B12439, Informs That Reactor Trip Sys Included in Westinghouse/Util Vendor Interface Program,Per NRC 870224 Request & Generic Ltr 86-38,Item 2.1.2: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[A06384, Informs That Reactor Trip Sys Included in Westinghouse/Util Vendor Interface Program,Per NRC 870224 Request & Generic Ltr 86-38,Item 2.1.2]]
| number = ML20207Q907
| issue date = 03/05/1987
| title = Informs That Reactor Trip Sys Included in Westinghouse/Util Vendor Interface Program,Per NRC 870224 Request & Generic Ltr 86-38,Item 2.1.2
| author name = Mroczka E
| author affiliation = CONNECTICUT YANKEE ATOMIC POWER CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
| docket = 05000213
| license number =
| contact person =
| document report number = A06384, A6384, B12439, GL-83-28, NUDOCS 8703100183
| document type = CORRESPONDENCE-LETTERS, INCOMING CORRESPONDENCE, UTILITY TO NRC
| page count = 1
}}
 
=Text=
{{#Wiki_filter:CONNECTICUT YANKEE ATOMIC POWER COMPANY B E R L I N, CONNECTICUT P.o. box 270
* HARTFORD, CONNECTICUT 061414270 TELEPHONE musa                                          March 5,1987 Docket No. 50-213 A06384 B12439 Re: GL83-28, Item 2.1.2 U.S. Nuclear Regulatory Commission Attn:      Document Control Desk Washington, D.C. 20555 Gentlemen:
Haddam Neck Plant Generic Letter 83-23, Item 2.1.2 In a {{letter dated|date=February 24, 1987|text=letter dated February 24,1987}},(I) the Staff requested that the Connecticut Yankee Atomic Power Company (CYAPCO) verify that the reactor trip system at the Haddam Neck Plant is included in the Westinghouse vendor interface program.
CYAPCO has confirmed with Westinghouse that the Haddam Neck Plant reactor trip system is included in the Westinghouse /CYAPCO interface program.
We conclude that this should satisfactorily resolve the Staff's concerns on Generic Letter 83-28, Item 2.1.2.
Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY A)
E. 3. A (oc'zk'a  .f Senior)Vice President cc:      P. D. Swetland, Resident Inspector, Haddam Neck Plant F. M. Akstulewicz, NRC Project Manager, Haddam Neck Plant Dr. T. E. Murley, Region 1 Administrator (1)      F. M. Akstulewicz letter to E. 3. Mroczka, " Request for Additional Information Concerning Responses to Generic Implications of Salem ATWS Events (Generic Letter 83-23)," dated February 24,1987.
b B703100183 870305 PDR  ADOCK 05000213                                                                      ) D P                  PDR l
L}}
 
=Text=
{{#Wiki_filter:CONNECTICUT YANKEE ATOMIC POWER COMPANY B E R L I N, CONNECTICUT P.o. box 270
* HARTFORD, CONNECTICUT 061414270 TELEPHONE musa                                          March 5,1987 Docket No. 50-213 A06384 B12439 Re: GL83-28, Item 2.1.2 U.S. Nuclear Regulatory Commission Attn:      Document Control Desk Washington, D.C. 20555 Gentlemen:
Haddam Neck Plant Generic Letter 83-23, Item 2.1.2 In a {{letter dated|date=February 24, 1987|text=letter dated February 24,1987}},(I) the Staff requested that the Connecticut Yankee Atomic Power Company (CYAPCO) verify that the reactor trip system at the Haddam Neck Plant is included in the Westinghouse vendor interface program.
CYAPCO has confirmed with Westinghouse that the Haddam Neck Plant reactor trip system is included in the Westinghouse /CYAPCO interface program.
We conclude that this should satisfactorily resolve the Staff's concerns on Generic Letter 83-28, Item 2.1.2.
Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY A)
E. 3. A (oc'zk'a  .f Senior)Vice President cc:      P. D. Swetland, Resident Inspector, Haddam Neck Plant F. M. Akstulewicz, NRC Project Manager, Haddam Neck Plant Dr. T. E. Murley, Region 1 Administrator (1)      F. M. Akstulewicz letter to E. 3. Mroczka, " Request for Additional Information Concerning Responses to Generic Implications of Salem ATWS Events (Generic Letter 83-23)," dated February 24,1987.
b B703100183 870305 PDR  ADOCK 05000213                                                                      ) D P                  PDR l