{{Adams
#REDIRECT [[05000272/LER-1981-046, Forwards LER 81-046/03L-0.Detailed Event Analysis Encl]]
| number = ML20004E764
| issue date = 06/08/1981
| title = Forwards LER 81-046/03L-0.Detailed Event Analysis Encl
| author name = Uderitz R
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY
| addressee name = Grier B
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
| docket = 05000272
| license number =
| contact person =
| document report number = NUDOCS 8106150217
| package number = ML20004E765
| document type = CORRESPONDENCE-LETTERS, INCOMING CORRESPONDENCE, UTILITY TO NRC
| page count = 3
}}
 
=Text=
{{#Wiki_filter:.-.s (1PSEG Public Service Electric and Gas Company 80 Park Pld a Newark, N.J. 07101 Phone 201,430-7000 June 8, 1981 9 "I      '6Ds Mr. Boyce H. Grier Q'\}
                                                                                      'j' b L l f              %# \
J 'CI Director of USNRC Office of Inspection and Enforcement c.,
U      gJLNlojgglm-Il) a Region 1                                                                    My "' M "sys** g; 631 Park Avenue                                                                                          '8 King of Prussia, Iannsylvania                      19406                        "'s ' >
                                                                                          /x  /n.        g 4/ [Ty \{<p
 
==Dear Mr. Grier:==
 
LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 81-46/03L Pursuant to the requirements of Salem Generating Station Unit No. 1 Technical Specifications, Section 6.9.1, we are submitting Licensee Event Report for Reportable Occurrence 81-46/03L.                                  This report is required within thirty (30) days of the occurrence.
Sincerely yours, l
                                                                /M441 R. A. Uderitz l                                                              General Manager -
l                                                              Nuclear Production l
\
CC:      Director, Office of Inspection and Enforcement (30 copies) l Director, Office of Management 1                  Information and Program Control (3 copies)                                                                                                    .
l l
l l
l 8106150100),
                    . d3 - - --
E  l' '' 4 0
 
        . Report N2mber:      81-46/03L Report Date:        June 8, 1981 Occurrence Date:    5/12/81 Facility:            Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancocks Bridge, New Jersey  08038 IDENTIFICATION OF OCCURRENCE:
13 Containment Fan Coil Unit - Inoperable CONCITIONS PRIOR TO OCCURRENCE:
Mode 1 - Rx Power 99% - Unit Load 1100 MWe DESCRIPTION OF OCCURRENCE:
At 1120 hours on May 12, 1981, Action Statement 3.6.2.3 was entered when the attempt to shift No. 13 Containment Fan Coil Unit from low cooling water flow to high flow was deemed unsuccessful when the required cooling water flow rate was not obtained.              Specifically, the required flow rate of > 2500 gpm was not reached; the flow rate of N 900 gpm was sustained.
This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.
DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:
The designation of the apparent cause of this occurrence is equipment failure. The preliminary investigation of the problem revealed that service water valve 13SW65 did not automatically shift position to provide the higher cooling water flow required. In order to identify the specific problem, the subject valve was dismantled and inspected.
The results of this inspection identified the specific cause of the problem to be an equipment failure when the valve stem was found to be separated from the actuator due to a cracked *runnion block plug.
ANALYSIS OF OCCURRENCE:
Restore the inoperable group of cooling fans to cperable status within 7 days or be in at least hot standby within the next 6 hours and in cold shutdown within the following 30. hours IAW Technical Specification 3.6.2.3.
 
    ,  LER 61-46/03L                                                June 8,              1981 CORRECTIVE ACTION:
The trunnion block plug for 13SW65 was replaced. In addition, and as a preventive maintenance measure, the following valve parts were also replaced while the subject valve was dismantled: snap ring, rod end bearing, feedback spring assembly, disphragm, and the vane arm pin.
The subject valve was subsequently reassembled, tested, and returned to service. Action Statement 3.6.2.3 was terminated at 2335 hours on May 13, 198.'.
FA1 LURE DATA:
Valve 13SW65 Masoneilan International, Inc.
Trunnion Block Plug #021107-202-319 Snap Ring #971881-053-181 i                      Vane Arm Pin #037002-245-153 Rod End Bearing #971705-018-888 Diaphragm #0211114-020-686 Feedback Spring Sub. Assembly #021100-066-88 Prepared By              J. J.      Espey Manager -        Saled
                                                                              /              ,
Generating Station SORC Meeting No.                81-45 l