{{#Wiki_filter:OFFICIAL USE ONLY | {{#Wiki_filter:OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | ||
- SECURITY RELATED INFORMATION | April 6, 2010 | ||
Mr. David W. Turner | |||
Vallecitos Nuclear Center | |||
General Electric Company | |||
6705 Vallecitos Road | |||
Mr. David W. Turner | Sunol, CA 94586 | ||
Vallecitos Nuclear Center | SUBJECT: GENERAL ELECTRIC COMPANY - NRC SECURITY INSPECTION REPORT | ||
General Electric Company | NO. 50-073/2010-201 | ||
6705 Vallecitos Road | Dear Mr. Turner: | ||
Sunol, CA | On March 22-25, 2010, the U.S. Nuclear Regulatory Commission (NRC) completed a security | ||
inspection at your General Electric Vallecitos Nuclear Center. The inspection included a review | |||
of activities authorized for your facility. The enclosed report presents the results of that | |||
inspection. | |||
The inspection examined activities conducted under your license as they relate to security and | |||
compliance with the Commission=s rules and regulations and with the conditions of your license. | |||
The inspector reviewed selected procedures and records, observed activities, and interviewed | |||
personnel. | |||
A licensee-identified violation was determined to be of very low safety significance is listed in this | |||
report. Because of the very low safety significance and because it has been addressed through | |||
corrective actions, the NRC is treating this violation as a non-cited violation (NCV) consistent | |||
with Section VI.A.1 of the NRC Enforcement Policy. If you contest this non-cited violation, you | |||
should provide a response within 30 days of the date of this inspection report, with the basis for | |||
your denial to the Nuclear Regulatory Commission, ATTN.: Document Control Desk, | |||
Washington, DC 20555-0001, with copies to the Director, Office of Nuclear Reactor Regulation, | |||
the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, | |||
DC 20555-0001. | |||
In accordance with 10 CFR Section 2.390 Public inspections, exemptions and requests for | |||
withholding, a copy of this letter will be available electronically for public inspection in the NRC | |||
Public Document Room or from the Publicly Available Records (PARS) component of NRC's | |||
document system (ADAMS). ADAMS is accessible from the NRC Website at | |||
http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, | |||
because of the security-related items contained in the enclosure, and in accordance with | |||
10 CFR Section 2.390, a copy of this letter=s enclosure will not be available for public inspection. | |||
Document transmitted herewith contains | |||
security-related information. When separated | |||
from the enclosure, this letter is uncontrolled | |||
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | |||
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | |||
-2- | |||
In accordance with 10 CFR Section 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements | |||
for your response, if any. This practice will ensure that your response will not be made available | |||
electronically for public inspection in the NRC Public Document Room or from the NRCs | |||
document system, ADAMS. If Safeguards Information is necessary to provide an acceptable | |||
response, please provide the level of protection described in 10 CFR Section 73.21. | |||
Should you have any questions concerning this inspection, please contact Gregory M. | |||
Schoenebeck at 301-415-6345. | |||
Sincerely, | |||
/RA/ | |||
Johnny H. Eads, Jr., Chief | |||
Research and Test Reactors Oversight Branch | |||
Division of Policy and Rulemaking | |||
Office of Nuclear Reactor Regulation | |||
Document transmitted herewith contains | |||
Docket No. 50-73 security-related information. When separated | |||
License No. R-33 from the enclosure, this letter is uncontrolled | |||
Non-public Enclosure: | |||
NRC Inspection Report No. 50-73/2010-201 | |||
cc: w/o encl: see next page | |||
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | |||
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | |||
General Electric Docket No. 50-73 | |||
cc: | |||
of | Mr. Donald Krause, Manager | ||
Regulatory Compliance and EHS | |||
Vallecitos Nuclear Center | |||
General Electric Company | |||
6705 Vallecitos Road | |||
Sunol, CA 94586 | |||
Mr. Dan Thomas | |||
Manager NTR | |||
Vallecitos Nuclear Center | |||
