ENS 53142: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 12/30/2017 07:17 CST | | event date = 12/30/2017 07:17 CST | ||
| last update date = 01/02/2018 | | last update date = 01/02/2018 | ||
| title = Technical Specification Required Report | | title = Technical Specification Required Report for an Abnormal Occurrence | ||
| event text = On 12/30/17 at 0717 CST, the University of Missouri-Columbia Research Reactor (MURR) was shut down due to the loss of negative pressure in the reactor containment building. Prior to the shutdown, the reactor was operating for a period of time during the loss of negative pressure which is a deviation from MURR Technical Specifications (TS). This email is a required notification per TS 6.6.c.(1) to report to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1, had occurred. Specifically, MURR was not in compliance with all TS Limiting Conditions for Operations (LCOs). MURR was not in compliance with TS's 3.4.b and 3.4.a.(6). | | event text = On 12/30/17 at 0717 CST, the University of Missouri-Columbia Research Reactor (MURR) was shut down due to the loss of negative pressure in the reactor containment building. Prior to the shutdown, the reactor was operating for a period of time during the loss of negative pressure which is a deviation from MURR Technical Specifications (TS). This email is a required notification per TS 6.6.c.(1) to report to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1, had occurred. Specifically, MURR was not in compliance with all TS Limiting Conditions for Operations (LCOs). MURR was not in compliance with TS's 3.4.b and 3.4.a.(6). | ||
TS 3.4.b. states, 'Reactor containment integrity shall be maintained at all times except when: (1) The reactor is secured...' TS. 3.4.a.(6) states, 'For reactor containment integrity to exist, the following conditions shall be satisfied:...(6) The reactor containment building is at a negative pressure of at least 0.25 inches of water with respect to the surrounding areas: and...' | TS 3.4.b. states, 'Reactor containment integrity shall be maintained at all times except when: (1) The reactor is secured...' TS. 3.4.a.(6) states, 'For reactor containment integrity to exist, the following conditions shall be satisfied:...(6) The reactor containment building is at a negative pressure of at least 0.25 inches of water with respect to the surrounding areas: and...' |
Latest revision as of 20:41, 1 March 2018
Where | |
---|---|
Univ Of Missouri-Columbia Columbia, Missouri (NRC Region 0) | |
License number: | R-103 |
Reporting | |
Non | |
Time - Person (Reporting Time:+71.98 h2.999 days <br />0.428 weeks <br />0.0986 months <br />) | |
Opened: | Bruce Meffert 13:16 Jan 2, 2018 |
NRC Officer: | Bethany Cecere |
Last Updated: | Jan 2, 2018 |
53142 - NRC Website | |