Evaluation  License Renewal Item        ID      Type          Component            Mechanism              Analyses (TLAA)  Recommended                Item Atmospheric Metallic Storage Tanks) exposed to soil, concrete 068      BWR/PWR    Steel tanks (within    Loss of material due      AMP XI.M29,          No              V.D1.E-402 the scope of AMP      to general, pitting,      Outdoor and Large                    V.D2.E-402 XI.M29, Outdoor      crevice corrosion,        Atmospheric Metallic and Large              MIC (soil only)          Storage Tanks Atmospheric Metallic Storage Tanks) 3.2-36 exposed to soil, concrete, air, condensation 069      BWR/PWR    Insulated steel        Loss of material due AMP XI.M36,          No                    V.E.E-403a piping, piping        to general, pitting, External Surfaces                        V.E.E-403b components, tanks      crevice corrosion    Monitoring of (within the scope of                        Mechanical AMP XI.M29,                                Components or Outdoor and Large                          AMP XI.M29, Atmospheric Metallic                        Outdoor and Large Storage Tanks)                            Atmospheric Metallic exposed to air,                            Storage Tanks condensation 070      BWR/PWR    Steel, SS, aluminum    Loss of material due      AMP XI.M29,          No              V.A.E-404 tanks (within the      to general (steel        Outdoor and Large                    V.D1.E-404 scope of AMP          only), pitting, crevice  Atmospheric Metallic                  V.D2.E-404 XI.M29, Outdoor      corrosion, MIC            Storage Tanks and Large
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                            Aging Management                        Generic Aging Modified,                                                                              Program                          Lessons Learned Deleted,                                                                            (AMP)/Time-                        for Subsequent Edited                                                    Aging Effect/          Limited Aging  Further Evaluation  License Renewal Item        ID      Type          Component            Mechanism              Analyses (TLAA)  Recommended                Item Atmospheric Metallic  (steel, stainless Storage Tanks)        steel only) exposed to treated water, treated borated water 071      BWR/PWR    Insulated copper      Cracking due to          AMP XI.M36,          No              V.E.E-406 alloy (>15% zinc or    SCC                      External Surfaces
                                          >8% aluminum)                                    Monitoring of piping, piping                                  Mechanical components, tanks                                Components 3.2-37 exposed to air, condensation M          072      BWR/PWR    Any material piping,  Loss of coating or        AMP XI.M42,          No              V.A.E-401 piping components,    lining integrity due to  Internal                            V.B.E-401 heat exchangers,      blistering, cracking,    Coatings/Linings for                  V.C.E-401 tanks with internal    flaking, peeling,        In-Scope Piping,                      V.D1.E-401 coatings/linings      delamination,            Piping Components,                    V.D2.E-401 exposed to closed-    rusting, or physical      Heat Exchangers, cycle cooling water,  damage; loss of          and Tanks raw water, treated    material or cracking water, treated        for cementitious borated water,        coatings/linings lubricating oil, condensation 073      BWR/PWR    Any material piping,  Loss of material due      AMP XI.M42,          No              V.A.E-414 piping components,    to general, pitting,      Internal                            V.B.E-414 heat exchangers,      crevice corrosion,        Coatings/Linings for                  V.C.E-414 tanks with internal    MIC                      In-Scope Piping,
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                        Aging Management                        Generic Aging Modified,                                                                          Program                          Lessons Learned Deleted,                                                                          (AMP)/Time-                        for Subsequent Edited                                                    Aging Effect/        Limited Aging  Further Evaluation License Renewal Item        ID      Type          Component            Mechanism          Analyses (TLAA)    Recommended              Item coatings/linings                            Piping Components,                    V.D1.E-414 exposed to closed-                          Heat Exchangers,                      V.D2.E-414 cycle cooling water,                        and Tanks raw water, treated water, treated borated water, lubricating oil, condensation 074      BWR/PWR    Gray cast iron,        Loss of material due AMP XI.M42,          No              V.A.E-415 ductile iron,          to selective leaching Internal                            V.B.E-415 3.2-38 malleable iron                              Coatings/Linings for                V.C.E-415 piping, piping                              In-Scope Piping,                    V.D1.E-415 components with                              Piping Components,                  V.D2.E-415 internal                                    Heat Exchangers, coatings/linings                            and Tanks exposed to closed-cycle cooling water, raw water, treated water, treated borated water, waste water D          075 076      BWR/PWR    SS, steel, nickel-    Loss of material due AMP XI.M18,          No              V.E.E-418 alloy, copper alloy    to general, pitting, Bolting Integrity closure bolting        crevice corrosion, exposed to treated    MIC (steel, copper water, treated        alloy in raw water, borated water, raw    waste water only)
