ML20009D540: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{Adams
#REDIRECT [[05000315/LER-1981-022-03, /03L-0:on 810618,during Surveillance,Feedwater Snubber 1-FWS-1 Found to Have Rotated to Position Allowing Air to Enter Fluid Inlet Ports.During Functional Bench Test, Snubber Failed to Lock Up.Caused by Loose Locknut]]
| number = ML20009D540
| issue date = 07/17/1981
| title = LER 81-022/03L-0:on 810618,during Surveillance,Feedwater Snubber 1-FWS-1 Found to Have Rotated to Position Allowing Air to Enter Fluid Inlet Ports.During Functional Bench Test, Snubber Failed to Lock Up.Caused by Loose Locknut
| author name = Piehl R
| author affiliation = INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
| docket = 05000315
| license number =
| contact person =
| document report number = LER-81-022-03L-01, LER-81-22-3L-1, NUDOCS 8107240153
| package number = ML20009D536
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 1
}}
 
=Text=
{{#Wiki_filter:-                                _.                          -                                                                                                                -
NRC FORM 366                                                                                                                                                        U.S. MUCLEAR REGULATORY COMMISSIOR.
    - (7-77 )
  ,              e                                                                                  LICENSEE EVENT REPORT
* CONTROL BLOCK: l              l        l        l        l        l        l                          (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIOhl)
              .1                                  i                                                    e
,      jolt llMlIlDlClCl 1 l@l 0 l 0 l- l 0 l 010          14 l 010 l- l010 l@l4 LICENSE NUMBER                        26            26 l1LICENSE l1 l1TYPE  l1 JOl@l57 CAT  l
                                                                                                                                                                                                                          $8 l@
7          8.9          LICENSEE CODE                          15 i      COWT klolil 4      7          8
                              $Ry l L l@l 0 l 5 l 0 l 0 ! 0 l 3 I l 15 l@l 01611 l8 l 811 l@l 750 l 7REPOR 60          El                    DOCKET NUMBER                                    68    69      EVENT DATE                        14 l 1 lT DATE 7 l 8 l 180 l@
EVENT DESCRIPT!ON AND PROBABLE CONSEQUENCES h
; IO I2l l                    DURING PERFORMANCE OF INACCESSIBLE HYDRAULIC SNUBBER SURVEILLANCE, FEEDWATER                                                                                                                        I g o l3l l            SNUBBER 1-FWS-1 WAS FOUND TO HAVE ROTATED TO A POSITION ALLOWING AIR TO ENTER                                                                                                                        l y o l4l l THE FLUID INLET PORTS. DURING FUNCTIONAL BENCH TEST, THE SNUBBER FATLED TO                                                                                                                          l
; inl3; l                    LOCKUP IN EITHER COMPRESSION OR TENSION AND WAS DECLARED AN INSPECTION FAILURE                                                                                                                      l loisl-l              PER T.S. 4. 7.8.1.1.                                HEALTH AND SAFETY OF THE PUBLIC WAS NOT AFFECTED. A SIMILAR                                                                                      l 10 l 7 l l            OCCURRENCE WAS REPORTED AS RO 78/086/03L-0 FOR DOCKET 050-0316.                                                                                                                                      l
;
l l~ 7'10181          8 9l Bo
                                                                                                    ^"
                                              'su"                          ''                                                                                                              -
!                                                                        ! ode'                Su'eCMe                              COuPONENTCODE                                Suec7DE SMME
,o                9                          l Z lZ l@ y@ lE l@ l Sl Ul Pl Ol R] Tl@ lD l@ lZ l@                                                            18                        19            to 7          8                        9        to                11                        12                      13 i                                                                                                    SEQUENTIAL                                  OCCUR R E NCE                        REPORT                    REVISION LE Rc RO _ EVENT YEAR REPORT NO.                                    CODE                                TYPE                        N O.
j                      - @ ,RE        g l218 22l 1l l-l 23 l0 l2 l2 l 24                      26 l/l 27 l0l3l N            29 U30
[---J 31
[0]
32 4
AC ON            O PL NT                      tET                                      HOURS          SB (T D                FO 1                B.      SUPP E            MAN FACTurER l33Elgl34 Hl@                  y@                          [,Zj@                      31 l 0l 0l 0] 0l                l Nl@
41 lNj@                    lAl@          l44I l 2 l 0 l 747l@
36                          36                                                  40                            42                      43
<                        CAUSE DESCRIPTION AND CORRECTIVE ACTIONS l1lo l l            WORK WAS IN PROGRESS IN THE AREA AND SNUBBER MAY HAVE BEEN BWPED OR STEPPED ON,                                                                                                                        l i i        l CAUSING THE EXTENSION ARM LOCKNUT TO LOOSEN. THE SNUBBER WAS REFILLED, BLED.                                                                                                                          I i 7          l  TESTED AND REINSTALLED WITH NUTS TIGHTENED Ato STAKED. LETTER SENT TO DEPART-                                                                                                                          l l ,13 l l            MENT HEADS REQUESTING PERSONNEL BE CAUTIONED TO USE CARE NEAR HYDRAULIC SNUBBER                                                                                                                        l 3 4        l ' INSTALLATIONS.                        INSPECTION FREQUENCY CHANGED PER T.S. TABLE 4.7-9.                                                                                                                I 80 4
7          8 9 ST    S          % POWE R                                OTHER STATUS                                  Di O RY                                          DISCOVEe4Y DESCRIPTION 32
[
NA                                                                                                                                            l i s l H l@ l 0l 0l 0l@l"          ''                                                                ''
l    lBl@lMAINTENANCEPERSONNELOBSERVATION
                                                                                                                                  *
* a A!nvlTv CaTENT RELEASED OF RELEASE                            AMOUNT OF ACTIVITY                                                                                        LOCATION OF RELEASE i e        LZJ @ Lzj@l                                          NA                                            l          l      NA                                                                                  l i                                                                                                                                                                                                                                80 7        89                  10          11                                                                    44          45 PERSONNEL EXPOSURES NUMBER            TYPE          DESCRIPTION NA                                                                                                                                                  l
;            i 7        l 0 l 0 l 0 l@l Z l@L
* nRSONJIwunS DESCR,PnON@ NA j Q.8 9l ~uyeER0l0l0l@l                  11    12                                                                                                                                                                              80 l
4
' 7 LOSS OF OR DAMAGE TO FACILITY i                      TYPE      DESCRIPTION NA                                                                                                                                                  l i o W @l'                                                                                                                                                                                                    Bo
                                      '                                                              8107240153 810717                                                                                    NRC USE ONt Y ISSUE                                                                        PDR ADOCK 05000315                                                                                                                ,
i        UQoj [tif@DESCRIPTIONh    l                                          NA                    s                                        PDR                                              g    ; g g g g g g g g g ggg 7        8 9            10                                                                                                                                                          68 69                          80 5 PHONE:
616- 65-5901, EXT.1036 NAVE OF PREPARER
        ,- .-_ - - - . -                                      - , - . , . - . - . . - , - , . . - . . . . . . . - . . - . -                            , . ~ - . - . - - - .. .. , - .}}

Latest revision as of 00:05, 23 December 2024