05000325/LER-1982-064: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{Adams
#REDIRECT [[05000325/LER-1982-064, Forwards LER 82-064/03L-0]]
| number = ML20055B720
| issue date = 07/13/1982
| title = LER 82-064/03L-0:on 820615,post-accident Monitoring Control Room Recorder/Indicator 1-CAC-AR-1259 Erraticaly Indicated Drywell Oxygen Concentrations.Caused by Erratic Instrument Output Due to Unknown Causes.Unit Replaced
| author name = Pastva M
| author affiliation = CAROLINA POWER & LIGHT CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| docket = 05000325
| license number =
| contact person =
| document report number = LER-82-064-03L-01, LER-82-64-3L-1, NUDOCS 8207230183
| package number = ML20055B716
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 1
}}
{{LER
| Title = 
| Plant =
| Reporting criterion =
| Power level =
| Mode =
| Docket = 05000325
| LER year = 2082
| LER number = 64
| LER revision =
| Event date =
| Report date =
| ENS =
| abstract =
}}
 
=text=
{{#Wiki_filter:NRC FORM 366                                                                                                            tJ. S. NUCLE AR REGULATORY COMMISSION (7-7H y ' 'c                                                            LICENSEE EVENT REPORT CONTROL BLOCm [ l                  l      l    l  l    l                  (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1                                6 jo lil lU IC lB lE lP l 1 l@l0 l0 l- l0LICENSE14    15 l0 l0NUMBER l0 l0 l- l0 l0 l@l4 l1 25      26 l1 l1l1l@l$7 CAT LICENSE TYPE Jo l
                                                                                                                                                                    $8 l@
7      8 9          LICENSEE CODE CON'T l0lil            3{nc      l L j@] 0 l 5 l0 l- [0 l 3 l 2 15                      68
                                                                                          @l0 69 l6 l1 15 l8 l2 h] Ol 7REPOR 74      75 l 1lT D3lATE8 l 280l@
7      14                    60          61            DOCKET NUVBER                            EVENT DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h l 0 l 2 l l During plant operation, routine surveillance revealed nost-accident monitorino conrrn1l l 0 l 31 l Room recorder / indicator, 1-CAC-AR-1259, was erratically indicatina drywell oxveen                                                                              l l o l 4 l l concentrations. At the time redundant instrument. 1-CAC-AR-1263. was indicatine                                                                                l loisl l expected drywell oxygen concentrations. This event did not affect the health and                                                                                    1 0 6      l safety of the public.                                                                                                                                    __j 10171 1                                                                                                                                                                    I l O is l l                      Technical Specifications 3. 3.5. 3, 3.6.6.4. 6.9.1.9b                                                                                      I 80 7      8 9 SYSTEM            CAUSE          CAUSE                                                      COMP.          VALVE CODE              CODE        SU8 CODE                COMPONENT CODE                    SU8 CODE          SUBCODE l0l9]
7      8 lS lE l@ Wh l Elh lIlNI S lT lR lU lh Wh d h 9        10          11            12            13                            18          19              20
_                                      SEQUEN TI AL                      OCCUR RE NCE          REPORT                        REVISION LER RO      EVENT YEAR                            REPORT NO.                            CODE                TYPE                            NO.
hR            RT
_ 21 l8l2l 22 9
23 l0l6l4l 24            26 l/l 27 l0 l3 l N        M
[L_j 30 l-l 31
[0_]
32 AK N AC                    O PLANT            E                    HOURS          SB IT D          FOR b B.          SVP Lt                MANUFACTURER lX 33 l@ 34W @                [_Z_J@
35
[Z_j@
l0l0l0l0l 3/                  40 Wh 43 lY 42 l@          lN]@
43 l44B l 1 l 3 l 547 l@
CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l 1101 lThe event was caused by erratic instrument outnut in rhn electrnmnenotic unir nf tho                                                                                l l i l i j l monitor oxygen analyzer. 1-CAC-AT-1259-2.                                      The cause of rho orrnric nuernie enu1A nne                                      I
    , 2      [be determined. The defective electromagnetic unit was renlaced and the nnniv7er. Mndoll lil3l lNo. F3M3 was returned to service. These analyzers will be renlaced as narr of nn                                                                                      I i 4      lapproved plant modification.                                                                                                                                    I 7    8 3                                                                                                                                                                80 ST      S          % POWER                      OTHE R STATUS              IS O RY                              DISCOVERY DESCRIPTION l1 I s l y(3) l0l6l0l@l                                                  NA      l    b @l          Operator Surveillance                                                l ACTIVITY CO TENT RELEASED OF RELEASE                      AMOUNT OF ACTIVITY                                                      LOCATION OF RELEASE 1 6              h [_Z_j@l                                            NA      l          l 45 NA 80 l
7    8 9                10          11                                      44 PERSONNEL E XPOSURES NUMBER                          DE SC RIP TION -
l l t l 7 l l 0 l 0 l0 lhlTYPEZlhl                                                                      NA PERSOf 4NE L INJURIES
* NuvrsER            oESCRiPTiO9h I l 11010 7      8 9 l0 l1l@l      12 NA 80 l
LO'a OF OR DAMAGE TO FACILITY Q TYPE      DE SC RIP TION              v l
1 9 lZ]@l                                                                                    NA 8
              ' eU8ti$TY                              8207230193 820713                                                                                NRC USE ONLY IS                                      PDR ADOCK 05000325                                                                                                          ,
ITTT1 dSUE @DESCRIPTIONb 7    8 9 l
to s                              PDR                , , ,                            j 68 09
[ll,llllll ((lj
: 80. %
NAME OF PREPARER M. J. Pastva, Jr.                                              pgoye 919-457-9521
}}
 