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                          Aging Management                            Generic Aging Modified,                                                                            Program                              Lessons Learned Deleted,                                                                          (AMP)/Time-                            for Subsequent Edited                                                    Aging Effect/        Limited Aging  Further Evaluation      License Renewal Item        ID      Type          Component            Mechanism            Analyses (TLAA)  Recommended                    Item water, waste water, lubricating oil D          077 078      BWR/PWR    SS, steel, aluminum    Cracking due to        AMP XI.M41,        No                    V.E.E-420 piping, piping          SCC (steel in          Buried and components, tanks      carbonate/bicarbona    Underground Piping exposed to soil,        te environment only)  and Tanks concrete 079      BWR/PWR    SS closure bolting      Cracking due to        AMP XI.M18,          No                  V.E.E-421 exposed to air, soil,  SCC                    Bolting Integrity 3.2-39                                    concrete, underground E          080      BWR/PWR    SS underground          Cracking due to        AMP XI.M32,          Yes (SRP-SLR        V.E.E-423a piping, piping          SCC                    One Time            Section 3.2.2.2.4)  V.E.E-423b components, tanks                              Inspection, AMP                          V.E.E-423c XI.M41, Buried and Underground Piping and Tanks, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 081      BWR/PWR    SS, steel, aluminum, Reduction of heat        AMP XI.M36,          No                  V.E.E-424 copper alloy,        transfer due to          External Surfaces titanium heat        fouling                  Monitoring of exchanger tubes
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                          Aging Management                              Generic Aging Modified,                                                                            Program                                Lessons Learned Deleted,                                                                            (AMP)/Time-                              for Subsequent Edited                                                  Aging Effect/            Limited Aging  Further Evaluation        License Renewal Item        ID      Type        Component            Mechanism              Analyses (TLAA)  Recommended                      Item exposed to air,                                Mechanical condensation                                    Components D          083 D          084 D          085 D          086 087      BWR/PWR    Nonmetallic thermal Reduced thermal        AMP XI.M36,                No                  V.E.E-422 insulation exposed  insulation resistance External Surfaces to air, condensation due to moisture      Monitoring of 3.2-40 intrusion            Mechanical Components D          089 090      BWR/PWR    Steel components      Long-term loss of        AMP XI.M32,            No                  V.A.E-434 exposed to treated    material due to          One Time                                  V.B.E-434 water, treated        general corrosion        Inspection                                V.C.E-434 borated water, raw                                                                          V.D1.E-434 water                                                                                      V.D2.E-434 091      BWR/PWR    SS piping, piping    None                      None                  Yes (SRP-SLR        V.F.EP-20 components                                                            Section 3.2.2.2.9) exposed to concrete D          092 D          095 096      BWR/PWR    Steel, SS piping,    Loss of material due      AMP XI.M38,            No                  V.D1.E-439 piping components    to general (steel        Inspection of                              V.D2.E-440 exposed to raw        only), pitting, crevice  Internal Surfaces in water (for            corrosion, MIC; flow      Miscellaneous components not
