ML19261A834: Difference between revisions

From kanterella
Jump to navigation Jump to search
Created page by program invented by StriderTol
 
Created page by program invented by StriderTol
 
Line 6: Line 6:
| number = ML19261A838
| number = ML19261A838
| issue date = 01/16/1979
| issue date = 01/16/1979
| title = Forwards LER 78-039/03L-0
| title = LER 78-039/03L-0 on 781218:test Results Found HPCI Initiation Switches Associated W/Drywell Pressure Instruments Not in Accordance W/Tech Specs.Caused by Procedural Inadequacy;Switches Excluded from Test Program
| author name = Tietz G
| author name = Tietz G
| author affiliation = COMMONWEALTH EDISON CO.
| author affiliation = COMMONWEALTH EDISON CO.

Latest revision as of 12:25, 23 January 2020

Forwards LER 78-039/03L-0
Date released: 10/02/2019 Download: ML19261A834


LER 78-039/03L-0 on 781218:test Results Found HPCI Initiation Switches Associated W/Drywell Pressure Instruments Not in Accordance W/Tech Specs.Caused by Procedural Inadequacy;Switches Excluded from Test Program
ML19261A838
Person / Time
Site: Quad Cities 
Issue date: 01/16/1979
From: Tietz G
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19261A838 (2)
Forwards LER 78-039/03L-0
ML19261A833
Person / Time
Site: Quad Cities 
Issue date: 01/16/1979
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19261A833 (1)