Line 6: | Line 6: | ||
| number = ML17266A217 | | number = ML17266A217 | ||
| issue date = 06/10/1980 | | issue date = 06/10/1980 | ||
| title = | | title = LER 80-023/03L-0:on 800511,during Power Ascension,Control Element Assemblies 19 & 58 Dropped to Full Insertion.Caused by Failure of 15-volt Power Supply Units.Both Control Element Assemblies Were Restored | ||
| author name = Schoppman M | | author name = Schoppman M | ||
| author affiliation = FLORIDA POWER & LIGHT CO. | | author affiliation = FLORIDA POWER & LIGHT CO. |
Latest revision as of 11:02, 8 March 2020
Date released: 01/25/2018 | Download: ML17208A733 |
---|---|
ML17266A217 | |
Person / Time | |
---|---|
Site: | Saint Lucie |
Issue date: | 06/10/1980 |
From: | Schoppman M FLORIDA POWER & LIGHT CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML17266A217 (2) | |
ML17208A732 | |
Person / Time | |
---|---|
Site: | Saint Lucie |
Issue date: | 06/10/1980 |
From: | Schmidt A FLORIDA POWER & LIGHT CO. |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML17208A732 (1) | |