{{#Wiki_filter:March 23, 2018 Mr. Joseph Raab EHS Director 220 Winspear Avenue South Campus | {{#Wiki_filter:March 23, 2018 Mr. Joseph Raab EHS Director 220 Winspear Avenue South Campus Buffalo, NY 14215-1034 | ||
Buffalo, NY 14215-1034 | |||
==SUBJECT:== | ==SUBJECT:== | ||
TERMINATION OF QUALITY ASSURANCE PROGRAM APPROVAL FOR RADIOACTIVE MATERIAL PACKAGES NO. | TERMINATION OF QUALITY ASSURANCE PROGRAM APPROVAL FOR RADIOACTIVE MATERIAL PACKAGES NO. 0226, REVISION 7 | ||
0226, REVISION 7 | |||
==Dear Mr. Raab:== | ==Dear Mr. Raab:== | ||
As requested in your letter dated January 29, 2018, Quality Assurance (QA) Program Approval No. 0226, Revision 7, is hereby terminated. Your general license under Title 10 of the Code of Federal Regulations (10 CFR) Part 71, Subpart C, to transport licensed material and your registration as a user of the U.S. Nuclear Regulatory Commission approved packagings under 10 CFR 71.17(c)(3) are also terminated. Therefore, you are no longer authorized to procure, maintain, repair, or use radioactive material packagings under 10 CFR Part 71. | As requested in your letter dated January 29, 2018, Quality Assurance (QA) Program Approval No. 0226, Revision 7, is hereby terminated. Your general license under Title 10 of the Code of Federal Regulations (10 CFR) Part 71, Subpart C, to transport licensed material and your registration as a user of the U.S. Nuclear Regulatory Commission approved packagings under 10 CFR 71.17(c)(3) are also terminated. Therefore, you are no longer authorized to procure, maintain, repair, or use radioactive material packagings under 10 CFR Part 71. | ||
If you wish to have your QA program approved in the future, please submit a request in writing, along with a description of your QA program, in accordance with the requirements of Subpart H of 10 CFR Part 71. | |||
If you wish to have your QA program approved in the future, please submit a request in writing, along with a description of your QA program, in accordance with the requirements of Subpart H of 10 CFR Part 71. | Please note that records required by 10 CFR 71.91 and 71.135 are to be retained for a period of three years. | ||
If you have any questions, please contact me at 301-415-7399 or Jeremy Tapp at 301-415-8047. | |||
Please note that records required by 10 CFR 71.91 and 71.135 are to be retained for a period of | Sincerely, | ||
/RA/ | |||
three years. | Meraj Rahimi, Acting Chief Inspections and Operations Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 71-0226 | ||
If you have any questions, please contact me at 301-415-7399 or Jeremy Tapp at 301-415-8047. | |||
Sincerely, | |||
Docket No.: | |||
ML18085A080 OFC: DSFM | ML18085A080 OFC: DSFM DSFM DSFM NAME: JTapp SFigueroa MRahimi DATE: 3/5/18 3/6/18 3/23/18}} |
Latest revision as of 14:00, 21 October 2019
ML18085A080 | |
Person / Time | |
---|---|
Site: | 07100226 |
Issue date: | 03/23/2018 |
From: | Meraj Rahimi NRC/NMSS/DSFM/IOB |
To: | Raab J University of Buffalo |
Tapp J | |
References | |
Download: ML18085A080 (2) | |
Text
March 23, 2018 Mr. Joseph Raab EHS Director 220 Winspear Avenue South Campus Buffalo, NY 14215-1034
SUBJECT:
TERMINATION OF QUALITY ASSURANCE PROGRAM APPROVAL FOR RADIOACTIVE MATERIAL PACKAGES NO. 0226, REVISION 7
Dear Mr. Raab:
As requested in your letter dated January 29, 2018, Quality Assurance (QA) Program Approval No. 0226, Revision 7, is hereby terminated. Your general license under Title 10 of the Code of Federal Regulations (10 CFR) Part 71, Subpart C, to transport licensed material and your registration as a user of the U.S. Nuclear Regulatory Commission approved packagings under 10 CFR 71.17(c)(3) are also terminated. Therefore, you are no longer authorized to procure, maintain, repair, or use radioactive material packagings under 10 CFR Part 71.
If you wish to have your QA program approved in the future, please submit a request in writing, along with a description of your QA program, in accordance with the requirements of Subpart H of 10 CFR Part 71.
Please note that records required by 10 CFR 71.91 and 71.135 are to be retained for a period of three years.
If you have any questions, please contact me at 301-415-7399 or Jeremy Tapp at 301-415-8047.
Sincerely,
/RA/
Meraj Rahimi, Acting Chief Inspections and Operations Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 71-0226
ML18085A080 OFC: DSFM DSFM DSFM NAME: JTapp SFigueroa MRahimi DATE: 3/5/18 3/6/18 3/23/18