| docket = 05000373, 05000374 | | docket = 05000373, 05000374 | ||
| license number = NPF-011, NPF-018 | | license number = NPF-011, NPF-018 | ||
| contact person = Sands S | | contact person = Sands S,NRR/DLPM, 415-3154 | ||
| case reference number = TAC MD0540, TAC MD0541 | | case reference number = TAC MD0540, TAC MD0541 | ||
| package number = ML071690253 | | package number = ML071690253 | ||
Line 19: | Line 19: | ||
=Text= | =Text= | ||
{{#Wiki_filter:Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 2 of 4)Primary Containment Isolation Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION C.1 REQUIREMENTS VALUE 2. Primary Containment Isolation (continued) | {{#Wiki_filter:Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 2 of 4) | ||
: e. Reactor Vessel Water | Primary Containment Isolation Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION C.1 REQUIREMENTS VALUE | ||
: 2. Primary Containment Isolation (continued) | |||
: | : e. Reactor Vessel Water 1,2,3 2 F SR 3.3.6.1.1 -137.0 inches Level-Low Low Low, SR 3.3.6.1.2 Level I SR 3.3.6.1.4 SR 3.3.6.1.5 | ||
: | : f. Reactor Vessel Water 1,2,3 2 F SR 3.3.6.1.1 Ž 11.0 inches Level-Low, Level 3 SR 3.3.6.1.2 SR 3.3.6.1.4 SR 3.3.6.1.5 | ||
: g. Manual Initiation 1,2,3 1 G SR 3.3.6.1'.5 NA | |||
: 3. Reactor Core Isolation Cooling (RCIC) System Isolation | |||
: a. RCIC Steam Line 1,2,3 1 . F SR 3.3.6.1.2 176.0 inches Flow-High SR 3.3.6.1.3 water SR 3.3.6.1.5 | |||
: b. RCIC Steam Line 1,2,3 F SR 3.3.6.1.2 2.6 seconds and Flow-Timer SR 3.3.6.1.4 : 5.5 seconds SR 3.3.6.1.5 | |||
: c. RCIC Steam Supply 1.2.3 2 F SR 3.3.6.1.2 >_ 58.2 psig Pressure-Low SR 3.3.6.1.4 SR 3.3.6.1.5 | |||
LaSalle 1 and 2 3.3.6.1-7 Amendment No. /182/169}} | : d. RCIC Turbine Exhaust 1,2,3 F SR 3.3.6.1.2 5 300 inches water Diaphragm Pressure-High SR 3.3.6.1.4 SR 3.3.6.1.5 | ||
: e. RCIC Equipment Room 1,2,3 I F SR 3.3.6.1.1 :5 297.01F Temperature-High SR 3.3.6.1.2 SR 3.3.6.1.4 SR 3.3.6.1.5 | |||
: f. RCIC Equipment Room 1.2,3 SR 3.3.6.1.1 :s 188.0*F Differential SR 3.3.6.1.2 Temperature-High SR 3.3.6.1.4 SR 3.3.6.1.5 | |||
: g. RCIC Steam Line Tunnel 1,2.3 SR 3.3.6.1.1 5 267.0*F Temperature-High SR 3.3.6.1.2 SR 3.3.6.1.4 SR 3.3.6.1.5 | |||
: h. RCIC Steam Line Tunnel 1,2,3 1 F SR 3.3.6.1.1 -q 163.6-F Differential SR 3.3.6.1.2 Temperature-High SR 3.3.6.1.4 SR 3.3.6.1.5 | |||
: i. Drywell Pressure-High 1.2.3 F SR 3.3.6.1.2 1.77 psig SR 3.3.6.1.4 SR 3.3.6.1.5 (continued) | |||
LaSalle 1 and 2 3.3.6.1-7 Amendment No. / | |||
182/169}} |
Latest revision as of 04:56, 23 November 2019
ML071830450 | |
Person / Time | |
---|---|
Site: | LaSalle |
Issue date: | 06/29/2007 |
From: | NRC/NRR/ADRO/DORL/LPLIII-2 |
To: | |
Sands S,NRR/DLPM, 415-3154 | |
Shared Package | |
ML071690253 | List: |
References | |
TAC MD0540, TAC MD0541 | |
Download: ML071830450 (1) | |
Text
Primary Containment Isolation Instrumentation 3.3.6.1 Table 3.3.6.1-1 (page 2 of 4)
Primary Containment Isolation Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER TRIP REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS SYSTEM ACTION C.1 REQUIREMENTS VALUE
- 2. Primary Containment Isolation (continued)
- e. Reactor Vessel Water 1,2,3 2 F SR 3.3.6.1.1 -137.0 inches Level-Low Low Low, SR 3.3.6.1.2 Level I SR 3.3.6.1.4 SR 3.3.6.1.5
- f. Reactor Vessel Water 1,2,3 2 F SR 3.3.6.1.1 Ž 11.0 inches Level-Low, Level 3 SR 3.3.6.1.2 SR 3.3.6.1.4 SR 3.3.6.1.5
- g. Manual Initiation 1,2,3 1 G SR 3.3.6.1'.5 NA
- 3. Reactor Core Isolation Cooling (RCIC) System Isolation
- a. RCIC Steam Line 1,2,3 1 . F SR 3.3.6.1.2 176.0 inches Flow-High SR 3.3.6.1.3 water SR 3.3.6.1.5
- b. RCIC Steam Line 1,2,3 F SR 3.3.6.1.2 2.6 seconds and Flow-Timer SR 3.3.6.1.4 : 5.5 seconds SR 3.3.6.1.5
- c. RCIC Steam Supply 1.2.3 2 F SR 3.3.6.1.2 >_ 58.2 psig Pressure-Low SR 3.3.6.1.4 SR 3.3.6.1.5
- d. RCIC Turbine Exhaust 1,2,3 F SR 3.3.6.1.2 5 300 inches water Diaphragm Pressure-High SR 3.3.6.1.4 SR 3.3.6.1.5
- e. RCIC Equipment Room 1,2,3 I F SR 3.3.6.1.1 :5 297.01F Temperature-High SR 3.3.6.1.2 SR 3.3.6.1.4 SR 3.3.6.1.5
- f. RCIC Equipment Room 1.2,3 SR 3.3.6.1.1 :s 188.0*F Differential SR 3.3.6.1.2 Temperature-High SR 3.3.6.1.4 SR 3.3.6.1.5
- g. RCIC Steam Line Tunnel 1,2.3 SR 3.3.6.1.1 5 267.0*F Temperature-High SR 3.3.6.1.2 SR 3.3.6.1.4 SR 3.3.6.1.5
- h. RCIC Steam Line Tunnel 1,2,3 1 F SR 3.3.6.1.1 -q 163.6-F Differential SR 3.3.6.1.2 Temperature-High SR 3.3.6.1.4 SR 3.3.6.1.5
- i. Drywell Pressure-High 1.2.3 F SR 3.3.6.1.2 1.77 psig SR 3.3.6.1.4 SR 3.3.6.1.5 (continued)
LaSalle 1 and 2 3.3.6.1-7 Amendment No. /
182/169