ML17256A400: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
Line 6: Line 6:
| number = ML17256A405
| number = ML17256A405
| issue date = 11/30/1982
| issue date = 11/30/1982
| title = Forwards Response to NUREG-0916 Re Restart After 820125 Tube Rupture Incident.Based on Response to Item 2C(2),revised Tech Specs Re Primary Coolant Activity Will Be Requested
| title = Evaluation of Potential Stagnation Transients & Scenarios for Re Ginna Nuclear Power Plant.
| author name = Monty B
| author name = Monty B
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Line 21: Line 21:
| number = ML17256A404
| number = ML17256A404
| issue date = 11/30/1982
| issue date = 11/30/1982
| title = Forwards Response to NUREG-0916 Re Restart After 820125 Tube Rupture Incident.Based on Response to Item 2C(2),revised Tech Specs Re Primary Coolant Activity Will Be Requested
| title = Evaluation of Reactor Coolant Pump Restart Requirements Following Steam Generator Tube Failure at Re Ginna Nuclear Power Plant.
| author name = Volpenhein E
| author name = Volpenhein E
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Line 36: Line 36:
| number = ML17256A403
| number = ML17256A403
| issue date = 11/30/1982
| issue date = 11/30/1982
| title = Forwards Response to NUREG-0916 Re Restart After 820125 Tube Rupture Incident.Based on Response to Item 2C(2),revised Tech Specs Re Primary Coolant Activity Will Be Requested
| title = Evaluation of Alternative Reactor Coolant Pump Trip Criteria for Re Ginna Nuclear Power Plant.
| author name = Lewis R
| author name = Lewis R
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Line 51: Line 51:
| number = ML17256A402
| number = ML17256A402
| issue date = 11/22/1982
| issue date = 11/22/1982
| title = Forwards Response to NUREG-0916 Re Restart After 820125 Tube Rupture Incident.Based on Response to Item 2C(2),revised Tech Specs Re Primary Coolant Activity Will Be Requested
| title = Analysis of Plant Response During 820125 Steam Generator Tube Failure at Re Ginna Nuclear Power Plant.
| author name = Volpenhein E
| author name = Volpenhein E
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Line 66: Line 66:
| number = ML17256A401
| number = ML17256A401
| issue date = 11/30/1982
| issue date = 11/30/1982
| title = Forwards Response to NUREG-0916 Re Restart After 820125 Tube Rupture Incident.Based on Response to Item 2C(2),revised Tech Specs Re Primary Coolant Activity Will Be Requested
| title = Analysis of Potential Environ Consequences Following Steam Generator Tube Failure at Re Ginna Nuclear Power Plant.
| author name = Rubin K, Volpenhein E
| author name = Rubin K, Volpenhein E
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
| author affiliation = WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.

Latest revision as of 03:40, 8 March 2020

Forwards Response to NUREG-0916 Re Restart After 820125 Tube Rupture Incident.Based on Response to Item 2C(2),revised Tech Specs Re Primary Coolant Activity Will Be Requested
Date released: 04/30/2018 Download: ML17256A400


Evaluation of Potential Stagnation Transients & Scenarios for Re Ginna Nuclear Power Plant.
ML17256A405
Person / Time
Site: Ginna Constellation icon.png
Issue date: 11/30/1982
From: Monty B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17256A405 (28)
Evaluation of Reactor Coolant Pump Restart Requirements Following Steam Generator Tube Failure at Re Ginna Nuclear Power Plant.
ML17256A404
Person / Time
Site: Ginna Constellation icon.png
Issue date: 11/30/1982
From: Volpenhein E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17256A404 (23)
Evaluation of Alternative Reactor Coolant Pump Trip Criteria for Re Ginna Nuclear Power Plant.
ML17256A403
Person / Time
Site: Ginna Constellation icon.png
Issue date: 11/30/1982
From: Robert Lewis
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17256A403 (131)
Analysis of Plant Response During 820125 Steam Generator Tube Failure at Re Ginna Nuclear Power Plant.
ML17256A402
Person / Time
Site: Ginna Constellation icon.png
Issue date: 11/22/1982
From: Volpenhein E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17256A402 (91)
Analysis of Potential Environ Consequences Following Steam Generator Tube Failure at Re Ginna Nuclear Power Plant.
ML17256A401
Person / Time
Site: Ginna Constellation icon.png
Issue date: 11/30/1982
From: Rubin K, Volpenhein E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17256A401 (17)
Forwards Response to NUREG-0916 Re Restart After 820125 Tube Rupture Incident.Based on Response to Item 2C(2),revised Tech Specs Re Primary Coolant Activity Will Be Requested
ML17256A399
Person / Time
Site: Ginna Constellation icon.png
Issue date: 11/22/1982
From: Maier J
ROCHESTER GAS & ELECTRIC CORP.
To: CRUTCHFIELD D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0916, RTR-NUREG-916