EOP:AP-CR.1CONTROLROOMINACCESSIBILITYREV10PAGE6of6STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED12EstablishNormalControlRoomOperations:a.Restore-NORMALOPERATIONOFEQUIPMENToReferto0-2.2,PLANTFROMHSDTOCOLDSHUTDOWN-OR-oRefertoES-0.2,NATURALCIRCULATIONCOOLDOWN-END-s,1UI.Av EOP:AP-CR.1TITLE:CONTROLROOMINACCESSIBILITYREV:10PAGE1of1ATTACHMENTADutiesofPersonnelDuringaControlRoomEvacuationSHIFTSUPERVISOR-Willdirectoverallplantoperationsandrecoveryactions.NospecificdutystationisassignedbuttheShiftSupervisorshouldmaintaincommunicationwiththevariousgroupsworkingtorecoverfromtheevacuation.CONTROLROOMFOREMANIWillassist.theHeadControlOperatorintransferringequipmenttolocalcontrol,aftercompletionofthetransfertheControlRoomForemanwilldirecttheoper-ator'sactionstorecovertheplant.HEADCONTROLOPERATORWillgotoAuxiliaryFeedwaterpumpareatakingoperatingprocedures"O"book,officialrecords;curvebookwithhimandtransferequipmenttolocalcontrol.CONTROLOPERATORWillgotothelocaloperatingstationintheChargingPumpRoom.PRIMARYAUXOPERATOR-WillgotothelocaloperatingstationsintheBoricAcidTankRoom.SHIFTTECHNICALADVISORWillassisttheHeadControlOperatorwhileremainingcognizant".ofplantconditions.OTHERPERSONNEL-WillassumefirefightingorotherdutiesasdirectedbytheShiftSupervisororControlRoomForeman.
EOP:AP-CR.1CONTROLROOMINACCESSIBILITYREV10PAGE6of6STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED12EstablishNormalControlRoomOperations:a.Restore-NORMALOPERATIONOFEQUIPMENToReferto0-2.2,PLANTFROMHSDTOCOLDSHUTDOWN-OR-oRefertoES-0.2,NATURALCIRCULATIONCOOLDOWN-END-s,1UI.Av EOP:AP-CR.1TITLE:CONTROLROOMINACCESSIBILITYREV:10PAGE1of1ATTACHMENTADutiesofPersonnelDuringaControlRoomEvacuationSHIFTSUPERVISOR-Willdirectoverallplantoperationsandrecoveryactions.NospecificdutystationisassignedbuttheShiftSupervisorshouldmaintaincommunicationwiththevariousgroupsworkingtorecoverfromtheevacuation.CONTROLROOMFOREMANIWillassist.theHeadControlOperatorintransferringequipmenttolocalcontrol,aftercompletionofthetransfertheControlRoomForemanwilldirecttheoper-ator'sactionstorecovertheplant.HEADCONTROLOPERATORWillgotoAuxiliaryFeedwaterpumpareatakingoperatingprocedures"O"book,officialrecords;curvebookwithhimandtransferequipmenttolocalcontrol.CONTROLOPERATORWillgotothelocaloperatingstationintheChargingPumpRoom.PRIMARYAUXOPERATOR-WillgotothelocaloperatingstationsintheBoricAcidTankRoom.SHIFTTECHNICALADVISORWillassisttheHeadControlOperatorwhileremainingcognizant".ofplantconditions.OTHERPERSONNEL-WillassumefirefightingorotherdutiesasdirectedbytheShiftSupervisororControlRoomForeman.
Jyll,10  
Jyll,10}}
}}

Revision as of 12:52, 18 May 2018

Rev 10 to AP-CR.1, Control Room Inaccessibility.
ML17261B110
Person / Time
Site: Ginna Constellation icon.png
Issue date: 06/27/1990
From: WIDAY J A
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17261B111 List:
References
AP-CR.1, NUDOCS 9007310038
Download: ML17261B110 (14)


Text

EOP:AP-CR.1'-6/l9/0/CONTROLROOMINACCESSIBILITY/87//D&YOREV:10PAGE1f6ROCHESTERGASANDELECTRICCORPORATONGINNASTATIONONTROLLEDCOPYNUMBERCHNICALREIEWPORCREVIEWEgcoPTSUPERINNToEFFECTIVEDATECATEGO1.0REVIEDBY90073l003S900725!PDRADOCK0000244~!PPDCGIASTATIONSART:DATETIMECOIViPLETDATETIME:

t AP-CR.1CONTROLROOMINACCESSIBILITYREV:10PAGE2of6A.PURPOSE-ThisprocedureprovidesthestepnecessarytoplaceandmaintaintheplantinaHotShutdownConditionintheeventthatacontrolroomevacuationisnecessary.B.ENTRYCONDITIONS/SYMPTOMS1.SYMPTOMS-ThesymptomsofCONTROLROOMINACCESSIBILITYare;a.FireintheControlRoom,orb.SmokeintheControlRoom,orc.NoxiousFumesintheControlRoom,ord.Intrusion llIIFg,14~Aa EOP:AP-CR.1CONTROLROOMINACCESSIBILITYREV10PAGE3of6STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINEDNOTE:Steps1and2areimmediateactionsteps.O1VerifyReactorTrip:oReactortripbreakers-OPENoMRPIindicates-ALLCONTROLANDSHUTDOVNRODSONBOTTOMoNeutronflux-DECREASINGManualtripthereactorfromthecontrolboard.IFtheRxcanNOTbetrippedfromtheControlRoom,THENlocallyopenthereactortripbreakers.O2VerifyTurbineStopValves-CLOSEDManuallytripturbinefromMCB.IFturbinecanNOTbetrippedattheMCB,THENclosebothMSIVs.

