{{Adams
#REDIRECT [[CPSES-200700915, Supplemental Response to Request for Information on Generic Letter 2003-01, Control Room Habitability]]
| number = ML071360077
| issue date = 05/07/2007
| title = Supplemental Response to Request for Information on Generic Letter 2003-01, Control Room Habitability
| author name = Blevins M, Madden F W
| author affiliation = TXU Generation Co, LP, TXU Power
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR/ADRO
| docket = 05000445, 05000446
| license number =
| contact person =
| case reference number = CPSES-200700915, GL-03-001, TXX-07089
| document type = Letter
| page count = 2
}}
 
=Text=
{{#Wiki_filter:STXU w Power 1XU Potwer Comanche Steam Electic Station P. O. Box (EO1)Glen Rose, TX 76043 Tel: 254 897 5209 Fax: 254 897 6652 mike.blevins@btu.com MEke Blevms Senor Vice President
&Ptbx*a Nuclear Officer CPSES-200700915 Log # TXX-07089 May 7, 2007 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
 
==SUBJECT:==
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)DOCKET NOS. 50-445 & 50-446 SUPPLEMENTAL RESPONSE TO REQUEST FOR INFORMATION ON GENERIC LETTER 2003-01, CONTROL ROOM HABITABILITY REF: (1) TXX-03158, Letter from M. R. Blevins to the NRC Document Control Desk, "Response to Request for Information on Generic Letter 2003-01, Control Room Habitability," dated December 4, 2003 (2) NRC Generic Letter 2003-01 "Control Room Habitability," dated June 12, 2003 (3) TXX-05040, Letter from M. R. Blevins to the NRC Document Control Desk, "Supplemental Response to Request for Information on Generic Letter 2003-01, Control Room Habitability," dated March 3, 2005 Gentlemen:
Reference 1 provided TXU Generation Company LP's (TXU Power's) response to NRC Generic Letter 2003-01, "Control Room Habitability" (Reference 2). TXU Power provided a supplemental response (Reference
: 3) which identified the following commitment.
27329 Bubble tight dampers are planned to be installed to reduce the filtered in-leakage (to the Control Room Envelope) and provide an effective isolation mode for the control room HVAC system. This modification is expected to be completed in 2005.A member of the STARS (Strategic Teaming and Resource Sharing) Alliance tA-2~Callaway e Comanche Peak e Diablo Canyon
* Palo Verde o South Texas Project ° Wolf Creek TXX-07089 Page 2 of 2 This commitment number is used by TXU Power for the internal tracking of CPSES commitments which are one time action requirements.
As a result of recent conversations with the NRC Staff, TXU Power is providing an update to report that the bubble tight damper modification was completed in 2005 and this commitment is closed.If you should have any questions regarding this submittal, please contact Mr. Carl Corbin at (254) 897-0121.Sincerely, TXU Generation Company LP By: TXU Generation Management Company LLC Its General Partner Mike Blevins By: ,/Fred W. Madden Director, Oversight and Regulatory Affairs CBC c -B. S. Mallet, Region IV M.C. Thadani, NRR Resident Inspectors, CPSES}}