#REDIRECT [[HBL-87-047, Forwards Rev 3 to Custodial Safstor Facility QA Plan.Changes Include Clarification of Sections Re Packaging & Transportation,Fire Rating of Storage Containers,Audit Frequency & Ref to Reg Guide]]
| number = ML20236G797
| issue date = 07/30/1987
| title = Forwards Rev 3 to Custodial Safstor Facility QA Plan.Changes Include Clarification of Sections Re Packaging & Transportation,Fire Rating of Storage Containers,Audit Frequency & Ref to Reg Guide
| author name = Shiffer J
| author affiliation = PACIFIC GAS & ELECTRIC CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
| docket = 05000133
| license number =
| contact person =
| document report number = HBL-87-047, HBL-87-47, NUDOCS 8708040393
| package number = ML20236G799
| document type = CORRESPONDENCE-LETTERS, INCOMING CORRESPONDENCE, UTILITY TO NRC
| page count = 2
}}
 
=Text=
{{#Wiki_filter:_
l I
    . , * ~
          . PACIFIC OAS' AND . ELECTR,IC                                                            C O M PANY EO!!45                l  . 77 BEALE STREET . SAN FRANCISCO, CALIFORNI A 94106 ' * (415)781 4211 . TWX 910 372-6587
            . JAMES D. SHIPPER NUCLEA    A GtN RATION July 30, 1987 PGandE Letter No.:          HBL-87-047 U. S. Nuclear. Regulatory Commission ATTN:      Document Control. Desk Hashington D.C. . 20555 Re: Docket No. 50-133, OL-DPR-7 Humboldt Bay Power Plant Unit 3
                        . Custodial SAFSTOR Facility Quality Assurance Plan, Revision 3 Gentlemen:
PGandE hereby' submits the Custodial SAFSTOR Facility Quality Assurance Plan, Revision 3. This revision supersedes Revision 2, which was submitted in
                  -PGandE Letter HBL-86-019, dated May 23, 1986.
The revision differs from the previous submittal in the following areas:
                  -a)    - Section 1.2.a - The packaging and transportation _ of radioactive material activity was clarified by adding "within the scope of 10 CFR 71."
b)      Section 3.1.6 - The fire rating for storage containers for SAFSTOR records was. changed to one hour, c)      Section 3.1.7 - The audit frequency specified was corrected to agree with that currently applicable to Humboldt Bay Power Plant Unit 3 (i.e., "at least once every 24 months.")
d)      Section 3.1.7 - Reference to the Regulatory Guide was corrected in two places.
e)      Section 3.3 - The intent of this section was clarified by adding "within the scope of 10 CFR 71."
Changes are indicated with vertical lines in the right-hand margin.
o
                        @"M !I4y;p                                                                                          fp0
                                                                                                                                          /f(
 
        ' Doc'ument C:ntrol Desk-PGandE' Letter'No. HBL-87-047
            . July 30, 1987
            -Page 2.
Kindly acknowledge receipt of this material on the enclosed copy of this letter and return it in the enclosed addressed envelope.
Sincerely,_,
M Enclosure                                      i cc w/ enc.:    H. N..Berkow P. B. Erickson J. B.'Hartin R. T. Nelson Humboldt Service List cc w/o enc.: Humboldt Distribution 1547S/0051K/PLP/1739
_ _ _ - _ _ _ _ _ _ _ - _ _ - _ _ _ _ _ _ _ _ .}}