ENS 53142: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 12/30/2017 07:17 CST
| event date = 12/30/2017 07:17 CST
| last update date = 01/02/2018
| last update date = 01/02/2018
| title = Technical Specification Required Report For An Abnormal Occurrence
| title = Technical Specification Required Report for an Abnormal Occurrence
| event text = On 12/30/17 at 0717 CST, the University of Missouri-Columbia Research Reactor (MURR) was shut down due to the loss of negative pressure in the reactor containment building.  Prior to the shutdown, the reactor was operating for a period of time during the loss of negative pressure which is a deviation from MURR Technical Specifications (TS).  This email is a required notification per TS 6.6.c.(1) to report to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1, had occurred.  Specifically, MURR was not in compliance with all TS Limiting Conditions for Operations (LCOs).  MURR was not in compliance with TS's 3.4.b and 3.4.a.(6).   
| event text = On 12/30/17 at 0717 CST, the University of Missouri-Columbia Research Reactor (MURR) was shut down due to the loss of negative pressure in the reactor containment building.  Prior to the shutdown, the reactor was operating for a period of time during the loss of negative pressure which is a deviation from MURR Technical Specifications (TS).  This email is a required notification per TS 6.6.c.(1) to report to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1, had occurred.  Specifically, MURR was not in compliance with all TS Limiting Conditions for Operations (LCOs).  MURR was not in compliance with TS's 3.4.b and 3.4.a.(6).   
TS 3.4.b. states, 'Reactor containment integrity shall be maintained at all times except when:  (1) The reactor is secured...'  TS. 3.4.a.(6) states, 'For reactor containment integrity to exist, the following conditions shall be satisfied:...(6) The reactor containment building is at a negative pressure of at least 0.25 inches of water with respect to the surrounding areas: and...'
TS 3.4.b. states, 'Reactor containment integrity shall be maintained at all times except when:  (1) The reactor is secured...'  TS. 3.4.a.(6) states, 'For reactor containment integrity to exist, the following conditions shall be satisfied:...(6) The reactor containment building is at a negative pressure of at least 0.25 inches of water with respect to the surrounding areas: and...'

Latest revision as of 20:41, 1 March 2018

ENS 53142 +/-
Where
Univ Of Missouri-Columbia
Columbia, Missouri (NRC Region 0)
License number: R-103
Reporting
Non
Time - Person (Reporting Time:+71.98 h2.999 days <br />0.428 weeks <br />0.0986 months <br />)
Opened: Bruce Meffert
13:16 Jan 2, 2018
NRC Officer: Bethany Cecere
Last Updated: Jan 2, 2018
53142 - NRC Website