ML18038B767: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Adams package
{{Adams package
| number = ML18038B767
| number = ML18038B767
| title = Forwards LER 96-004-01,clarifying Analysis of Event Section Which Div I & Ii ECCS Equipment Remained Operable for Automatic Initiation
| title = Forwards LER 96-004-01,clarifying Analysis of Event Section Which Div I & II ECCS Equipment Remained Operable for Automatic Initiation
| release date = 09/27/2018
| release date = 09/27/2018
| package contents = {{Adams package content
| package contents = {{Adams package content
| number = ML18038B768
| number = ML18038B768
| issue date = 09/30/1996
| issue date = 09/30/1996
| title = Forwards LER 96-004-01,clarifying Analysis of Event Section Which Div I & Ii ECCS Equipment Remained Operable for Automatic Initiation
| title = LER 96-004-01:on 960717,ECCS Atu Inverter Power Was Lost as a Result of a Failed Control Board in ECCS Division I Atu Inverter.Cleared Fuse,Shorted SCR & Failed Inverter Control Board Were Replaced
| author name = WALLACE J E
| author name = Wallace J
| author affiliation = TENNESSEE VALLEY AUTHORITY
| author affiliation = TENNESSEE VALLEY AUTHORITY
| addressee name =  
| addressee name =  
Line 21: Line 21:
| number = ML18038B766
| number = ML18038B766
| issue date = 09/30/1996
| issue date = 09/30/1996
| title = Forwards LER 96-004-01,clarifying Analysis of Event Section Which Div I & Ii ECCS Equipment Remained Operable for Automatic Initiation
| title = Forwards LER 96-004-01,clarifying Analysis of Event Section Which Div I & II ECCS Equipment Remained Operable for Automatic Initiation
| author name = MACHON R D
| author name = Machon R
| author affiliation = TENNESSEE VALLEY AUTHORITY
| author affiliation = TENNESSEE VALLEY AUTHORITY
| addressee name =  
| addressee name =  

Latest revision as of 06:01, 6 March 2020

Forwards LER 96-004-01,clarifying Analysis of Event Section Which Div I & II ECCS Equipment Remained Operable for Automatic Initiation
Date released: 09/27/2018 Download: ML18038B767


LER 96-004-01:on 960717,ECCS Atu Inverter Power Was Lost as a Result of a Failed Control Board in ECCS Division I Atu Inverter.Cleared Fuse,Shorted SCR & Failed Inverter Control Board Were Replaced
ML18038B768
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 09/30/1996
From: Jay Wallace
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML18038B768 (12)
Forwards LER 96-004-01,clarifying Analysis of Event Section Which Div I & II ECCS Equipment Remained Operable for Automatic Initiation
ML18038B766
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 09/30/1996
From: Machon R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18038B766 (6)