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                        Aging Management                            Generic Aging Modified,                                                                          Program                            Lessons Learned Deleted,                                                                          (AMP)/Time-                            for Subsequent Edited                                                Aging Effect/            Limited Aging  Further Evaluation    License Renewal Item        ID      Type          Component          Mechanism              Analyses (TLAA)    Recommended                  Item covered by NRC GL blockage due to            Piping and Ducting 89-13)            fouling                    Components D          097 098      BWR/PWR    Copper alloy (>15%      Loss of material due AMP XI.M33,          No                  V.D1.E-441 zinc or >8%            to selective leaching Selective Leaching                    V.D2.E-441 aluminium) piping, piping components exposed to soil 099      BWR/PWR    SS, nickel-alloy        Loss of material due AMP XI.M32,          Yes (SRP-SLR        V.E.E-442a tanks exposed to air,  to pitting, crevice  One Time            Section 3.2.2.2.2)  V.E.E-442b 3.2-41                                    condensation            corrosion            Inspection, AMP                          V.E.E-442c XI.M36, External                        V.E.E-442d Surfaces Monitoring of Mechanical Components, AMP XI.M38, Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                    Aging Management                            Generic Aging Modified,                                                                        Program                            Lessons Learned Deleted,                                                                      (AMP)/Time-                            for Subsequent Edited                                                  Aging Effect/      Limited Aging      Further Evaluation License Renewal Item      ID      Type          Component            Mechanism        Analyses (TLAA)        Recommended              Item 100    BWR/PWR    Aluminum piping,      Cracking due to    AMP XI.M32,            Yes (SRP-SLR      V.A.E-443b piping components, SCC                    One Time              Section 3.2.2.2.8) V.A.E-443c tanks exposed to air,                    Inspection, AMP                          V.A.E-443d condensation                              XI.M38, Inspection                      V.B.E-443b (internal), raw water,                    of Internal Surfaces                      V.B.E-443c waste water                              in Miscellaneous                          V.B.E-443d Piping and Ducting                        V.D1.E-443b Components, or                          V.D1.E-443c AMP XI.M42,                              V.D1.E-443d Internal                                V.D2.E-443b 3.2-42 Coatings/Linings for                      V.D2.E-443c In-Scope Piping,                          V.D2.E-443d Piping Components, Heat Exchangers, and Tanks 101    BWR/PWR    Aluminum piping,      Cracking due to    AMP XI.M32,            Yes (SRP-SLR        V.E.E-444b piping components, SCC                    One Time              Section 3.2.2.2.8)  V.E.E-444c tanks exposed to air,                    Inspection, AMP                            V.E.E-444d condensation                              XI.M36, External (external)                                Surfaces Monitoring of Mechanical Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                            Generic Aging Modified,                                                                        Program                              Lessons Learned Deleted,                                                                        (AMP)/Time-                            for Subsequent Edited                                                    Aging Effect/      Limited Aging      Further Evaluation License Renewal Item      ID      Type          Component              Mechanism        Analyses (TLAA)        Recommended              Item 102    BWR/PWR    Aluminum tanks        Cracking due to      AMP XI.M29,            Yes (SRP-SLR      V.D1.E-445a (within the scope of  SCC                  Outdoor and Large    Section 3.2.2.2.8) V.D1.E-445b AMP XI.M29,                                Atmospheric Metallic                      V.D1.E-445c Outdoor and Large                          Storage Tanks,                          V.D2.E-445a Atmospheric Metallic                        AMP XI.M32, One-                        V.D2.E-445b Storage Tanks)                            Time Inspection, or                      V.D2.E-445c exposed to air,                            AMP XI.M42, condensation, soil,                        Internal concrete, raw water,                        Coatings/Linings for waste water                                In-Scope Piping, 3.2-43 Piping Components, Heat Exchangers, and Tanks 103    BWR/PWR    SS tanks (within the  Cracking due to      AMP XI.M29,              Yes (SRP-SLR        V.D1.E-446a scope of AMP          SCC                  Outdoor and Large      Section 3.2.2.2.4)  V.D1.E-446b XI.M29, Outdoor                            Atmospheric Metallic                        V.D1.E-446c and Large                                  Storage Tanks,                              V.D2.E-446a Atmospheric Metallic                        AMP XI.M32, One                            V.D2.E-446b Storage Tanks)                            Time Inspection, or                        V.D2.E-446c exposed to air,                            AMP XI.M42, condensation                                Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 104    BWR/PWR    Aluminum tanks        Loss of material due AMP XI.M29,            No                    V.D1.E-447 (within the scope of  to pitting, crevice  Outdoor and Large                          V.D2.E-447 AMP XI.M29,            corrosion