General Electric Company | |||
6705 Vallecitos Road | |||
Sunol, CA 94586 | |||
Mr. Harold Neems | |||
General Electric Company | |||
Nuclear Energy Business Operations | |||
175 Cutner Avenue | |||
Mail Code 123 | |||
San Jose, CA 95125 | |||
Commissioner | |||
California Energy Commission | |||
1516 Ninth Street, MS-34 | |||
Sacramento, CA 95814 | |||
California Department of Health | |||
ATTN: Chief | |||
Radiologic Health Branch | |||
P.O. Box 997414, MS 7610 | |||
Sacramento, CA 95899-7414 | |||
Test, Research, and Training | |||
Reactor Newsletter | |||
University of Florida | |||
202 Nuclear Sciences Center | |||
Gainesville, FL 32611 | |||
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | |||
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | |||
-2- | |||
In accordance with 10 CFR Section 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements | |||
for your response, if any. This practice will ensure that your response will not be made available | |||
electronically for public inspection in the NRC Public Document Room or from the NRCs | |||
document system, ADAMS. If Safeguards Information is necessary to provide an acceptable | |||
response, please provide the level of protection described in 10 CFR Section 73.21. | |||
Should you have any questions concerning this inspection, please contact Gregory M. | |||
Schoenebeck at 301-415-6345. | |||
Sincerely, | |||
/RA/ | |||
Johnny H. Eads, Jr., Chief | |||
Research and Test Reactors Oversight Branch | |||
Division of Policy and Rulemaking | |||
Office of Nuclear Reactor Regulation | |||
Document transmitted herewith contains | |||
Docket No. 50-73 security-related information. When separated | |||
License No. R-33 from the enclosure, this letter is uncontrolled | |||
Non-public Enclosure: | |||
NRC Inspection Report No. 50-73/2010-201 | |||
cc: w/o encl: see next page | |||
DISTRIBUTION: | |||
PUBLIC PRTA Reading File RidsNrrDprPrta RidsNrrDprPrtb | |||
RidsOgcMailCenter MCompton (cover letter only)(O13E19) GLappert, NRR | |||
GSchoenebeck, NRR WKennedy, NRR LTran, NRR | |||
Accession Nos.: P: ML100910157 L: ML100910146 E: ML100910240 (NON-PUBLIC) NRC-002 | |||
OFFICE PROB PRPB:LA PROB:BC | |||
NAME GSchoenebeck GLappert JEads | |||
DATE 4/1/2010 4/5/2010 4/6/2010 | |||
OFFICIAL RECORD COPY | |||
OFFICIAL USE ONLY | OFFICIAL USE ONLY- SECURITY RELATED INFORMATION | ||
- SECURITY RELATED INFORMATION | |||
document system, ADAMS. | |||
response, please provide the level of protection described in 10 CFR Section 73.21. | |||
Should you have any questions concerning this inspection, please contact Gregory M. | |||
Schoenebeck at 301-415-6345. | |||
Research and Test Reactors Oversight Branch | |||
Division of Policy and Rulemaking | |||
Office of Nuclear Reactor Regulation | |||
Docket No. 50-73 | |||
security-related information. | |||
from the enclosure, this letter is uncontrolled | |||
Non-public Enclosure: | |||
NRC Inspection Report No. 50-73/2010-201 | |||
cc: | |||
DISTRIBUTION | |||
GSchoenebeck, NRR WKennedy, NRR | |||
Accession Nos.: | |||
}} | }} |
Latest revision as of 20:14, 13 November 2019
ML100910146 | |
Person / Time | |
---|---|
Site: | Vallecitos Nuclear Center |
Issue date: | 04/06/2010 |
From: | Johnny Eads Research and Test Reactors Branch B |
To: | Doreen Turner General Electric Co |
Schoenebeck G, NRR/DPR, 415-6345 | |
Shared Package | |
ML100910157 | List: |
References | |
IR-10-201 | |
Download: ML100910146 (4) | |
See also: IR 05000073/2010201
Text
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION
April 6, 2010
Mr. David W. Turner
Vallecitos Nuclear Center
General Electric Company
6705 Vallecitos Road
Sunol, CA 94586
SUBJECT: GENERAL ELECTRIC COMPANY - NRC SECURITY INSPECTION REPORT
NO. 50-073/2010-201
Dear Mr. Turner:
On March 22-25, 2010, the U.S. Nuclear Regulatory Commission (NRC) completed a security
inspection at your General Electric Vallecitos Nuclear Center. The inspection included a review
of activities authorized for your facility. The enclosed report presents the results of that
inspection.
The inspection examined activities conducted under your license as they relate to security and
compliance with the Commission=s rules and regulations and with the conditions of your license.
The inspector reviewed selected procedures and records, observed activities, and interviewed
personnel.