l~~C-EOP:AP-CR.1CONTROLROOMINACCESSIBILITYREV:10PAGE4of6STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED3VerifyThatFireHASNOTSignificantlyDamagedTheMCBControlCircuitsoMCB-NOFIREORFIREUNDERCONTROLoSafetyrelatedcontrolsandindications-NOSIGNIFICANTLOSSOFCONTROLS/INDICATIONPerformthefollowingactions:a.ClosebothMSIVs.b.Tripbothreactorcoolantpumps.c.ClosebothPRZRreliefvalves,PCV-430(431C).d.ProceedtotheAppendixRlocker,immediatelyoutsidetheControlRoom.e.ControlRoomForemanandcommunicatorproceedtoTSCandrefertoSC-100forreportrequirements.f.ImplementprocedureSC-3.30.1,ALTERNATIVESHUTDOWNFORCONTROLCOMPLEXFIRE.DONOTcontinueinthisprocedure.NOTE:RefertoSC-100,GINNASTATIONEVENTEVALUATIONANDCLASSIFICATION.4EstablishLocalOperatingStations(RefertoAttachmentA)5EstablishAFWToTheSteamGenerators:a.Start".-BOTHMOTORDRIVENAPWPUMPS-b.VerifyMDAPWpumpflows-LESSTHAN230GPMa.StarttheTDAPWpump.LocallyopenTDAFWpumpsteamadmissionvalvesatthesteamheaderMOV-3504A,MOV-3505A.b.LocallythrottleAFWflow.

l4QlI~r'lz.<.i4tl,h EOP:AP-CR.1TITLE:CONTROLROOMINACCESSIBILITYREV:10PAGE5of6STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED6EstablishChargingFlow:a.Chargingpumps-ATLEASTONERUNNINGa.Startachargingpump.b.Controlchargingandletdown-TOMAINTAINPRESSURIZERLEVEL7EstablishBorationOfTheRCSToTheXenonFreeCSDCondition:a.Referto0-3.1-FORDETERMINATIONOFAMOUNTOFBORICACIDTOBEADDEDb.Start-ABORICACIDPUMPc.Manuallyopen-MOV-350d.Stopboration-WHENREQUIREDBORICACIDHASBEENADDED8CheckSWPumps-ATLEASTONERUNNINGINEACHLOOPStartpumpsasnecessary.9CheckCNMTRecircFans-ATLEASTTWORUNNINGStartfansasnecessary.10CheckS/GLevels-BETWEEN77~oAND854ThrottleAFVflowasnecessary.llCheck-IFTHECONTROLROOMISAGAINHABITABLEReturntoStep5.

i4VAllIpa;1~

EOP:AP-CR.1CONTROLROOMINACCESSIBILITYREV10PAGE6of6STEPACTION/EXPECTEDRESPONSERESPONSENOTOBTAINED12EstablishNormalControlRoomOperations:a.Restore-NORMALOPERATIONOFEQUIPMENToReferto0-2.2,PLANTFROMHSDTOCOLDSHUTDOWN-OR-oRefertoES-0.2,NATURALCIRCULATIONCOOLDOWN-END-s,1UI.Av EOP:AP-CR.1TITLE:CONTROLROOMINACCESSIBILITYREV:10PAGE1of1ATTACHMENTADutiesofPersonnelDuringaControlRoomEvacuationSHIFTSUPERVISOR-Willdirectoverallplantoperationsandrecoveryactions.NospecificdutystationisassignedbuttheShiftSupervisorshouldmaintaincommunicationwiththevariousgroupsworkingtorecoverfromtheevacuation.CONTROLROOMFOREMANIWillassist.theHeadControlOperatorintransferringequipmenttolocalcontrol,aftercompletionofthetransfertheControlRoomForemanwilldirecttheoper-ator'sactionstorecovertheplant.HEADCONTROLOPERATORWillgotoAuxiliaryFeedwaterpumpareatakingoperatingprocedures"O"book,officialrecords;curvebookwithhimandtransferequipmenttolocalcontrol.CONTROLOPERATORWillgotothelocaloperatingstationintheChargingPumpRoom.PRIMARYAUXOPERATOR-WillgotothelocaloperatingstationsintheBoricAcidTankRoom.SHIFTTECHNICALADVISORWillassisttheHeadControlOperatorwhileremainingcognizant".ofplantconditions.OTHERPERSONNEL-WillassumefirefightingorotherdutiesasdirectedbytheShiftSupervisororControlRoomForeman.

Jyll,10