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                            Generic Aging Modified,                                                                          Program                              Lessons Learned Deleted,                                                                        (AMP)/Time-                            for Subsequent Edited                                                  Aging Effect/        Limited Aging    Further Evaluation    License Renewal Item        ID      Type          Component            Mechanism          Analyses (TLAA)      Recommended                Item Outdoor and Large                          Atmospheric Metallic Atmospheric Metallic                        Storage Tanks Storage Tanks) exposed to soil, concrete 105      BWR/PWR    Aluminum tanks      Loss of material due AMP XI.M29,            Yes (SRP-SLR          V.D1.E-448a (within the scope of to pitting, crevice  Outdoor and Large    Section 3.2.2.2.10)  V.D1.E-448b AMP XI.M29,          corrosion            Atmospheric Metallic                        V.D1.E-448c Outdoor and Large                        Storage Tanks,                              V.D2.E-448a Atmospheric Metallic                      AMP XI.M32, One                            V.D2.E-448b 3.2-44 Storage Tanks)                          Time Inspection, or                        V.D2.E-448c exposed to air,                          AMP XI.M42, condensation                              Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks N          106      BWR/PWR    SS, nickel alloy    Loss of material due AMP XI.M29,            Yes (SRP-SLR          V.D1.E-449a tanks (within the    to pitting, crevice  Outdoor and Large    Section 3.2.2.2.2)    V.D1.E-449b scope of AMP        corrosion            Atmospheric Metallic                        V.D1.E-449c XI.M29, Outdoor                          Storage Tanks,                              V.D2.E-449a and Large                                AMP XI.M32, One                            V.D2.E-449b Atmospheric Metallic                      Time Inspection, or                        V.D2.E-449c Storage Tanks)                          AMP XI.M42, exposed to air,                          Internal condensation                              Coatings/Linings for In-Scope Piping, Piping Components,
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                              Generic Aging Modified,                                                                        Program                              Lessons Learned Deleted,                                                                        (AMP)/Time-                              for Subsequent Edited                                                    Aging Effect/      Limited Aging      Further Evaluation  License Renewal Item        ID      Type          Component            Mechanism        Analyses (TLAA)      Recommended                Item Heat Exchangers, and Tanks 107      BWR/PWR    Insulated SS, nickel- Loss of material due AMP XI.M29,            Yes (SRP-SLR        V.E.E-450a alloy piping, piping  to pitting, crevice  Outdoor and Large    Section 3.2.2.2.2)  V.E.E-450b components, tanks corrosion                Atmospheric Metallic                        V.E.E-450c exposed to air,                            Storage Tanks,                            V.E.E-450d condensation                              AMP XI.M32, One Time Inspection, AMP XI.M36, External 3.2-45 Surfaces Monitoring of Mechanical Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 108      BWR/PWR    Insulated SS piping, Cracking due to      AMP XI.M29,            Yes (SRP-SLR        V.E.E-451a piping components, SCC                    Outdoor and Large    Section 3.2.2.2.4)  V.E.E-451b tanks exposed to air,                      Atmospheric Metallic                        V.E.E-451c condensation                              Storage Tanks,                            V.E.E-451d AMP XI.M32, One-Time Inspection, AMP XI.M36, External Surfaces Monitoring
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                  Aging Management                            Generic Aging Modified,                                                                      Program                            Lessons Learned Deleted,                                                                    (AMP)/Time-                            for Subsequent Edited                                                  Aging Effect/      Limited Aging    Further Evaluation  License Renewal Item        ID      Type        Component            Mechanism        Analyses (TLAA)      Recommended              Item of Mechanical Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 109      BWR/PWR    Insulated aluminum  Cracking due to    AMP XI.M29,          Yes (SRP-SLR        V.E.E-452a 3.2-46 piping, piping      SCC                Outdoor and Large Section 3.2.2.2.8)    V.E.E-452b components, tanks                      Atmospheric Metallic                      V.E.E-452c exposed to air,                        Storage