ENS 54456: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{ENS notification | {{ENS notification | ||
| event number = 54456 | | event number = 54456 | ||
| facility = | | facility = | ||
| Organization = Texas Dept Of State Health Services | | Organization = Texas Dept Of State Health Services | ||
| license number = L06932 | | license number = L06932 | ||
Line 10: | Line 10: | ||
| utype = | | utype = | ||
| cfr = Agreement State | | cfr = Agreement State | ||
| emergency class = Non Emergency | | emergency class = Non Emergency | ||
| notification date = 12/23/2019 14:19 | | notification date = 12/23/2019 14:19 | ||
| notification by = Karen Blanchard | | notification by = Karen Blanchard | ||
| NRC officer = Bethany Cecere | | NRC officer = Bethany Cecere</Td> | ||
| event date = 12/20/2019 00:00 CST | | event date = 12/20/2019 00:00 CST | ||
| last update date = 12/23/2019 | | last update date = 12/23/2019 | ||
| title = Agreement State Report - Three Gauge Shutters Inoperable | | title = Agreement State Report - Three Gauge Shutters Inoperable | ||
| event text = The following was received via email from the state of Texas: | | event text = | ||
On December 23, 2019, the licensee notified the Agency [Texas Department of State Health Services] that late, after hours, on December 20, 2019, it had discovered during routine gauge inspections that the shutters on three (3) of their Berthold Model LB 7440 gauges were inoperable. The shutters are in the open position which is the normal operating position for the gauges. Two of the gauges contain 100 milliCuries of cesium-137 each and the third contains 10 milliCuries of cesium-137. Due to their location, there is no increased risk of exposure to any persons. The licensee is in the process of scheduling repairs. An investigation into this event is ongoing. More information will be provided as it is obtained in accordance with SA-300. | The following was received via email from the state of Texas: | ||
TX Incident # 9729 | |||
"On December 23, 2019, the licensee notified the Agency [Texas Department of State Health Services] that late, after hours, on December 20, 2019, it had discovered during routine gauge inspections that the shutters on three (3) of their Berthold Model LB 7440 gauges were inoperable. The shutters are in the open position which is the normal operating position for the gauges. Two of the gauges contain 100 milliCuries of cesium-137 each and the third contains 10 milliCuries of cesium-137. Due to their location, there is no increased risk of exposure to any persons. The licensee is in the process of scheduling repairs. An investigation into this event is ongoing. More information will be provided as it is obtained in accordance with SA-300." | |||
TX Incident # 9729</td> | |||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200101en.html#en54456 | | URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200101en.html#en54456 | ||
}} | }} | ||
{{ENS-Nav}} | {{ENS-Nav}} |
Latest revision as of 00:28, 14 January 2021
Where | |
---|---|
Texas Dept Of State Health Services Orange, Texas (NRC Region 4) | |
License number: | L06932 |
Organization: | Texas Dept Of State Health Services |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+80.32 h3.347 days <br />0.478 weeks <br />0.11 months <br />) | |
Opened: | Karen Blanchard 14:19 Dec 23, 2019 |
NRC Officer: | Bethany Cecere |
Last Updated: | Dec 23, 2019 |
54456 - NRC Website | |