ML19261A834: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) Created page by program invented by StriderTol |
StriderTol (talk | contribs) Created page by program invented by StriderTol |
||
| Line 6: | Line 6: | ||
| number = ML19261A838 | | number = ML19261A838 | ||
| issue date = 01/16/1979 | | issue date = 01/16/1979 | ||
| title = | | title = LER 78-039/03L-0 on 781218:test Results Found HPCI Initiation Switches Associated W/Drywell Pressure Instruments Not in Accordance W/Tech Specs.Caused by Procedural Inadequacy;Switches Excluded from Test Program | ||
| author name = Tietz G | | author name = Tietz G | ||
| author affiliation = COMMONWEALTH EDISON CO. | | author affiliation = COMMONWEALTH EDISON CO. | ||
Latest revision as of 12:25, 23 January 2020
| Date released: 10/02/2019 | Download: ML19261A834 |
|---|---|
| ML19261A838 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities |
| Issue date: | 01/16/1979 |
| From: | Tietz G COMMONWEALTH EDISON CO. |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| Download: ML19261A838 (2) | |
| ML19261A833 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities |
| Issue date: | 01/16/1979 |
| From: | Kalivianakis N COMMONWEALTH EDISON CO. |
| To: | KEPPLER J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| Download: ML19261A833 (1) | |