Tanks,                          V.E.E-452d condensation                            AMP XI.M32, One Time Inspection, AMP XI.M36, External Surfaces Monitoring of Mechanical Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                  Aging Management                            Generic Aging Modified,                                                                      Program                              Lessons Learned Deleted,                                                                    (AMP)/Time-                            for Subsequent Edited                                                Aging Effect/      Limited Aging      Further Evaluation License Renewal Item      ID      Type          Component            Mechanism        Analyses (TLAA)        Recommended              Item 110    BWR/PWR    Aluminum            Cracking due to      AMP XI.M32, One      Yes (SRP-SLR      V.E.E-453a underground piping, SCC                  Time Inspection,      Section 3.2.2.2.8) V.E.E-453b piping components,                      AMP XI.M41,                              V.E.E-453c tanks                                    Buried and Underground Piping and Tanks, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, 3.2-47 Heat Exchangers, and Tanks 111    BWR/PWR    Aluminum            Loss of material due AMP XI.M32,            Yes (SRP-SLR          V.E.E-454a underground piping, to pitting, crevice  One-Time              Section 3.2.2.2.10)  V.E.E-454b piping components, corrosion            Inspection, AMP                            V.E.E-454c tanks                                    XI.M41, Buried and Underground Piping and Tanks, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 112    BWR/PWR    Stainless steel,    Loss of material due AMP XI.M32, One      Yes (SRP-SLR          V.E.E-455a nickel-alloy        to pitting, crevice  Time Inspection,      Section 3.2.2.2.2)    V.E.E-455b underground piping, corrosion            AMP XI.M41,                                  V.E.E-455c piping components,                      Buried and tanks                                    Underground Piping
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                        Aging Management                            Generic Aging Modified,                                                                          Program                              Lessons Learned Deleted,                                                                          (AMP)/Time-                            for Subsequent Edited                                                  Aging Effect/          Limited Aging    Further Evaluation    License Renewal Item        ID      Type          Component            Mechanism            Analyses (TLAA)    Recommended                Item and Tanks, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks D          113 114      BWR/PWR    SS, nickel-alloy      Cracking due to        AMP XI.M2, Water  No                    V.B.E-457 piping, piping        SCC                    Chemistry, and                          V.C.E-457 3.2-48 components                                  AMP XI.M32,                              V.D2.E-457 exposed to treated                          One-Time water >60 &deg;C                                Inspection
(>140 &deg;F) 115      BWR/PWR    Titanium heat        Cracking due to        AMP XI.M2, Water  No                    V.A.E-458 exchanger tubes      SCC, reduction of      Chemistry, and                          V.D1.E-458 exposed to treated    heat transfer due to  AMP XI.M32,                              V.D2.E-458 water                fouling                One-Time Inspection E          116      BWR/PWR    Titanium ([ASTM]     None                  None                No                    V.F.E-459 Grades 1, 2, 7, 9, 11, or 12) heat exchanger components other than tubes, piping, piping components exposed to treated water
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                      Generic Aging Modified,                                                                          Program                        Lessons Learned Deleted,                                                                        (AMP)/Time-                      for Subsequent Edited                                                  Aging Effect/        Limited Aging Further Evaluation License Renewal Item      ID      Type          Component              Mechanism          Analyses (TLAA)  Recommended              Item 117    BWR/PWR    Titanium heat        Cracking due to        AMP XI.M21A,    No                V.A.E-460 exchanger tubes      SCC, reduction of      Closed Treated                    V.D1.E-460 exposed to closed-    heat transfer due to  Water Systems                      V.D2.E-460 cycle cooling water  fouling 118    BWR/PWR    Titanium (ASTM        None                  None              No                  V.F.E-461 Grades 1, 2, 7, 9, 11, or 12) heat exchanger components other than tubes, piping, 3.2-49 piping components exposed to closed-cycle cooling water E          119    BWR/PWR    Insulated aluminum    Loss of material due AMP XI.M29,          Yes (SRP-SLR        V.E.E-462a piping, piping        to pitting, crevice  Outdoor and Large Section 3.2.2.2.10)  V.E.E-462b components, tanks    corrosion            Atmospheric Metallic                    V.E.E-462c exposed to air,                            Storage Tanks,                          V.E.E-462d condensation                              AMP XI.M32, One-Time Inspection, AMP XI.M36, External Surfaces Monitoring of Mechanical Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components,
