ENS 57865: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (StriderTol Bot insert) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 21: | Line 21: | ||
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance: | The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance: | ||
The affected SG level instrumentation is for emergency feedwater automatic initiation. The instruments were declared inoperable due to a reference leg leak in containment. | The affected SG level instrumentation is for emergency feedwater automatic initiation. The instruments were declared inoperable due to a reference leg leak in containment. | ||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2025/ | | URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2025/20250814en.html#en57865 | ||
}}{{unit info | }}{{unit info | ||
| Unit = 1 | | Unit = 1 | ||
Latest revision as of 06:20, 14 August 2025
| Where | |
|---|---|
| Davis Besse Ohio (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown | |
| LER: | 05000346/LER-2025-001 Required Shutdown for Steam Generator Low Level Instrumentation Reference Leg Steam Leak |
| Time - Person (Reporting Time:+-2.38 h-0.0992 days <br />-0.0142 weeks <br />-0.00326 months <br />) | |
| Opened: | Matthew Allan 17:58 Aug 12, 2025 |
| NRC Officer: | Robert A. Thompson |
| Last Updated: | Aug 12, 2025 |
| 57865 - NRC Website
| |