A licensee-identified violation was determined to be of very low safety significance is listed in this
report. Because of the very low safety significance and because it has been addressed through
corrective actions, the NRC is treating this violation as a non-cited violation (NCV) consistent
with Section VI.A.1 of the NRC Enforcement Policy. If you contest this non-cited violation, you
should provide a response within 30 days of the date of this inspection report, with the basis for
your denial to the Nuclear Regulatory Commission, ATTN.: Document Control Desk,
Washington, DC 20555-0001, with copies to the Director, Office of Nuclear Reactor Regulation,
the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington,
DC 20555-0001.
In accordance with 10 CFR Section 2.390 Public inspections, exemptions and requests for
withholding, a copy of this letter will be available electronically for public inspection in the NRC
Public Document Room or from the Publicly Available Records (PARS) component of NRC's
document system (ADAMS). ADAMS is accessible from the NRC Website at
http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However,
because of the security-related items contained in the enclosure, and in accordance with
10 CFR Section 2.390, a copy of this letter=s enclosure will not be available for public inspection.
Document transmitted herewith contains
security-related information. When separated
from the enclosure, this letter is uncontrolled
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION
-2-
In accordance with 10 CFR Section 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements
for your response, if any. This practice will ensure that your response will not be made available
electronically for public inspection in the NRC Public Document Room or from the NRCs
document system, ADAMS. If Safeguards Information is necessary to provide an acceptable
response, please provide the level of protection described in 10 CFR Section 73.21.
Should you have any questions concerning this inspection, please contact Gregory M.
Schoenebeck at 301-415-6345.
Sincerely,
/RA/
Johnny H. Eads, Jr., Chief
Research and Test Reactors Oversight Branch
Division of Policy and Rulemaking
Office of Nuclear Reactor Regulation
Document transmitted herewith contains
Docket No. 50-73 security-related information. When separated
License No. R-33 from the enclosure, this letter is uncontrolled
Non-public Enclosure:
NRC Inspection Report No. 50-73/2010-201
cc: w/o encl: see next page
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION
General Electric Docket No. 50-73
cc:
Mr. Donald Krause, Manager
Regulatory Compliance and EHS
Vallecitos Nuclear Center
General Electric Company
6705 Vallecitos Road
Sunol, CA 94586
Mr. Dan Thomas
Manager NTR
Vallecitos Nuclear Center
General Electric Company
6705 Vallecitos Road
Sunol, CA 94586
Mr. Harold Neems
General Electric Company
Nuclear Energy Business Operations
175 Cutner Avenue
Mail Code 123
San Jose, CA 95125
Commissioner
California Energy Commission
1516 Ninth Street, MS-34
Sacramento, CA 95814
California Department of Health
ATTN: Chief
Radiologic Health Branch
P.O. Box 997414, MS 7610
Sacramento, CA 95899-7414
Test, Research, and Training
Reactor Newsletter
University of Florida
202 Nuclear Sciences Center
Gainesville, FL 32611
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION
OFFICIAL USE ONLY- SECURITY RELATED INFORMATION
-2-
In accordance with 10 CFR Section 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements
for your response, if any. This practice will ensure that your response will not be made available
electronically for public inspection in the NRC Public Document Room or from the NRCs
document system, ADAMS. If Safeguards Information is necessary to provide an acceptable
response, please provide the level of protection described in 10 CFR Section 73.21.
Should you have any questions concerning this inspection, please contact Gregory M.
Schoenebeck at 301-415-6345.
Sincerely,
/RA/
Johnny H. Eads, Jr., Chief
Research and Test Reactors Oversight Branch
Division of Policy and Rulemaking
Office of Nuclear Reactor Regulation
Document transmitted herewith contains
Docket No. 50-73 security-related information. When separated
License No. R-33 from the enclosure, this letter is uncontrolled
Non-public Enclosure:
NRC Inspection Report No. 50-73/2010-201
cc: w/o encl: see next page
DISTRIBUTION:
PUBLIC PRTA Reading File RidsNrrDprPrta RidsNrrDprPrtb
RidsOgcMailCenter MCompton (cover letter only)(O13E19) GLappert, NRR
GSchoenebeck, NRR WKennedy, NRR LTran, NRR
Accession Nos.: P: ML100910157 L: ML100910146 E: ML100910240 (NON-PUBLIC) NRC-002
OFFICE PROB PRPB:LA PROB:BC
NAME GSchoenebeck GLappert JEads
DATE 4/1/2010 4/5/2010 4/6/2010
OFFICIAL RECORD COPY