Line 6: Line 6:
| number = ML17292A611
| number = ML17292A611
| issue date = 07/12/1996
| issue date = 07/12/1996
| title = Responds to Request for MOV Actuator Capability Calculations for HPCS Injection Valve HPCS-V-4 & RCIC Suppression Pool Suction Valve RCIC-V-31
| title = Rev 0 to Pressure Locking Evaluation for RCIC-V-31.
| author name = KELSOW W H
| author name = Kelsow W
| author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM
| author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM
| addressee name =  
| addressee name =  
Line 21: Line 21:
| number = ML17292A610
| number = ML17292A610
| issue date = 07/12/1996
| issue date = 07/12/1996
| title = Responds to Request for MOV Actuator Capability Calculations for HPCS Injection Valve HPCS-V-4 & RCIC Suppression Pool Suction Valve RCIC-V-31
| title = Rev 0 to MOV Pressure Locking Calculation.
| author name =  
| author name =  
| author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM
| author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM
Line 37: Line 37:
| issue date = 11/25/1996
| issue date = 11/25/1996
| title = Responds to Request for MOV Actuator Capability Calculations for HPCS Injection Valve HPCS-V-4 & RCIC Suppression Pool Suction Valve RCIC-V-31
| title = Responds to Request for MOV Actuator Capability Calculations for HPCS Injection Valve HPCS-V-4 & RCIC Suppression Pool Suction Valve RCIC-V-31
| author name = PARRISH J V
| author name = Parrish J
| author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM
| author affiliation = WASHINGTON PUBLIC POWER SUPPLY SYSTEM
| addressee name =  
| addressee name =  

Latest revision as of 17:51, 7 March 2020

Responds to Request for MOV Actuator Capability Calculations for HPCS Injection Valve HPCS-V-4 & RCIC Suppression Pool Suction Valve RCIC-V-31
Date released: 06/27/2018 Download: ML17292A609


Rev 0 to Pressure Locking Evaluation for RCIC-V-31.
ML17292A611
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 07/12/1996
From: Kelsow W
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
References
Download: ML17292A611 (26)
Rev 0 to MOV Pressure Locking Calculation.
ML17292A610
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 07/12/1996
From:
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
References
Download: ML17292A610 (25)
Responds to Request for MOV Actuator Capability Calculations for HPCS Injection Valve HPCS-V-4 & RCIC Suppression Pool Suction Valve RCIC-V-31
ML17292A608
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 11/25/1996
From: Parrish J
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17292A608 (8)