| number = ML18023A068
| title = Discusses Results of Review of Westinghouse Topical Rept WCAP-13632,Rev 2, Elimination of Pressure Sensor Response Time Testing Requirements, Dtd Aug 1995.Rept Discusses Westinghouse Owners Group Program MUHP-3040,Rev 1
| title = Discusses Results of Review of Westinghouse Topical Rept WCAP-13632,Rev 2, Elimination of Pressure Sensor Response Time Testing Requirements, Dtd Aug 1995.Rept Discusses Westinghouse Owners Group Program MUHP-3040,Rev 1
| release date = 05/10/2018
| package contents = {{Adams package content
| package contents = {{Adams package content
| number = ML18128A308
| number = ML18128A308
| issue date = 09/05/1995
| issue date = 09/05/1995
| title = Discusses Results of Review of Westinghouse Topical Rept WCAP-13632,Rev 2, Elimination of Pressure Sensor Response Time Testing Requirements, Dtd Aug 1995.Rept Discusses Westinghouse Owners Group Program MUHP-3040,Rev 1
| title = Evaluation of Westinghouse Electric Corporation Topical Report (TR)WCAP-13632,Rev 2, Elimination of Pressure Sensor Response Time Testing (Rtt) Requirements.
| author name =  
| author name =  
| author affiliation = NRC/NRR
| author affiliation = NRC/NRR
Line 20: Line 21:
| number = ML18023A067
| number = ML18023A067
| issue date = 09/05/1995
| issue date = 09/05/1995
| title = Discusses Results of Review of Westinghouse Topical Rept WCAP-13632,Rev 2, Elimination of Pressure Sensor Response Time Testing Requirements, Dtd Aug 1995.Rept Discusses Westinghouse Owners Group Program MUHP-3040,Rev 1
| title = Review of Westinghouse Electric Corporation Topical Report (TR) WCAP-13632, Revision 2, Elimination of Pressure Sensor Response Time Testing (Rtt) Requirements, Dated August 1995 - Westinghouse Owners Group Program MUHP-3040, Revision 1
| author name = Boger B A
| author name = Boger B
| author affiliation = NRC/NRR
| author affiliation = NRC/NRR
| addressee name = Newton R A
| addressee name = Newton R A

Latest revision as of 13:19, 6 March 2020

Discusses Results of Review of Westinghouse Topical Rept WCAP-13632,Rev 2, Elimination of Pressure Sensor Response Time Testing Requirements, Dtd Aug 1995.Rept Discusses Westinghouse Owners Group Program MUHP-3040,Rev 1
Date released: 05/10/2018 Download: ML18023A068


Evaluation of Westinghouse Electric Corporation Topical Report (TR)WCAP-13632,Rev 2, Elimination of Pressure Sensor Response Time Testing (Rtt) Requirements.
ML18128A308
Person / Time
Site: 05000668
Issue date: 09/05/1995
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML18128A308 (20)
Review of Westinghouse Electric Corporation Topical Report (TR) WCAP-13632, Revision 2, Elimination of Pressure Sensor Response Time Testing (Rtt) Requirements, Dated August 1995 - Westinghouse Owners Group Program MUHP-3040, Revision 1
ML18023A067
Person / Time
Issue date: 09/05/1995
From: Boger B
Office of Nuclear Reactor Regulation
To: Newton R A
Westinghouse Owners Group, Wisconsin Electric Power Co
References
Download: ML18023A067 (31)