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                    Aging Management                              Generic Aging Modified,                                                                        Program                                Lessons Learned Deleted,                                                                      (AMP)/Time-                              for Subsequent Edited                                                  Aging Effect/        Limited Aging      Further Evaluation    License Renewal Item        ID      Type          Component          Mechanism          Analyses (TLAA)      Recommended                Item Heat Exchangers, and Tanks 120      BWR/PWR    Aluminum piping,    Loss of material due AMP XI.M41,            No                    V.E.E-463 piping components, to pitting, crevice    Buried and tanks exposed to    corrosion            Underground Piping soil, concrete                            and Tanks 121      BWR/PWR    Aluminum piping,    Loss of material due AMP XI.M29,            Yes (SRP-SLR          V.E.E-464a piping components, to pitting, crevice    Outdoor and Large    Section 3.2.2.2.10)  V.E.E-464b tanks exposed to    corrosion            Atmospheric Metallic                        V.E.E-464c raw water, waste                          Storage Tanks,                              V.E.E-464d 3.2-50 water                                    AMP XI.M32, One-Time Inspection, AMP XI.M38, Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components, or AMP XI.M42, Internal Coatings/Linings for In-Scope Piping, Piping Components, Heat Exchangers, and Tanks 122      BWR/PWR    Elastomer piping,    Loss of material due AMP XI.M36,            No                    V.E.E-465 piping components, to wear                External Surfaces seals exposed to air                      Monitoring of
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                      Aging Management                            Generic Aging Modified,                                                                          Program                              Lessons Learned Deleted,                                                                        (AMP)/Time-                            for Subsequent Edited                                                    Aging Effect/        Limited Aging    Further Evaluation    License Renewal Item        ID      Type          Component            Mechanism          Analyses (TLAA)      Recommended                Item Mechanical Components 123      BWR/PWR    Elastomer piping,    Loss of material due AMP XI.M38,          No                  V.A.E-466 piping components, to wear                  Inspection of                            V.B.E-466 seals exposed to air                        Internal Surfaces in                      V.C.E-466 Miscellaneous                            V.D1.E-466 Piping and Ducting                        V.D2.E-466 Components 124      BWR/PWR    Aluminum piping,      None                  None                No                  V.F.E-467 piping components, 3.2-51 tanks exposed to air with borated water leakage 125      BWR/PWR    Steel closure bolting Loss of material due AMP XI.M41,          No                  V.E.E-468 exposed to soil,      to general, pitting,  Buried and concrete,            crevice corrosion,    Underground Piping underground          MIC (soil only)      and Tanks 126      BWR/PWR    Titanium, super      Loss of material due AMP XI.M41,          No                  V.E.E-469 austenitic piping,    to pitting, crevice  Buried and piping components, corrosion, MIC          Underground Piping tanks, closure        (except for titanium; and Tanks bolting exposed to    soil environment soil, concrete,      only) underground 127      BWR/PWR    Copper alloy piping, None                  None                No                  V.F.E-470 piping components exposed to concrete
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                    Aging Management                            Generic Aging Modified,                                                                        Program                              Lessons Learned Deleted,                                                                      (AMP)/Time-                            for Subsequent Edited                                                  Aging Effect/      Limited Aging      Further Evaluation License Renewal Item      ID      Type          Component            Mechanism        Analyses (TLAA)        Recommended              Item 128    BWR/PWR    Copper alloy piping, Loss of material due AMP XI.M41,            No                V.E.E-471 piping components to general, pitting,    Buried and exposed to soil,      crevice corrosion,  Underground Piping underground          MIC (soil only)      and Tanks 129    BWR/PWR    Stainless steel tanks Loss of material due AMP XI.M29,            No                V.D1.E-472 exposed to soil,      to pitting, crevice  Outdoor and Large                      V.D2.E-472 concrete              corrosion, MIC (soil Atmospheric Metallic only)                Storage Tanks 130    BWR/PWR    Steel heat            Loss of material due AMP XI.M39,            No                V.A.E-473 exchanger            to general, pitting, Lubricating Oil                        V.D1.E-473 3.2-52 components            crevice corrosion,  Analysis, and AMP                      V.D2.E-473 exposed to            MIC                  XI.M32, One Time lubricating oil                            Inspection 131    BWR/PWR    Aluminum piping,      Flow blockage due AMP XI.M38,              No                V.A.E-474 piping components to fouling              Inspection of                          V.B.E-474 exposed to raw                            Internal Surfaces in                    V.D1.E-474 water                                      Miscellaneous                            V.D2.E-474 Piping and Ducting Components M          132    BWR/PWR    Titanium (ASTM        Cracking due to      AMP XI.M20, Open      No                V.A.E-475 Grades 3, 4, or 5)    SCC, flow blockage Cycle Cooling Water                        V.D1.E-475 heat exchanger        due to fouling      System                                  V.D2.E-475 tubes exposed to raw water
 
Table 3.2-1      Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                        Aging Management                          Generic Aging Modified,                                                                          Program                            Lessons Learned Deleted,                                                                          (AMP)/Time-                          for Subsequent Edited                                                  Aging Effect/          Limited Aging    Further Evaluation License Renewal Item      ID      Type          Component            Mechanism            Analyses (TLAA)    Recommended              Item 133    BWR/PWR    Titanium piping,      Cracking due to          AMP XI.M20, Open No                  V.B.E-476 piping components,    SCC, flow blockage      Cycle Cooling Water                    V.C.E-476 heat exchanger        due to fouling          System                                V.D2.E-476 components exposed to raw water M          134    BWR/PWR    Polymeric piping,    Hardening or loss of    AMP XI.M36,            No            V.A.E-477b piping components,    strength due to          External Surfaces                    V.B.E-477b ducting, ducting      polymeric                Monitoring of                        V.D1.E-477b components, seals    degradation; loss of    Mechanical                            V.D2.E-477b 3.2-53 exposed to air,      material due to          Components, AMP                      V.E.E-477a condensation, raw    peeling,                XI.M38, Inspection water, raw water      delamination, wear;      of Internal Surfaces (potable), treated    cracking or blistering  in Miscellaneous water, waste water,  due to exposure to      Piping and Ducting underground,          ultraviolet light,      Components concrete, soil        ozone, radiation, or chemical attack; flow blockage due to fouling (Inspection of Internal Surfaces only)
 
Table 3.2-1        Summary of Aging Management Programs for Engineered Safety Features Evaluated in Chapter V of the Generic Aging Lessons Learned for Subsequent License Renewal Report (Continued)
New,                                                                            Aging Management                                      Generic Aging Modified,                                                                                Program                                        Lessons Learned Deleted,                                                                              (AMP)/Time-                                      for Subsequent Edited                                                          Aging Effect/        Limited Aging  Further Evaluation                License Renewal Item        ID        Type              Component            Mechanism        Analyses (TLAA)    Recommended                            Item N            135      BWR/PWR        Steel, stainless steel Loss of material due Plant-specific or  Yes (SRP-SLR                    V.A.E-457 or nickel-alloy ASME to wear                existing aging    Section 3.2.2.2.11)              V.B.E-457 Code Class 2 small-                        management                                          V.C.E-457 bore piping, and                            program if loss of                                  V.D1.E-457 piping components                          material is not                                    V.D2.E-457 with reflective metal                      mitigated                                          V.E.E-457 insulation exposed to air 1  AMP = aging management program; BWR = boiling water reactor; CASS = cast austenitic stainless steel; HPSI = high-pressure safety injection; IGSCC =
2  intergranular stress corrosion cracking; MIC = microbiologically-induced corrosion; PWR = pressurized water reactor; SCC = stress corrosion cracking; SRP-SLR =
3.2-54 3  Standard Review Plan for Review of Subsequent License Renewal; SS = stainless steel; TLAA = Time-Limited Aging Analyses.}}

Latest revision as of 02:08, 29 September 2023